1.Effect of different layers of masseter on the bony structure of facial lateral area
Yu-Qi ZHAO ; Jin-Rui JIANG ; Jin-Ran CHEN ; Ze-Chuan WANG ; Hou-En ZHOU ; Wen-Di XU ; Liu-Jun YONG
Acta Anatomica Sinica 2025;56(2):208-213
Objective To observe the morphology of the superficial,middle,and deep layers of the masseter muscle and related bony structures in the lateral facial region of adults through gross anatomy,and to probe into the effects of these muscle layers on the bony structures of the lateral facial region.Methods The bilateral masseter muscles of 12 adult cadavers were exposed,and the superficial,middle,and deep layers were separated and measured for muscle length,tendon length,and muscle belly length.After the masseter muscles were stripped,the total thickness was measured,and the mandible and zygomatic arch were exposed to measure the angle of the mandibular angle,thickness of the zygomatic arch,and width of the zygomatic arch.Observations were made of the masseter tuberosities,and statistical analysis was conducted on their interrelations.Results The zygomatic arch thickness was positively correlated with the length of superficial,middle and deep masseter muscles and the length of superficial and middle masseter belly(r superficial masseter length=0.624,r middle masseter length=0.787,r deep masseter length=0.423,r superficial masseter belly length=0.493,r middle masseter belly length=0.548).The width of the zygomatic arch was positively correlated with the lengths of the superficial and middle muscle layers and the middle muscle belly length(r superficial masseter length=0.527,r middle masseter length=0.521,r middle masseterbelly length=0.437).The angle of the mandibular angle was only negatively correlated with the middle muscle belly length(r=-0.422).The tuberosities of the superficial and middle masseter muscles were not affected by the corresponding muscle layers;However,the tuberosity of the deep masseter was negatively correlated with the length of the deep muscle and the length of the deep tendon(r deep masseter length=-0.543,r deep masseter tendon length=-0.443).Conclusion In the masseter muscle layers of Chinese individuals,the superficial and middle layers have the most significant impact on the bony structures structures of the lateral facial region.These findings are of guiding significance for the remodeling of structures in the lateral facial region.
2.Safety and surgical strategy of laparoscopic partial gastrectomy for gastrointestinal stromal tumors at the esophagogastric junction
Long WANG ; Haiqiao ZHANG ; Yong HUANG ; Jiaxuan LI ; Zhi ZHENG ; Xiaoye LIU ; Jie YIN ; Jun ZHANG
International Journal of Surgery 2025;52(9):598-604
Objective:To investigate the perioperative safety, short-term and long-term efficacy, and surgical strategy of laparoscopic partial gastrectomy for gastrointestinal stromal tumors at the esophagogastric junction.Methods:Seventy-eight patients with mesenchymal tumors in the esophagogastric junction were retrospectively enrolled from September 2018 to August 2023 in which the upper edge of the tumor is less than 2 cm from the Z-line or has invaded the Z-line <1/2 circumference. There were 31 males (39.7%) and 47 females (60.3%), with an average age of (57.2±11.8) years and an average body mass index of (24.5±3.5) kg/m 2. All cases were divided into the wedge resection (WR) group ( n=51) and the resection by opening all of the layers of the stomach wall (RASW) group ( n=27) according to the surgical methods. Surgical outcomes, complications, recover and postoperative gastroesophageal reflux of both groups were compared. The measurement data with a normal distribution were represented by mean±standard deviation ( ± s), and values were compared using the independent sample t-test. The measurement data with a skewed distribution were represented by median (interquartile range) [ M( Q1, Q3)], and values were compared using the Mann-Whitney U test. Count data were expressed as examples (percentages) [ n(%)], and the χ2 test was used to compare countable data. A non-parametric test was used to compare the grade data. Results:The WR group had shorter operation time [(97.1±32.6) min vs (149.9±54.9) min, t=-5.33, P<0.001], less intraoperative blood loss [15(10, 20) mL vs 20(10, 50) mL, z=-2.47, P=0.014], shorter postoperative exhaust time [2(1, 3) d vs 3(2, 3) d, z=-2.49, P=0.013], shorter postoperative oral intake time [2(2, 3) d vs 4(2, 5) d, t=-3.70, P<0.001], shorter postoperative semi-liquid diet time[5(4, 6) d vs 7(5, 8) d, z=-3.57, P<0.001], and shorter postoperative hospital stay [5(4, 6) d vs 7(6, 8) d, z=-4.16, P<0.001] than the RASW group, with statistically significant differences. There was no significant difference in short-term (≤30 days) complications between the two groups (2.0% vs 3.7%, z=-0.46, P=0.648). No cases of cardia stenosis occurred in either group. In the WR group, 3 patients developed gastroesophageal reflux at 6 months postoperatively, with 2 patients relieved after taking acid-suppressing drugs and 1 patient not completely relieved. In the RASW group, 1 patient developed gastroesophageal reflux at 6 months postoperatively and was not completely relieved after taking acid-suppressing drugs. No other patients had gastroesophageal reflux. No other patients have gastroesophageal reflux. Conclusions:WR and RASW are safe and feasible for mesenchymal tumors at the esophagogastric junction in which the upper edge of the tumor is less than 2 cm from the Z-line or has invaded the Z-line <1/2 circumference, and has achieved an excellent short-term effect. The choice of surgical approach can be determined based on varions factors such as the location of the tumor, the relationship of the position between the tumor and the cardia, and whether the tumor is exophytic growth.
3.Study on the modeling method of general model of Yaobitong capsule intermediates quality analysis based on near infrared spectroscopy
Le-ting SI ; Xin ZHANG ; Yong-chao ZHANG ; Jiang-yan ZHANG ; Jun WANG ; Yong CHEN ; Xue-song LIU ; Yong-jiang WU
Acta Pharmaceutica Sinica 2025;60(2):471-478
The general models for intermediates quality analysis in the production process of Yaobitong capsule were established by near infrared spectroscopy (NIRS) combined with chemometrics, realizing the rapid determination of notoginsenoside R1, ginsenoside Rg1, ginsenoside Re, ginsenoside Rb1, ginsenoside Rd and moisture. The spray-dried fine powder and total mixed granule were selected as research objects. The contents of five saponins were determined by high performance liquid chromatography and the moisture content was determined by drying method. The measured contents were used as reference values. Meanwhile, NIR spectra were collected. After removing abnormal samples by Monte Carlo cross validation (MCCV), Monte Carlo uninformative variables elimination (MC-UVE) and competitive adaptive reweighted sampling (CARS) were used to select feature variables respectively. Based on the feature variables, quantitative models were established by partial least squares regression (PLSR), extreme learning machine (ELM) and ant lion optimization least squares support vector machine (ALO-LSSVM). The results showed that CARS-ALO-LSSVM model had the optimum effect. The correlation coefficients of the six index components were greater than 0.93, and the relative standard errors were controlled within 6%. ALO-LSSVM was more suitable for a large number of samples with rich information, and the prediction effect and stability of the model were significantly improved. The general models with good predicting effect can be used for the rapid quality determination of Yaobitong capsule intermediates.
4.Research Progress of Selective Nerve Root Block in the Treatment of Lumbosacral Radiculopathy
Leilei GAO ; Jun LIU ; Xiaoxia HUANG ; Tao LIU ; Yong TENG
Medical Journal of Peking Union Medical College Hospital 2025;16(3):739-748
Lumbosacral radiculopathy refers to the pain syndrome caused by inflammation or mechanical compression of the lumbar nerve root, mainly manifested as low back pain, and radiating to the lower limbs in cutaneous mode, which can be accompanied by numbness, paresthesia, tingling, muscle weakness and loss of specific reflexes and other symptoms, which not only bring physical pain and life inconvenience to the patients, but also bring huge economic burden to the social medical care. Selective nerve root block(SNRB), as a safe, effective, low-cost, precise and minimally invasive clinical technique, can accurately intervene in specific nerve roots and quickly relieve pain symptoms by reducing inflammation and improving the surrounding environment of nerves. However, there are still many challenges and controversies in practice, such as precise targeting requirements, drug selection, potential risks and complications, and differences in efficacy among different patient populations. The purpose of this review is to systematically review and analyze the existing research results on SNRB, so as to provide useful reference and guidance for the further development of this field.
5.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
6.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
7.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
8.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
9.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
10.Analysis and application thinking of standards for 500 kinds of traditional Chinese medicine formula granules on base of industrial practice.
Yong LIU ; Jun ZHANG ; Xin-Hai DONG ; Lin ZHOU ; Dong-Mei SUN ; Fu-Lin MAO ; Zhen-Yu LI ; Lei HUANG ; Jin-Lai LIU
China Journal of Chinese Materia Medica 2025;50(5):1427-1436
Following the release of the Technical Requirements on Quality Control and Standard Establishment of Traditional Chinese Medicine Formula Granules by the National Medical Products Administration in 2021, Chinese Pharmacopoeia Commission has promulgated 296 national drug standards so far, and most provinces have started the work of establishing provincial standards as supplements. The promulgation of standards fostered high-quality development of the industry. Since the implementation of national and provincial standards for more than three years, enterprises have gained deep understanding and hands-on experiences on the characteristics, technical requirements, production process, and quality control of traditional Chinese medicine(TCM) formula granules. Meanwhile, challenges have emerged restricting the high-quality development of this industry, including how to formulate quality control strategies for medicinal materials and decoction pieces, how to reduce manufacturing costs, and how to improve the pass rate and product stability under high standards. Based on the work experiences from standard management and process research, this article analyzed the distribution of sources, processing methods, dry extract rate ranges, process requirements for volatile oil-containing decoction pieces, control measures of safety indices, characteristics and trends of setting characteristic chromatograms or fingerprints, characteristics and trends of setting content ranges, and main differences between national standards and provincial standards. On the one hand, this article aims to present main characteristics for deeply understanding different indicators in standards and provide basic ideas for establishing quality and process control systems. On the other hand, from the perspective of industrial practice, suggestions are put forward on the important aspects that need to be focused on in the quality and process control of TCM formula granules.
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Medicine, Chinese Traditional/standards*
;
China
;
Drug Industry/standards*

Result Analysis
Print
Save
E-mail