1.Research on The Genealogical Inference Efficiency of High-density SNPs
Jing LI ; Yi-Jie SUN ; Wen-Ting ZHAO ; Zi-Chen TANG ; Jing LIU ; Cai-Xia LI
Progress in Biochemistry and Biophysics 2026;53(3):740-753
ObjectiveThis study aims to explore the potential of different orders of magnitude single-nucleotide polymorphism (SNP) locus combinations for predicting distant kinship relationships. A high-density SNP locus set was constructed, and a comprehensive assessment of its inference capability was conducted. MethodsFirstly, we selected three commercial chip panels, CGA (Chinese genotyping array, Illumina), GSA (Global screening array, Illumina), Affy (23MF_V2 high-density SNP array, Affymetrix) and merged them after quality control, forming a high-density SNP locus panel(1 180 k). Secondly, we selected 161 samples and collected their peripheral blood samples by using whole-genome sequencing technology. Within this sample population, the levels of kinship relationships fully covered the range from level 1 to level 9, and the number of kinship pairs at each level was consistently maintained at over 50 pairs. From 161 samples data of whole-genome sequencing, the 1 180 k locus set was extracted, which is referred to as the high-density SNP locus set in the following text. The kinship inference was conducted using the identity-by-descent (IBD) algorithm with the selected optimal parameters. To comprehensively evaluate the performance of the high-density SNP locus set in kinship inference, we compared it with the three commercial chip panels, the intersection of these three chip loci, and the control sets constructed by randomly reducing the number of the high-density SNP locus set. Based on the changes in the IBD lengths, as well as the dynamic trends in prediction accuracy, we conducted a scientific assessment of the kinship inference capability of the high-density SNP locus set. ResultsAfter screening, a set of 1 184 334 autosomal SNPs was obtained. During the process of screening the optimal IBD length threshold, the result revealed that 0 cM, 1 cM, and 2 cM all demonstrated good applicability. However, to avoid the issue of a large amount of redundant information caused by setting a too low IBD length threshold, this study ultimately selected 2 cM as the optimal threshold. Compared with the average results of three chip panels, the high-density SNP locus set increased the total IBD length and the average IBD length across levels 1-9; the accuracy of the confidence interval for level 8 was 70.97%, which represented a 3.50% improvement; the average confidence interval accuracy for levels 1-8 was 91.39%, representing a 1.00% increase; and the false negative rates at levels 8 and 9 were reduced by 2.42% and 6.76%, respectively. The system efficacy of the high-density SNP locus set for kinship inference of first to eighth degree relationships reached 98.91%. Through random reduction of the high-density SNP locus set results, it is found that increasing the number of SNPs with the panel, the detection efficiency of IBD length showed a significant upward trend. At the same time, the overall trend in the accuracy of kinship relationship prediction as well as the confidence interval accuracy also indicated that both metrics steadily increased with the addition of more loci. ConclusionThe results show that the high-density SNPs panel significantly enhances the efficacy of distant kinship inference, accurately covering kinship degrees, with the average confidence interval accuracy for first to eighth degree relationships stably above 90%. The study finds that increasing the number of SNPs panel can improve the ability to predict distant kinship.
2.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
3.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
5.Lumbar Spondylolysis in Chinese Adults: Prevalence and Musculoskeletal Conditions.
Dong YAN ; Yan Dong LIU ; Ling WANG ; Kai LI ; Wen Shuang ZHANG ; Yi YUAN ; Jian GENG ; Kang Kang MA ; Feng Yun ZHOU ; Zi Tong CHENG ; Xiao Guang CHENG
Biomedical and Environmental Sciences 2025;38(5):598-606
OBJECTIVE:
To determine the prevalence of lumbar spondylolysis (LS) and the proportion of spondylolytic spondylolisthesis (SS) in China, and to evaluate the musculoskeletal status of patients with LS and SS.
METHODS:
Spine Computed Tomography (CT) images were collected from community populations aged 40 and above in a nationwide multi-center project. LS was diagnosed, and SS was graded by an experienced radiologist. Bone mineral density (BMD) and paraspinal muscle parameters were quantified based on CT images.
RESULTS:
One hundred and seventeen patients of a total of 3,317 individuals were diagnosed with LS, corresponding to a prevalence rate of 3.53%. 63 of the 1,214 males (5.18%) and 54 of the 2,103 females (2.57%) were diagnosed with LS. SS occurred in 64/121 vertebrae (52.89%). BMD was not associated with LS ( P = 0.341). The L5 extensor paraspinal muscle density was higher in the LS group than in the non-LS group. In the LS group, patients with SS had a smaller L5 paraspinal extensor muscle cross-sectional area than those without SS ( P = 0.003).
CONCLUSION
The prevalence of LS in Chinese adults was 3.53%, with prevalence rates of 5.18% in males and 2.57% in females. Patients with LS have higher muscle density, whereas those with SS have smaller muscle cross-sectional areas at the L5 level.
Humans
;
Male
;
Female
;
Middle Aged
;
China/epidemiology*
;
Prevalence
;
Adult
;
Lumbar Vertebrae/diagnostic imaging*
;
Spondylolysis/diagnostic imaging*
;
Aged
;
Bone Density
;
Tomography, X-Ray Computed
;
Aged, 80 and over
;
Spondylolisthesis/epidemiology*
;
East Asian People
6.Spatial-temporal Dynamics of Tuberculosis and Its Association with Meteorological Factors and Air Pollution in Shaanxi Province, China.
Heng Liang LYU ; Xi Hao LIU ; Hui CHEN ; Xue Li ZHANG ; Feng LIU ; Zi Tong ZHENG ; Hong Wei ZHANG ; Yuan Yong XU ; Wen Yi ZHANG
Biomedical and Environmental Sciences 2025;38(7):867-872
7.Determination of contezolid in human cerebro spinal fluid by UPLC-MS/MS
Ju-ping YUN ; Zi-he WANG ; Wen-jing WANG ; Wei LIU
The Chinese Journal of Clinical Pharmacology 2025;41(1):91-95
Objective To establish a method for determining the concentration of contezolid in human cerebro spinal fluid(CSF)using ultra high performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS).Methods Linezolid as the internal standard(IS)and acetonitrile as the protein precipitant.Waters ACQUITY UPLC? BEH C18(2.1 mm × 50.0 mm,1.7 μm)chromatographic column was used for separation,with a mobile phase of 0.1%formic acid aqueous solution-0.1%formic acid acetonitrile solution,gradient elution method,flow rate was 0.4 mL·min-1,column temperature was 40 ℃,automatic sampler temperature was 10 ℃,the analysis time was 4 minutes.Electrospray ion source,positive ion mode,and multi-reaction monitoring scanning mode were used.The monitoring and analysis ion pairs for contezolid were m/z 409.15→269.14,and the monitoring ion pairs for linezolid were m/z 338.14 → 195.10.The specificity,standard curve and lower limit of quantification(LLOQ),precision and recovery rate,matrix effect,residual effect,dilution effect and stability of the method were investigated.Results The endogenous substances in CSF do not interfere with the determination of the analyte contezolid and the internal standard linezolid,and the method has good specificity.Satisfactory linearity was observed within the concentration range of 20-5 000 ng·mL-1 for contezolid in CSF,the calibration curve was y=8.97 × 10-4x+1.95 × 10-2(r=0.999 1),and the LLOQ was 20 ng·mL-1.Precision of the intra-batch and inter-batch relative standard deviation(RSD)<15%,and the extraction recovery were 90.96%-98.71%.The average normalized matrix effect factor of the quality control CSF sample were 94.39%-100.25%.The RSD of dilution effect<15%.The CSF samples of contezolid were stored at room temperature,in the automatic sampler for 72 hours,-20 ℃ and-80 ℃ for 90 days,and subjected to repeated freezing and thawing three times,were stable with all of which the RSD<10%.Conclusion This method is high sensitivity,rapid,simple and accurate,which is very suitable for the therapeutic drug monitoring of contezolid in human CSF.
8.EEG phase prediction method based on long short-term memory network
Zi-yan PANG ; Xin-yu ZHAO ; Wen-shu MAI ; Yue-zhuo ZHAO ; Zhi-peng LIU ; Tao YIN ; Jing-na JIN
Chinese Medical Equipment Journal 2025;46(3):1-8
Objective To propose a brain electrical phase prediction method based on long short-term memory network(LSTM)to improve the accuracy and robustness of phase synchronization prediction in transcranial magnetic stimulation(TMS).Methods First,an LSTM consisting of an input layer,an LSTM layer,an ReLU activation layer,a fully connected layer and a regression layer was constructed to capture the EEG signal features through the synergistic action of input gates,forgetting gates and output gates.Second,eye-open resting-state EEG data from 30 healthy subjects were trained using the LSTM to obtain a predictive model for EEG signal and EEG phase prediction.Finally,the LSTM method and the traditional autoregressive(AR)method were compared in terms of the phase prediction errors at the overall and individual levels and the prediction performance for peaks and troughs.A regression model was used to explore the relationships between instantaneous EEG amplitude,signal-to-noise ratio and phase prediction error with the LSTM method.Results The LSTM method achieved a total phase prediction error of 0.04°±5.69°,which was lower than that of the traditional AR method(-3.36°±51.13°).For each subject,the LSTM method demonstrated superior phase prediction accuracy compared to the traditional AR method(P<0.001).The accuracy for predicting peaks(troughs)by the LSTM method(about 89%)was higher than that by the traditional AR method(about 10%).Unlike the traditional AR method,the LSTM method didnot result in linear relationships between instantaneous EEG amplitude,signal-to-noise ratio and phase prediction error,with Pvalues being 0.58 and 0.18,respectively.Conclusion The LSTM-based brain electrical phase prediction method shows high accuracy and robustness when used for EEG phase-synchronized TMS.[Chinese Medical Equipment Journal,2025,46(3):1-8]
9.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
10.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.

Result Analysis