1.Mosquito monitoring and influence of meteorological factors on mosquito density around Beijing Capital International Airport, 2016-2022
Ran FENG ; Tie-zheng MA ; Si-jie ZHU ; Bo TIAN ; Fei QUAN ; Zhi-lin WU ; Xiao-tao LIU ; Fu-yuan ZHANG ; Song-jian ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):40-48
Objective To understand mosquito density, species composition, and seasonal variations around the Beijing Capital International Airport(BCIA)and provide scientific evidence for mosquito-borne disease prevention and control. Methods Meteorological data were collected from 2016 to 2022, and mosquito density was monitored at seven surveillance sites around the BCIA from May to October each year using CO2-baited mosquito traps to analyze the relationship between mosquito density and meteorological factors. Results In total,68 518 female mosquitoes were captured, with a mosquito density of 10.20 per light · hour. The dominant species was Culex pipiens pallens(73.90%), followed by Aedes albopictus(9.71%)and Ae. vexans(9.29%);the mosquito density was highest in 2016(14.8 per light·hour)and lowest in 2022(4.46 per light·hour). Significant statistical differences were observed in mosquito density among different species(F=18.118, P<0.05). The density of Cx. pipiens pallens and other mosquito species showed a mutually exclusive trend; the peak of mosquito density varied based on years and habitats, with significant statistical differences in mosquito density among different habitats(F=8.504, P<0.05). The highest mosquito density was observed near the Wenyu River(21.50 per light·hour), whereas the lowest was recorded at the BCIA construction site(2.44 per light· hour). The monthly average temperature(r=0.595), monthly average highest temperature(r=0.575), and monthly average lowest temperature(r=0.624)showed moderate positive correlations, whereas the monthly average air pressure(r=-0.484)showed a moderate negative correlation. The monthly average minimum temperature was included in the regression model(F=25.575, P<0.000), and the equation Y=1.029X4-8.181 was used. The monthly average air pressure 2 months prior(b=-2.418, β=-1.619, P<0.05)and the monthly average relative humidity(b=-0.739, β=-1.201, P<0.05)significantly negatively predicted the mosquito density. Notably, the regression equation used was y=2526.170+(-2.418)X9+(-0.739)X13. The exposure-response analysis revealed that the density of mosquitoes was not linearly related to the average monthly air pressure, rainfall, and duration of sunshine. Conclusions The dominant mosquito species around the BCIA was Cx. pipiens pallens, Ae. albopictus, and Ae. vexans. During the control of Cx. pipiens pallens, the impact on other mosquito species must also be considered. Environmental management, breeding sites, and scientific use of pesticides should be prioritized based on the activity periods of mosquitoes. Further studies on mosquitoes and meteorological factors should be conducted to provide references and novel avenues for mosquito control.
2.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
3.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
4.Quantitative analysis of motion of cardiac substructures in deep inspiratory breath holding radiotherapy for left breast cancer
Zhao-hui TANG ; Zhe ZHANG ; Wei-bin MAO ; Bo HUANG ; Jun-feng AI ; Chao-fan ZHU ; Zhi-chao XIE ; Ya-jie LIU
Chinese Medical Equipment Journal 2025;46(3):54-58
Objective To quantify the volume and movement of cardiac substructures by using coronary computed tomography angiography(CCTA)to provide guidance for the design of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.Methods Totally 18 female patients who received conventional chest plain scan and CCTA were selected to simulate the design process of radiotherapy plan for left breast cancer patients with internal mammary lymph nodes.Retrospective reconstruction of CCTA data was performed for each patient,with 10 phase images(with an interval of 10%)within a R-R cardiac cycle(10%-100%)to simulate the true range of motion of the heart.The heart,left atrium(LA),left ventricle(LV),right atrium(RA),right ventricle(RV),left anterior descending artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA)were contoured at each phase.The distances from the centroid position to the average position of LAD,LCX and RCA were measured at each phase in the superior-inferior(SI),anterior-posterior(AP)and left-right(LR).The average volume and range of volume changes of LA,LV,RA,RV and heart were analyzed within a cardiac cycle.The expansion margins of planning organs at risk volume(PRV)were calculated.SPSS 19.0 software was used for statistical analysis.Results The following average absolute displacements were found in SI,AP and LR coordinates:(1.8±0.7)mm,(1.2±0.5)mm and(1.5±0.5)mm for LAD,respectively;(2.1±0.7)mm,(1.5±0.6)mm and(1.9±0.7)mm for LCX,respectively;(1.6±0.5)mm,(2.2±0.9)mm and(2.2±0.8)mm for RCA,respectively.The volume changes of LA,LV,RA,RV and heart within a cardiac cycle ranged from 34.3 to 63.9 cm3,122.1 to 154.3 cm3,29.3 to 53.6 cm3,57.2 to 94.3 cm3 and 480.1 to 515.4 cm3,respectively.The theoretical expansion margins of LAD,LCX and RCA in all the three directions were within 2 mm.Conclusion The ranges of movement and volume changes of cardiac substructure are quantitati-vely displayed,and references are provided for the planning of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.[Chinese Medical Equipment Journal,2025,46(3):54-58]
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Predictive value of IVST,E/A combined AV for hypertensive heart disease and their association with blood pressure grade
Cui-cui LIU ; Yi HE ; Jing-qi QIU ; Shuang LIANG ; Qian WANG ; Zhi-bo ZHANG
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(3):374-379
Objective:To investigate the predictive value of interventricular septal thickness(IVST),the ratio of mitral ear-ly diastolic peak flow velocity to late diastolic peak flow velocity(E/A)combined with aortic valve flow velocity(AV)for hypertensive heart disease(HHD)and its association with blood pressure grade.Methods:A total of 202 patients with hy-pertension suspected of HHD admitted to Qinhuangdao Hospital of Dongfang Hospital,Beijing University of Chinese Medi-cine between May 2020 and May 2023 were enrolled and divided into HHD group(n=102)and non-HHD group(n=100)according to color Doppler energy imaging and blood pressure diagnosis.Blood pressure,IVST,E/A and AV were measured in two groups.The predictive value of IVST,E/A and AV for HHD were evaluated by receiver operating charac-teristic(ROC)curve.According to hypertension grading,patients in HHD group was divided into grade 1~2 group(n=59)and grade 3 group(n=41).The association of IVST,E/A,AV with blood pressure grade in HHD patients were ana-lyzed by Spearman correlation analysis.Results:Compared with patients in non-HHD group,those in HHD group had significant higher IVST,and significant lower E/A and AV(P<0.001 all);Compared with patients in grade 1~2 group,those in grade 3 group had significant higher IVST,and significant lower E/A and AV(P<0.001 all).ROC curve showed that the AUC of IVST,E/A and AV alone and their combination in HHD diagnosis was 0.798(95%CI 0.736~0.851),0.682(95%CI 0.613~0.746),0.810(95%CI 0.748~0.862)and 0.927(95%CI 0.881~0.959)respectively,and the diagnostic value of combined detection was significantly higher than those of single detections(Z=4.431,5.669,3.948,P=0.001 all).Spearman correlation analysis showed that E/A and AV were significant negatively correlated with blood pressure grade(r=-0.725,-0.781),while I VST was significant positively correlated with blood pressure grade(r=0.714),and combined detection possessed a stronger correlation with it in HHD patients(r=0.875,P<0.001 all).Con-clusion:The combined detection of I VST,E/A and AV demonstrates a good predictive value for HHD and exhibits a sig-nificant correlation with blood pressure grade in HHD patients.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Research progress in exploring cognitive processes based on pupil changes
Xiao-Ting QIAO ; Zi-Wei NI ; Bo-Zhi LIU ; Ya-Qian GUO ; Yan ZHAO ; Cai-Lian RUAN ; Ya-Yun WANG
Acta Anatomica Sinica 2025;56(3):357-363
In recent years,more and more researches has focused on the correlation between cognitive activity and physiological variables.The change of pupil is regarded as an important target in the cognitive process,and has become a hot research field.This review focuses on the three key brain regions that regulate pupil change,and reflects the neurophysiological mechanism behind pupil change by elaborating the neural pathways related to pupil change and cognitive performance.Based on recent studies on pupil change in cognitive diseases,it aims to promote the application of pupil change in the field of cognitive science in the future.


Result Analysis
Print
Save
E-mail