1.Etiology and treatment of dysuria shortly after holmium laser enucleation of the prostate: a report of 98 cases
Chao LU ; Xin GU ; Wenfeng LI ; Chong LIU ; Bao HUA ; Jiangyi WANG ; Minkai XIE ; Yiwei WANG ; Qing YANG
Journal of Modern Urology 2026;31(5):435-439
Objective To investigate the etiology and treatment of dysuria shortly after holmium laser enucleation of the prostate (HoLEP) for benign prostatic hyperplasia (BPH), so as to improve the therapeutic efficacy. Methods A retrospective analysis was conducted on 1361 BPH patients who received HoLEP at our hospital during Mar. 2018 and Mar. 2025. All patients underwent ultrasound, computed tomography (CT), urethral probing or radiography, cystourethroscopy, and urodynamic testing. The causes, treatments and prognosis of dysuria after operation were summarized. Results ninety-eight patients (7.2%) experienced dysuria within 3 months after surgery, and all patients received initial urethral dilation. Among the 62 cases with urethral stricture, 28 were treated with urethral dilation (average of 8 sessions), 16 underwent external urethral incision, 8 underwent anterior urethroplasty, and 10 underwent transurethral plasma incision for urethral stricture. Of the 12 cases with residual prostate tissue, 5 underwent urethral plasma prostatectomy and 7 received medication. All of the 12 cases with bladder neck contracture underwent transurethral plasma incision of the bladder neck and local drug injection. Five cases with intravesical blood clots underwent urethral blood clot irrigation, 2 of which developed active bleeding and then underwent electrocoagulation. Four cases with detrusor dysfunction had catheters re-indwelled for one week followed by medication. Two cases with stone and one case with tissue fragment impacted in the urethra underwent urethral holmium lithotripsy and cystoscopic removal. All patients underwent reoperation successfully and experienced complete resolution or significant improvement of urinary difficulties. Conclusion A certain proportion of patients experience dysuria after HoLEP, with diverse etiologies. The combination of prevention and treatment can reduce the incidence of dysuria.
2.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
3.Application of contrast-enhanced ultrasound in the preoperative evaluation of carotid body tumor
Guangchao GU ; Xiaoyan ZHANG ; Bo ZHANG ; Rong ZENG ; Yuexin CHEN ; Bao LIU ; Jianchu LI ; Yuehong ZHENG
Chinese Journal of General Surgery 2025;40(6):468-472
Objective:To explore the application of contrast-enhanced ultrasound in the preoperative evaluation of carotid body tumor (CBT).Methods:The clinical data of 13 CBT patients undergoing contrast enhanced ultrasound test and surgical treatment at Peking Union Medical College Hospital from Nov 2017 to Aug 2021 was retrospectively analyzed.Results:Among the 13 patients, 7 patients had bilateral lesions. 18 tumors were identified by contrast enhanced ultrasound, which showed rich blood supply, with marked enhancement in 13 tumors and moderate enhancement in 5 tumors. The origins of the arterial supply for tumors were identified by contrast enhanced ultrasound. Time-intensity curve analysis showed that the tumors had enhancement characteristics of fast wash in and slow wash out. The mean contrast wash in time was (3.33±1.40) s, the mean peak intensity was (10.41±1.74) dB, and the mean wash out time was (56.47±22.28) s. A total of 13 cases underwent successful surgical removal. Five cases of external carotid artery ligation and 2 cases of internal carotid artery reconstruction were performed during surgery. Postoperative transient neurological injury occurred in 5 cases. There were no cases of cerebral infarction or death in the perioperative period. Mean postoperative follow-up was 14.31 months. Five cases of neurological injury had satisfactory recovery and no other adverse events occurred.Conclusions:Contrast enhanced ultrasound is an effective method of preoperative imaging assessment for CBT, which helps the surgical planning and preoperative preparation.
4.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
5.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
6.Application of contrast-enhanced ultrasound in the preoperative evaluation of carotid body tumor
Guangchao GU ; Xiaoyan ZHANG ; Bo ZHANG ; Rong ZENG ; Yuexin CHEN ; Bao LIU ; Jianchu LI ; Yuehong ZHENG
Chinese Journal of General Surgery 2025;40(6):468-472
Objective:To explore the application of contrast-enhanced ultrasound in the preoperative evaluation of carotid body tumor (CBT).Methods:The clinical data of 13 CBT patients undergoing contrast enhanced ultrasound test and surgical treatment at Peking Union Medical College Hospital from Nov 2017 to Aug 2021 was retrospectively analyzed.Results:Among the 13 patients, 7 patients had bilateral lesions. 18 tumors were identified by contrast enhanced ultrasound, which showed rich blood supply, with marked enhancement in 13 tumors and moderate enhancement in 5 tumors. The origins of the arterial supply for tumors were identified by contrast enhanced ultrasound. Time-intensity curve analysis showed that the tumors had enhancement characteristics of fast wash in and slow wash out. The mean contrast wash in time was (3.33±1.40) s, the mean peak intensity was (10.41±1.74) dB, and the mean wash out time was (56.47±22.28) s. A total of 13 cases underwent successful surgical removal. Five cases of external carotid artery ligation and 2 cases of internal carotid artery reconstruction were performed during surgery. Postoperative transient neurological injury occurred in 5 cases. There were no cases of cerebral infarction or death in the perioperative period. Mean postoperative follow-up was 14.31 months. Five cases of neurological injury had satisfactory recovery and no other adverse events occurred.Conclusions:Contrast enhanced ultrasound is an effective method of preoperative imaging assessment for CBT, which helps the surgical planning and preoperative preparation.
7.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
8.Clinical study of percutaneous transluminal coronary intravascular lithotripsy angioplasty for severe left main coronary artery calcification guided by intravascular ultrasound percutaneous coronary
Feng-Qi LIU ; Jun BAO ; Bai-Hong LI ; Chong-Hao CHEN ; Chang-Zheng GAO ; Yun-Feng GUO ; Xin GU ; Jian-Bin GU ; Xiao-Yan WANG
Chinese Journal of Interventional Cardiology 2024;32(7):383-389
Objective To explore the effectiveness and safety of percutaneous coronary artery shock wave balloon angioplasty(IVL)under the guidance of intravascular ultrasound(IVUS)for the treatment of severe calcification lesions in the left main artery(LM).Methods A total of 26 patients with severe LM(mouth,body,bifurcation)calcification admitted to Jiangnan University Affiliated Hospital from October 2022 to April 2024 were included,with an average age of 72.0(61.8,75.4)years.Under the guidance of IVUS,IVL was used for pre-treatment of calcified lesions,followed by percutaneous coronary intervention(PCI)with stent/drug balloon implantation.All patients were evaluated using IVUS before and after the use of IVL and after PCI.And compare the IVUS intracavity related data before and after treatment[plaque burden(PB)、minimum lumen area(MLA)、minimum lumen diameter(MLD)]and calcification fracture number,minimum stent area(MSA),stent expansion coefficient(expansion,EXP),etc.Results There were 26 patients(2 with opening lesions,7 with body lesions,and 17 with bifurcation lesions at the end of the main trunk),including 7 with stable angina pectoris(SAP),10 with unstable angina(UA),4 with acute ST-segment elevation myocardial infarction(STEMI),and 5 with non ST-segment elevation myocardial infarction(NSTEMI).The PB at the most severe site of calcification decreased by 79.50(76.00,83.75)%compared to 80.00(76.00,83.75)%after IVL(P=0.001),MLA increased by 3.39(3.14,3.68)mm2 compared to 3.38(3.14,3.67)mm2 after IVL(P=0.039),MLD increased by 3.21(3.07,3.30)mm compared to 3.20(3.07,3.30)mm after IVL(P=0.024),and there was 100%calcification rupture(1/2 cases,2/9 cases,≥3/15 cases).The stent/drug ball was successfully implanted 100%,with EXP of(89.15±4.42)%and an MSA of 7.20(6.46,7.45)mm2.No adverse events such as death,angina or recurrent myocardial infarction occurred during the 3 months follow-up after surgery.Conclusions After evaluation by IVUS and pre-treatment with IVL,PCI was successfully completed for severe calcification lesions in LM,and IVL can be used as an option for the treatment of severe calcification in LM.
9.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.
10.Three-dimensional Printing of Inertial Microchannel with Complex Cross-section and Characterization of Particle Inertial Focusing
Qiao GU ; Xin-Jie ZHANG ; Yao LIU ; Yang BAO ; Hang-Jie ZHU ; Ya-Wei CHEN
Chinese Journal of Analytical Chemistry 2024;52(1):93-101
Projection micro stereolithography three-dimensional(3D)printing method was proposed in this study to fabricate complex microchannels of combined cross-sections.By using 3D printing and polydimethylsiloxane(PDMS)replication methods,two inertial microfluidic chips of three-step and five-step cross-sections were fabricated,and the dimension precisions of the microchannels were controlled within 20 μm.Using the microfluidic chips,the movements of two fluorescent polystyrene particles with diameters of 10 and 6 μm in the stepped channels were investigated.In addition,numerical simulations were applied to demonstrate the inertial focusing mechanisms of particles in the channels.It was found that 10-μm particles had three equilibrium positions in the three-step channel,which located at the inner walls of the three steps,respectively,and most particles focused at the inner step.The 6-μm particles also had three equilibrium positions in the three-step channel.However,the particles migrated to the middle and the outer steps under high flow rates.In the five-step channel,when the flow rate was increased gradually,10-μm particles had a single and two equilibrium positions,respectively,and the particles migrated towards the inner channel wall under high flow rates.In comparison to 10-μm particles,6-μm particles had two stable equilibrium positions in the five-step channel at all flow rate range.It could be concluded that the quantity,shape and strength of the secondary flow vortex could be altered by changing structure of the combined cross-section,thus the equilibrium positions and quantities of the focusing particles could be also regulated.The research outcome might provide new insights for precise cell inertial manipulation and promote the application and development of inertial microfluidic technology in biomedical and other fields.

Result Analysis
Print
Save
E-mail