1.Effect of maternal pyrethroid pesticides exposure during pregnancy on lymphocytes in 1-year-old children: A birth cohort study
Zhiye QI ; Xia XIAO ; Shuqi CHEN ; Dandan ZHAO ; Xiaoxiao SONG ; Yan LI
Journal of Environmental and Occupational Medicine 2026;43(4):402-409
Background Pyrethroid pesticides (PYRs) can cross the placental barrier to cause intrauterine fetal exposure, which may lead to developmental immunotoxicity (DIT). However, the specific effect of maternal PYR exposure during pregnancy on the cellular immune function of 1-year-old children remains unclear. Objective To explore the effect of PYRs exposure throughout the entire pregnancy on peripheral blood lymphocytes in 1-year-old children and potential sensitive window period of PYRs exposure. Methods A birth cohort was established by enrolling pregnant women in their first trimester and following them and their infants until one year of age. Ultra-high performance liquid chromatography-tandem mass spectrometry was used to detect the levels of PYRs metabolites, including 3-phenoxybenzoic acid (3PBA), 4-fluoro-3-phenoxybenzoic acid (4F3PBA), and cis-3-(2,2-dichlorovinyl)-2,2- dimethylcyclopropane carboxylic acid (cis-DBCA), in the urine of pregnant women during the first trimester (gestational weeks 6-12), the second trimester (gestational weeks 21-24), and the third trimester (gestational weeks 33-36). Peripheral blood leukocyte and lymphocyte counts were measured in children at 12 months of age using the Coulter principle combined with flow cytometry. Exposure levels of PYRs metabolites in each trimester were divided into low, moderate, and high exposure groups based on the 25th (P25) and 75th (P75) percentiles. Meanwhile, participants were classified as having repeated high or low exposure if their metabolite levels were > P75 or <P25 in at least two trimesters, respectively, while all others were categorized as having repeated moderate exposure. Generalized linear models were used to analyze the associations between trimester-specific and repeated PYRs metabolite exposure levels and the peripheral blood white blood cell (WBC) and lymphocyte counts in children aged 1 year. Results A total of 336 mother-child pairs were included in this study. For the pregnant women, the total detection rates of maternal urinary 3PBA, 4F3PBA, and cis-DBCA across the three trimesters of pregnancy were 80.5%, 100.0%, and 81.3%, respectively; and median creatinine-corrected concentrations were 0.24, 0.36, and 0.42 μg·g−1, respectively. In children aged 1 year, the mean WBC and lymphocyte counts in peripheral blood were (8.9±2.0)×109·L−1 and (5.7±1.6)×109·L−1, respectively. The results of the generalized linear model analysis indicated that compared to the low exposure group, the high cis-DBCA exposure group during the third trimester of pregnancy had significantly lower peripheral blood WBC count (β=−0.87, 95%CI: −1.51, −0.23) and lymphocyte count (β=−0.64, 95%CI: −1.15, −0.13); and the repeated high-exposure group of cis-DBCA had significantly lower peripheral blood WBC count (β=−1.34, 95%CI: −2.34, −0.34) and lymphocyte count (β=−0.80, 95%CI: −1.60, −0.01) than the repeated low exposure group. Similarly, the repeated moderate-exposure group of cis-DBCA had a significantly lower peripheral blood WBC count (β=−0.83, 95%CI: −1.59, −0.07) than the repeated low exposure group. Conclusion High maternal exposure to PYRs with cis-DBCA as the major metabolite exposure is associated with decreased peripheral leukocyte and lymphocyte counts in children aged 1 year, and repeated high-level exposure throughout gestation appears to exacerbate DIT in offspring. The third trimester of pregnancy maybe a sensitive window for children's DIT induced by exposure to PYRs during pregnancy.
2.Imaging features of pulmonary nodules affecting lymph node metastasis in cT1-stage non-small cell lung cancer
Jinlong ZHAO ; Fengwei ZHANG ; Dazhi JIANG ; Cuiping YOU ; Baotao LÜ ; ; Minghui ZHANG ; Hongwei GUO ; Rong CHEN ; Haiqin WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(11):1547-1553
Objective To use imaging features of pulmonary nodules to predict the risk of lymph node metastasis in patients with cT1-stage non-small cell lung cancer (NSCLC), providing a reference for clinical decision-making. Methods A retrospective analysis was conducted on the imaging features and postoperative pathological results of cT1 NSCLC patients who underwent surgical treatment at Linyi People’s Hospital from July 2019 to July 2022. Patients were grouped and analyzed according to lymph node metastasis status. Results A total of 1 123 patients were included, comprising 471 males and 652 females, with a median age of 59 (52, 66) years. Comparative analysis revealed that sex, age, nodule location, nodule size on imaging, solid component size, consolidation tumor ratio (CTR), average CT value, and tumor proximity to the pleura all influenced lymph node metastasis. A nomogram was constructed, indicating that the probability of lymph node metastasis in cT1 NSCLC was positively correlated with solid component size, CTR, and average CT value of the pulmonary nodule, and negatively correlated with patient age. The area under the receiver operating characteristic curve was 0.929. Conclusion For cT1 NSCLC patients, the probability of lymph node metastasis can be predicted by measuring the solid component size, CTR, and average CT value of the pulmonary nodule, in conjunction with patient age. However, relying solely on pulmonary nodule imaging characteristics is insufficient to determine a specific lymph node dissection strategy.
3.Medium and long-term evaluation of the efficacy and growth monitoring of elastic appliances in the early orthodontic treatment of Class Ⅱ malocclusion
Pingxian LUO ; Jiangting WANG ; Ruijing ZHANG ; Mei CHEN ; Linyi LIU ; Rui SHE ; Xiujie WEN
Chongqing Medicine 2025;54(3):689-695
Objective To evaluate the efficacy of elastic appliances in the early correction of Class Ⅱmalocclusions in the replacement dentition.Methods A total of 15 children aged 7-9 years who were admit-ted to the Affiliated Stomatology Hospital of Southwest Medical University from June 2018 to August 2023 were selected as the observation group,and 15 children who were consulted but not treated in the hospital dur-ing the same period were selected as the control group.The changes of bone tissue,dental and alveolar tissue,soft tissue and occlusal relationship before and after treatment were evaluated in the two groups.In addition,X-ray images of the observation group were collected every 8 to 10 months for the whole process dynamic mo-nitoring.Results Before treatment,there was no significant difference in all indexes between the two groups(P>0.05).After treatment,there were statistical significances in the upper and lower alveolar base Angle(ANB),mandibular branch length(GO-CO),mandibular height(ANS-Me),mandibular position(S-GO),up-per central incisor inclination(U1-NA Angle),upper central incisor inclination convexity(U1-NA),lower central incisor process distance(L1-APo),the Z Angle and FH-N'Pg'Angle of soft tissue between the two groups(P<0.05).After treatment,the covering OB and covering OJ in the observation group were lower than those in the control group,and the proportion of ClassⅠ patients in molar relationship was higher than that in the control group,with statistical significance(P<0.05).After 3-4 years of treatment,ANB gradual-ly decreased,and the anterior-basilar plane-mandibular plane Angle(SN-MP)remained basically stable,and had a slight decreasing trend in the later period.The U1-NA Angle and the lower central incisor inclination(L1-NB Angle)were close to the normal mean during the whole treatment.Conclusion Using elastic appli-ances to treat patients with early replacement Class Ⅱ malocclusion,after 3-4 years monitoring and guid-ance,it can effectively improve the molar relationship,promote forward jaw growth,and create a harmonious and aesthetically pleasing facial soft tissue.
4.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
5.Assembly and network of Rhei Radix et Rhizoma surface microbiome shaped by processing methods and sampling locations.
Guangfei WEI ; Xiao CHEN ; Guozhuang ZHANG ; Conglian LIANG ; Zhaoyu ZHANG ; Bo ZHANG ; Shilin CHEN ; Linlin DONG
Chinese Herbal Medicines 2025;17(1):189-199
OBJECTIVE:
Rhei Radix et Rhizoma has five types of products, namely, raw rhubarb (RR), wine rhubarb (WR), vinegar rhubarb (VR), cooked rhubarb (CR), and rhubarb charcoal (RC). However, Rhei Radix et Rhizoma is easily contaminated with fungi and mycotoxins if not harvested or processed properly. Here, we intend to analyze how microbiome assemblies and co-occurrence patterns are influenced by sampling locations and processing methods.
METHODS:
High-throughput sequencing and internal transcribed spacer 2 (ITS2) were carried out to study the diversities (α- and β-diversity), composition (dominant taxa and potential biomarkers), and network complexitity of surface fungi on RR, WR, VR, CR, and RC collected from Gansu and Sichuan provinces, China.
RESULTS:
The phyla Ascomycota and Basidiomycota; the genera Kazachstania, Malassezia, and Asterotremella; and the species Kazachstania exigua, Asterotremella pseudolonga, and Malassezia restricta were the dominant fungi and exhibited differences in the two provinces and the five processed products. The α-diversity and network complexity were strongly dependent on processing methods. Chao 1, the Shannon index, and network complexity and connectivity were highest in the CR group. The α-diversity and network complexity were influenced by sampling locations. Chao 1 and network complexity and connectivity were highest in the Gansu Province.
CONCLUSION
The assembly and network of the surface microbiome on Rhei Radix et Rhizoma were shaped by processing methods and sampling locations. This paper offers a comprehensive understanding of microorganisms, which can provide early warning for potential mycotoxins and ensure the safety of drugs and consumers.
6.The role of selenoproteins in adipose tissue and obesity.
Yun-Fei ZHAO ; Yu-Hang SUN ; Tai-Hua JIN ; Yue LIU ; Yang-Di CHEN ; Wan XU ; Qian GAO
Acta Physiologica Sinica 2025;77(5):939-955
Selenoproteins, as the active form of selenium, play an important role in various physiological and pathological processes, such as anti-oxidation, anti-tumor, immune response, metabolic regulation, reproduction and aging. Although the expression level of selenoproteins in adipose tissue is significantly influenced by dietary selenium intake, it is closely related to the homeostasis of adipose tissue. In this review, we summarized the role of selenoproteins in the physiological function of adipose tissue and the pathogenesis of obesity in recent years, in order to provide a rationale for developing potential therapeutic agents for the treatment of obesity and related metabolic diseases.
Selenoproteins/metabolism*
;
Adipose Tissue/physiology*
;
Obesity/metabolism*
;
Humans
;
Animals
;
Selenium
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Nanomaterial-based Therapeutics for Biofilm-generated Bacterial Infections
Zhuo-Jun HE ; Yu-Ying CHEN ; Yang ZHOU ; Gui-Qin DAI ; De-Liang LIU ; Meng-De LIU ; Jian-Hui GAO ; Ze CHEN ; Jia-Yu DENG ; Guang-Yan LIANG ; Li WEI ; Peng-Fei ZHAO ; Hong-Zhou LU ; Ming-Bin ZHENG
Progress in Biochemistry and Biophysics 2024;51(7):1604-1617
Bacterial biofilms gave rise to persistent infections and multi-organ failure, thereby posing a serious threat to human health. Biofilms were formed by cross-linking of hydrophobic extracellular polymeric substances (EPS), such as proteins, polysaccharides, and eDNA, which were synthesized by bacteria themselves after adhesion and colonization on biological surfaces. They had the characteristics of dense structure, high adhesiveness and low drug permeability, and had been found in many human organs or tissues, such as the brain, heart, liver, spleen, lungs, kidneys, gastrointestinal tract, and skeleton. By releasing pro-inflammatory bacterial metabolites including endotoxins, exotoxins and interleukin, biofilms stimulated the body’s immune system to secrete inflammatory factors. These factors triggered local inflammation and chronic infections. Those were the key reason for the failure of traditional clinical drug therapy for infectious diseases.In order to cope with the increasingly severe drug-resistant infections, it was urgent to develop new therapeutic strategies for bacterial-biofilm eradication and anti-bacterial infections. Based on the nanoscale structure and biocompatible activity, nanobiomaterials had the advantages of specific targeting, intelligent delivery, high drug loading and low toxicity, which could realize efficient intervention and precise treatment of drug-resistant bacterial biofilms. This paper highlighted multiple strategies of biofilms eradication based on nanobiomaterials. For example, nanobiomaterials combined with EPS degrading enzymes could be used for targeted hydrolysis of bacterial biofilms, and effectively increased the drug enrichment within biofilms. By loading quorum sensing inhibitors, nanotechnology was also an effective strategy for eradicating bacterial biofilms and recovering the infectious symptoms. Nanobiomaterials could intervene the bacterial metabolism and break the bacterial survival homeostasis by blocking the uptake of nutrients. Moreover, energy-driven micro-nano robotics had shown excellent performance in active delivery and biofilm eradication. Micro-nano robots could penetrate physiological barriers by exogenous or endogenous driving modes such as by biological or chemical methods, ultrasound, and magnetic field, and deliver drugs to the infection sites accurately. Achieving this using conventional drugs was difficult. Overall, the paper described the biological properties and drug-resistant molecular mechanisms of bacterial biofilms, and highlighted therapeutic strategies from different perspectives by nanobiomaterials, such as dispersing bacterial mature biofilms, blocking quorum sensing, inhibiting bacterial metabolism, and energy driving penetration. In addition, we presented the key challenges still faced by nanobiomaterials in combating bacterial biofilm infections. Firstly, the dense structure of EPS caused biofilms spatial heterogeneity and metabolic heterogeneity, which created exacting requirements for the design, construction and preparation process of nanobiomaterials. Secondly, biofilm disruption carried the risk of spread and infection the pathogenic bacteria, which might lead to other infections. Finally, we emphasized the role of nanobiomaterials in the development trends and translational prospects in biofilm treatment.
10.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.

Result Analysis
Print
Save
E-mail