1.Reconstruction of 41 cases of large chest keloids with the pre-expanded internal mammary artery perforator flap
Zheng QI ; Tian MENG ; Kexin SONG ; Cheng FENG ; Zhengyun LIANG ; Wenbo LI ; Fuquan ZHANG ; Lingyan KONG ; Ning DING ; Youbin WANG
Chinese Journal of Plastic Surgery 2022;38(6):635-639
Objective:To analyze the clinical effects of the pre-expanded internal mammary artery perforator flap in large chest keloids surgical treatment.Methods:Patients with large chest keloid were treated with the pre-expanded internal mammary artery perforator flap between January 2017 and September 2021. The surgical treatment was divided into two different phases. In the first phase, a tissue expander was implanted beneath the skin within the angiosome of the internal mammary artery perforator. The expander was injected with normal saline once a week. In the second phase, the expander and the keloid tissue were removed, and a pre-expanded internal mammary artery perforator flap was designed to cover the wound. Radiotherapy and hyperbaric oxygen therapy were performed in the postoperative period. The treatment effect was followed up. The postoperative complications were analyzed, and the recurrence and patient satisfaction rates were recorded.Results:A total of 41 patients were enrolled, including 20 male and 21 female patients. The patients’ age ranged from 24 to 64, with a mean disease history of 11.9 years. The mean size of the keloid was 9 cm × 8 cm. Some patients were treated with one expander, but four expanders were needed in some extensive cases. The volume of the expander ranged from 80 to 600 ml. The mean volume was 300 ml, with a mean expansion time of 3 months. The mean flap size was 9 cm × 8 cm. Two cases with distal necrosis were observed. Five cases suffered from partial incision scar hyperplasia. No recurrence occurred during the followed-up period. Thirty-six patients (87.8%) were satisfied with the operation effect, and five (12.2%) thought the effect was acceptable.Conclusions:The pre-expanded internal mammary artery perforator flap is an effective treatment for the large chest keloid. It can provide sufficient skin tissue for wound repair, with a stable blood supply and an excellent curative effect.
2.Reconstruction of 41 cases of large chest keloids with the pre-expanded internal mammary artery perforator flap
Zheng QI ; Tian MENG ; Kexin SONG ; Cheng FENG ; Zhengyun LIANG ; Wenbo LI ; Fuquan ZHANG ; Lingyan KONG ; Ning DING ; Youbin WANG
Chinese Journal of Plastic Surgery 2022;38(6):635-639
Objective:To analyze the clinical effects of the pre-expanded internal mammary artery perforator flap in large chest keloids surgical treatment.Methods:Patients with large chest keloid were treated with the pre-expanded internal mammary artery perforator flap between January 2017 and September 2021. The surgical treatment was divided into two different phases. In the first phase, a tissue expander was implanted beneath the skin within the angiosome of the internal mammary artery perforator. The expander was injected with normal saline once a week. In the second phase, the expander and the keloid tissue were removed, and a pre-expanded internal mammary artery perforator flap was designed to cover the wound. Radiotherapy and hyperbaric oxygen therapy were performed in the postoperative period. The treatment effect was followed up. The postoperative complications were analyzed, and the recurrence and patient satisfaction rates were recorded.Results:A total of 41 patients were enrolled, including 20 male and 21 female patients. The patients’ age ranged from 24 to 64, with a mean disease history of 11.9 years. The mean size of the keloid was 9 cm × 8 cm. Some patients were treated with one expander, but four expanders were needed in some extensive cases. The volume of the expander ranged from 80 to 600 ml. The mean volume was 300 ml, with a mean expansion time of 3 months. The mean flap size was 9 cm × 8 cm. Two cases with distal necrosis were observed. Five cases suffered from partial incision scar hyperplasia. No recurrence occurred during the followed-up period. Thirty-six patients (87.8%) were satisfied with the operation effect, and five (12.2%) thought the effect was acceptable.Conclusions:The pre-expanded internal mammary artery perforator flap is an effective treatment for the large chest keloid. It can provide sufficient skin tissue for wound repair, with a stable blood supply and an excellent curative effect.
3.Initial Experience of the Application of Third-generation Dual-source CT Scanner in High-pitch Angiography of Aorta.
Jixiang LIANG ; Lingyan KONG ; Zhengyu JIN ; Yun WANG ; Huadan XUE ; Yining WANG ; Daming ZHANG ; Jin CHEN
Acta Academiae Medicinae Sinicae 2017;39(1):68-73
Objective To evaluate the value of third-generation dual-source CT scanner in application of high-pitch aorta CT angiography(CTA). Methods Totally 59 patients clinically indicated for whole aorta angiography were divided into 2 groups using a simple random method:in group 1 there were 28 patients who underwent the examination on a third-generation dual-source CT device,with a collimation of 2×192×0.6 mm and a rotation time of 0.25 s;in group 2 there were 31 patients who underwent the examination on a second generation dual-source CT device,with a collimation of 2×128×0.6 mm and a rotation time of 0.28 s. Both groups were given the examination operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,a tube voltage of 100 kV,and automated tube current modulation using a reference tube current of 288 mA. A contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser in 5.0 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose(ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 19.44% lower (t=-3.989,P=0.000) in group 1 [(3.15±0.86)mSv] than in group 2 [(3.91±0.60)mSv]. These two groups showed no significant differences in SNR or CNR (all P >0.05). The subjective diagnostic quality values also showed no significant difference between two groups [(1.39±0.50)scores vs. (1.45±0.51)scores;W=814.5,P=0.651].Conclusion Compared with the second-generation dual-source CT scanner,the third-generation dual-source CT scanner in whole aorta CTA can remarkably reduce the radiation dose without affecting image quality.
Aorta
;
diagnostic imaging
;
Computed Tomography Angiography
;
methods
;
Humans
;
Radiation Dosage
;
Retrospective Studies
;
Signal-To-Noise Ratio
4.Initial Experience of the Application of Automated Tube Potential Selection Technique in High-pitch Dual-source CT Angiography of Whole Aorta Using Third-generation Dual-source CT Scanner.
Lingyan KONG ; Jixiang LIANG ; Huadan XUE ; Yining WANG ; Yun WANG ; Zhengyu JIN ; Daming ZHANG ; Jin CHEN
Acta Academiae Medicinae Sinicae 2017;39(1):62-67
Objective To evaluate the application of automated tube potential selection technique in high-pitch dual-source CT aortic angiography on a third-generation dual-source CT scanner. Methods Whole aorta angiography were indiated in 59 patients,who were divided into 2 groups using a simple random method:in group 1 there were 31 patients who underwent the examination with automated tube potential selection using a vascular setting with a preferred image quality of 288 mA/100 kV;in group 2 there were 28 patients who underwent the examination with a tube voltage of 100 kV and automated tube current modulation using a reference tube current of 288 mA. Both groups were scanned on a third generation dual-source CT device operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,collimation of 2×192×0.6 mm,and a rotation time of 0.25 s. Iterative reconstruction algorithm was used. For group 1,the volume and flow of contrast medium and chasing saline were adapted to the tube voltage. For group 2,a contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser at 5 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose (ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 21.3% lower (t=-3.099,P=0.000) in group 1 [(2.48±0.80) mSv] than in group 2 [(3.15±0.86) mSv]. Two groups showed no significant difference in attenuation,SD,SNR,or CNR at all evaluational parts of aorta (ascending aorta,aortic arch,diaphragmatic aorta,or iliac bifurcation)(all P>0.05). There was no significant difference in subjective diagnostic quality values of two groups [(1.41±0.50) scores vs. (1.39±0.50) scores;W=828.5,P=0.837]. Conclusion Compared with automated tube current modulation,the automated tube potential selection technique in aorta CT angiography on a third-generation dual-source CT can dramatically reduce radiation dose without affecting image quality.
Algorithms
;
Aorta
;
diagnostic imaging
;
Computed Tomography Angiography
;
methods
;
Humans
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
;
Signal-To-Noise Ratio
5.Application of 70 kV Third-generation High-pitch Dual-source Coronary CT Angiography in Patients with Different Body Mass Index.
Yan YI ; Jian CAO ; Lu LIN ; Lingyan KONG ; Shu JIANG ; Xiao LI ; Peijun LIU ; Ming WANG ; Man WANG ; Yun WANG ; Zhengyu JIN ; Yining WANG
Acta Academiae Medicinae Sinicae 2017;39(1):42-48
Objective To investigate the optimized range of body mass index (BMI) selection for patients undergoing 70 kV high-pitch dual-source coronary CT angiography (CCTA) on the third-generation dual-source CT (DSCT). Methods Patients undergoing prospective high-pitch ultra-low contrast media (CM) CCTA on the third-generation DSCT using the automatic tube voltage selection at 70 kV were included and divided into three groups:group A,with BMI≤24 kg/m;group B,with 24 kg/m
Body Mass Index
;
China
;
Computed Tomography Angiography
;
methods
;
Contrast Media
;
Heart Rate
;
Humans
;
Prospective Studies
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
;
Signal-To-Noise Ratio
6.Application of the Low-dose One-stop-shop Cardiac CT Protocol with Third-generation Dual-source CT.
Lu LIN ; Yining WANG ; Yan YI ; Jian CAO ; Lingyan KONG ; Hao QIAN ; Hongzhi ZHANG ; Wei WU ; Yun WANG ; Zhengyu JIN
Acta Academiae Medicinae Sinicae 2017;39(1):34-41
Objective To evaluate the feasibility of a low-dose one-stop-shop cardiac CT imaging protocol with third-generation dual-source CT (DSCT). Methods Totally 23 coronary artery disease (CAD) patients were prospectively enrolled between March to September in 2016. All patients underwent an ATP stress dynamic myocardial perfusion imaging (MPI) (data acquired prospectively ECG-triggered during end systole by table shuttle mode in 32 seconds) at 70 kV combined with prospectively ECG-triggered high-pitch coronary artery angiography (CCTA) on a third-generation DSCT system. Myocardial blood flow (MBF) was quantified and compared between perfusion normal and abnormal myocardial segments based on AHA-17-segment model. CCTA images were evaluated qualitatively based on SCCT-18-segment model and the effective dose(ED) was calculated. In patients with subsequent catheter coronary angiography (CCA) as reference,the diagnosis performance of MPI (for per-vessel ≥50% and ≥70% stenosis) and CCTA (for≥50% stenosis) were assessed. Results Of 23 patients who had completed the examination of ATP stress MPI plus CCTA,12 patients received follow-up CCA. At ATP stress MPI,77 segments (19.7%) in 13 patients (56.5%) had perfusion abnormalities. The MBF values of hypo-perfused myocardial segments decreased significantly compared with normal segments [(93±22)ml/(100 ml·min) vs. (147±27)ml/(100 ml·min);t=15.978,P=0.000]. At CCTA,93.9% (308/328) of the coronary segments had diagnostic image quality. With CCA as the reference standard,the per-vessel and per-segment sensitivity,specificity,and accuracy of CCTA for stenosis≥50% were 94.1%,93.5%,and 93.7% and 90.9%,97.8%,and 96.8%,and the per-vessel sensitivity,specificity and accuracy of ATP stress MPI for stenosis≥50% and ≥70% were 68.7%,100%,and 89.5% and 91.7%,100%,and 97.9%. The total ED of MPI and CCTA was (3.9±1.3) mSv [MPI:(3.5±1.2) mSv,CCTA:(0.3±0.1) mSv]. Conclusion The third-generation DSCT stress dynamic MPI at 70 kV combined with prospectively ECG-triggered high-pitch CCTA is a feasible and reliable tool for clinical diagnosis,with remarkably reduced radiation dose.
Computed Tomography Angiography
;
methods
;
Coronary Artery Disease
;
diagnostic imaging
;
Heart
;
diagnostic imaging
;
Humans
;
Myocardial Perfusion Imaging
;
Prospective Studies
;
Radiation Dosage
;
Sensitivity and Specificity
7.Effect of age at cochlear implantation on auditory performance at the early stage after surgery in infants.
Jiajia CHENG ; Xueqing CHEN ; Bo LIU ; Sha LIU ; Lingyan MO ; Ying KONG ; Haihong LIU ; Beier QI ; Ruijuan DONG ; Yuling LI ; Shuo WANG ; Yanjun WU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2012;26(13):595-597
OBJECTIVE:
To evaluate the auditory performance of infants with cochlear implants at the early stage after surgery, summarize the development of auditory ability, investigate the effect of age at cochlear implantation on auditory performance within the first year after surgery and provide a reference for their habilitation program.
METHOD:
A total of 272 infants with prelingually profound hearing loss participated in this study, ranging in age at cochlear implantation from 18 to 36 months. The mean age was 21 months with a standard deviation of 7 months. Infants with cochlear implants were divided into three groups according to their age at implantation. Infants in group A were implanted under 18 months of age. Infants in group B were implanted between 18 and 24 months of age. Infants in group C were implanted between 25 and 36 months of age. Categories of auditory performance (CAP) was used to evaluate the auditory performance, which rates auditory abilities in eight categories for a scale of 0 to 7.
RESULT:
The mean scores of CAP for all infants at each interval were significantly different after implantation. Significant differences were observed in mean scores of CAP among these three groups in 1 and 3 months after switch-on. However there were no significant differences in pre-operation, 6, 9 and 12 months after switch-on.
CONCLUSION
There is a significant improvement in auditory performance of infants with prelingually profound hearing loss within the first year after cochlear implantation. The age at cochlear implantation has no critical influence on the development of auditory capabilities at the early stage after surgery. CAP is a practical tool which can be used in clinic in China.
Age Factors
;
Child, Preschool
;
Cochlear Implantation
;
Cochlear Implants
;
Deafness
;
surgery
;
Female
;
Hearing
;
Humans
;
Infant
8.The effects of hearing level on auditory performance in infants with hearing aids.
Xueqing CHEN ; Jing LI ; Yanjun WU ; Hua ZHANG ; Haihong LIU ; Shuo WANG ; Ying KONG ; Sha LIU ; Bo LIU ; Lingyan MO ; Beier QI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2012;26(23):1080-1082
OBJECTIVE:
The purpose of this study is to investigate the effects of hearing level on auditory performance in infants with hearing aids and provide a clinical database for their hearing and speech habilitation.
METHOD:
A total of 32 infants with prelingual hearing loss participated in this study, ranging in age at hearing aid fitting from 3 to 34 months with a mean of 16 months. According to their hearing level, they were divided into three groups. Infants in group A were with moderate hearing loss (41-60 dB HL). Infants in group B were with severe hearing loss (61-80 dB HL). Infants in group C were with profound hearing loss (>81 dB HL). The infant-toddler meaningful auditory integration scale (IT-MAIS) was used to evaluate their auditory performance. The evaluation was performed before hearing aid fitting and 1, 3, 6, 9, 12 months after fitting.
RESULT:
The mean scores of auditory performance showed significant improvements with time of hearing aid use for the three groups of infants (P < 0.05). The mean score of auditory performance for group A at 3 months after fitting was significantly superior in comparison with the scores before hearing aid fitting and at 1 month after fitting (P < 0.05). The mean score of auditory performance for group B at 6 months after fitting was significantly superior in comparison with the scores before hearing aid fitting and at 1, 3 months after fitting (P < 0.05). The mean score of auditory performance for group C at 9 months after fitting was significantly superior in comparison with the scores before hearing aid fitting and at 1, 3, 6 months after fitting (P < 0.05). There were no significant differences in mean scores between group A and B at each evaluating interval (P > 0.05). However, significant differences were observed between group A and C at 3, 6, 9, 12 months after fitting (P < 0.05). Significant differences were also shown between group B and C at 1, 3, 6, 9, 12 months after fitting (P < 0.05).
CONCLUSION
Auditory performance of infants with prelingual hearing loss developed significantly with the use of hearing aids within the first year after fitting. The degree of hearing loss in infants had significant influence on the development of auditory performance.
Child, Preschool
;
Deafness
;
rehabilitation
;
Female
;
Hearing
;
Hearing Aids
;
Hearing Tests
;
Humans
;
Infant
;
Male
9.The characteristics and development of auditory skill for infants with different age after cochlear implantation.
Xueqing CHEN ; Sha LIU ; Ying KONG ; Bo LIU ; Lingyan MO ; Haihong LIU ; Shuo WANG ; Yanjun WU ; Beier QI ; Jing LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2009;23(4):148-150
OBJECTIVE:
To analyze the characteristics and development of auditory skill for infants with different age before and after cochlear implantation by using infant-toddler meaningful auditory integration scale (IT-MAIS) questionnaire, and provide the useful information for the criteria of candidacy for cochlear implantation in infants and habilitation after cochlear implantation.
METHOD:
One hundred and thirty-nine prelingually infants with profound hearing loss were included in this study. According to the age at implantation, the infants were divided into 5 groups. They were group A ( < or =12 months), B (13-18 months), C (19-24 months), D (25-30 months) and E (31-36 months). Audiologists who were trained before this study used the IT-MAIS questionnaire to evaluate the auditory skill for all the infants and asked for the parents' or guardians' answers face to face. All the information about the infants spontaneous auditory behavioural responses was recorded in detail. The evaluation was performed before operation and 1 month, 3 months, 6 months, 12 months after switch-on.
RESULT:
There were no significant differences in mean scores over time between different gender who received cochlear implants by Independent-Samples T Test (P > 0.05). There were no significant differences in mean scores over time among the 5 groups by Multiple Comparison in ANOVA (P > 0.05). The scores were increased with time and there were significant differences in mean scores among the different time before and after switch-on by Multiple Comparison in ANOVA (P < 0.05) for each group.
CONCLUSION
The development of the auditory skill for infants followed the same rate in different gender. The auditory skill for infants after cochlear implantation developed rapidly regardless of age at implantation. Most of infants indicated rapid improvement in auditory skill within the first 6 months after switch-on, and then showed relative slow increase in the following 6 months.
Age Distribution
;
Auditory Perception
;
Child, Preschool
;
Cochlear Implantation
;
Cochlear Implants
;
Female
;
Humans
;
Infant
;
Language Development
;
Male
;
Persons With Hearing Impairments
;
rehabilitation
;
Treatment Outcome
10.The impact of heart rate on image quality and reconstruction timing of dual-source CT coronary angiography
Yining WANG ; Zhengyu JIN ; Lingyan KONG ; Zhuhua ZHANG ; Lan SONG ; Shuyang ZHANG ; Songbai LIN ; Wenbin MOU ; Yun WANG ; Wenmin ZHAO
Chinese Journal of Radiology 2008;42(2):119-122
ObjectiveTo evaluate the impact of patient's heart rate(HR)on coronary CT angiography(CTA)image quality(IQ)and reconstruction timing in dual-source CT(DSCT).Methods Ninety-five patients with suspicion of coronary artery disease were examined with a DSCT scanner(Somatom Definition.Siemens)using 32×0.6 mm collimation.All patients were divided three groups according to the heart rate(HR):group 1,HR≤70 beats per minute(bpm),n=26;group 2,HR>70 bpm to≤90 bpm, n=37;group 3,HR>90 bpm,n=32. No beta-blockers were taken before CT scan.50-60 ml of nonionic contrast agent were injected with a rate of 5 ml/s. Images were reconstructed from 10%to 100% of the R-R interval using single-segment reconstruction. Two readers independently assessed IQ of all coronary segments using a 3-point scale from excellent(1)to non-assessable(3)for coronary segments and the relationshiD between IQ and the HR. ResuitsOverall mean IQ score was 1.31 ±0.55 for all patients with 1.08±0.27 for group 1,1.32±0.58 for group 2 and 1.47±0.61 for group 3. The IQ was better in the LAD than the RCA and LCX(P<0.01).Only 1.4%(19/1386)of coronary artery segments were considered non-assessable due to the motion artifacts.Optimal image quality of all coronary segments in 74 patients(77.9%)can be achieved with one reconstruction data set.The best IQ was predominately in diastote(88.5%)in group 1,while the best IQ was in systole(84.4%)in group 3. ConclusionsDSCT can achieve the optimal IQ with a wide range of HR using single-segment reconstruction. With the increasing of HR,the timing of data reconstruction for the best IQ shifts from mid-diastole to systole.

Result Analysis
Print
Save
E-mail