1.Value of the five-sectional screening method of the central nervous system in the first trimester
Lingling SUN ; Chunya JI ; Jun ZHANG ; Qi PAN ; Zhong YANG ; Chen LING ; Linliang YIN ; Xuedong DENG
Chinese Journal of Ultrasonography 2025;34(5):383-390
Objective:To investigate the value of the five-sectional screening method of the central nervous system(CNS)in early detection of fetal CNS abnormalities during the first trimester.Methods:The data of pregnant women who underwent nuchal translucency(NT)screening at the Affiliated Suzhou Hospital of Nanjing Medical University from September 2018 to September 2023 were retrospectively analyzed. And a five-sectional screening method of CNS was performed in all fetuses at the meantime. The five-sectional screening protocol in the first trimester consists of the mid-sagittal plane of the fetal head,trans-ventricular plane,trans-thalamus plane,axial plane of the fetal head at the posterior fossa level,and the sagittal plane of the fetal spine. All fetuses underwent ultrasound screening during the second trimester and the third trimester sequentially after NT screening. All the ultrasound findings were tracked,and all fetuses were followed up until delivery or after induction. Fetuses with CNS abnormalities found or suspected in the first trimester were reviewed by at least one senior physician,and follow-up examinations were routinely performed after 2 weeks to further confirm the diagnosis or find other abnormalities that may be present.Results:A total of 13 679 fetuses were screened,included 11 415 singleton pregnancies and 1 132 twin pregnancies. Among them,there were 289 cases of missed follow-up and unexplained fetal death,included 263 singleton pregnancies and 13 twin pregnancies. A total of 13 390 fetuses were finally included,among which,35 cases developed CNS abnormalities with 34 cases detected by prenatal ultrasound and 1 case of closed spina bifida missed in prenatal diagnosis,and the detection rate of CNS malformation by prenatal ultrasound was 97.14%(34/35). Of the 35 fetuses with CNS abnormalities,24 were detected by the CNS five-sectional screening method in the first trimester,with a sensitivity of 68.57%,a specificity of 100%,a positive predictive value of 100%,and a negative predictive value of 99.92%. Among them,there were 2 cases of anencephaly,3 cases of exencephaly and 6 cases of encephalocele were all detected in the first trimester. In addition,6 cases of holoprosencephaly,3 cases of severe ventriculomegaly,2 cases of open spina bifida,and 2 cases of Dandy-Walker malformation were detected in the first trimester. In this study,1 case of agenesis of corpus callosum(ACC),1 case of arachnoid cyst,1 case of lissencephaly,1 case of schizencephaly,and 1 case of mega cisterna magna were not detected in early pregnancy.Conclusions:The fetal five-sectional screening method of CNS in the first trimester has high specificity,positive predictive value and negative predictive value for the detection of fetal CNS abnormalities,but the sensitivity is moderate. The five-sectional screening method for CNS in early pregnancy may be an effective method for early detection of fetal CNS abnormalities.
2.Diagnostic value of fetal cardiac ultrasound screening views in the first trimester for congenital heart disease
Chengcheng WU ; Chunya JI ; Liqun FENG ; Wei SHAO ; Naimin SUN ; Jun ZHANG ; Zhong YANG ; Chen LING ; Lingling SUN ; Qi PAN ; Xuedong DENG ; Linliang YIN
Chinese Journal of Ultrasonography 2025;34(9):799-804
Objective:To investigate the diagnostic value of fetal cardiac ultrasound view visualization in the first trimester for congenital heart disease(CHD).Methods:A retrospective analysis was performed on 13 323 singleton fetuses who underwent first-trimester(11-13 +6 weeks)ultrasound screening at the Ultrasound Medicine Center,the Affiliated Suzhou Hospital of Nanjing Medical University from January 2018 to June 2024. Cardiac views including the four-chamber view(4CV),left ventricular outflow tract view(LVOT),and Results:The study group showed significantly higher rates of "poorly visualized" 4CV,LVOT,and 3VT than the control group(2.70% vs. 0.14%, P=0.005;36.49% vs. 4.76%, P<0.001;36.49% vs.2.46%, P<0.001). The efficacies of combination 1(any view abnormal)and combination 2(any view "poorly visualized" or "abnormal")were comparable,with AUCs of 0.86 and 0.85( P=0.424). The AUCs of combination 3(3VT "poorly visualized" or any view "abnormal")and combination 4(4CV "poorly visualized" or any view "abnormal")were 0.88 and 0.86( P=0.424),all significantly higher than combination 5(LVOT "poorly visualized" or any view "abnormal",AUC=0.84,all P<0.05). Conclusions:"Poorly visualized" cardiac views in the first trimester demonstrate good diagnostic efficacy for CHD,particularly when 3VT or 4CV are affected,warranting heightened clinical vigilance for fetal cardiac anomalies.
3.Relationship of peripheral blood PCⅢ and HPX levels with blood lipid and liver fibrosis in patients with nonalcoholic steatohepatitis
Liangyu SHI ; Tingting JI ; Lei LEI ; Lingling WANG ; Simin WEN
International Journal of Laboratory Medicine 2025;46(2):175-179
Objective To investigate the relationship between the levels of type Ⅲ procollagen(PCⅢ)and heme-binding protein(HPX)in peripheral blood,blood lipid and liver fibrosis in patients with nonalcoholic steatohepatitis(NASH).Methods Totally 126 patients with NASH admitted to the hospital from January 2021 to December 2023 were selected as NASH group,and they were divided into 3 subgroups according to the degree of liver fibrosis:no liver fibrosis group(22 cases),mild group(63 cases),moderate and severe group(41 cases).In addition,150 healthy subjects in the same period were selected as the control group.Enzyme-linked immunosorbent assay(ELISA)was used to detect and compare the levels of PC Ⅲ and HPX in periph-eral blood of all groups,and Pearson correlation analysis was used to explore the correlation between peripher-al blood PC Ⅲ and HPX levels and related indexes of blood lipids in NASH patients.The predictive value of peripheral blood PC Ⅲ and HPX for liver fibrosis in NASH patients was evaluated by receiver operating char-acteristic(ROC)curve.Results The levels of PC Ⅲ and HPX,as well as total cholesterol(TC),triglyceride(TG)and low density lipoprotein cholesterol(LDL-C)in NASH group were higher than those in control group,and the levels of high density lipoprotein cholesterol(HDL-C)were lower than those in control group,and the differences were statistically significant(P<0.05).Pearson correlation analysis showed that the lev-els of PCⅢ and HPX in peripheral blood of NASH patients were positively correlated with TC,TG and LDL-C(P<0.05),while negatively correlated with HDL-C(P<0.05).The levels of PC Ⅲ and HPX in peripheral blood of the non-fibrosis group were lower than those of the mild and moderate severe groups,and the mild group was lower than that of the moderate and severe group,and the differences were statistically significant(P<0.05).The area under the curve(AUC)of peripheral blood PC Ⅲ and HPX in predicting liver fibrosis in NASH patients were 0.757 and 0.861,respectively,and the cut-off values were 135.51 ng/mL and 804.86 mg/L,respectively.The AUC of the combined prediction for liver fibrosis was 0.905,which was higher than that predicted by the two alone.Conclusion The level of PC Ⅲ and HPX in peripheral blood is closely related to the level of blood lipids and the degree of liver fibrosis in NASH patients,which can be used as potential bi-omarkers to predict liver fibrosis in NASH patients.
4.History, Experience, Opportunities, and Challenges in Esophageal Cancer Prevention and Treatment in Linxian, Henan Province, A High Incidence Area for Esophageal Cancer
Lidong WANG ; Xiaoqian ZHANG ; Xin SONG ; Xueke ZHAO ; Duo YOU ; Lingling LEI ; Ruihua XU ; Jin HUANG ; Wenli HAN ; Ran WANG ; Qide BAO ; Aifang JI ; Lei MA ; Shegan GAO
Cancer Research on Prevention and Treatment 2025;52(4):251-255
Linxian County in Henan Province, Northern China is known as the region with the highest incidence and mortality rate of esophageal cancer worldwide. Since 1959, the Henan medical team has conducted field work on esophageal cancer prevention and treatment in Linxian. Through three generations of effort exerted by oncologists over 65 years of research on esophageal cancer prevention and treatment in Linxian, the incidence rate of esophageal squamous cell carcinoma in this area has dropped by nearly 50%, and the 5-year survival rate has increased to 40%, reaching the international leading
5.Value of the five-sectional screening method of the central nervous system in the first trimester
Lingling SUN ; Chunya JI ; Jun ZHANG ; Qi PAN ; Zhong YANG ; Chen LING ; Linliang YIN ; Xuedong DENG
Chinese Journal of Ultrasonography 2025;34(5):383-390
Objective:To investigate the value of the five-sectional screening method of the central nervous system(CNS)in early detection of fetal CNS abnormalities during the first trimester.Methods:The data of pregnant women who underwent nuchal translucency(NT)screening at the Affiliated Suzhou Hospital of Nanjing Medical University from September 2018 to September 2023 were retrospectively analyzed. And a five-sectional screening method of CNS was performed in all fetuses at the meantime. The five-sectional screening protocol in the first trimester consists of the mid-sagittal plane of the fetal head,trans-ventricular plane,trans-thalamus plane,axial plane of the fetal head at the posterior fossa level,and the sagittal plane of the fetal spine. All fetuses underwent ultrasound screening during the second trimester and the third trimester sequentially after NT screening. All the ultrasound findings were tracked,and all fetuses were followed up until delivery or after induction. Fetuses with CNS abnormalities found or suspected in the first trimester were reviewed by at least one senior physician,and follow-up examinations were routinely performed after 2 weeks to further confirm the diagnosis or find other abnormalities that may be present.Results:A total of 13 679 fetuses were screened,included 11 415 singleton pregnancies and 1 132 twin pregnancies. Among them,there were 289 cases of missed follow-up and unexplained fetal death,included 263 singleton pregnancies and 13 twin pregnancies. A total of 13 390 fetuses were finally included,among which,35 cases developed CNS abnormalities with 34 cases detected by prenatal ultrasound and 1 case of closed spina bifida missed in prenatal diagnosis,and the detection rate of CNS malformation by prenatal ultrasound was 97.14%(34/35). Of the 35 fetuses with CNS abnormalities,24 were detected by the CNS five-sectional screening method in the first trimester,with a sensitivity of 68.57%,a specificity of 100%,a positive predictive value of 100%,and a negative predictive value of 99.92%. Among them,there were 2 cases of anencephaly,3 cases of exencephaly and 6 cases of encephalocele were all detected in the first trimester. In addition,6 cases of holoprosencephaly,3 cases of severe ventriculomegaly,2 cases of open spina bifida,and 2 cases of Dandy-Walker malformation were detected in the first trimester. In this study,1 case of agenesis of corpus callosum(ACC),1 case of arachnoid cyst,1 case of lissencephaly,1 case of schizencephaly,and 1 case of mega cisterna magna were not detected in early pregnancy.Conclusions:The fetal five-sectional screening method of CNS in the first trimester has high specificity,positive predictive value and negative predictive value for the detection of fetal CNS abnormalities,but the sensitivity is moderate. The five-sectional screening method for CNS in early pregnancy may be an effective method for early detection of fetal CNS abnormalities.
6.Diagnostic value of fetal cardiac ultrasound screening views in the first trimester for congenital heart disease
Chengcheng WU ; Chunya JI ; Liqun FENG ; Wei SHAO ; Naimin SUN ; Jun ZHANG ; Zhong YANG ; Chen LING ; Lingling SUN ; Qi PAN ; Xuedong DENG ; Linliang YIN
Chinese Journal of Ultrasonography 2025;34(9):799-804
Objective:To investigate the diagnostic value of fetal cardiac ultrasound view visualization in the first trimester for congenital heart disease(CHD).Methods:A retrospective analysis was performed on 13 323 singleton fetuses who underwent first-trimester(11-13 +6 weeks)ultrasound screening at the Ultrasound Medicine Center,the Affiliated Suzhou Hospital of Nanjing Medical University from January 2018 to June 2024. Cardiac views including the four-chamber view(4CV),left ventricular outflow tract view(LVOT),and Results:The study group showed significantly higher rates of "poorly visualized" 4CV,LVOT,and 3VT than the control group(2.70% vs. 0.14%, P=0.005;36.49% vs. 4.76%, P<0.001;36.49% vs.2.46%, P<0.001). The efficacies of combination 1(any view abnormal)and combination 2(any view "poorly visualized" or "abnormal")were comparable,with AUCs of 0.86 and 0.85( P=0.424). The AUCs of combination 3(3VT "poorly visualized" or any view "abnormal")and combination 4(4CV "poorly visualized" or any view "abnormal")were 0.88 and 0.86( P=0.424),all significantly higher than combination 5(LVOT "poorly visualized" or any view "abnormal",AUC=0.84,all P<0.05). Conclusions:"Poorly visualized" cardiac views in the first trimester demonstrate good diagnostic efficacy for CHD,particularly when 3VT or 4CV are affected,warranting heightened clinical vigilance for fetal cardiac anomalies.
7.C-arm CT stent precision technology in intracranial arterial stent implantation
Ji YIN ; Li ZHU ; Xiaolin HOU ; Lingling ZHANG ; Jingke YU
Chinese Journal of Medical Imaging Technology 2025;41(2):331-335
Objective To observe the value of C-arm CT stent precision technology in intracranial arterial stent implantation.Methods Data of 38 patients with symptomatic intracranial atherosclerotic stenosis who underwent intracranial arterial stent implantation were retrospectively analyzed.Stent displayed in 2D-digital subtraction angiography(DSA)during and immediately after implantation were observed,and superselective C-arm CT scanning of target artery and stent precision reconstruction were performed.Subjective scoring of display stent structure in 2D-DSA and stent precision reconstruction images were comparatively analyzed,and the clarity rate of displaying stent and detection rate of related complications were compared.Results Totally 45 stents were implanted in 38 patients.In 2D-DSA,the subjective score was 0 of 1,1 of 20 and 2 of 24 stents,respectively.Stent precision reconstruction image showed that subjective score was 0 of 1 stent and was 3 of 44 stents.The clarity rate of displaying stent in stent precision reconstruction image was 97.78%(44/45),much higher than that of 2D-DSA image(0[0/45],P<0.001).Among 44 stents displayed in 2D-DSA,poor stent opening and abnormal perforator vessel was observed in each 1 stent,and no clear abnormality was found in the rest stents.Among 44 stents revealed in stent precision reconstruction images,poor stent opening,thromboses in stent and stent mesh protruding into vascular lumen were found each in 2 stents,while perforator vessel spasm and localized stenosis after stent implantation were noticed in 3 stents.Arterial dissection occurred in 8 stents during balloon dilation,after timely implantation of a new stent,stent precision reconstruction images showed the dissection rupture was completely covered.The complications of stent precision reconstruction was higher than that of 2D-DSA(38.64%[17/44]vs.4.55%[2/44].P=0.002).Conclusion C-arm CT stent precision technique had obvious advantages for intracranial artery stent implantation.
8.Static compressive stress accelerting autophagy of human ligament cells in three-dimensional culture
Shiyang WU ; Xueping KANG ; Rui ZOU ; Zhen CHAI ; Lingling JI
Journal of Practical Stomatology 2025;41(2):189-192
Objective:To establish a three-dimensional culture and stress-loaded model of human periodontal ligament cells(hP-DLCs)in vitro and to determine the effect of static pressure on autophagy.Methods:Periodontal tissue was scraped from fresh ex-tracted tooth surfaces for culture and hPDLCs were obtained.Type Ⅰ rat tail collagen was extracted to prepare collagen-sodium algi-nate composite hydrogel,in which third-generation hPDLCs were embedded.After 72 h of culture,gene expression of autophagy-related proteins LC3,Atg-5 and Beclin-1 was detected by quantitative real-time polymerase chain reaction(qRT-PCR),and the expression of Atg-5,Beclin-1 and LC3 was detected by Western blotting.Results:Cells grew well in collagen-alginate hydrogels.After 15 min of compressive stress loading,the level of autophagy of hPDLCs increased significantly and then gradually decreased to the baseline level.Conclusion:Collagen-alginate hydrogel has good biocompatibility and safety,and can be used as an excellent scaffold for three-dimensional cell culture in vitro.Static compressive stress can accelevate autophagy,and this acceleration is rapid and short-lived.
9.Static compressive stress accelerting autophagy of human ligament cells in three-dimensional culture
Shiyang WU ; Xueping KANG ; Rui ZOU ; Zhen CHAI ; Lingling JI
Journal of Practical Stomatology 2025;41(2):189-192
Objective:To establish a three-dimensional culture and stress-loaded model of human periodontal ligament cells(hP-DLCs)in vitro and to determine the effect of static pressure on autophagy.Methods:Periodontal tissue was scraped from fresh ex-tracted tooth surfaces for culture and hPDLCs were obtained.Type Ⅰ rat tail collagen was extracted to prepare collagen-sodium algi-nate composite hydrogel,in which third-generation hPDLCs were embedded.After 72 h of culture,gene expression of autophagy-related proteins LC3,Atg-5 and Beclin-1 was detected by quantitative real-time polymerase chain reaction(qRT-PCR),and the expression of Atg-5,Beclin-1 and LC3 was detected by Western blotting.Results:Cells grew well in collagen-alginate hydrogels.After 15 min of compressive stress loading,the level of autophagy of hPDLCs increased significantly and then gradually decreased to the baseline level.Conclusion:Collagen-alginate hydrogel has good biocompatibility and safety,and can be used as an excellent scaffold for three-dimensional cell culture in vitro.Static compressive stress can accelevate autophagy,and this acceleration is rapid and short-lived.
10.C-arm CT stent precision technology in intracranial arterial stent implantation
Ji YIN ; Li ZHU ; Xiaolin HOU ; Lingling ZHANG ; Jingke YU
Chinese Journal of Medical Imaging Technology 2025;41(2):331-335
Objective To observe the value of C-arm CT stent precision technology in intracranial arterial stent implantation.Methods Data of 38 patients with symptomatic intracranial atherosclerotic stenosis who underwent intracranial arterial stent implantation were retrospectively analyzed.Stent displayed in 2D-digital subtraction angiography(DSA)during and immediately after implantation were observed,and superselective C-arm CT scanning of target artery and stent precision reconstruction were performed.Subjective scoring of display stent structure in 2D-DSA and stent precision reconstruction images were comparatively analyzed,and the clarity rate of displaying stent and detection rate of related complications were compared.Results Totally 45 stents were implanted in 38 patients.In 2D-DSA,the subjective score was 0 of 1,1 of 20 and 2 of 24 stents,respectively.Stent precision reconstruction image showed that subjective score was 0 of 1 stent and was 3 of 44 stents.The clarity rate of displaying stent in stent precision reconstruction image was 97.78%(44/45),much higher than that of 2D-DSA image(0[0/45],P<0.001).Among 44 stents displayed in 2D-DSA,poor stent opening and abnormal perforator vessel was observed in each 1 stent,and no clear abnormality was found in the rest stents.Among 44 stents revealed in stent precision reconstruction images,poor stent opening,thromboses in stent and stent mesh protruding into vascular lumen were found each in 2 stents,while perforator vessel spasm and localized stenosis after stent implantation were noticed in 3 stents.Arterial dissection occurred in 8 stents during balloon dilation,after timely implantation of a new stent,stent precision reconstruction images showed the dissection rupture was completely covered.The complications of stent precision reconstruction was higher than that of 2D-DSA(38.64%[17/44]vs.4.55%[2/44].P=0.002).Conclusion C-arm CT stent precision technique had obvious advantages for intracranial artery stent implantation.

Result Analysis
Print
Save
E-mail