1.Comparative study on accuracy of three imaging methods in diagnosis of subacromial impingement syndrome.
Linfeng ZI ; Hongfu JIN ; Jianwei ZHU ; Guoxu ZHANG ; Yao TONG ; Sijie CHEN ; Wenze SHAO ; Xin TANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1290-1295
OBJECTIVE:
To compare the diagnostic accuracy of supraspinatus muscle outlet X-ray film, oblique sagittal multislice helical CT (MSCT), and oblique sagittal MRI in the diagnosis of subacromial impingement syndrome (SIS).
METHODS:
A retrospective analysis was conducted on the imaging data of 106 patients diagnosed with SIS between January 2023 and December 2024. The cohort consisted of 32 males and 74 females, with ages ranging from 43 to 70 years (mean, 60.19 years). All patients underwent supraspinatus muscle outlet X-ray film, MSCT, and MRI scans, with MSCT further subjected to three-dimensional reconstruction. Two experienced radiologists independently evaluated the acromion morphology in each imaging modality using the Bigliani classification system. Inter-observer reliability was assessed via Kappa statistics. The CT three-dimensional reconstructions were used as the "gold standard". The overall consistency, Kappa values, sensitivity, and specificity of the three imaging modalities were calculated. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was computed.
RESULTS:
The inter-observer reliability for supraspinatus muscle outlet X-ray film, oblique sagittal MSCT, and oblique sagittal MRI was moderate, with Kappa values of 0.62, 0.63, and 0.55, respectively. When compared to the CT three-dimensional reconstructions as the "gold standard", the overall consistency was 88.7% (94/106), 62.3% (66/106), and 58.5% (62/106), respectively. The supraspinatus muscle outlet X-ray film showed excellent consistency (Kappa=0.77), whereas the consistency of MSCT and MRI was lower (Kappa=0.34 and 0.29, respectively). In terms of diagnostic sensitivity and specificity, the supraspinatus muscle outlet X-ray film outperformed oblique sagittal MSCT and oblique sagittal MRI in distinguishing various acromion types. ROC analysis demonstrated that the AUC for the supraspinatus muscle outlet X-ray film was consistently higher than for oblique sagittal MSCT and oblique sagittal MRI, with the highest diagnostic performance observed for type Ⅲ hooked acromion (AUC=0.939).
CONCLUSION
Supraspinatus muscle outlet X-ray film provides the highest diagnostic accuracy for acromion classification in SIS patients, particularly in identifying type Ⅲ hooked acromion, which is strongly associated with SIS. Given its superior sensitivity and consistency, it should be considered the primary screening tool. MSCT and MRI serve as valuable supplementary modalities for complex cases and preoperative evaluation.
Humans
;
Middle Aged
;
Male
;
Female
;
Shoulder Impingement Syndrome/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Retrospective Studies
;
Aged
;
Adult
;
Imaging, Three-Dimensional
;
Sensitivity and Specificity
;
Tomography, Spiral Computed/methods*
;
Multidetector Computed Tomography/methods*
;
Reproducibility of Results
2.Evaluation on the effect of Qinshan nuclear power station in normal operational condition on the environmental radioactivity in Shanghai city
Heqing LU ; Guoying ZHU ; Linfeng GAO ; Yaping ZI ; Lifang CHEN ; Yaofang SHEN ; Xiao LING ; Aijun QIAN
Chinese Journal of Radiological Medicine and Protection 2009;29(3):292-295
Objective To study the effect on the environmental radioactivity level and the health of the residents in Shanghai when Qinshan Nuclear Power Station(QNPS) has been in normal operational condition for 17 years. Methods The field monitoring and the sampling analytical method were used for monitoring the radioactivity level in outdoor environment, drinking water, food and soil. Results The outdoor natural radiation level and the radioactivity level in the sample of the environmental media were on the normal background level. There was no distinct change in the environmental radiation level of Jinshan Area when QNPS was in normal operational condition. The radioactivity level in the environmental media was far lower than the limit values specified by the national standard GB. The effective dose of the outdoor natural external exposure for the residents is about 0.102 mSv/a and the effective dose of the internal exposure from the artificial radionuclides 90Sr and 137Cs in food for the residents is about 0.488 μSv/a. Conclusions There is no effect of the radioactive contamination on the environmental radioactivity level and the health of the residents in Shanghai when QNPS has been in normal operational condition for 17 years.

Result Analysis
Print
Save
E-mail