1.Construction of a prognostic prediction model for invasive lung adenocarcinoma based on machine learning
Yanqi CUI ; Jingrong YANG ; Lin NI ; Duohuang LIAN ; Shixin YE ; Yi LIAO ; Jincan ZHANG ; Zhiyong ZENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):80-86
Objective To determine the prognostic biomarkers and new therapeutic targets of the lung adenocarcinoma (LUAD), based on which to establish a prediction model for the survival of LUAD patients. Methods An integrative analysis was conducted on gene expression and clinicopathologic data of LUAD, which were obtained from the UCSC database. Subsequently, various methods, including screening of differentially expressed genes (DEGs), Gene Ontology (GO), Kyoto Encyclopedia of Genes and Genomes (KEGG) analysis and Gene Set Enrichment Analysis (GSEA), were employed to analyze the data. Cox regression and least absolute shrinkage and selection operator (LASSO) regression were used to establish an assessment model. Based on this model, we constructed a nomogram to predict the probable survival of LUAD patients at different time points (1-year, 2-year, 3-year, 5-year, and 10-year). Finally, we evaluated the predictive ability of our model using Kaplan-Meier survival curves, receiver operating characteristic (ROC) curves, and time-dependent ROC curves. The validation group further verified the prognostic value of the model. Results The different-grade pathological subtypes' DEGs were mainly enriched in biological processes such as metabolism of xenobiotics by cytochrome P450, natural killer cell-mediated cytotoxicity, antigen processing and presentation, and regulation of enzyme activity, which were closely related to tumor development. Through Cox regression and LASSO regression, we constructed a reliable prediction model consisting of a five-gene panel (MELTF, MAGEA1, FGF19, DKK4, C14ORF105). The model demonstrated excellent specificity and sensitivity in ROC curves, with an area under the curve (AUC) of 0.675. The time-dependent ROC analysis revealed AUC values of 0.893, 0.713, and 0.632 for 1-year, 3-year, and 5-year survival, respectively. The advantage of the model was also verified in the validation group. Additionally, we developed a nomogram that accurately predicted survival, as demonstrated by calibration curves and C-index. Conclusion We have developed a prognostic prediction model for LUAD consisting of five genes. This novel approach offers clinical practitioners a personalized tool for making informed decisions regarding the prognosis of their patients.
2.Association between the diurnal rhythm amplitude of choroidal blood flow index and the progression of spherical equivalent and axial length in children
Ye YANG ; Zhiyang LIN ; Ziwei ZHOU ; Meixiao SHEN
International Eye Science 2025;25(5):858-862
AIM:To explore the relationship between the amplitude of diurnal variations in the choroidal vascular index(CVI)and annual changes in spherical equivalent(SE)and axial length in school-aged children.METHODS: Prospective study. Totally 39 cases(39 eyes)of Chinese school-age children aged 7 to 12 that diagnosed as emmetropia and myopia and error of refraction at optometry clinics of Eye Hospital, Wenzhou Medical University from July to August 2021 were selected. While 33 cases(33 eyes)were finally included, with 6 cases of loss to 1 a follow-up. A total of 16 cases(16 eyes)with annual growth of SE<0.5 D and 17 cases(17 eyes)with annual growth of SE≥0.5 D were divided into a non-progression group and progression group, respectively. Swept-source optical coherence tomography(SS-OCT)and custom choroidal analysis software were used to longitudinally observe diurnal variations in CVI of subjects, and the association between CVI diurnal amplitude and annual changes in SE and axial length was analyzed.RESULTS:It showed no significant correlation between the CVI diurnal amplitude at 1 mm from the fovea and annual changes in SE of the non-progressive group(P=0.65), while in the progression group, the CVI diurnal amplitude at 1 mm from the fovea was negatively correlated with annual changes in SE(P=0.048). However, no significant correlation was identified between CVI diurnal amplitude and annual changes in axial length in either group(all P>0.05). The diurnal amplitude of the CVI at the 1 mm foveal center had an effect on annual SE progression(P=0.039). Conversely, the diurnal amplitude of axial length, the annual changes in axial length, and the maximum or minimum time of CVI demonstrated significant associations with SE progression(all P> 0.05).CONCLUSION: Diurnal variations in CVI amplitude are associated with SE progression in school-aged children, providing a basis for further understanding the choroid-related changes in the process of myopia onset and progression.
3.Mitral valve re-repair with leaflet augmentation for mitral regurgitation in children: A retrospective study in a single center
Fengqun MAO ; Kai MA ; Kunjing PANG ; Ye LIN ; Benqing ZHANG ; Lu RUI ; Guanxi WANG ; Yang YANG ; Jianhui YUAN ; Qiyu HE ; Zheng DOU ; Shoujun LI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(07):958-962
Objective To investigate the efficacy of leaflet augmentation technique to repair the recurrent mitral valve (MV) regurgitation after mitral repair in children. Methods A retrospective analysis was conducted on the clinical data of children who underwent redo MV repair for recurrent regurgitation after initial MV repair, using a leaflet augmentation technique combined with a standardized repair strategy at Fuwai Hospital, Chinese Academy of Medical Sciences, from 2018 to 2022. The pathological features of the MV, key intraoperative procedures, and short- to mid-term follow-up outcomes were analyzed. Results A total of 24 patients (12 male, 12 female) were included, with a median age of 37.6 (range, 16.5–120.0) months. The mean interval from the initial surgery was (24.9±17.0) months. All children had severe mitral regurgitation preoperatively. The cardiopulmonary bypass time was (150.1±49.5) min, and the aortic cross-clamp time was (94.0±24.2) min. There were no early postoperative deaths. During a mean follow-up of (20.3±9.1) months, 3 (12.5%) patients developed moderate or severe mitral regurgitation (2 severe, 1 moderate). One (4.2%) patient died during follow-up, and one (4.2%) patient underwent a second MV reoperation. The left ventricular end-diastolic diameter was significantly reduced postoperatively compared to preoperatively [ (43.5±8.6) mm vs. (35.8±7.8)mm, P<0.001]. Conclusion The leaflet augmentation technique combined with a standardized repair strategy can achieve satisfactory short- to mid-term outcomes for the redo mitral repair after previous MV repair. It can be considered a safe and feasible technical option for cases with complex valvular lesions and severe pathological changes.
5.Ischemia-reperfusion injury in total knee arthroplasty
Yifeng YANG ; Jian HUANG ; Nan YE ; Lin WANG
Chinese Journal of Tissue Engineering Research 2024;28(6):955-960
BACKGROUND:The mechanism,manifestation,prevention and treatment of ischemia-reperfusion injury have been reported in the past.However,there are few studies on the ischemia-reperfusion injury of lower limb skeletal muscle caused by total knee arthroplasty.This article focuses on the pathogenesis,clinical impact,prevention and treatment of the ischemia-reperfusion injury of lower limb caused by total knee arthroplasty. OBJECTIVE:To summarize the related literature of lower limb ischemia-reperfusion injury caused by total knee arthroplasty,analyze the mechanism and significance,and give hints for further research on skeletal muscle ischemia-reperfusion injury. METHODS:The relevant articles on PubMed,CNKI,WanFang and VIP databases published from January 1,2000 to April 30,2022 were searched by computer with the Chinese and English search terms of"ischemia-reperfusion injury,total knee arthroplasty,tourniquet,mechanism,pathophysiology,skeletal muscle,treatment".After excluding repetitive research and some basic articles with low correlation,68 articles were finally selected for review. RESULTS AND CONCLUSION:(1)The pathogenesis of ischemia-reperfusion injury is related to oxygen free radicals,intracellular calcium overload,neutrophil activation,as well as high concentration of nitric oxide,no reflow phenomenon,apoptosis and other mechanisms.More detailed mechanism research can provide basis for future prevention and treatment.(2)Ischemia-reperfusion injury of lower limbs will cause local skeletal muscle injury,which may be caused by the trauma of the operation itself or the role of ischemia-reperfusion injury.More targeted research is needed to distinguish the relationship between the two.(3)Ischemia-reperfusion injury of lower limbs may even affect the distal organs,causing kidney and lung damage.It also affects local and systemic circulation.(4)To clarify the effect of ischemia-reperfusion injury can point out the direction for future prevention and treatment.The current prevention and treatment measures mainly include ischemic preconditioning,anesthetic,antioxidant and other drug prevention.(5)The detailed review of ischemia-reperfusion injury of lower limb skeletal muscle caused by total knee arthroplasty can provide basis for future diagnosis and treatment decisions.
6.Signaling pathway of dexmedetomidine against ischemia-reperfusion injury
Yifeng YANG ; Nan YE ; Lin WANG ; Shuaicheng GUO ; Jian HUANG
Chinese Journal of Tissue Engineering Research 2024;28(9):1464-1469
BACKGROUND:Dexmedetomidine has the effect of anti-ischemia-reperfusion injury,but the comprehensive and systematic review of its signaling pathway is less. OBJECTIVE:To focus on the review of dexmedetomidine's signaling pathway in the mechanisms of antioxidant stress,inhibition of inflammation,anti-apoptosis,autophagy,and so on. METHODS:The relevant articles on PubMed,CNKI,WanFang,and VIP databases were searched by computer with the key words"ischemia-reperfusion inquiry;dexmedetomidine;signal path;oxidative stress;inflammation;apoptosis"in Chinese and English.After excluding repetitive research and some basic articles with low correlation,57 articles were finally included for review. RESULTS AND CONCLUSION:(1)Dexmedetomidine plays an important role in organ protection through many mechanisms,such as anti-oxidative stress injury,anti-inflammation,anti-apoptosis and autophagy.This involves many pathways,including Nrf2 and its downstream protein antioxidant stress pathway,Toll-like receptor 4 family and nuclear factor-κB-related anti-inflammatory pathway,JAK2/STAT3-related anti-inflammatory pathway,and cholinergic anti-inflammatory pathway,and the cholinergic pathway is the upstream mechanism of many nuclear factor-κB signaling pathways.(2)PI3K/Akt pathway plays different roles according to its activated downstream signals,inhibiting the activation of NLRP3 inflammatory body,activating signal molecules endothelial nitric oxide synthase,mammalian target of rapamycin,and hypoxia-inducible factor 1α to play an anti-inflammatory role,and activate Bad or Bax residues to play an anti-apoptotic role,and PI3K/Akt activates glycogen synthetase kinase-3β.It can also play an anti-inflammatory and anti-apoptotic role.(3)Dexmedetomidine activates SIRT3 to mediate anti-apoptosis and inhibit endoplasmic reticulum stress to produce anti-apoptosis.(4)The detailed review of the anti-ischemia-reperfusion injury signaling pathway of dexmedetomidine can provide a basis for future mechanism research and diagnosis and treatment decisions.
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail