1.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
2.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
3.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
4.Harnessing Machine Learning for Personalized Care of Patients With Idiopathic Sudden Sensorineural Hearing Loss: A Multicenter Cohort Study
Yen-Ting GUO ; Ching-Ting TAN ; Chen-Chi WU ; Chun-Ying WANG ; Chein-Yu HUANG ; Tzu-Hsiang YANG ; Ting-Yi LEE ; Ting-Hua YANG ; Tien-Chen LIU ; Pey-Yu CHEN ; Pei-Hsuan LIN
Clinical and Experimental Otorhinolaryngology 2026;19(2):194-204
Objectives:
. Idiopathic sudden sensorineural hearing loss (ISSNHL) is a significant cause of hearing loss. Intratympanic steroid injection (ITSI) is commonly used as an initial or salvage treatment; however, the lack of a standardized treatment protocol has resulted in variability in clinical practice. In addition, no efficient prediction model currently exists to support personalized management. Therefore, this study aimed to develop tailored management strategies for ISSNHL using a machine-learning model.
Methods:
. This retrospective multicenter cohort study was conducted between January 2015 and December 2020, with data analysis performed between January 2021 and March 2024. Patients were selected based on the International Classification of Diseases, 10th Revision criteria for ISSNHL, along with relevant medication and procedure codes. Patients with pure-tone audiogram results not meeting ISSNHL criteria, better initial hearing in the affected ear, an identifiable etiology, no post-treatment audiogram, or delayed treatment (>6 weeks) were excluded. We included 770 patients diagnosed with ISSNHL who received ITSI. The primary outcome was the area under the receiver operating characteristic curve for prediction performance. Recovery status was determined using the last pure-tone audiogram. Modeling was conducted on the Quanta for Medical Care AI platform using five machine-learning algorithms and a nested cross-validation framework, in which feature selection and hyperparameter tuning were performed in the inner folds and model performance was evaluated in the outer folds.
Results:
. A random forest classifier outperformed the other models in predicting hearing outcomes, achieving an area under the receiver operating characteristic curve of 0.788. Time to ITSI was the most influential treatment-related factor, with ITSI administered within 10 days of hearing loss being associated with better outcomes. This model can be used to provide personalized prognostic estimates under different treatment protocols.
Conclusion
. The machine-learning-based prediction model facilitates personalized treatment strategies and timely treatment adjustments for ISSNHL, thereby optimizing the likelihood of complete recovery.
5.Divergent Small Vessel Disease Burden in Warfarin-Associated and Direct Oral Anticoagulant-Associated Intracerebral Hemorrhage
Sung-Chun TANG ; Ya-Fang CHEN ; Chih-Hao CHEN ; Ching-Hua KUO ; Yuan-Chang CHAO ; Yu-Fong PENG ; Shu-Wen LIN ; Shin-Yi LIN ; Jiann-Shing JENG
Journal of Stroke 2026;28(2):334-338
6.Effects comparison of two peri-examination methods in contrast-enhanced transcranial Doppler screening for patent foramen ovale
Yong-mei XU ; Cui WANG ; Hua-kang LI ; Feng ZHANG ; Lin TAN ; Xue ZHANG ; Chen WAN ; Xiang XU ; Jun HU
Journal of Regional Anatomy and Operative Surgery 2025;34(9):784-788
Objective To explore the effects of different education and examination methods on the examination results during the screening/evaluation of patent foramen ovale by contrast-enhanced transcranial Doppler(cTCD).Methods Patients who underwent cTCD screening/evaluation for patent foramen ovale in our hospital from May 2023 to February 2024 were retrospectively selected as the research subjects.The patients were divided into the observation group and the control group according to different education and examination methods during the peri-examination period.Patients who received video education,modified Valsalva maneuver,and injection of contrast agent with 20 mL syringe were included into the observation group,and patients who received artificial education,Valsalva maneuver,and injection of contrast agent with 10 mL syringe were included into the control group.The positive detection rate of patent foramen ovale,right-to-left shunt microbubble grading during Valsalva/modified Valsalva maneuver,systolic blood flow velocity,pulsatility index(PI),resistive index(RI),examination duration,total physician-patient communication time,whether occlusion surgery was performed,and patient satisfaction were compared between the two groups.Results The positive detection rate of patent foramen ovale by cTCD(82.93%vs.95.92%),the detection rate of the maximum amout(grade Ⅲ)of microbubbles(39.02%vs.61.22%),the total physician-patient communication time during the peri-examination period[11.30(10.00,14.00)minutes vs.8.23(7.00,10.00)minutes],the rate of occlusion surgery(48.78%vs.73.47%),and the total patient satisfaction(80.49%vs.91.84%)showed statistically significant differences between the control group and the observation group(P<0.05).Additionally,the receiver operating characteristic(ROC)curve analysis showed that the area under the curve(AUC)for diagnosing patent foramen ovale were 0.718 in the control group and 0.855 in the observation group.Conclusion Peri-examination interventions such as video education,modified Valsalva maneuver,and injection of contrast agent with 20 mL syringe can improve the positive detection rate of patent foramen ovale,reduce ineffective physician-patient communication,and improve patient satisfaction.
7.Changing antimicrobial resistance profiles of Burkholderia cepacia in hospitals across China:results from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Chunyue GE ; Yunjian HU ; Xiaoman AI ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Hui LI ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2025;25(5):557-562
Objective To examine the changing prevalence and antimicrobial resistance profiles of Burkholderia cepacia in 52 hospitals across China from 2015 to 2021.Methods A total of 9 261 strains of B.cepacia were collected from 52 hospitals between January 1,2015 and December 31,2021.Antimicrobial susceptibility of the strains was tested using Kirby-Bauer method or automated antimicrobial susceptibility testing systems according to a unified protocol.The results were interpreted according to the breakpoints released in the Clinical & Laboratory Standards Institute(CLSI)guidelines(2023 edition).Results A total of 9 261 strains of B.cepacia were isolated from all age groups,especially elderly patients.The proportion was 11.1%(1 032 strains)in children,significantly lower than the proportion in adults.About half(46.5%,4 310/9 261)of the strains were isolated from patients at least 60 years old and 42.3%(3 919/9 261)of the strains were isolated from young adults.Most isolates(71.1%)were isolated from sputum and respiratory secretions,followed by urine(10.7%)and blood samples(8.1%).B.cepacia isolates were highly susceptible to the five antimicrobial agents recommended in the CLSI M100 document(33rd edition,2023).B.cepacia isolates showed relatively higher resistance rates to meropenem and levofloxacin.However,the resistance rates to ceftazidime,trimethoprim-sulfamethoxazole,and minocycline remained below 8.1%.The percentage of B.cepacia strains resistant to levofloxacin was the highest compared to other antibiotics in any of the three age groups(from 12.4%in the patients<18 years old to 20.6%in the patients aged 60 years or older).Conclusions B.cepacia is one of the clinically important non-fermenting gram-negative bacteria.Accurate and timely reporting of antimicrobial susceptibility test results and ongoing antimicrobial resistance surveillance are helpful for rational prescription of antimicrobial agents and proper prevention and control of nosocomial infections.
8.Patient-specific quality assurance for non-normal radiotherapy plans based on statistical process control
Juan DENG ; Gaoyuan LIU ; Chuou YIN ; Jiang LIU ; Guojian MEI ; Ling HUA ; Shutong YU ; Xinhui FU ; Chen LIN ; Tian LI ; Yibao ZHANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):296-301
Objective:To apply statistical process control (SPC) techniques to the quality assurance of non-normal radiotherapy plans through Johnson transformation, establishing patient-specific tolerance and action limits based on treatment sites and dose/distance assessment criteria, thereby enhancing the intensity-modulated radiation therapy (IMRT) verification accuracy and dose delivery precision.Methods:In this study, 951 gamma analysis data of patient-specific quality assurance (PSQA) executed on the Halcyon accelerator platform were selected and categorized into six groups based on treatment sites, including brain (102 cases), head and neck (100 cases), breast (229 cases), lung (154 cases), esophagus (223 cases), and pelvic (143 cases) groups. The six groups of data were statistically analyzed through Anderson-Darling normality tests ( α = 0.05) using Minitab 21 software. Non-normal data were transformed into normal data through Johnson transformation and then were used to establish treatment site-specific tolerance and action limits, which were compared with the Shewhart control charts based on normal distributions. Results:The PSQA result of the six groups all exhibited non-normal distributions ( P < 0.05). Through Johnson transformation, the tolerance and action limits for the head and neck, breast, lung, esophagus, and pelvic areas under the 3%/2 mm criterion ranged from 95.13% to 96.16% and 94.19% to 95.91%, respectively. In contrast, the tolerance and action limits ranged from 91.15% to 94.86% and 89.94% to 94.78% under the 2%/2 mm criterion. Directly applying Shewhart control charts without normality assumptions yielded higher tolerance limits compared to the application of Johnson transformation, increasing the false positive rate in the non-normal PSQA process. Conclusions:Applying the SPC techniques directly to a non-normal process can lead to an increased false alarm rate and wrong process interpretation. The SPC techniques combined with Johnson transformation enable more effective monitoring of a non-normal PSQA process, facilitating timely identification of potential factors that may lead to an out-of-control process based on the treatment site-specific limits.
9.Protective effects and mechanism of sacubitril/valsartan on cardiomyocytes of rabbits with heart failure
Jinlong ZHUANG ; Taoming QIAN ; Genghai LIN ; Hua CHEN ; Fahui RUAN ; Huiping LIN ; Li LIU
Academic Journal of Naval Medical University 2025;46(3):360-373
Objective To study the protective effects and mechanism of sacubitril(Sac)/valsartan(Val)on cardiomyocytes of rabbits with heart failure induced by doxorubicin(DOX).Methods Thirty New Zealand rabbits were selected to establish DOX-induced heart failure rabbit model.Twenty-five rabbits with successful modeling were randomly assigned to model group(DOX group,n=9),DOX+Val group(n=8),and DOX+Sac/Val group(n=8);and another 8 New Zealand rabbits were selected as blank group.The DOX+Val group was gavaged with 4.65 mg/kg Val suspension each time,the DOX+Sac/Val group was gavaged with 9.3 mg/kg Sac/Val suspension each time,and the blank group and DOX group were gavaged with equal volume of distilled water each time.Each group was gavaged twice a day for 8 weeks.After 8 weeks of administration,echocardiography was used to measure left ventricular end-diastolic diameter(LVDD),left ventricular end-systolic diameter(LVSD),left ventricular ejection fraction(LVEF),and left ventricular fractional shortening(LVFS).The heart mass index(HMI)and left ventricular mass index(LVMI)were calculated.The pathological morphology and myocardial fibrosis of myocardial tissue were observed by hematoxylin-eosin(H-E)and Masson staining.The ultrastructure of cardiomyocytes was observed by transmission electron microscope.Terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling(TUNEL)staining was used to observe cardiomyocytes apoptosis and apoptosis rate was calculated.Enzyme-linked immunosorbent assay(ELISA)was used to detect the levels of N-terminal pro-brain natriuretic peptide(NT-proBNP),high-sensitivity cardiac troponin I(Hs-cTNI),angiotensin Ⅱ(Ang Ⅱ),aldosterone(ALD),atrial natriuretic peptide(ANP),brain natriuretic peptide(BNP),cyclic guanosine monophosphate(cGMP),and protein kinase G(PKG)in serum.Quantitative polymerase chain reaction(qPCR)was used to detect the expression of natriuretic peptide receptor A(NPR-A),cGMP-specific phosphodiesterase 5A(PDE5A[cGMP]),PKG,B-cell lymphoma 2(Bcl-2),Bcl-2 associated X protein(Bax),and cysteine aspartate protease 3(caspase 3)mRNA in myocardial tissue.Western blotting was used to detect the expression of phosphorylated cAMP response element-binding protein(p-CREB),phosphorylated Bcl-2 related death promoting factor(p-Bad),Bcl-2,Bax,and caspase 3 proteins in myocardial tissue.Results Compared with the blank group,the LVDD and LVSD in the DOX group were increased(both P<0.01),the LVEF and LVFS were decreased(both P<0.01)and the HMI and LVMI were increased(both P<0.01);the apoptosis and apoptosis rate of cardiomyocytes were increased(P<0.01);the levels of NT-proBNP,Hs-cTNI,Ang Ⅱ,ALD,ANP,BNP,cGMP and PKG and the expression of NPR-A,PDE5A(cGMP),PKG,p-CREB,Bax and caspase 3 were all increased(all P<0.01),while the expression of Bcl-2 was decreased(P<0.01),and the expression of p-Bad had no significant difference(P>0.05).Compared with the DOX group,the LVDD and LVSD of the DOX+Sac/Val group and DOX+Val group were decreased(all P<0.01),the LVEF and LVFS were increased(all P<0.01)and the HMI and the LVMI were decreased(all P<0.01);the apoptosis and apoptosis rate of cardiomyocytes were decreased(all P<0.01);the levels of NT-proBNP,Hs-cTNI,Ang Ⅱ,ALD,ANP,BNP,cGMP and PKG and the expression of NPR-A,PDE5A(cGMP),PKG,Bax and caspase 3 were all decreased(all P<0.01),while the expression of Bcl-2 was increased(P<0.01);and the expression of p-CREB and p-Bad was increased in the DOX+Sac/Val group(both P<0.01),but there was no significant difference in the DOX+Val group(both P>0.05).Compared with the DOX+Val group,the DOX+Sac/Val group showed a decrease in all indicators except for LVEF,LVFS,NPR-A,ANP,BNP,cGMP,PDE5A(cGMP),PKG,p-CREB,p-Bad,and Bcl-2,which were all elevated(all P<0.05).Myocardial pathology and transmission electron microscopy showed that Sac/Val effectively protected cardiomyocytes,reduced cardiomyocytes apoptosis and myocardial fibrosis,and these effects were significantly better than those of Val.Conclusion Sac/Val can effectively reduce cardiomyocytes apoptosis,improve cardiac function and reduce myocardial fibrosis in rabbits with heart failure,and these effects are superior to Val.Its mechanism may be related to activating the NPR-A/cGMP/PKG signaling pathway and inhibiting renin-angiotensin-aldosterone system.
10.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.

Result Analysis
Print
Save
E-mail