1.Postmenopausal osteoporosis:predictive values of muscle mass,grip strength,and appendicular skeletal muscle index
Zhijie YANG ; Rui ZHAO ; Haolin YANG ; Xiaoyun LI ; Yangbo LI ; Jiachun HUANG ; Yanping LIN ; Lei WAN ; Hongxing HUANG
Chinese Journal of Tissue Engineering Research 2026;30(5):1073-1080
BACKGROUND:The prevalence of osteoporosis is high in postmenopausal women,but muscle mass,grip strength,and how these factors affect osteoporosis are understudied,and the exact link between them has not been clarified.OBJECTIVE:To investigate the correlation between muscle mass,grip strength,appendicular skeletal muscle index and bone mineral density in postmenopausal women with osteoporosis and to assess the potential values of these indices in predicting and diagnosing postmenopausal osteoporosis.METHODS:Eighty-three postmenopausal women were collected from the outpatient clinic of the Third Affiliated Hospital of Guangzhou University of Chinese Medicine from February 2023 to January 2024.General data were collected.Bone mineral density was detected.T-value,muscle mass of each part,grip strength were recorded.The body mass index and appendicular skeletal muscle index were calculated.The patients were categorized into non-osteoporosis group(n=17)and postmenopausal osteoporosis group(n=66)according to T value and fracture history,and were statistically analyzed accordingly.RESULTS AND CONCLUSION:(1)The body mass,body mass index,bone mineral density of the overall lumbar spine,muscle mass and appendicular skeletal muscle index were higher in the non-osteoporosis group than the osteoporosis group(P<0.05).(2)Muscle mass was positively correlated with bone mineral density of the overall lumbar spine and individual vertebrae(P<0.05).(3)Multiple stepwise linear regression analysis showed that body mass and grip strength were linearly and positively correlated with muscle mass;body height and muscle mass were linearly and positively correlated with grip strength,and body mass was linearly and negatively correlated with grip strength.Body mass index was linearly and positively correlated with bone mineral density,and age was linearly and negatively correlated with bone mineral density.(4)Analysis by receiver operating characteristic curve showed that:muscle mass(the area under the curve,sensitivity,specificity and critical value of muscle mass were 0.744,76.50%,74.20%and 36.50 kg,respectively,with P=0.002)and appendicular skeletal muscle index(the area under the curve,sensitivity,specificity and critical value of appendicular skeletal muscle index were 0.739,82.40%,62.10%and 5.81 kg/m2,respectively,and P=0.002)had good predictive value for postmenopausal osteoporosis.To conclude,a reduction in muscle mass and appendicular skeletal muscle index can help to predict the risk of postmenopausal osteoporosis,and the possibility of osteoporosis should be taken into account in postmenopausal women when muscle mass is<36.50 kg or appendicular skeletal muscle index is<5.81 kg/m2,in order to prevent the occurrence of postmenopausal osteoporosis.
2.Postmenopausal osteoporosis:predictive values of muscle mass,grip strength,and appendicular skeletal muscle index
Zhijie YANG ; Rui ZHAO ; Haolin YANG ; Xiaoyun LI ; Yangbo LI ; Jiachun HUANG ; Yanping LIN ; Lei WAN ; Hongxing HUANG
Chinese Journal of Tissue Engineering Research 2026;30(5):1073-1080
BACKGROUND:The prevalence of osteoporosis is high in postmenopausal women,but muscle mass,grip strength,and how these factors affect osteoporosis are understudied,and the exact link between them has not been clarified.OBJECTIVE:To investigate the correlation between muscle mass,grip strength,appendicular skeletal muscle index and bone mineral density in postmenopausal women with osteoporosis and to assess the potential values of these indices in predicting and diagnosing postmenopausal osteoporosis.METHODS:Eighty-three postmenopausal women were collected from the outpatient clinic of the Third Affiliated Hospital of Guangzhou University of Chinese Medicine from February 2023 to January 2024.General data were collected.Bone mineral density was detected.T-value,muscle mass of each part,grip strength were recorded.The body mass index and appendicular skeletal muscle index were calculated.The patients were categorized into non-osteoporosis group(n=17)and postmenopausal osteoporosis group(n=66)according to T value and fracture history,and were statistically analyzed accordingly.RESULTS AND CONCLUSION:(1)The body mass,body mass index,bone mineral density of the overall lumbar spine,muscle mass and appendicular skeletal muscle index were higher in the non-osteoporosis group than the osteoporosis group(P<0.05).(2)Muscle mass was positively correlated with bone mineral density of the overall lumbar spine and individual vertebrae(P<0.05).(3)Multiple stepwise linear regression analysis showed that body mass and grip strength were linearly and positively correlated with muscle mass;body height and muscle mass were linearly and positively correlated with grip strength,and body mass was linearly and negatively correlated with grip strength.Body mass index was linearly and positively correlated with bone mineral density,and age was linearly and negatively correlated with bone mineral density.(4)Analysis by receiver operating characteristic curve showed that:muscle mass(the area under the curve,sensitivity,specificity and critical value of muscle mass were 0.744,76.50%,74.20%and 36.50 kg,respectively,with P=0.002)and appendicular skeletal muscle index(the area under the curve,sensitivity,specificity and critical value of appendicular skeletal muscle index were 0.739,82.40%,62.10%and 5.81 kg/m2,respectively,and P=0.002)had good predictive value for postmenopausal osteoporosis.To conclude,a reduction in muscle mass and appendicular skeletal muscle index can help to predict the risk of postmenopausal osteoporosis,and the possibility of osteoporosis should be taken into account in postmenopausal women when muscle mass is<36.50 kg or appendicular skeletal muscle index is<5.81 kg/m2,in order to prevent the occurrence of postmenopausal osteoporosis.
3.Therapeutic Mechanisms of Xiebai San on Lung Heat-induced Cough and Asthma via Modulating Lung-Brain Axis Metabolism Based on Spatial Metabolomics
Yue XU ; Fuzhi MA ; Yeerjiang AYIMAN ; Lin ZHU ; Qingce ZANG ; Zhijie MA
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):41-48
ObjectiveBased on whole-animal mass spectrometry imaging technology, spatial metabolomics was used to characterize in situ the metabolic alteration patterns in the lungs and brain of a rat model of lung heat-induced cough and asthma, as well as after treatment with Xiebai San. MethodsNine Sprague-Dawley (SD) rats were randomly divided into a blank group (physiological saline), a model group (physiological saline), and a Xiebai San group (9 g·kg-1), with three rats in each group. The model group and the Xiebai San group were both induced using lipopolysaccharide-ovalbumin (LPS-OVA) to establish an asthma rat model. After treatment with Xiebai San, the animals were euthanized on day 21 and rapidly frozen in liquid nitrogen to preserve morphology. Whole-animal tissue sections were prepared using a cryomicrotome, and imaging was performed using the Air-flow-assisted Desorption Electrospray Ionization Mass Spectrometry Imaging (AFADESI-MSI) platform. Based on the corresponding optical images, ion data of metabolites from the lung and brain tissues of each group were extracted. Differential metabolites were analyzed using SIMCA and GraphPad Prism 9.0 software. Metabolites were identified using the HMDB (
4.Therapeutic Mechanisms of Xiebai San on Lung Heat-induced Cough and Asthma via Modulating Lung-Brain Axis Metabolism Based on Spatial Metabolomics
Yue XU ; Fuzhi MA ; Yeerjiang AYIMAN ; Lin ZHU ; Qingce ZANG ; Zhijie MA
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):41-48
ObjectiveBased on whole-animal mass spectrometry imaging technology, spatial metabolomics was used to characterize in situ the metabolic alteration patterns in the lungs and brain of a rat model of lung heat-induced cough and asthma, as well as after treatment with Xiebai San. MethodsNine Sprague-Dawley (SD) rats were randomly divided into a blank group (physiological saline), a model group (physiological saline), and a Xiebai San group (9 g·kg-1), with three rats in each group. The model group and the Xiebai San group were both induced using lipopolysaccharide-ovalbumin (LPS-OVA) to establish an asthma rat model. After treatment with Xiebai San, the animals were euthanized on day 21 and rapidly frozen in liquid nitrogen to preserve morphology. Whole-animal tissue sections were prepared using a cryomicrotome, and imaging was performed using the Air-flow-assisted Desorption Electrospray Ionization Mass Spectrometry Imaging (AFADESI-MSI) platform. Based on the corresponding optical images, ion data of metabolites from the lung and brain tissues of each group were extracted. Differential metabolites were analyzed using SIMCA and GraphPad Prism 9.0 software. Metabolites were identified using the HMDB (
5.Cross-cultural adaptation and validation of a simplified Chinese version of the patient experience with treatment and self-management scale
Jierui LIN ; Kai LIN ; Zhijie XU ; Lihong GUO ; Chuan ZOU
Chinese Journal of General Practitioners 2025;24(2):162-168
Objective:This study aims to simplify the Brief Patient Experience with Treatment and Self-Management (Brief PETS) by creating a Chinese version of the Brief PETS and evaluating its reliability and validity in a population of individuals with type 2 diabetes mellitus (T2DM).Methods:Following Mapi guidelines, the simplified Chinese version of the PETS scale was translated and culturally adapted. Simplified Chinese version of PETS and the Chinese version of the Treatment Burden Questionnaire (TBQ) were administered to T2DM patients recruited from community health centers in four regions of China between June and August 2022 by cluster sampling. Validity was assessed using content, construct, criterion-related, and discriminant validity, while reliability was evaluated using internal consistency and split-half reliability.Results:The Chinese short version of the PETS consists of 11 dimensions and 32 items, namely, medical information, medication, medical appointments, health management, medication side effects, diet, exercise, medical expenses, health care system, social roles, and physical and mental exhaustion. A total of 311 questionnaires were initially collected, with 289 valid responses finally analyzed after excluding ineligible surveys. The Cronbach′s α coefficient and the split-half reliability coefficient were 0.914 and 0.818 respectively. The content validity index (CVI) was 0.60-1.00, and S-CVI/Ave=0.84. Criterion validity showed that the total score of the Chinese simplified version of PETS was significantly correlated with the total score of TBQ ( r=0.804, P<0.01); discriminant validity was good ( P<0.01); nine male factors were extracted by exploratory factor analysis, which explained a total of 75.28% of the total variance, and each of the nine factors fitted different themes in the existing conceptual framework of the burden of care for T2DM with good construct validity. Conclusion:The Chinese version of the PETS scale demonstrates good reliability and validity, and can comprehensively explain the treatment burden of T2DM patients in primary healthcare settings in China.
6.Cross-cultural adaptation and validation of a simplified Chinese version of the patient experience with treatment and self-management scale
Jierui LIN ; Kai LIN ; Zhijie XU ; Lihong GUO ; Chuan ZOU
Chinese Journal of General Practitioners 2025;24(2):162-168
Objective:This study aims to simplify the Brief Patient Experience with Treatment and Self-Management (Brief PETS) by creating a Chinese version of the Brief PETS and evaluating its reliability and validity in a population of individuals with type 2 diabetes mellitus (T2DM).Methods:Following Mapi guidelines, the simplified Chinese version of the PETS scale was translated and culturally adapted. Simplified Chinese version of PETS and the Chinese version of the Treatment Burden Questionnaire (TBQ) were administered to T2DM patients recruited from community health centers in four regions of China between June and August 2022 by cluster sampling. Validity was assessed using content, construct, criterion-related, and discriminant validity, while reliability was evaluated using internal consistency and split-half reliability.Results:The Chinese short version of the PETS consists of 11 dimensions and 32 items, namely, medical information, medication, medical appointments, health management, medication side effects, diet, exercise, medical expenses, health care system, social roles, and physical and mental exhaustion. A total of 311 questionnaires were initially collected, with 289 valid responses finally analyzed after excluding ineligible surveys. The Cronbach′s α coefficient and the split-half reliability coefficient were 0.914 and 0.818 respectively. The content validity index (CVI) was 0.60-1.00, and S-CVI/Ave=0.84. Criterion validity showed that the total score of the Chinese simplified version of PETS was significantly correlated with the total score of TBQ ( r=0.804, P<0.01); discriminant validity was good ( P<0.01); nine male factors were extracted by exploratory factor analysis, which explained a total of 75.28% of the total variance, and each of the nine factors fitted different themes in the existing conceptual framework of the burden of care for T2DM with good construct validity. Conclusion:The Chinese version of the PETS scale demonstrates good reliability and validity, and can comprehensively explain the treatment burden of T2DM patients in primary healthcare settings in China.
7.Effect of position angle on gastric insufflation during induction of general anesthesia in pediatric patients undergoing day surgery
Niqiao CHEN ; Xiaoqiang SUN ; Xiaoling NONG ; Zhijie LIANG ; Jiamei LIANG ; Yixing LU ; Shunzhong JING ; Anyuan LIU ; Yunan LIN
Chongqing Medicine 2025;54(10):2246-2251
Objective To investigate the effect of body position angle on gastric insufflation during the induction of general anesthesia in pediatric patients undergoing day surgery.Methods A total of 111 children scheduled for elective tracheal intubation under general anesthesia at the First Affiliated Hospital of Guangxi Medical University from December 2022 to March 2023 were selected as study subjects.Six children were ex-cluded due to unclear sonographic visualization of the gastric antrum,resulting in 105 children ultimately in-cluded in the study.The children were divided into three groups using a random number table method:Group D0(supine position),Group D5(5° head-up position),and Group D10(10° head-up position),with 35 children in each group.The presence of a"comet-tail artifact"on ultrasound was used as the criterion for determining gastric insufflation during anesthesia induction.The gastric antrum cross-sectional area(CSA)of the gastric antrum was measured before mask ventilation after loss of consciousness(T1)and immediately after tracheal intubation following mask ventilation(T2).The incidence of gastric insufflation,changes in CSA and their differences,and vital sign changes at T1 and T2,were compared among the three groups.Results Compared with Group D0,the incidence of gastric insufflation was significantly lower in Groups D5 and D10[25.7%(9/35)vs.20.0%(7/35)vs.54.0%(19/35)],and the difference was statistically significant(P<0.05).Howev-er,there was no significant difference between Group D5 and Group D10(P>0.05).No significant difference was observed in CSA at T1 among the three groups(P>0.05).At T2,a statistically significant difference in CSA was found among the three groups(P<0.05),with Group D10 showing a smaller CSA than Group D0(P<0.05).The difference in CSA changes was statistically significant among the three groups(P<0.05),with Groups D5 and D10 exhibiting smaller changes than Group D0,and Group D10 showing a smaller change than Group D5(P<0.05).No significant differences were observed in mean artery pressure(MAP),heart rate,pulse oxygen saturation(SpO2)and pressure of end-tidal carbon dioxide(PETCO2)at T1 and T2 among the three groups(P>0.05).A total of 6 children(5.7%)required brief adjustments in jaw support due to irregular PETCO2 waveforms or abnormal peak airway pressure.Conclusion In pediatric patients undergoing day sur-gery under general anesthesia,a 5° head-up position during induction significantly reduces the incidence of gas-tric insufflation and minimizes changes in gastric antral CSA,while a 10° head-up position does not provide ad-ditional benefits.
8.Automatic measurement of detection parameters of quality control of MSCT imaging system
Peiyun YE ; Hui XIONG ; Jian CHEN ; Zhifeng HUANG ; Yamei LIN ; Zhijie YANG ; Chujie CHEN ; Miyang YANG ; Chengkun HONG ; Yuhang ZHANG ; Minghui MAO ; Taipeng ZENG ; Liyuan FU
China Medical Equipment 2024;21(12):18-24
Objective:To design an intelligent measurement program of detection parameters of quality control of imaging system of multi-slice spiral computed tomography (MSCT) based on MATLAB software platform,so as to achieve intelligent detection for quality control of MSCT imaging system. Methods:We designed an intelligent measurement program for the detection parameters of quality control of MSCT imaging system (referred to as the intelligent measurement program) bases on the function of graphical user interfaces (GUI) of MATLAB software. A series of algorithms such as image reading,binarization,and circular detection based on the Hough transform were employed to conduct automatic measurement and calculation for CT values (water),noise and uniformity of the parameters of MSCT quality control. The Intraclass Correlation Coefficient (ICC) was adopted to analyze the consistency of the detection results between the manual measurement method and the designed intelligent detection program. Results:The designed intelligent measurement program in this study can automatically assess the detection parameters of quality control of the MSCT imaging system,which included CT values (water),noise and uniformity. There was favorable consistency in the detection results between the manual measurement method and the intelligent measurement program (range of ICC values was from 0.881 to 0.985). Conclusion:The intelligent measurement program of detection parameters of quality control of MSCT imaging system can simplify the process of calculating detection parameters of quality control of MSCT imaging system,and provide a reliable detection tool for quality control of MSCT imaging equipment,which can effectively improve the detection efficiency of quality control.
9.Automatic measurement of detection parameters of quality control of MSCT imaging system
Peiyun YE ; Hui XIONG ; Jian CHEN ; Zhifeng HUANG ; Yamei LIN ; Zhijie YANG ; Chujie CHEN ; Miyang YANG ; Chengkun HONG ; Yuhang ZHANG ; Minghui MAO ; Taipeng ZENG ; Liyuan FU
China Medical Equipment 2024;21(12):18-24
Objective:To design an intelligent measurement program of detection parameters of quality control of imaging system of multi-slice spiral computed tomography (MSCT) based on MATLAB software platform,so as to achieve intelligent detection for quality control of MSCT imaging system. Methods:We designed an intelligent measurement program for the detection parameters of quality control of MSCT imaging system (referred to as the intelligent measurement program) bases on the function of graphical user interfaces (GUI) of MATLAB software. A series of algorithms such as image reading,binarization,and circular detection based on the Hough transform were employed to conduct automatic measurement and calculation for CT values (water),noise and uniformity of the parameters of MSCT quality control. The Intraclass Correlation Coefficient (ICC) was adopted to analyze the consistency of the detection results between the manual measurement method and the designed intelligent detection program. Results:The designed intelligent measurement program in this study can automatically assess the detection parameters of quality control of the MSCT imaging system,which included CT values (water),noise and uniformity. There was favorable consistency in the detection results between the manual measurement method and the intelligent measurement program (range of ICC values was from 0.881 to 0.985). Conclusion:The intelligent measurement program of detection parameters of quality control of MSCT imaging system can simplify the process of calculating detection parameters of quality control of MSCT imaging system,and provide a reliable detection tool for quality control of MSCT imaging equipment,which can effectively improve the detection efficiency of quality control.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail