1.Clinical application of single-balloon and double-balloon enteroscopy in pediatric small bowel diseases: a retrospective study of 576 cases.
Can-Lin LI ; Jie-Yu YOU ; Yan-Hong LUO ; Hong-Juan OU-YANG ; Li LIU ; Wen-Ting ZHANG ; Jia-Qi DUAN ; Na JIANG ; Mei-Zheng ZHAN ; Chen-Xi LIU ; Juan ZHOU ; Ling-Zhi YUAN ; Hong-Mei ZHAO
Chinese Journal of Contemporary Pediatrics 2025;27(7):822-828
OBJECTIVES:
To evaluate the effectiveness of single-balloon and double-balloon enteroscopy in diagnosing pediatric small bowel diseases and assess the diagnostic efficacy of computed tomography enterography (CTE) for small bowel diseases using enteroscopy as the reference standard.
METHODS:
Clinical data from 576 children who underwent enteroscopy at Hunan Children's Hospital between January 2017 and December 2023 were retrospectively collected. The children were categorized based on enteroscopy type into the single-balloon enteroscopy (SBE) group (n=457) and double-balloon enteroscopy (DBE) group (n=119), and the clinical data were compared between the two groups. The sensitivity and specificity of CTE for diagnosing small bowel diseases were evaluated using enteroscopy results as the standard.
RESULTS:
Among the 576 children, small bowel lesions were detected by enteroscopy in 274 children (47.6%).There was no significant difference in lesion detection rates or complication rates between the SBE and DBE groups (P>0.05), but the DBE group had deeper insertion, longer procedure time, and higher complete small bowel examination rate (P<0.05). The complication rate during enteroscopy was 4.3% (25/576), with 18 cases (3.1%) of mild complications and 7 cases (1.2%) of severe complications, which improved with symptomatic treatment, surgical, or endoscopic intervention. Among the 412 children who underwent CTE, the sensitivity and specificity for diagnosing small bowel diseases were 44.4% and 71.3%, respectively.
CONCLUSIONS
SBE and DBE have similar diagnostic efficacy for pediatric small bowel diseases, but DBE is preferred for suspected deep small bowel lesions and comprehensive small bowel examination. Enteroscopy in children demonstrates relatively good overall safety. CTE demonstrates relatively low sensitivity but comparatively high specificity for diagnosing small bowel diseases.
Retrospective Studies
;
Treatment Outcome
;
Double-Balloon Enteroscopy/statistics & numerical data*
;
Single-Balloon Enteroscopy/statistics & numerical data*
;
Humans
;
Male
;
Female
;
Child
;
Operative Time
;
Tomography, X-Ray Computed/statistics & numerical data*
;
Sensitivity and Specificity
;
Intestine, Small/surgery*
;
Intestinal Diseases/surgery*
2.The Significance of miR-122 in Early Screening of Hepatitis B Infection in Blood Donors.
You-Zhi ZHAN ; Wei-Mei JIANG ; Fang CHEN ; Shou LIN ; Hong-Keng LIN
Journal of Experimental Hematology 2025;33(1):224-229
OBJECTIVE:
To study the correlation between miR-122 and early HBV infection and analyze its application value in early infection of voluntary blood donors.
METHODS:
A total of 150 samples from voluntary blood donors in Fujian Blood Center from May 2021 to July 2022 were collected and divided into group N (normal group), group E (ELISA single positive group), and group D (both ELISA and nucleic acid positive group), and the general information of the three groups of blood donors was collected. Total RNA was extracted from the three groups of samples, and the expression level of miR-122 was detected by qRT-PCR. The expression differences of miR-122 among the three groups of samples were statistically analyzed, and the correlation between the expression level of miR-122 in group D and its HBV DNA copy number was analyzed. The miRNA database was used to predict the potential target genes of miRNA and perform bioinformatics analysis.
RESULTS:
There was no statistical difference in gender, education level, and occupation distribution among the three groups, but the age distribution and number of blood donations among different groups were statistically significant. Compared with group N, the relative expression levels of miR-122 in the plasma of group E and group D were significantly downregulated (P < 0.05); the relative expression level of miR-122 in group D was more significantly downregulated than that in group E (P < 0.001). Pearson correlation analysis showed that the expression level of miR-122 in group D was negatively correlated with the HBV-DNA copy number (R 2=-0.804,P < 0.01). Two potential target genes were screened using the miRNA database: ALDOA(aldolase A) and PKM (pyruvate kinase). GO analysis results showed that the potential target genes of miRNA mainly involved in biological processes including cell homeostasis and regulation of transcriptional processes.
CONCLUSION
Downregulation of miR-122 expression is closely related to early HBV infection and replication activity.
Humans
;
MicroRNAs
;
Blood Donors
;
Hepatitis B/diagnosis*
;
Hepatitis B virus
;
DNA, Viral/blood*
;
Male
;
Female
;
Early Diagnosis
;
Adult
3.Ginsenoside Rb1 inhibits cardiomyocyte apoptosis and rescues ischemic myocardium by targeting Caspase-3.
Chenhui ZHONG ; Liyuan KE ; Fen HU ; Zuan LIN ; Shuming YE ; Ziyao ZHENG ; Shengnan HAN ; Zan LIN ; Yuying ZHAN ; Yan HU ; Peiying SHI ; Lei WEN ; Hong YAO
Journal of Pharmaceutical Analysis 2025;15(3):101142-101142
Image 1.
4.Effect of printing orientation on physical and mechanical properties of 3D printing prosthodontic base resin materials
Xinxin ZHAN ; Lulu CAO ; Dong XIANG ; Hao TANG ; Dandan XIA ; Hong LIN
Journal of Peking University(Health Sciences) 2024;56(2):345-351
Objective:To analyze the influence of forming direction on the surface characteristics,elastic modulus,bending strength and fracture toughness of printed parts and the relationship between forming direction and force direction,and to provide scientific basis and guidance for the clinical applica-tion of oral denture base resin materials.Methods:The 3D printing technology was used to print denture base resin samples.The shape and size of the samples referred to the current standard for testing conven-tional denture base materials.The samples used for physical performance testing were cylindrical(with a diameter of 15 mm and a thickness of 1 mm)and printed at different angles along the Z axis(0°,45°,90°).Scanning electron microscope was used to observe the microscopic topography of the different sam-ples.The color stability of different samples was observed by color stabilizer.The surface roughness of the samples was analyzed by using surface roughness tester.The Vickers hardness was measured to ana-lyze the hardness of the samples.The samples used for mechanical performance testing were rectangular(elastic modulus and bending strength:A length of 64 mm,a width of 10 mm,and a height of 3.3 mm;fracture toughness:A length of 39 mm,a width of 8 mm,and a height of 4 mm),divided into two groups:W group and H group.The W group was printed from the bottom up along the Z axis with the length × width as the bottom surface parallel to the X,Y axis plane,while the H group printed from the bottom up along the Z axis with the length × height as the bottom surface parallel to the X,Y axis plane.The forming angles of both groups were equally divided into 0°,45°,and 90°.The elastic modulus,bending strength and fracture toughness of different samples were studied through universal mechanical testing machine.SPSS 22.0 software was used for statistical analysis.Results:The microscopic topogra-phy and roughness of different samples were closely related to the printing direction,with significant differences between the 0°,45°,and 90° specimens.The 0° specimens had the smoothest surface(roughness<1 μm).The surface of the 45 ° specimen was the roughest(roughness>3 μm).The microhardness of the 0° sample was the best[(196.13±0.20)MPa],with a significant difference com-pared with the 90° sample[(186.62±4.81)MPa,P<0.05].The mechanical properties of different samples were also closely related to the printing direction.The elastic modulus,bending strength,and fracture toughness of the 45° samples in the W group were the highest compared with the other groups.The results of elastic modulus showed that in the H group,the 45° specimens had the highest elastic mo-dulus,which was significantly different from the 0° and 90° specimens(P<0.05).The elastic modulus of 0° and 45° specimens in the W group were higher than those in 90° specimens(P<0.05).The bending strength results showed that there was no significant difference between the specimens from dif-ferent angles in the H group.The bending strength of the 90° specimens in the W group was the smallest,and there was a significant difference between 90° and the 0° and 45° specimens(P<0.05);And the bendind strength of the 0° and 45° specimens in the W group was significantly higher than that of the 0° and 45° specimens in the H group(P<0.05).The fracture toughness results showed that the fracture toughness of the H group specimens was lower than 1.9 MPa m1/2,which was specified in the denture base standard.The 45° samples in the W group were the highest,with significant differences compared with the 0° and 90° samples(P<0.05).And the 90° samples of the W group specimens were lower than 1.9 MPa m1/2.And the fracture toughness of the 45° specimen in the W group was significantly higher than that of all the specimens in the H group(P<0.05).Conclusion:The 0° samples had rela-tively better physical properties.The 45° samples had the best mechanical properties.But the fracture toughness of specimens(H group and 90° samples of W group)did not yet meet clinical requirements.That indicated that the characteristics of the 3D printing denture base resin were affected by the printing direction.Only when the performance of the printed samples in all directions met the minimum require-ments of the standard,they could be used in clinical practice.
5.Comparative Study of Two High-sensitivity Cardiac Troponin 0/3-hour Algorithms for the Diagnosis of Non-ST-segment Elevation Myocardial Infarction in the Chinese Population
Yaoyao CAI ; Yahui LIN ; Qing YANG ; Hong ZHAN ; Min LIU ; Shukui WANG ; Caidong LIU ; Guangxun FENG ; Tao ZHANG ; Yanmin YANG ; Jun ZHU ; Zhou ZHOU ; Yan LINAG
Chinese Circulation Journal 2024;39(11):1070-1077
Objectives:To compare the diagnostic efficacy of non-ST-segment elevation myocardial infarction (NSTEMI) and the predictive value for major adverse cardiovascular events (MACE) of the 0/3-hour algorithm for high-sensitivity cardiac troponin (hs-cTn) recommended by the 2015 European Society of Cardiology (ESC) guidelines for the management of non-ST-segment elevation acute coronary syndrome (NSTE-ACS) and the 2021 "Chinese Expert Consensus on Laboratory Testing and Clinical Application of Cardiac Troponin" in suspected acute coronary syndrome (ACS) patients in the Chinese population. Methods:This is a multicenter prospective observational study,including 1527 patients with suspected ACS from three clinical centers from January 2017 to September 2020.Plasma hs-cTnI levels were measured using the ARCHITECT assay at the time of presentation and 3 hours later in patients with suspected ACS (test determination).Clinical judgment (independent clinical judgment by cardiac experts,independent of the test results) was used as the gold standard to compare the sensitivity,specificity,and consistency of the two diagnostic algorithms,and to analyze their predictive value for MACE at 30 days and 180 days.MACE in this study was defined as a composite event of cardiovascular death,myocardial infarction,and unplanned coronary revascularization. Results:According to clinical judgment,there were 400 patients with NSTEMI and 1127 patients without NSTEMI.The 0/3-hour algorithm recommended by the 2021 Chinese Expert Consensus showed higher sensitivity in diagnosing NSTEMI than the 2015 ESC guidelines (91.50%[95% CI:88.32%-94.04%]vs.87.75%[95% CI:84.13%-90.80%]),but slightly lower specificity (93.88%[95% CI:92.32%-95.21%]vs.95.56%[95% CI:94.19%-96.69%]),with both differences being statistically significant (both P<0.001).In the follow-up at 30 days and 180 days,the incidence of MACE in patients diagnosed with NSTEMI by both algorithms was higher than in those without NSTEMI (P<0.001).The incidence of MACE at 30 days and 180 days for the group excluded from the diagnosis of NSTEMI by 2015 ESC guidelines was 0.19% and 1.120%,respectively,and for the NSTEMI group was 2.89% and 3.68%,respectively;for the group excluded from NSTEMI by the 2021 Chinese Expert Consensus,the incidence was 0.096% and 0.770%,respectively,and for the NSTEMI group was 2.91% and 4.36%,respectively.Cox analysis showed that the HR ratio for MACE at 180 days in the NSTEMI group diagnosed by both algorithms was 3.418 and 5.892,respectively,significantly higher than the group excluded from NSTEMI. Conclusions:The 0/3-hour algorithm recommended by the 2021 Chinese Expert Consensus has superior diagnostic sensitivity compared to the 2015 ESC NSTE-ACS guidelines,at the cost of slightly lower specificity.Both algorithms can effectively predict MACE within 180 days,but based on the data from this study,the algorithm recommended by the 2021 Chinese Expert Consensus is more sensitive in predicting the risk of MACE,and patients excluded from the diagnosis of NSTEMI by this method have a lower incidence of MACE,suggesting that its application in clinical practice may be more helpful in terms of long-term safe management of patients.
6.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
7.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
8.Genomic and cellular infection characteristics of a newly isolated Mangshi virus in China
Heng YANG ; Zhan-Hong LI ; Lei XIAO ; Zhuo-Ran LI ; Jia-Rui XIE ; De-Fang LIAO ; Lin GAO ; Hua-Chun LI
Chinese Journal of Zoonoses 2024;40(6):504-511,528
The genomic characteristics and cellular tropism of a Mangshi virus(MSV)isolated in China were investigated,thereby establishing a robust foundation for further research on the evolution and pathogenicity of MSV.The genome sequence of MSV strain V301/YNJH/2019 was obtained by next-generation sequencing,followed by phylogenetic tree construction and rearrangement assessment using software IQtree,RPD4,and Simplot.Viral proliferation was assessed in C6/36(Aedes albop-ictus),Vero(African green monkey kidney),and BHK(baby hamster kidney)cells.An initial epidemiological investigation of MSV in local cattle and goats was conducted using the serum neutralization test.The genome of MSV strain V301/YNJ H/2019 was 20623 bp in length,encompassing 12 segments of double-stranded RNA(Seg-1 to Seg-12).Sequence analysis confirmed genomic rearrangement of the Seg-1 and Seg-11 sequences,ex-hibiting high similarity to MSV isolated from lake sediment in China in 2022,while Seg-2 to Seg-10 and Seg-12 were most closely related to a MSV strain isolated from mosquitoes in China in 2013.The virus efficiently proliferated and induced sig-nificant cytopathic effects(CPE)in both C6/36 and BHK cells,but limited replication and no observable CPE in Vero cells.No detectable neutralizing antibodies against MSV were detected in 20 goat serum samples collected in Mangshi,while 2 of 20 bo-vine serum samples were positive with neutralizing antibody titers of 1:128 and 1:54.Whole genome sequencing revealed re-assortment events of the V301/YNJH/2019 strain,which is capable of infecting C6/36,BHK,and Vero cells.MSV infection was confirmed in cattle in Mangshi.
9.The effects of hypothalamic microglial activation on ventricular arrhythmias in stress cardiomyopathy.
Peng-Qi LIN ; Quan-Wei PEI ; Bin LI ; Jie-Mei YANG ; Li-Na ZOU ; De-Zhan SU ; Jun-Pei ZHANG ; Hong-Peng YIN ; Mbabazi NADINE ; Jun-Jie YANG ; Nevzorova Vera A ; Khan MUSAWIR ABBAS ; Zhao-Lei JIANG ; Jing-Jie LI ; De-Chun YIN
Journal of Geriatric Cardiology 2024;21(12):1119-1132
BACKGROUND:
Stress cardiomyopathy (SCM) currently has a high incidence in older adults, and the theories regarding its causes include "catecholamine myocardial toxicity" and "sympathetic hyperactivation". However, the role of the central nervous system in the pathogenesis of SCM remains unknown. We investigated the role of microglia activation in the paraventricular hypothalamic nucleus (PVN) in the development of SCM.
METHODS:
An SCM model was created using male Sprague-Dawley (SD) rats, immobilized for 6 h every day for a week. Electrocardiogram, cardiac electrophysiology, and echocardiography examinations were performed to verify the changes in cardiac structure and function in rats with SCM. RNA sequencing was used to explore the changes in the hypothalamus during SCM. In addition, brain and heart tissues were collected to detect microglial activation and sympathetic activity.
RESULTS:
The main findings were as follows: (1) immobilization stress successfully induced SCM in SD rats; (2) microglia were significantly activated in the hypothalamus, as evidenced by cytosol thickening, increases in the number of microglial branches, and microglia enriched in the PVN; (3) in SCM, the microglia in the PVN exhibited increased central and peripheral cardiac sympathetic activity and increased the expression of neuroinflammatory factors; and (4) it is possible that inhibiting microglial activation could suppress the sympathetic activity of the central nervous system and heart and increase cardiac electrical stability in SCM rats.
CONCLUSIONS
SCM was induced in SD rats by immobilization stress, acting through the activation of the hypothalamic microglia. The activated microglia were specifically enriched in the PVN, increasing the activity of the central and peripheral sympathetic nervous systems by regulating the expression of neuro-inflammatory factors, mediating dysfunction of the left ventricle, and increasing the susceptibility to ventricular arrhythmias.
10.Acupuncture for lumbar myofascial pain syndrome: systematic review and Meta-analysis.
Ran ZHANG ; Sheng-Yue WEN ; Hong-Sheng ZHAN ; Xun LIN ; Min ZHANG ; Jian PANG ; Yue-Long CAO ; Bo CHEN
Chinese Acupuncture & Moxibustion 2023;43(11):1324-1332
This study systematically reviewed the clinical efficacy of acupuncture for lumbar myofascial pain syndrome. The randomized controlled trials (RCTs) regarding acupuncture for lumbar myofascial pain syndrome were searched in PubMed, Cochrane Library, Web of Science, EMbase, Scopus, China national knowledge infrastructure (CNKI), Wanfang database, VIP database, and China biomedical literature service system (SinoMed) from database inception until August 1st, 2022. The Cochrane's risk of bias assessment tool was used to assess the risk of bias in all included studies, and Review Manager 5.3 software was used for statistical analysis of the extracted data. As a result, 12 RCTs, involving 1 087 patients with lumbar myofascial pain syndrome, were ultimately included. The Meta-analysis results showed that the visual analog scale (VAS) score of pain in the observation group was lower than those in the oral non-steroidal anti-inflammatory medication control [SMD=-1.67, 95%CI (-2.44, -0.90), Z=4.26, P<0.000 1] and other treatment control [low-frequency electrical stimulation, tuina, electromagnetic wave irradiation combined with piroxicam gel, SMD=-1.98, 95%CI (-2.48, -1.48), Z=7.74, P<0.000 01]. The pain rating index (PRI) score in the observation group was lower than those in the lidocaine injection control [MD=-2.17, 95%CI (-3.41, -0.93), Z=3.44, P=0.000 6] and other treatment control [low-frequency electrical stimulation, tuina, MD=-5.75, 95%CI (-9.97, -1.53), Z=2.67, P=0.008]. The present pain intensity (PPI) score in the observation group was lower than that in other treatment control [low-frequency electrical stimulation, tuina, MD=-1.04, 95%CI (-1.55, -0.53), Z=4.01, P<0.000 1]. In conclusion, compared with oral non-steroidal anti-inflammatory medication, low-frequency electrical stimulation, tuina, and electromagnetic wave irradiation combined with piroxicam gel, acupuncture is more effective in reducing pain in patients with lumbar myofascial pain syndrome; acupuncture also exhibites advantage over lidocaine injection in improving PRI score and showed better outcomes over tuina and low-frequency electrical stimulation in improving PRI and PPI scores.
Humans
;
Piroxicam
;
Acupuncture Therapy/methods*
;
Pain
;
Myofascial Pain Syndromes/therapy*
;
Anti-Inflammatory Agents, Non-Steroidal/therapeutic use*
;
Lidocaine

Result Analysis
Print
Save
E-mail