1.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.
2.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.
3.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.
4.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.
5.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.
6.Clinical application of single-balloon and double-balloon enteroscopy in pediatric small bowel diseases: a retrospective study of 576 cases.
Can-Lin LI ; Jie-Yu YOU ; Yan-Hong LUO ; Hong-Juan OU-YANG ; Li LIU ; Wen-Ting ZHANG ; Jia-Qi DUAN ; Na JIANG ; Mei-Zheng ZHAN ; Chen-Xi LIU ; Juan ZHOU ; Ling-Zhi YUAN ; Hong-Mei ZHAO
Chinese Journal of Contemporary Pediatrics 2025;27(7):822-828
OBJECTIVES:
To evaluate the effectiveness of single-balloon and double-balloon enteroscopy in diagnosing pediatric small bowel diseases and assess the diagnostic efficacy of computed tomography enterography (CTE) for small bowel diseases using enteroscopy as the reference standard.
METHODS:
Clinical data from 576 children who underwent enteroscopy at Hunan Children's Hospital between January 2017 and December 2023 were retrospectively collected. The children were categorized based on enteroscopy type into the single-balloon enteroscopy (SBE) group (n=457) and double-balloon enteroscopy (DBE) group (n=119), and the clinical data were compared between the two groups. The sensitivity and specificity of CTE for diagnosing small bowel diseases were evaluated using enteroscopy results as the standard.
RESULTS:
Among the 576 children, small bowel lesions were detected by enteroscopy in 274 children (47.6%).There was no significant difference in lesion detection rates or complication rates between the SBE and DBE groups (P>0.05), but the DBE group had deeper insertion, longer procedure time, and higher complete small bowel examination rate (P<0.05). The complication rate during enteroscopy was 4.3% (25/576), with 18 cases (3.1%) of mild complications and 7 cases (1.2%) of severe complications, which improved with symptomatic treatment, surgical, or endoscopic intervention. Among the 412 children who underwent CTE, the sensitivity and specificity for diagnosing small bowel diseases were 44.4% and 71.3%, respectively.
CONCLUSIONS
SBE and DBE have similar diagnostic efficacy for pediatric small bowel diseases, but DBE is preferred for suspected deep small bowel lesions and comprehensive small bowel examination. Enteroscopy in children demonstrates relatively good overall safety. CTE demonstrates relatively low sensitivity but comparatively high specificity for diagnosing small bowel diseases.
Retrospective Studies
;
Treatment Outcome
;
Double-Balloon Enteroscopy/statistics & numerical data*
;
Single-Balloon Enteroscopy/statistics & numerical data*
;
Humans
;
Male
;
Female
;
Child
;
Operative Time
;
Tomography, X-Ray Computed/statistics & numerical data*
;
Sensitivity and Specificity
;
Intestine, Small/surgery*
;
Intestinal Diseases/surgery*
7.Value of targeted next-generation sequencing in pathogen detection for neonates with respiratory distress syndrome: a prospective randomized controlled trial.
Hai-Hong ZHANG ; Xia OU-YANG ; Xian-Ping LIU ; Shao-Ru HUANG ; Yun-Feng LIN
Chinese Journal of Contemporary Pediatrics 2025;27(10):1191-1198
OBJECTIVES:
To investigate the application value of targeted next-generation sequencing (tNGS) in the etiological diagnosis of moderate to severe respiratory distress syndrome (RDS) in neonates.
METHODS:
A prospective randomized controlled trial was conducted, enrolling 81 term and late-preterm neonates with moderate to severe RDS admitted to Fujian Children's Hospital between December 2023 and December 2024. Patients were randomly assigned to the conventional microbiological test (CMT) group (n=42) or the tNGS group (n=39). For routine pathogen detection, bronchoalveolar lavage fluid was obtained via bronchoscopy, and lower respiratory tract specimens were collected via the endotracheal tube; all specimens underwent culture, and some specimens additionally underwent polymerase chain reaction or antigen testing. In the tNGS group, tNGS was performed in addition to routine pathogen detection on the same specimen types. The detection rate of pathogens, the detection rate of co-infections, and the duration of antibiotic use were compared between the two groups.
RESULTS:
The pathogen detection rate in the tNGS group (18/39, 46%) was significantly higher than that in the CMT group (8/42, 19%) (P=0.009). The co-infection detection rate was 13% (5/39) in the tNGS group, while no co-infections were identified in the CMT group (P=0.024). Regarding treatment, the duration of antibiotic use in the tNGS group was shorter than that in the CMT group [(12±4) days vs (15±5) days, P=0.003].
CONCLUSIONS
tNGS significantly improves the pathogen detection rate in neonates with moderate to severe RDS and offers advantages in the rapid identification of co-infections and reduction of antibiotic treatment duration, suggesting it has clinical utility and potential for wider adoption.
Humans
;
Prospective Studies
;
Infant, Newborn
;
Female
;
Respiratory Distress Syndrome, Newborn/etiology*
;
Male
;
High-Throughput Nucleotide Sequencing/methods*
8.A novel approach to assessing quality issues and component annotation in TCM prescription: Insights from 100 common TCM products.
Huiting OU ; Chunxiang LIU ; Saiyi YE ; Lin YANG ; Qirui BI ; Wenlong WEI ; Hua QU ; Yaling AN ; Jianqing ZHANG ; De-An GUO
Journal of Pharmaceutical Analysis 2025;15(10):101332-101332
The quality of traditional Chinese medicine (TCM) prescriptions (TCMPs) is critical to clinical efficacy; however, evaluating their consistency and identifying sources of variability remain challenging. This study proposes an integrated strategy to assess the quality of 100 widely sold TCMPs. A "one-for-all" chromatographic method was employed to analyze 645 sample batches. This large-scale data collection enabled statistical evaluations, such as hierarchical cluster analysis (HCA) and similarity heatmap, to identify quality inconsistencies. The introduction of a TCM-specific mass spectrometry (MS) database allowed for rapid, automated annotation of chemicals across 100 prescriptions and facilitated the tracing of raw material sources. Results indicate that 19% of prescriptions exhibited chemical inconsistencies, which are associated with high market value, low pricing, and substantial price disparities. The MS database allowed rapid annotation of 761 and 673 compounds in positive and negative modes, respectively, in 100 TCMPs, with 73 prescriptions reported for the first time. The tracing efforts succeeded in identifying >40% of the raw material sources for 51 prescriptions. P93 (Yinianjin (YNJ)) is a case in which the chromatographic profiles from three manufacturers displayed inconsistencies. Analysis using the database traced divergent peaks to Rhei Radix et R hizoma (RRER). Verification with self-prepared samples confirmed that manufacturers utilized three distinct botanical sources. This integrated strategy provides a scalable framework for quality control in TCMPs.
9.Inferring Mycobacterium Tuberculosis Drug Resistance and Transmission using Whole-genome Sequencing in a High TB-burden Setting in China
Feng Yu FAN ; Xin Dong LIU ; Wang Yi CHEN ; Chao Xi OU ; Zhi Qi MAO ; Ting Ting YANG ; Jiang Xi WANG ; Cong Wen HE ; Bing ZHAO ; Jiang Zhen LIU ; Maiweilanjiang ABULIMITI ; Maimaitiaili AIHEMUTI ; Qian GAO ; Lin Yan ZHAO
Biomedical and Environmental Sciences 2024;37(2):157-169
Objective China is among the 30 countries with a high burden of tuberculosis(TB)worldwide,and TB remains a public health concern.Kashgar Prefecture in the southern Xinjiang Autonomous Region is considered as one of the highest TB burden regions in China.However,molecular epidemiological studies of Kashgar are lacking. Methods A population-based retrospective study was conducted using whole-genome sequencing(WGS)to determine the characteristics of drug resistance and the transmission patterns. Results A total of 1,668 isolates collected in 2020 were classified into lineages 2(46.0%),3(27.5%),and 4(26.5%).The drug resistance rates revealed by WGS showed that the top three drugs in terms of the resistance rate were isoniazid(7.4%,124/1,668),streptomycin(6.0%,100/1,668),and rifampicin(3.3%,55/1,668).The rate of rifampicin resistance was 1.8%(23/1,290)in the new cases and 9.4%(32/340)in the previously treated cases.Known resistance mutations were detected more frequently in lineage 2 strains than in lineage 3 or 4 strains,respectively:18.6%vs.8.7 or 9%,P<0.001.The estimated proportion of recent transmissions was 25.9%(432/1,668).Multivariate logistic analyses indicated that sex,age,occupation,lineage,and drug resistance were the risk factors for recent transmission.Despite the low rate of drug resistance,drug-resistant strains had a higher risk of recent transmission than the susceptible strains(adjusted odds ratio,1.414;95%CI,1.023-1.954;P = 0.036).Among all patients with drug-resistant tuberculosis(DR-TB),78.4%(171/218)were attributed to the transmission of DR-TB strains. Conclusion Our results suggest that drug-resistant strains are more transmissible than susceptible strains and that transmission is the major driving force of the current DR-TB epidemic in Kashgar.
10.Analysis on comprehensive noise control effects in an automobile engine manufacturing enterprise
Lin CHEN ; Youmei SHU ; Yang LIAO ; Hai ZHANG ; Kunpeng ZHONG ; Jun LIU ; Fengyi OU ; Zhi WANG
China Occupational Medicine 2024;51(2):168-171
ObjectiveTo analyze the measures and effects of comprehensive noise control in an automobile engine manufacturing enterprise. Methods An automobile engine manufacturing enterprise with noise exposure work-sites was selected as the research subject. The noise hazard status of the enterprise was investigated. The noise hazard exceeded the national standard in work-sites was comprehensively treated. The treatment effect was analyzed. Results A total of 395 work-sites exposed to noise were detected. Among them, 16 work-sites exceeded the national noise standard, with the rate of 4.1%. The work-sites with noise exceeding the national standard were mainly in the machine workshop and the casting workshop, with normalization of equivalent continuous A-weighted sound pressure level to a nominal eight hours working day (LEX,8h) ranging from 86.8 to 89.2 and 85.2 to 90.2 dB(A), respectively. In addition, the classification of occupational noise exposure of the mold protection group in the casting workshop was level Ⅱ, and classification of occupational noise exposure of other work-sites with excessive national standard was grade Ⅰ. After the enterprise implemented noise control measures such as process reform, equipment replacement, sound insulation, noise reduction, sound absorption, and vibration isolation, the LEX,8h of nine positions were lower than those before rectification [(86.7±1.1) vs (83.3±1.3) dB(A), P<0.01]. Conclusion The use of comprehensive control measures can achieve the purpose of reducing noise from the sources, and can be used for reference by relevant enterprises with noise hazards.

Result Analysis
Print
Save
E-mail