1.Study on mechanical stability of maxillary LeFort Ⅰ type osteotomy after fixation with mortise and tenon and absorbable plate
Yankun ZHANG ; Zixuan SHEN ; Ran ZHANG ; Lijia DONG ; Yu TIAN ; Li LU ; Mingliang YANG ; Guangqi YAN
Chinese Journal of Stomatology 2025;60(6):635-643
Objective:To evaluate the mechanical stability of the bone block after LeFort Ⅰ osteotomy with maxillary advancement using absorbable plates fixed with tenon-and-mortise structures.Methods:This study developed three finite element models: one for the maxillary LeFort Ⅰ osteotomy with anterior advancement fixed with absorbable plates (Model 1); another for the maxillary LeFort Ⅰ osteotomy with anterior advancement fixed with absorbable plates assisted by tenon-and-mortise structures (Model 2); and the last one for the maxillary LeFort Ⅰ osteotomy with anterior advancement fixed with titanium plates and screws (Model 3). Simulated occlusal forces were applied on the anterior and posterior teeth in each model. The displacement changes of the nasal-palatine point (NP) and posterior nasal spine point (PNS) in the finite element coordinate system were compared and analyzed. The Mises equivalent stress distributions of the metal and absorbable plates were also examined to assess the mechanical stability of the three finite element models. Clinical data from 45 patients with dentofacial deformities treated from January 2017 to January 2023 at the Stomatology Hospital of China Medical University were collected. The age of the patients was 21±3 years. Among these, 15 patients had absorbable plates for fixation, 15 had absorbable plates assisted by tenon-and-mortise structures, and 15 had titanium plates and screws fixation after maxillary advancement. All patients underwent preoperative (T0), postoperative 3 days (T1), and 6 months (T2) spiral CT scans. The CT data in DICOM format were input into digital software, which was used to calculate the distances from the NP and PNS points to the horizontal plane (HP), right sagittal plane (FZSR), and coronal plane (CP) at T1 and T2. The distances at T1 and T2 were statistically analyzed using the Wilcoxon signed-rank test with SPSS 20.0, and a P value of<0.05 was considered statistically significant.Results:The finite element analysis showed that in the absorbable plate-only fixation group, the maximum displacement of the NP point (mm) under anterior and posterior tooth force conditions were 0.6 and 0.12, respectively, and for the PNS point, the maximum displacements were 0.5 and 0.11. In the tenon-and-mortise-assisted absorbable plate fixation group, the displacement of the NP point was 0.40 and 0.02 mm, and the displacement of the PNS point was 0.5 and 0.015 mm. In the titanium plate-screw fixation group, the NP point displacement was 0.33 and 0.055 mm, and the PNS point displacement was 0.16 and 0.1 mm. The Mises equivalent stress on the absorbable plates with tenon-and-mortise structure was significantly lower than that in the absorbable plate-only fixation group, while the titanium plate experienced the highest Mises equivalent stress. The clinical data analysis showed that in the horizontal direction, the postoperative stability of the three fixation methods was similar. However, in the vertical and anterior-posterior directions, the absorbable plate-only fixation group showed significant differences in the distances of PNS-HP, PNS-CP, and NP-CP between T1 and T2 ( P=0.018, P=0.009, P=0.017), suggesting significant postoperative bone displacement. In contrast, the tenon-and-mortise-assisted absorbable plate fixation group and the titanium plate-screw fixation group showed no significant differences in displacement during surgery and postoperatively(all P>0.05), demonstrating higher stability. Conclusions:The tenon-and-mortise-assisted absorbable plate fixation provides comparable stability to titanium plate fixation in clinical results, and it is more stable than absorbable plate-only fixation. In the mechanical study, when force was applied on the anterior teeth, the stability of the tenon-and-mortise-assisted absorbable plate fixation was slightly less than that of titanium plate fixation, but when posterior teeth were used, its stability exceeded both titanium plate fixation and absorbable plate-only fixation. The tenon-and-mortise-assisted absorbable plate fixation serves as an effective alternative to titanium plate fixation after LeFort Ⅰ osteotomy.
2.Research progress of lemborexant in the treatment of insomnia disor-der
Lijia GUO ; Zixuan DONG ; Huizhen WU
Chinese Journal of Clinical Pharmacology and Therapeutics 2025;30(10):1429-1435
Lemborexant is a new drug for the treatment of insomnia.It is a dual orexin receptor antagonist that competitively binds to two orexin receptors,OX1R and OX2R,inhibits orexin neuro-transmission,and regulates the sleep-wake rhythm.This article comprehensively reviews the discovery of the drug target,basic information,clin-ical studies,safety assessment,and limitation anal-ysis of lemborexant,aiming to provide a compre-hensive understanding of the current research sta-tus and achievements of this drug in clinical prac-tice.
3.Study on mechanical stability of maxillary LeFort Ⅰ type osteotomy after fixation with mortise and tenon and absorbable plate
Yankun ZHANG ; Zixuan SHEN ; Ran ZHANG ; Lijia DONG ; Yu TIAN ; Li LU ; Mingliang YANG ; Guangqi YAN
Chinese Journal of Stomatology 2025;60(6):635-643
Objective:To evaluate the mechanical stability of the bone block after LeFort Ⅰ osteotomy with maxillary advancement using absorbable plates fixed with tenon-and-mortise structures.Methods:This study developed three finite element models: one for the maxillary LeFort Ⅰ osteotomy with anterior advancement fixed with absorbable plates (Model 1); another for the maxillary LeFort Ⅰ osteotomy with anterior advancement fixed with absorbable plates assisted by tenon-and-mortise structures (Model 2); and the last one for the maxillary LeFort Ⅰ osteotomy with anterior advancement fixed with titanium plates and screws (Model 3). Simulated occlusal forces were applied on the anterior and posterior teeth in each model. The displacement changes of the nasal-palatine point (NP) and posterior nasal spine point (PNS) in the finite element coordinate system were compared and analyzed. The Mises equivalent stress distributions of the metal and absorbable plates were also examined to assess the mechanical stability of the three finite element models. Clinical data from 45 patients with dentofacial deformities treated from January 2017 to January 2023 at the Stomatology Hospital of China Medical University were collected. The age of the patients was 21±3 years. Among these, 15 patients had absorbable plates for fixation, 15 had absorbable plates assisted by tenon-and-mortise structures, and 15 had titanium plates and screws fixation after maxillary advancement. All patients underwent preoperative (T0), postoperative 3 days (T1), and 6 months (T2) spiral CT scans. The CT data in DICOM format were input into digital software, which was used to calculate the distances from the NP and PNS points to the horizontal plane (HP), right sagittal plane (FZSR), and coronal plane (CP) at T1 and T2. The distances at T1 and T2 were statistically analyzed using the Wilcoxon signed-rank test with SPSS 20.0, and a P value of<0.05 was considered statistically significant.Results:The finite element analysis showed that in the absorbable plate-only fixation group, the maximum displacement of the NP point (mm) under anterior and posterior tooth force conditions were 0.6 and 0.12, respectively, and for the PNS point, the maximum displacements were 0.5 and 0.11. In the tenon-and-mortise-assisted absorbable plate fixation group, the displacement of the NP point was 0.40 and 0.02 mm, and the displacement of the PNS point was 0.5 and 0.015 mm. In the titanium plate-screw fixation group, the NP point displacement was 0.33 and 0.055 mm, and the PNS point displacement was 0.16 and 0.1 mm. The Mises equivalent stress on the absorbable plates with tenon-and-mortise structure was significantly lower than that in the absorbable plate-only fixation group, while the titanium plate experienced the highest Mises equivalent stress. The clinical data analysis showed that in the horizontal direction, the postoperative stability of the three fixation methods was similar. However, in the vertical and anterior-posterior directions, the absorbable plate-only fixation group showed significant differences in the distances of PNS-HP, PNS-CP, and NP-CP between T1 and T2 ( P=0.018, P=0.009, P=0.017), suggesting significant postoperative bone displacement. In contrast, the tenon-and-mortise-assisted absorbable plate fixation group and the titanium plate-screw fixation group showed no significant differences in displacement during surgery and postoperatively(all P>0.05), demonstrating higher stability. Conclusions:The tenon-and-mortise-assisted absorbable plate fixation provides comparable stability to titanium plate fixation in clinical results, and it is more stable than absorbable plate-only fixation. In the mechanical study, when force was applied on the anterior teeth, the stability of the tenon-and-mortise-assisted absorbable plate fixation was slightly less than that of titanium plate fixation, but when posterior teeth were used, its stability exceeded both titanium plate fixation and absorbable plate-only fixation. The tenon-and-mortise-assisted absorbable plate fixation serves as an effective alternative to titanium plate fixation after LeFort Ⅰ osteotomy.
4.Research progress of lemborexant in the treatment of insomnia disor-der
Lijia GUO ; Zixuan DONG ; Huizhen WU
Chinese Journal of Clinical Pharmacology and Therapeutics 2025;30(10):1429-1435
Lemborexant is a new drug for the treatment of insomnia.It is a dual orexin receptor antagonist that competitively binds to two orexin receptors,OX1R and OX2R,inhibits orexin neuro-transmission,and regulates the sleep-wake rhythm.This article comprehensively reviews the discovery of the drug target,basic information,clin-ical studies,safety assessment,and limitation anal-ysis of lemborexant,aiming to provide a compre-hensive understanding of the current research sta-tus and achievements of this drug in clinical prac-tice.
5.The double J tubeless misguided by zebra guidewire into ileum: a case report
Liangcheng LIU ; Guihua CAO ; Guimin HUANG ; Jianping DU ; Wei LI ; Lijia DONG ; Qiang LI
Chinese Journal of Urology 2021;42(8):635-636
A case of severe complications is presented that replaced the double J tubeless misguided by zebra guidewire into ileum in a patient with ureteral dermostomy, causing a ureteral ileum fistula.The result suggests improper operation of zebra guidewire could have a risk of ureteral perforation when the ureter is distorted, narrow or with inflammatory lesions.Standardized diagnosis and treatment and correct selection of guidewire can reduce the risk of ureteral perforation.
6.Enlightenment on Carrying out Reporting Responsibility of Manufactures in China from Reviewing Medical Device Reporting Practice in US.
Yifei ZHAO ; Fang DONG ; Yan ZHAO ; Lijia ZHENG
Chinese Journal of Medical Instrumentation 2020;44(6):545-548
OBJECTIVE:
By introducing the Medical Device Reporting (MDR) system and related inspection practice of the US, this paper puts forward some suggestions on implementing reporting responsibility of manufactures in China.
METHODS:
The MDR system and the related inspection system in the US were systematically analyzed.
RESULTS:
The US had established a sound system for discovering and reporting MDR, and a mechanism for inspecting the implementing of manufactures, forming an effective post-market surveillance system.
CONCLUSIONS
By learning from the experience of the US, we can carry out the post-market surveillance of medical devices adverse events in China from the aspects of implementing the existing system, strengthening the reporting ability and perfecting the inspection mechanism.
China
;
Equipment and Supplies/standards*
;
Product Surveillance, Postmarketing
8.Observation on therapeutic effects of different energy densities of enteral nutrition preparations on mechanical ventilation patients with acute severe traumatic brain injury
Xiaoyuan SHEN ; Guanhua XU ; Lijia CAO ; Kanda PAN ; Hongliang DONG ; Yunchao WANG
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2018;25(6):616-619
Objective To discuss the clinical effects of different energy densities of enteral nutrition (EN) preparations on mechanical ventilation (MV) patients with acute severe traumatic brain injury (sTBI). Methods Sixty MV patients with acute sTBI admitted to the Department of Critical Care Medicine of Hangzhou Xiaoshan District First People's Hospital from July 2015 to December 2017 were divided into two groups according to different energy densities of nutritional preparations. Thirty patients of the control group were given nasal feeding with standard energy density EN (energy density 3.35 - 4.19 kJ/mL) and 30 patients of the observation group were given nasal feeding with relatively higher energy density (energy density 5.44 - 6.28 kJ/mL). The indexes of nutritional status between the two groups before and after treatment were compared: including prealbumin (PA), albumin (Alb), globulin (Glo), hemoglobin (Hb), 5-day and 1-week heat calorie compliance rates of reaching target calories, MV time and incidence of complications. Results There were no statistically significant differences in nutritional indicators before treatment between the two groups (all P > 0.05). The compliance rates of reaching target calories of the observation group on the 5 and 7 days after treatment were significantly higher than those in the control group [5 days: 66.67% (20/30) vs. 50.00% (15/30), 1 week: 81.33% (25/30) vs. 70.00% (21/30), both P < 0.05], and the MV time was significantly lower than that in the control group (hours: 92.48±12.04 vs. 128.88±16.29, P < 0.05); the levels of PA, Alb, Hb, Glo were significantly higher in the observation group than those in control group on the 21st day after treatment [PA (g/L): 0.28±0.11 vs. 0.15±0.04, Alb (g/L): 36.52±5.79 vs. 29.63±2.74, Hb (g/L): 92.40±9.50 vs. 81.10±8.60, Glo (g/L): 24.42±1.73 vs. 18.19±3.59, all P < 0.05]. Complications: the total incidence of abdominal distension, diarrhea and constipation of the observation group was 36.6% (11/30), while that of the control group was 66.7% (20/30), the difference between the two groups being statistically significant (P < 0.05). Conclusion High energy density enteral nutrition can improve the nutritional status of the organisms of MV patients with acute sTBI, reduce the time of MV and the incidence of complications, thus it is worthy to be widely applied clinically.
9.Clinical value of contrast-enhanced ultrasonography in diagnosing thyroid carcinoma
Lijia ZHONG ; Yanhong HUANG ; Zhiyun SHEN ; Yan MA ; Xueru CHEN ; Hongmei ZHANG ; Fang FANG ; Yan DONG
Chinese Archives of Otolaryngology-Head and Neck Surgery 2017;24(2):63-66
OBJECTIVE To evaluate the clinical value of contrast-enhanced ultrasonography (CEUS) in diagnosing thyroid carcinoma.METHODS The clinical data of 129 patients with thyroid nodules,who were examined by CEUS and were operated in Xinhua Hospital between Jan 2014 and Aug 2015,were analyzed in order to compare the diagnostic results of CEUS to the postoperative pathologic findings,and to summarize its imaging features.RESULTS A total of 132 thyroid nodules in 129 patients were examined by CEUS.Among them,103 nodules were diagnosed as thyroid carcinoma,24 nodules were benign thyroid tumor and 5 nodules were thyroiditis.Compared with pathology results,the diagnostic accuracy,sensitivity and specificity of contrast-enhanced ultrasound is 88.6%,92.2% and of 75.9% respectively.The diagnosis of the CEUS in 31 cases was not consistent with the pathological results,in which 8 cases of thyroid carcinoma were misdiagnosed as benign tumor,3 cases of thyroiditis were misdiagnosed as thyroid carcinoma,and 20 cases of benign tumors were misdiagnosed as thyroid carcinoma.The malignant thyroid nodules mainly were papillary carcinoma,which was characterized by'low enhanced'and'slow in fast out'performance in the contrast-enhanced ultrasound examination.CONCLUSION The contrast-enhanced ultrasound examination in diagnosing thyroid carcinoma has much more specificity and sensitivity,the'low-enhanced'and'slow in fast out'signs of the CEUS were the important features of malignant thyroid nodules.
10. Distribution and drug resistance of pathogens at hematology department of Jiangsu Province from 2014 to 2015: results from a multicenter, retrospective study
Yike WAN ; Wei SANG ; Bing CHEN ; Yonggong YANG ; Luqin ZHANG ; Aining SUN ; Yuejun LIU ; Yang XU ; Yipeng CAI ; Chunbin WANG ; Yunfeng SHEN ; Yangwen JIANG ; Xiaoyan ZHANG ; Wei XU ; Ming HONG ; Tao CHEN ; Ruirong XU ; Feng LI ; Yanli XU ; Yan XUE ; Yilong LU ; Zhengmei HE ; Weimin DONG ; Ze CHEN ; Meihua JI ; Yueyan YANG ; Lijia ZHAI ; Yu ZHAO ; Guangqi WU ; Jiahua DING ; Jian CHENG ; Weibo CAI ; Yumei SUN ; Jian OUYANG
Chinese Journal of Hematology 2017;38(7):602-606
Objective:
To describe the distribution and drug resistance of pathogens at hematology department of Jiangsu Province from 2014 to 2015 to provide reference for empirical anti-infection treatment.
Methods:
Pathogens were from hematology department of 26 tertiary hospitals in Jiangsu Province from 2014 to 2015. Antimicrobial susceptibility testing was carried out according to a unified protocol using Kirby-Bauer method or agar dilution method. Collection of drug susceptibility results and corresponding patient data were analyzed.
Results:
The separated pathogens amounted to 4 306. Gram-negative bacteria accounted for 64.26%, while the proportions of gram-positive bacteria and funguses were 26.99% and 8.75% respectively. Common gram-negative bacteria were Escherichia coli (20.48%) , Klebsiella pneumonia (15.40%) , Pseudomonas aeruginosa (8.50%) , Acinetobacter baumannii (5.04%) and Stenotropho-monas maltophilia (3.41%) respectively. CRE amounted to 123 (6.68%) . Common gram-positive bacteria were Staphylococcus aureus (4.92%) , Staphylococcus hominis (4.88%) and Staphylococcus epidermidis (4.71%) respectively. Candida albicans were the main fungus which accounted for 5.43%. The rates of Escherichia coli and Klebsiella pneumonia resistant to carbapenems were 3.5%-6.1% and 5.0%-6.3% respectively. The rates of Pseudomonas aeruginosa resistant to tobramycin and amikacin were 3.2% and 3.3% respectively. The resistant rates of Acinetobacter baumannii towards tobramycin and cefoperazone/sulbactam were both 19.2%. The rates of Stenotrophomonas maltophilia resistant to minocycline and sulfamethoxazole were 3.5% and 9.3% respectively. The rates of Staphylococcus aureus, Enterococcus faecium and Enterococcus faecalis resistant wards vancomycin were 0, 6.4% and 1.4% respectively; also, the rates of them resistant to linezolid were 1.2%, 0 and 1.6% respectively; in addition, the rates of them resistant to teicoplanin were 2.8%, 14.3% and 8.0% respectively. Furthermore, MRSA accounted for 39.15% (83/212) .
Conclusions
Pathogens were mainly gram-negative bacteria. CRE accounted for 6.68%. The rates of Escherichia coli and Klebsiella pneumonia resistant to carbapenems were lower compared with other antibacterial agents. The rates of gram-positive bacteria resistant to vancomycin, linezolid and teicoplanin were still low. MRSA accounted for 39.15%.

Result Analysis
Print
Save
E-mail