1.Comparison of Acute Hemodynamics,Left Ventricular Fluid and Energy Losses Between Different Pacing Sites of the Cardiac Conduction System in Beagles
Yiran HU ; Han JIN ; Hui LI ; Sijing CHENG ; Sixian WENG ; Hao HUANG ; Juwei YANG ; Yu YU ; Ligang DING ; Min GU ; Hongxia NIU ; Wei HUA
Chinese Circulation Journal 2025;40(1):82-89
Objectives:Comparative analysis of the beagles acute-phase electrocardiographic,hemodynamic,left ventricular flow field status,and energy consumption characteristics of pacing at different sites of conduction system may help to elucidate the scientific mechanism of left bundle branch pacing(LBBP)as a option of physiological pacing therapy.Methods:Eight healthy adult beagles were used in this study.Initially,an active fixation lead was implanted in the right atrial appendage,followed by implantation of another active fixation lead at the right ventricular apex,distal His bundle,and left bundle septal branch,respectively.After connecting a dual-chamber pacemaker,electrocardiographic and acute phase hemodynamic parameters under sinus rhythm,right ventricular apex pacing(RVAP),distal His bundle pacing(DHBP),and LBBP states were collected and analyzed.Three complete cardiac cycles of standard apical three-chamber color Doppler dynamic images were acquired under vector flow mapping(VFM)mode.Offline analysis was performed on obtained parameters including isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,atrial contraction period,and left ventricular intracavitary energy consumption.These parameters were compared under pacing at different sites and the linear correlations of major parameters were analyzed.Results:The QRS duration of baseline intrinsic sinus rhythm,RVAP,DHBP and LBBP were(45.0±4.0)ms,(98.4±6.2)ms,(50.0±4.5)ms and(62.0±4.7)ms,respectively.The LBBP-QRS duration was significantly wider than intrinsic sinus rhythm and DHBP,but significantly narrower than RVAP(all P<0.01).Compared with baseline AOO mode(the pacing rate was performed at 10 beats/min above the intrinsic heart rate),the change of acute phase maximum left ventricular pressure rise rate(LVdP/dtmax)in RVAP,DHBP and LBBP was([-7.89±5.67]% ),([0.74±2.05]% )and([-0.14±3.59]% ),respectively.There was no significant difference in LVdP/dtmax changes between DHBP and LBBP(P=0.667),but both pacing modalities were significantly better than RVAP(all P<0.01).The average energy consumption of the left ventricle under RVAP was significantly higher than that of intrinsic sinus rhythm,DHBP,and LBBP in isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,and atrial contraction period(all P<0.01).However,there was no statistically significant difference in energy consumption among intrinsic sinus rhythm,DHBP,and LBBP during the above five phases(all P>0.05).DHBP and LBBP did not show a significant increase in the number of left ventricular vortices,vortex area,and circulation intensity compared to intrinsic sinus rhythm,and LBBP did not show a significant increase in vortex area and circulation intensity compared to DHBP.Conclusions:Although LBBP canines significantly prolonged the paced QRS duration,it showed no significant differences in acute phase left ventricular hemodynamics,left ventricular flow field status,and energy consumption compared to intrinsic sinus rhythm and DHBP.Performance of LBBP was superior to RVAP.This study may contribute to revealing the theoretical basis of LBBP as a feasible physiological pacing therapy.
2.Safety and Efficacy of Same-day Discharge Following Radiofrequency Catheter Ablation for Arrhythmia:a Pilot Study
Yu XIA ; Qin XU ; Guanzhi CHEN ; Nianqin ZHANG ; Zhicheng HU ; Lingmin WU ; Lihui ZHENG ; Ligang DING ; Yan YAO
Chinese Circulation Journal 2025;40(7):646-652
Objectives:To preliminarily investigate the safety and efficacy of same-day discharge(SDD)following radiofrequency catheter ablation for arrhythmia.Methods:A total of 50 consecutive patients who underwent radiofrequency catheter ablation for arrhythmia in the SDD strategy at Fuwai Hospital from 8 July 2024 to 18 September 2024 were included in this analysis.The study evaluated the immediate success rate of the ablation,the rate of all-cause and arrhythmia-related readmission,outpatient or emergency visits and incidence of complications within 30 days post ablation,and recurrence rate of arrhythmias over a 3-month follow-up period.Results:The average age of the 50 patients was(47.2±16.1)years old,32 patients(64.0%)were male.Radiofrequency catheter ablation was performed in 47 patients(94.0%),including 18(36.0%)atrial fibrillation(AF)ablation.Three patients(6.0%)underwent electrophysiological study only.The immediate success rate for ablation patients was 100%(47/47).None of the patients developed vascular puncture-related or ablation-related complications.The average hospital stay and postoperative observation time were(6.84±1.13)hours and(3.40±1.12)hours,respectively.The all-cause and arrhythmia-related readmission,outpatient or emergency visits rates within 30 days were 12.0%(6/50)and 2.0%(1/50),respectively.Two patients(4.0%)post ablation experienced AF recurrence during the 3-months follow-up period.Conclusions:Radiofrequency catheter ablation for arrhythmias in SDD strategy is safe,effective,and feasible.
3.Safety and Efficacy of Same-day Discharge Following Radiofrequency Catheter Ablation for Arrhythmia:a Pilot Study
Yu XIA ; Qin XU ; Guanzhi CHEN ; Nianqin ZHANG ; Zhicheng HU ; Lingmin WU ; Lihui ZHENG ; Ligang DING ; Yan YAO
Chinese Circulation Journal 2025;40(7):646-652
Objectives:To preliminarily investigate the safety and efficacy of same-day discharge(SDD)following radiofrequency catheter ablation for arrhythmia.Methods:A total of 50 consecutive patients who underwent radiofrequency catheter ablation for arrhythmia in the SDD strategy at Fuwai Hospital from 8 July 2024 to 18 September 2024 were included in this analysis.The study evaluated the immediate success rate of the ablation,the rate of all-cause and arrhythmia-related readmission,outpatient or emergency visits and incidence of complications within 30 days post ablation,and recurrence rate of arrhythmias over a 3-month follow-up period.Results:The average age of the 50 patients was(47.2±16.1)years old,32 patients(64.0%)were male.Radiofrequency catheter ablation was performed in 47 patients(94.0%),including 18(36.0%)atrial fibrillation(AF)ablation.Three patients(6.0%)underwent electrophysiological study only.The immediate success rate for ablation patients was 100%(47/47).None of the patients developed vascular puncture-related or ablation-related complications.The average hospital stay and postoperative observation time were(6.84±1.13)hours and(3.40±1.12)hours,respectively.The all-cause and arrhythmia-related readmission,outpatient or emergency visits rates within 30 days were 12.0%(6/50)and 2.0%(1/50),respectively.Two patients(4.0%)post ablation experienced AF recurrence during the 3-months follow-up period.Conclusions:Radiofrequency catheter ablation for arrhythmias in SDD strategy is safe,effective,and feasible.
4.Comparison of Acute Hemodynamics,Left Ventricular Fluid and Energy Losses Between Different Pacing Sites of the Cardiac Conduction System in Beagles
Yiran HU ; Han JIN ; Hui LI ; Sijing CHENG ; Sixian WENG ; Hao HUANG ; Juwei YANG ; Yu YU ; Ligang DING ; Min GU ; Hongxia NIU ; Wei HUA
Chinese Circulation Journal 2025;40(1):82-89
Objectives:Comparative analysis of the beagles acute-phase electrocardiographic,hemodynamic,left ventricular flow field status,and energy consumption characteristics of pacing at different sites of conduction system may help to elucidate the scientific mechanism of left bundle branch pacing(LBBP)as a option of physiological pacing therapy.Methods:Eight healthy adult beagles were used in this study.Initially,an active fixation lead was implanted in the right atrial appendage,followed by implantation of another active fixation lead at the right ventricular apex,distal His bundle,and left bundle septal branch,respectively.After connecting a dual-chamber pacemaker,electrocardiographic and acute phase hemodynamic parameters under sinus rhythm,right ventricular apex pacing(RVAP),distal His bundle pacing(DHBP),and LBBP states were collected and analyzed.Three complete cardiac cycles of standard apical three-chamber color Doppler dynamic images were acquired under vector flow mapping(VFM)mode.Offline analysis was performed on obtained parameters including isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,atrial contraction period,and left ventricular intracavitary energy consumption.These parameters were compared under pacing at different sites and the linear correlations of major parameters were analyzed.Results:The QRS duration of baseline intrinsic sinus rhythm,RVAP,DHBP and LBBP were(45.0±4.0)ms,(98.4±6.2)ms,(50.0±4.5)ms and(62.0±4.7)ms,respectively.The LBBP-QRS duration was significantly wider than intrinsic sinus rhythm and DHBP,but significantly narrower than RVAP(all P<0.01).Compared with baseline AOO mode(the pacing rate was performed at 10 beats/min above the intrinsic heart rate),the change of acute phase maximum left ventricular pressure rise rate(LVdP/dtmax)in RVAP,DHBP and LBBP was([-7.89±5.67]% ),([0.74±2.05]% )and([-0.14±3.59]% ),respectively.There was no significant difference in LVdP/dtmax changes between DHBP and LBBP(P=0.667),but both pacing modalities were significantly better than RVAP(all P<0.01).The average energy consumption of the left ventricle under RVAP was significantly higher than that of intrinsic sinus rhythm,DHBP,and LBBP in isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,and atrial contraction period(all P<0.01).However,there was no statistically significant difference in energy consumption among intrinsic sinus rhythm,DHBP,and LBBP during the above five phases(all P>0.05).DHBP and LBBP did not show a significant increase in the number of left ventricular vortices,vortex area,and circulation intensity compared to intrinsic sinus rhythm,and LBBP did not show a significant increase in vortex area and circulation intensity compared to DHBP.Conclusions:Although LBBP canines significantly prolonged the paced QRS duration,it showed no significant differences in acute phase left ventricular hemodynamics,left ventricular flow field status,and energy consumption compared to intrinsic sinus rhythm and DHBP.Performance of LBBP was superior to RVAP.This study may contribute to revealing the theoretical basis of LBBP as a feasible physiological pacing therapy.
5.Research Progress on the Application of Left Bundle Branch Area Pacing in Patients With Concomitant Left Bundle Branch Block and Heart Failure
Chinese Circulation Journal 2024;39(2):199-203
Physiological pacing,such as His bundle pacing and left bundle branch area pacing,could significantly enhance cardiac electromechanical synchrony.Compared to His bundle pacing,left bundle branch area pacing is associated with higher implantation success,lower and stable pacing thresholds,and lower complications.The feasibility,safety,and efficacy of left bundle branch area pacing in patients with chronic heart failure and concomitant left bundle branch block have been preliminarily confirmed,making this strategy as a gradually emerging research focus now.This article aimed to summarize relevant study results and advancements of left bundle branch area pacing in patients with combined left bundle branch block and heart failure.
6.Contrast-Enhanced Ultrasound in the Differential Diagnosis of Gallbladder Polypoid Lesions:A Multicenter Study
Ligang JIA ; Xiang FEI ; Xiang JING ; Mingxing LI ; Fang NIE ; Dong JIANG ; Shaoshan TANG ; Wei ZHANG ; Hong DING ; Tao SONG ; Qi ZHOU ; Bei ZHANG ; Zhixia SUN ; Xiaojuan MA ; Nianan HE ; Fang LI ; Yingqiao ZHU ; Wen CHENG ; Yukun LUO
Chinese Journal of Medical Imaging 2024;32(11):1147-1154
Purpose To explore the value of contrast-enhanced ultrasound(CEUS)in the differential diagnosis of gallbladder polypoid lesions(GPLs)(diameter≥10 mm).Materials and Methods A prospective enrollment of 229 patients with GPLs who underwent cholecystectomy in 17 hospitals from December 1 2021 to June 30 2024 was conducted to analyze the relationship between general data,conventional ultrasound,CEUS characteristics and the nature of GPLs.Multivariate Logistic regression was employed to identify independent risk factors for neoplastic polyps,the differential diagnostic value of different indicators was compared.Results Among 229 patients with GPLs,there were 108 cases of cholesterol polyps,102 cases of adenoma and 19 cases of gallbladder cancer.Age(Z=-4.476,P<0.001),polyp number(χ2=15.561,P<0.001),diameter(Z=-8.149,P<0.001),echogenicity(χ2=9.241,P=0.010),vascularity(χ2=23.107,P<0.001),enhancement intensity(χ2=47.610,P<0.001),enhancement pattern(χ2=6.468,P=0.011),vascular type(χ2=84.470,P<0.001),integrity of gallbladder wall(χ2=7.662,P=0.006)and stalk width(Z=-9.831,P<0.001)between cholesterol polyps and neoplastic polyps were statistically significant.Age,location,diameter,echogenicity,enhancement pattern,vascular type and stalk width between adenoma and gallbladder cancer were statistically significant(Z=-4.333,-3.902,-5.042,all P<0.05).Multivariate Logistic regression analysis showed that hyper-enhancement,branched vascular type and stalk width were independent risk factors for neoplastic polyps(OR=4.563,5.770,3.075,all P<0.001).The combination of independent risk factors was better than single factor and diameter in the differential diagnosis of cholesterol polyps and neoplastic polyps(all P<0.01).Conclusion CEUS can effectively identify the nature of GPLs and provide a valuable imaging reference for the selection of treatment methods.
7.Atrial fibrillation: mechanism and clinical management.
Zhicheng HU ; Ligang DING ; Yan YAO
Chinese Medical Journal 2023;136(22):2668-2676
Atrial fibrillation (AF), the most common sustained arrhythmia, is associated with a range of symptoms, including palpitations, cognitive impairment, systemic embolism, and increased mortality. It places a significant burden on healthcare systems worldwide. Despite decades of research, the precise mechanisms underlying AF remain elusive. Current understanding suggests that factors like stretch-induced fibrosis, epicardial adipose tissue (EAT), chronic inflammation, autonomic nervous system (ANS) imbalances, and genetic mutations all play significant roles in its development. In recent years, the advent of wearable devices has revolutionized AF diagnosis, enabling timely detection and monitoring. However, balancing early diagnosis with efficient resource utilization presents new challenges for healthcare providers. AF management primarily focuses on stroke prevention and symptom alleviation. Patients at high risk of thromboembolism require anticoagulation therapy, and emerging pipeline drugs, particularly factor XI inhibitors, hold promise for achieving effective anticoagulation with reduced bleeding risks. The scope of indications for catheter ablation in AF has expanded significantly. Pulsed field ablation, as a novel energy source, shows potential for improving success rates while ensuring safety. This review integrates existing knowledge and ongoing research on AF pathophysiology and clinical management, with emphasis on diagnostic devices, next-generation anticoagulants, drugs targeting underlying mechanisms, and interventional therapies. It offers a comprehensive mosaic of AF, providing insights into its complexities.
Humans
;
Atrial Fibrillation/drug therapy*
;
Stroke
;
Risk Factors
;
Anticoagulants/therapeutic use*
;
Blood Coagulation
;
Catheter Ablation
;
Treatment Outcome
8. Initial experience of catheter ablation of ventricular tachycardia originate from endocardium via direct ventricle puncture access in patients underwent mechanical valve implantation
Lingmin WU ; Jingru BAO ; Lihui ZHENG ; Gang CHEN ; Ligang DING ; Yan YAO
Chinese Journal of Cardiology 2018;46(3):213-217
Objective:
To evaluate the results of catheter ablation of ventricular tachycardia (VT) via direct ventricle puncture access in patients without traditional approach.
Methods:
Two idiopathic left fasicular VT patients with mechanical aortic and mitrial valve repalcement and 1 patient with right ventricular originated VT post mechanical tricuspid valve repalcement from March 2010 to July 2012 in Fuwai hospital were enrolled in this study. For left fasicular VT patients, catheter ablation was performed using transapical left ventricular access via minithoracotomy. For the patient with right ventricular originated VT, catheter ablation was performed via percutaneous right ventricle puncture at xiphoid. Abaltion was guided under EnSite NavX mapping system. The feasibility of VT ablation via direct ventricle puncture access and long-term VT recurrence were investigated.
Results:
Catheter ablation was successful in all patients, and all clinical VTs were eliminated. The procedure time was 53, 62 and 74 minutes respectively with radiation time 11, 16 and 20 minutes. The ablation time was 130, 170 and 240 seconds individually. No procedure related complication occurred. After a follow-up time of 76, 55 and 82 months respectively, no VT recurrence was found in patients with left fasicular VT. New-onset VT with different morphology with previous VT was recorded in the patient with right ventricular originated VT, subcutaneous implantable defibrillator was implanted finally in this patient.
Conclusions
For patients with endocardial origined ventricular arrhythmias which could not be ablated via traditional approaches, direct ventricle puncture access with hybrid techniques provides a new approach foreliminating VTs in these patients.
9.The Derivation and Validation of a Scoring System for Clinical Prognosis in Patients Releiving Cardiac Resynchronization Therapy
Shengwen YANG ; Zhimin LIU ; Shangyu LIU ; Ligang DING ; Keping CHEN ; Wei HUA ; Shu ZHANG
Chinese Circulation Journal 2017;32(8):761-765
Objective: To create and validate a scoring system for predicting clinical prognosis in patients with cardiac resynchronization therapy (CRT). Methods: A cohort of 367 consecutive patients received CRT in our hospital from 2010-01 to 2015-12 were enrolled. The endpoint follow-up events were all-cause death including heart transplantation and heart failure re-admission. The patients were randomly categorized into 2 groups: Modeling group, to develop HEAL scoring system,n=300 and Veriifcation group, to validate HEAL model,n=67. HEAL system was established by Cox proportional hazards regression model, discrimination between HEAL and EARRN scoring systems was evaluated by AUC of ROC, HEAL calibration was assessed by Hosmer-Lemeshow test and clinical endpoint evaluation by 2 scoring systems were compared by Kaplan-Meier method. Results: Modeling group analysis indicated that hs-CRP (HR=1.137, 95% CI 1.072-1.205,P<0.001), big endothelin-1 (HR=1.934, 95% CI 1.066-3.507,P=0.03), left atrial diameter (HR=1.045, 95% CI 1.007-1.084,P=0.02) and NYHA IV (HR=2.583, 95% CI 1.331-5.013,P=0.005) were the independent risk factors of adverse prognosis in CRT patients. Based on β partial regression coefifcient, HEAL scoring system was established to classify the patient's risk levels: low risk<4, moderate risk 4-10 and high risk>10. AUC for risk classification in Modeling group and Verification group were 0.719(95% CI 0.629-0.809) and 0.708 (95% CI 0.539-0.878), HEAL can well distinguish clinical prognosis in patients at different risk levels (log-rank test showed in Modeling groupP<0.001 and in Veriifcation groupP=0.002); Hosmer-Lemeshow test presented good calibration,P=0.952. All 367 patients were respectively evaluated by HEAL and EARRN scoring systems, HEAL had the better discrimination than EARRN as AUC 0.763 (95% CI 0.692-0.833) vs AUC 0.602 (95% CI 0.517-0.687). Conclusion: HEAL scoring system can effectively predict adverse prognosis in CRT patients, it had the better discrimination than EARRN system and was valuable to distinguish high risk patients in clinical practice.
10.Impact of left ventricular endocardial pacing on cardiac electrophysiology of canine asynchrony ischemic heart failure
Rui DU ; Ligang DING ; Chuanyan ZHENG ; Yuzhu LIU
Chongqing Medicine 2017;46(25):3460-3462
Objective To study the cardiac electrophysiology changes of canine asynchrony ischemic heart failure under left ventricular endocardial pacing.Methods Left bundle branch radiofrequency catheter ablation and left anterior descending coronary artery ligation were used to establish the model of ischemic heart failure in 18 healthy dogs.Eighteen healthy dogs were randomly divided into two groups,9 cases in each group.The experimental group was treated with cardiac resynchronization therapy(CRT) in left ventricular endocardium,and the control group underwent the sham operation.ECG and echocardiography were done at 6 weeks after operation.Results The left ventricular ejection fraction in the experimental group was significantly higher than that in the control group(38.32 ± 6.08 vs.30.62 ±8.96).The asynchronization index in the experimental group was significantly lower than that in the control group(35.99 ±5.25 vs.78.21 ± 7.02),and the difference was statistically significant(P<0.05).QRS(60.58 ± 7.43 vs.68.33 ± 8.01) and QTc(347.09 ± 17.33 vs.367.81 ± 22.02)in the experimental group were significantly shorter than those in the control group(P<0.05);moreover Tp-e(37.03±9.07 vs.45.76±7.11) and ARI(162.33±22.06 vs.187.21±23.87) in the experimental group were significantly lower than those in the control group(P<0.05).Conclusion Left ventricular endocardial pacing can produce preferably electrophysiological effects and achieve the goal of effective cardiac resynchronization therapy.

Result Analysis
Print
Save
E-mail