1.Value of ultra-high-resolution photon-counting detector CT in improving neurovascular image quality
Guang YAO ; Jun LI ; Junli REN ; Xing LIU ; Lichen REN ; Yiran WANG ; Xiaolei ZHANG ; Jiawei LIU ; Jianbo GAO ; Yonggao ZHANG
Chinese Journal of Radiology 2025;59(12):1353-1360
Methods:This study was a cross-sectional study. A prospective cohort study enrolled 42 patients with clinically suspected acute cerebrovascular disease and those undergoing follow-up examinations after intracranial vascular stenting at the First Affiliated Hospital of Zhengzhou University from June 2024 to May 2025. All patients underwent UHR PCD-CT examinations of the head and neck. Reconstructions were performed based on raw data, yielding conventional standard resolution (SR group) reconstructions and UHR images reconstructed using four distinct convolution kernels (Hv40, Hv48, Hv56, Hv64) in separate groups (Hv40 UHR group, Hv48 UHR group, Hv56 UHR group, Hv64 UHR group). Regions of interest were selected in the anterior cerebral artery, middle cerebral artery, posterior cerebral artery, posterior communicating artery, and anterior communicating artery. CT values and standard deviation (SD) values were measured for each artery, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Additionally, the sharpness of the vessel edges and the full-width-half-maximum (FWHM) of each artery were measured. One-way analysis of variance or the nonparametric Kruskal-Wallis test was used to compare the subjective and objective image quality metrics across the five groups. Pairwise comparisons were performed using the LSD test or Dunn method.Results:Statistically significant differences were observed in the overall comparison of vascular imaging SD, SNR, CNR, vascular edge sharpness, and FWHM among the SR group, Hv40 UHR group, Hv48 UHR group, Hv56 UHR group, and Hv64 UHR group ( P<0.05). No statistically significant differences in CT values were found ( P>0.05). Pairwise comparisons revealed statistically significant differences between all groups ( P<0.05), except that no significant differences were observed in image SD, SNR, CNR, vascular edge sharpness, or FWHM between the Hv56 UHR and Hv64 UHR groups ( P>0.05). Conclusions:UHR PCD-CT provides better image quality for neurovascular imaging. For the display of small intracranial vessels, the Hv64 provides sharper vessel walls and better subjective image quality compared to the less sharp convolutional cores.Objective:To explore the value of ultra-high resolution (UHR) photon-counting detector CT (PCD-CT) to improve the quality of neurovascular images.
2.Value of ultra-high-resolution photon-counting detector CT in improving neurovascular image quality
Guang YAO ; Jun LI ; Junli REN ; Xing LIU ; Lichen REN ; Yiran WANG ; Xiaolei ZHANG ; Jiawei LIU ; Jianbo GAO ; Yonggao ZHANG
Chinese Journal of Radiology 2025;59(12):1353-1360
Methods:This study was a cross-sectional study. A prospective cohort study enrolled 42 patients with clinically suspected acute cerebrovascular disease and those undergoing follow-up examinations after intracranial vascular stenting at the First Affiliated Hospital of Zhengzhou University from June 2024 to May 2025. All patients underwent UHR PCD-CT examinations of the head and neck. Reconstructions were performed based on raw data, yielding conventional standard resolution (SR group) reconstructions and UHR images reconstructed using four distinct convolution kernels (Hv40, Hv48, Hv56, Hv64) in separate groups (Hv40 UHR group, Hv48 UHR group, Hv56 UHR group, Hv64 UHR group). Regions of interest were selected in the anterior cerebral artery, middle cerebral artery, posterior cerebral artery, posterior communicating artery, and anterior communicating artery. CT values and standard deviation (SD) values were measured for each artery, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Additionally, the sharpness of the vessel edges and the full-width-half-maximum (FWHM) of each artery were measured. One-way analysis of variance or the nonparametric Kruskal-Wallis test was used to compare the subjective and objective image quality metrics across the five groups. Pairwise comparisons were performed using the LSD test or Dunn method.Results:Statistically significant differences were observed in the overall comparison of vascular imaging SD, SNR, CNR, vascular edge sharpness, and FWHM among the SR group, Hv40 UHR group, Hv48 UHR group, Hv56 UHR group, and Hv64 UHR group ( P<0.05). No statistically significant differences in CT values were found ( P>0.05). Pairwise comparisons revealed statistically significant differences between all groups ( P<0.05), except that no significant differences were observed in image SD, SNR, CNR, vascular edge sharpness, or FWHM between the Hv56 UHR and Hv64 UHR groups ( P>0.05). Conclusions:UHR PCD-CT provides better image quality for neurovascular imaging. For the display of small intracranial vessels, the Hv64 provides sharper vessel walls and better subjective image quality compared to the less sharp convolutional cores.Objective:To explore the value of ultra-high resolution (UHR) photon-counting detector CT (PCD-CT) to improve the quality of neurovascular images.
3.Value of CCTA in discrimination of subtotal and chronic total occlusion of coronary artery in elderly patients
Junli REN ; Lichen REN ; Guang YAO ; Yonggao ZHANG
Chinese Journal of Geriatric Heart Brain and Vessel Diseases 2024;26(1):9-12
Objective To investigate the value of coronary computed tomography angiography(CCTA)for the non-invasive discrimination of chronic total occlusion(CTO)and subtotal occlu-sion(SO).Methods A total of 134 elderly patients undergoing CCTA and invasive coronary angio-graphy in our hospital from January 2019 to December 2021 were enrolled,and assigned into CTO group(62 cases)and SO(72 cases)according to the results of the examinations.Occlusion length,shape of proximal stump(blunt/conical),and collateral vessels were measured as anatomical find-ings.Transluminal attenuation gradient was obtained by a post-processing software.Univariate and multivariate logistic regression analyses were performed to explore factors related to CTO.Re-stricted cubic splines with three knots at the 10th,50th,and 90th percentiles were used to flexibly model the association of the factors with CTO,and ROC curve was plotted to evaluate the per-formance.Results Diabetes(OR=0.423,95%CI:0.186-0.963),occlusion length(OR=1.088,95%CI:1.031-1.148)and blunt-shaped stump(OR=2.453,95%CI:1.042-5.773)were inde-pendent predictors for discriminating CTO and SO(P<0.05,P<0.01).ROC curve analysis showed that the AUC value of occlusion length in the discrimination was 0.718(95%CI:0.634-0.792,P=0.001).Conclusion CCTA can be used to discriminate CTO and SO in elderly patients.
4.Artemisinins inhibit oral candidiasis caused by Candida albicans through the repression on its hyphal development.
Xiaoyue LIANG ; Ding CHEN ; Jiannan WANG ; Binyou LIAO ; Jiawei SHEN ; Xingchen YE ; Zheng WANG ; Chengguang ZHU ; Lichen GOU ; Xinxuan ZHOU ; Lei CHENG ; Biao REN ; Xuedong ZHOU
International Journal of Oral Science 2023;15(1):40-40
Candida albicans is the most abundant fungal species in oral cavity. As a smart opportunistic pathogen, it increases the virulence by switching its forms from yeasts to hyphae and becomes the major pathogenic agent for oral candidiasis. However, the overuse of current clinical antifungals and lack of new types of drugs highlight the challenges in the antifungal treatments because of the drug resistance and side effects. Anti-virulence strategy is proved as a practical way to develop new types of anti-infective drugs. Here, seven artemisinins, including artemisinin, dihydroartemisinin, artemisinic acid, dihydroartemisinic acid, artesunate, artemether and arteether, were employed to target at the hyphal development, the most important virulence factor of C. albicans. Artemisinins failed to affect the growth, but significantly inhibited the hyphal development of C. albicans, including the clinical azole resistant isolates, and reduced their damage to oral epithelial cells, while arteether showed the strongest activities. The transcriptome suggested that arteether could affect the energy metabolism of C. albicans. Seven artemisinins were then proved to significantly inhibit the productions of ATP and cAMP, while reduced the hyphal inhibition on RAS1 overexpression strain indicating that artemisinins regulated the Ras1-cAMP-Efg1 pathway to inhibit the hyphal development. Importantly, arteether significantly inhibited the fungal burden and infections with no systemic toxicity in the murine oropharyngeal candidiasis models in vivo caused by both fluconazole sensitive and resistant strains. Our results for the first time indicated that artemisinins can be potential antifungal compounds against C. albicans infections by targeting at its hyphal development.
Animals
;
Mice
;
Candida albicans
;
Candidiasis, Oral/drug therapy*
;
Antifungal Agents/pharmacology*
;
Hyphae
;
Artemisinins/pharmacology*
5.Taxonomic Study of the Lichen Genus Lobaria in South Korea.
Mei Rong REN ; Xin Yu WANG ; Young Jin KOH ; Jae Seoun HUR
Mycobiology 2012;40(1):1-7
Lobaria (Schreb.) Hoffm is a common foliose lichen genus found on the Korean Peninsula, yet until now, no revision study has been done on this genus. After careful examination of specimens deposited in the Korean Lichen Research Institute (KoLRI), nine distinct species of Lobaria were confirmed. Morphological characteristics such as the presence or absence of isidia, or whether or not the surface was ridged or smooth, and chemical characteristics such as the result of the medulla reaction were of significant importance in the differentiation of species. Here, we provided detailed descriptions together with a key to all the known Korean species.
Academies and Institutes
;
Lichens
;
Republic of Korea

Result Analysis
Print
Save
E-mail