1.Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing’s Syndrome
Danni MU ; Jiadan FANG ; Songlin YU ; Yichen MA ; Jin CHENG ; Yingying HU ; Ailing SONG ; Fang ZHAO ; Qi ZHANG ; Zhihong QI ; Kui ZHANG ; Liangyu XIA ; Ling QIU ; Huijuan ZHU ; Xinqi CHENG
Annals of Laboratory Medicine 2024;44(1):29-37
Background:
Twenty-four-hour urinary free cortisol (UFC) measurement is the initial diagnostic test for Cushing’s syndrome (CS). We compared UFC determination by both direct and extraction immunoassays using Abbott Architect, Siemens Atellica Solution, and Beckman DxI800 with liquid chromatography-tandem mass spectrometry (LC-MS/MS). In addition, we evaluated the value of 24-hr UFC measured by six methods for diagnosing CS.
Methods:
Residual 24-hr urine samples of 94 CS and 246 non-CS patients were collected.A laboratory-developed LC-MS/MS method was used as reference. UFC was measured by direct assays (D) using Abbott, Siemens, and Beckman platforms and by extraction assays (E) using Siemens and Beckman platforms. Method was compared using Passing–Bablok regression and Bland–Altman plot analyses. Cut-off values for the six assays and corresponding sensitivities and specificities were calculated by ROC analysis.
Results:
Abbott-D, Beckman-E, Siemens-E, and Siemens-D showed strong correlations with LC-MS/MS (Spearman coefficient r = 0.965, 0.922, 0.922, and 0.897, respectively), while Beckman-D showed weaker correlation (r = 0.755). All immunoassays showed proportionally positive bias. The areas under the curve were 0.975 for Abbott-D, 0.972 for LCMS/MS, 0.966 for Siemens-E, 0.948 for Siemens-D, 0.955 for Beckman-E, and 0.877 for Beckman-D. The cut-off values varied significantly (154.8–1,321.5 nmol/24 hrs). Assay sensitivity and specificity ranged from 76.1% to 93.2% and from 93.0% to 97.1%, respectively.
Conclusions
Commercially available immunoassays for measuring UFC show different levels of analytical consistency compared to LC-MS/MS. Abbott-D, Siemens-E, and Beckman-E have high diagnostic accuracy for CS.
2.Exploration on the mechanism of acupuncture and moxibustion combined with sand therapy on bone biomechanics and immune function of knee osteoarthritis rabbits based on G protein coupled signaling pathway
Mingjun XU ; Liangyu QIU ; Chan WANG ; Cheng CHEN ; Xueping ZHU
International Journal of Traditional Chinese Medicine 2024;46(6):737-742
Objective:To explore the mechanism of acupuncture combined with sand therapy on bone biomechanics and immune function in rabbits with knee osteoarthritis based on G protein coupled signal.Methods:Totally 35 rabbits were randomly divided into normal group, model group, sand therapy group, acupuncture and moxibustion group and combined group, with 7 rabbits in each group. Except for the normal group, all other groups were prepared with knee osteoarthritis models. After 12 h modeling, rabbits in the sand therapy group and the combined group were treated with sand therapy. Rabbits in the acupuncture and moxibustion group and the combined group received acupuncture stimulation intervention therapy. Rabbits in normal group and model group only moved freely. The levels of IgG, IgM and IgA in serum and IL-1β and TNF-α were detected by ELISA method. The biomechanical properties of femur were measured by American Instron universal material experimental machine. The pathological changes of rabbits in each group were observed by HE staining. Protein expression levels of Gαs, cAMP and Gi in rabbit cartilage tissues were detected by Western blot.Results:Compared with model group, the levels of IgG, IgM and IgA increased ( P<0.05)l the levels of IL-1β and TNF-α decreased ( P<0.05); the maximum load, breaking load, structural stiffness and capacity absorption of rabbits in sand therapy group, acupuncture group and combined group increased ( P<0.05); the expressions of Gαs and cAMP protein increased ( P<0.05), while the expression of Gi protein decreased ( P<0.05). Conclusion:Acupuncture combined with sand therapy in the treatment of knee osteoarthritis can effectively improve the bone strength of osteoarthritis, reduce the inflammatory response, balance the expression of G protein and improve the imbalance of immunoglobulin.
3.Effects of Compound Dahuang Powder combined with acupuncture on synovial ultrastructure, pathological angiogenesis and Ras/Raf signal of synovial cells in rats with rheumatoid arthritis
Mingjun XU ; Liangyu QIU ; Chan WANG ; Cheng CHEN ; Xueping ZHU
International Journal of Traditional Chinese Medicine 2024;46(8):999-1005
Objective:To investigate the effects of external application of Compound Dahuang Powder combined with acupuncture on the synovial ultrastructure, pathological angiogenesis, and Ras/Raf signaling pathway in rheumatoid arthritis rats.Methods:Totally 100 SPF grade SD rats were selected and divided into normal group, model group, acupuncture group, external application group, and combination group according to random number table method, with 20 rats in each group. Except for the normal group, Freund's complete adjuvant was injected into the bilateral plantars to establish a rheumatoid arthritis model. One week after modeling, the acupuncture group received acupuncture at "Yinlingquan (SP9)" and "Sanyinjiao (SP6)" for 30 minutes, with continuous intervention for 6 days and 7 days as one course of treatment, for a total of 3 courses of intervention. The external application group of rats applied compound Dahuang Powder on the right hind foot and ankle joint, 10 g/time, twice a day, for 7 days as one course of treatment, with a total of 3 intervention courses; the combination group received a combined intervention of acupuncture and external application of compound Dahuang Powder. No intervention was performed in the normal group and model group. The levels of TNF-α and IL-1β in serum of rats in each group were detected using enzyme-linked immunosorbent assay. Transmission electron microscopy was used to observe the ultrastructure of synovial cells. HE staining was used to observe the morphology of synovial tissue. Immunohistochemistry was used to detect vascular endothelial growth factor (VEGF) and its receptor VEGFR2 in synovial tissue. Western blot and RT qPCR were used to detect Ras/Raf protein and mRNA in synovial tissue, respectively.Results:Compared with model group, the levels of TNF-α and IL-1β in serum of rats in acupuncture group and external application group decreased ( P<0.05), the expressions of VEGF and VEGFR2 decreased ( P<0.05), and the expressions of Ras and Raf protein and mRNA in acupuncture group and external application group decreased ( P<0.05). Compared with acupuncture group and external application group, the levels of TNF-α and IL-1β in serum of rats in the combination group decreased ( P<0.05), the expressions of VEGF and VEGFR2 decreased ( P<0.05), and the expressions of Ras and Raf protein and mRNA in the combination group decreased ( P<0.05). The results of synovial cell ultrastructure showed that the nuclear membrane of synovial cells in normal group was good, and the nuclear membrane in model group was seriously damaged. The acupuncture group and external application group had different degrees of improvement, and the combination group had the most significant improvement. HE staining results showed that the joint synovial tissue of the normal group was normal, the joint synovial tissue of the model group had a large amount of inflammatory infiltration, the joint synovial injury of the acupuncture group and the external application group was slightly improved, and the pathological injury of the combined group was significantly reduced. Conclusion:The combination of external application of compound Dahuang Powder and acupuncture can regulate angiogenesis related factors, regulate the Ras/Raf signaling pathway, and improve the ultrastructure of synovial cells in rheumatoid arthritis model rats.
4.Evaluation and application of automated quality control of automatic pipeline in clinical biochemical and immunological detection
Li′an HOU ; Xuesong SHANG ; Chaochao MA ; Liangyu XIA ; Li LIU ; Ying ZHANG ; Yujun SU ; Xin LIU ; Ling QIU
Chinese Journal of Laboratory Medicine 2024;47(1):86-93
Objective:To assess the applicability of fully automatic pipeline automated testing for internal quality control (automated quality control).Methods:Stability, assay efficiency and implementation costs of 18 biochemical tests, 5 immunoturbidimetric tests and 11 chemical illuminescent tests in the Department of Laboratory Medicine of Peking Union Hospital from January 2019 to July 2022 were evaluated using automated quality control implementation methods. The detailed method is as follows: quality control materials for biochemical, immunoturbidimetric and chemiluminescent tests were stored in the refrigerator in the pipeline which was controlled by the intermediate software, and were automatically retrieved and tested as pre-set followed by documenting and storing. The quality control setup for the biochemical tests included refreshing quality control materials daily and weekly,both of which were paralleled for 3 months. The on-line storage stability of quality control materials in the pipeline was evaluated by comparing the coefficients of variation ( CV) of the quality control results between the two patterns. Effect of automated quality control application was evaluated using 6 indicators, including the results′ variation of automatically performed and manually performed quality controls, the out-of-controlled rate, the consumption of quality control materials, the change of staff workload, the impact on the testing time of the first sample, and the failure rate of automated quality control. Results:(1) Storage stability of quality control materials in the pipeline: under the pattern of weekly refresh of the biochemical quality control materials, except for total carbon dioxide (TCO 2) (the CVs of low and high level quality control were respectively 20.24% and 21.82%) and sodium (the CV of low level quality control was 1.51%) that were greater than the allowable variation set by the laboratory, the CVs of the rest tests meet the lab requirements on the allowable variations. (2) The results′ variation of quality control in automatically performed and manually performed control patterns: in the patterns of daily refresh of biochemical quality control materials and weekly refresh of immunoturbidimetric and chemiluminescent quality control materials, the CVs of both low and high levels of quality control were lower in the automatically performed control pattern than that in manually performed pattern for 8 chemiluminescent items of dehydroepiandrosterone sulfate, estradiol, follicle stimulating hormone, luteinizing hormone, serum ferritin, serum folic acid, vitamin B12 and testosterone, 3 immunologic items of complement 3, C reactive protein and immunoglobulin G, and 10 biochemical items of alkaline phosphatase, glucose, calcium, chloride, potassium, lactate dehydrogenase, sodium, urea, low density lipoprotein cholesterol, and adenosine deaminase. The out-of-control rates of biochemistry, immunoturbidimetric and chemiluminescence tests in both quality control patterns conformed with the clinical routine work requirements. (3) Comparison of quality control materials′ consumption: compared with manually performed quality control, weekly consumption of automatically performed chemiluminescent quality control materials decreased 37.5% (from 8 ml to 5 ml); weekly consumption of automatically performed immunoturbidimetric quality control materials decreased 33.3% (from 3 ml to 2 ml). (4)Comparison of staff workload and first sample testing time: compared with manually performed quality control, automatical quality control reduced manual work by about 156 steps per week, and the daily initial testing time was earlier by 15 min on average. The failure rate was 54.5% (37/64) during the early-stage application of the automated quality control which dropped to 10.2% (13/128) in the late-stage. Conclusion:The results of automated quality control detected in the pipeline system meet the quality indicators′ requirements of the laboratory, and the application of automated quality control can improve the quality control, save costs, reduce workload, and improve work efficiency.
5.Explore the reasons affecting the consistency of reference intervals established by two types of indirect methods for 34 biochemical analytes
Chaochao MA ; Yicong YIN ; Li LIU ; Qian LIU ; Xin LIU ; Ying ZHANG ; Liangyu XIA ; Ling QIU
Chinese Journal of Laboratory Medicine 2023;46(10):1083-1093
Objective:To compare the differences of reference intervals (RI) established by two types of indirect methods for 34 biochemical analytes, and to explore the possible factors that affect the consistency of the two methods.Methods:This was a retrospective study. Based on data of albumin (Alb), alkaline phosphatase (ALP), alanine aminotransferase (ALT), apolipoprotein A1(ApoA1), ApolipoproteinB (ApoB), aspartate aminotransferase (AST), calcium (Ca), cholinesterase (ChE), chloride (Cl), creatinine (Cr), high-sensitivity C-reactive protein (hsCRP), Cystatin (CysC), direct bilirubin (DBil), free fatty acid (FFA), glycated albumin(GA), gamma-glutamyltransferase (GGT), glucose (Glu), high density lipoprotein cholesterol (HDL-C), potassium (K), lactate dehydrogenase (LD), low density lipoprotein cholesterol (LDL-C), lipoprotein a [Lp (a)], sodium (Na), phosphorus (P), prealbumin (PA), superoxide dismutase (SOD), total bile acid (TBA), total bilirubin (TBil), total cholesterol (TC), total carbon dioxide (TCO 2), triglyceride (TG), total protein (TP), uric acid (UA) and urea (UR) of individuals who underwent physical examination at Peking Union Medical College Hospital from January 1, 2018 to December 31, 2019, Box-Cox algorithm was used to improve the data distribution and Tukey method was used to identify outliers. Variance component model was established, and standard deviation ratio (SDR) was calculated to determine whether the RIs of 34 biochemical analytes should be established according to age or sex The non-parametric method and kosmic algorithm were used to establish the RIs and 90% confidence intervals (CIs) of 34 biochemical analytes, and the coincidence of the 90% CIs of the reference limits for two methods was compared. Results:The skewness coefficients of ALP(male, female18-59), ALT, AST, hsCRP, DBil, GGT, Lp (a), TBA, TBil, TG, Glu, HDL-C(male) and CysC, GA, UR in the elderly group deviated from 0, and their kurtosis coefficients also deviated from 3. For these biochemical analytes, the point estimates of the RIs established by the two methods differed greatly and the 90% CIs did not overlap. The analytes with good normality were Alb, ApoA1, ApoB, Ca, ChE, Cl, Cr(E), CysC(18-59), FFA, GA(18-59), HDL-C(female), K, LDL-C, Na, P, PA, SOD, TC, TCO 2, TP and UR. The consistency is good. Except for Ca, 90% CIs of reference limits for some analyte between the two methods coincide with each other. Conclusions:The consistency of different indirect methods is affected by the normality of data.
6.Construction and improvement of lab automation system in emergency lab
Hui WANG ; Liangyu XIA ; Lian HOU ; Ermu XU ; Qian LIU ; Ling QIU
Chinese Journal of Laboratory Medicine 2022;45(11):1123-1130
Objective:By exploring a construction and improvement system for total lab automation in emergency lab, this work aims to improve the success rates of project implementation and the effective utilization of medical resources.Methods:Firstly, clarify the short board of current solution and determine the configuration of the TLA solution which include the number of pre-analytic, post-analytic modules and analyzers by workflow and data analysis which based on the data from 16th to 22nd September 2019. Secondly, define the basic principles and design the optional solutions. Thirdly, determine the final solution based on the simulation results. Fourthly, evaluate the effectiveness of the solution by comparing the turnaroud time (TAT) before and after implementation.Result:We upgrade the system to improve the automation level of the track by add 1 online centrifuge module and upgrade the capacity of online storage module from 9 000 samples to 15 000 samples, and increase the throughput of the clinical chemistry analyzers form 2 500 tests/h to 5 400 tests/h and immunoassay analyzers from 668 tests/h to 1 320 tests/h with no more space. The 95th percentile TAT (from sample check in to validation) have 33% reduction on the premise of 9% increase on the workload of clinical chemistry and immunoassay, and it is highly consistent with the results obtained by data simulation whose 95th percentile TAT is 67 min.Conclusion:Good uasge of workflow and data analysis in the stage of solution design can help to ensure that the result can meet the expectations of the clinicians and effective utilization of medical resources.
7.Case report of pseudoelevated serum testosterone in women and literature review
Wei LUO ; Li′an HOU ; Songlin YU ; Ying ZHANG ; Jialei YU ; Yicong YIN ; Li LIU ; Xiaoyue LIANG ; Xin LIU ; Yujun SU ; Shaowei XIE ; Ling QIU ; Liangyu XIA
Chinese Journal of Laboratory Medicine 2022;45(12):1275-1278
Objective:The characteristics of women with false elevated testosterone were analyze and the literature was reviewed to provide reference for clinical laboratory identification of false elevated testosterone.Methods:The characteristics of three patients with false elevated testosterone in Peking Union Medical College Hospital were analyzed retrospectively, and the results of different detection platforms and methods for the determination of testosterone levels were compared. International and domestic literatures related to false elevation of testosterone and detection methods of testosterone were searched for a comprehensive analysis from PUBMED and CNKI.Results:The levels of testosterone in 3 female patients were elevated by immunoassay and normal by mass spectrometry. They were excluded from the diagnosis of hyperandrogenemia. A total of 38 literatures related to testosterone detection were retrieved, of which 9 case reports of pseudohyperandrogenemia, among which 12 cases of pseudohyperandrogenemia were reported in 2 domestic literatures in 2021. All cases were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Previous studies have clearly indicated that the result of routine immunoassay in clinical laboratory for the determination of female testosterone have poor correlation with the results of LC-MS/MS, with varying degrees of deviation.Conclusions:Immunoassay tests for female testosterone is susceptible to interference and lead to elevated false results. It is suggested that clinical laboratories evaluate the detection methods used and establish a identification program, and confirm samples with suspected pseudoelevated testosterone elevation using other immune platforms or LC-MS/MS.
8.Screwdriver aspiration during implant surgery: case report and literature review
WU Lin ; KONG Fanzhi ; QIAN Liangyu ; QIU Chenguang ; SUN Hongtao ; SHE Peng
Journal of Prevention and Treatment for Stomatological Diseases 2022;30(8):582-587
Objective :
To discuss and summarize the preventive measures and treatment methods for aspiration/ingestion during dental procedures.
Methods :
One case of aspiration during an implant operation was reported, and the literature on aspiration/ingestion during oral procedures was reviewed.
Results:
An implant screwdriver accidentally slipped into the mouth of the patient during implant surgery. The patient experienced no obvious discomfort except a few coughs. The surgeon and assistant paused the procedure immediately to search for the screwdriver, but it was not found. The patient declared that there was no special abnormality, such as breathing disorder or chest distress, so we considered that the foreign body was ingestion. After the implant surgery was completed, no foreign body was found in the stomach via gastroscopy. Chest X-ray and CT showed a dense metal shadow in the lower lobe of the left lung. Under local anesthesia, bronchoscopy and biopsy forceps were used by respiratory physicians to clip out the foreign body. After removal of the foreign body, the patient had no obvious discomfort but a slight cough. Cephalexin and metronidazole were given for three days to prevent infection. Three days later, the patient had no complaints of respiratory discomfort. After reviewing the literature, we found that the operation should be paused immediately after aspiration/ingestion occurs during dental procedures and that the dental chair should be laid down to prevent the foreign body from descending deeper, which may increase the difficulty of removal and cause gastrointestinal and respiratory tract injury. The position of the foreign body should be determined by imaging examination, and the corresponding means to remove the foreign body should be performed.
Conclusion
Patients may have no obvious symptoms after aspiration/ingestion during dental procedures, and the foreign body can be removed after imaging examination.
9.Reference Intervals for Thyroid-Associated Hormones and the Prevalence of Thyroid Diseases in the Chinese Population
Yutong ZOU ; Danchen WANG ; Xinqi CHENG ; Chaochao MA ; Songbai LIN ; Yingying HU ; Songlin YU ; Liangyu XIA ; Honglei LI ; Yicong YIN ; Huaicheng LIU ; Dianxi ZHANG ; Kui ZHANG ; Xiaolan LIAN ; Tengda XU ; Ling QIU
Annals of Laboratory Medicine 2021;41(1):77-85
Background:
Thyroid diseases are highly prevalent worldwide, but their diagnosis remains a challenge. We established reference intervals (RIs) for thyroid-associated hormones and evaluated the prevalence of thyroid diseases in China.
Methods:
After excluding outliers based on the results of ultrasound screening, thyroid antibody tests, and the Tukey method, the medical records of 20,303 euthyroid adults, who visited the Department of Health Care at Peking Union Medical College Hospital from January 2014 to December 2018, were analyzed. Thyroid-associated hormones were measured by the Siemens Advia Centaur XP analyzer. The RIs for thyroid-associated hormones were calculated according to the CLSI C28-A3 guidelines, and were compared with the RIs provided by Siemens. The prevalence of thyroid diseases over the five years was evaluated and compared using the chi-square test.
Results:
The RIs for thyroid stimulating hormone (TSH), free thyroxine (FT4), free triiodothyronine (FT3), total thyroxine (TT4), and total triiodothyronine (TT3) were 0.71–4.92 mIU/L, 12.2–20.1 pmol/L, 3.9–6.0 pmol/L, 65.6–135.1 nmol/L, and 1.2–2.2 nmol/L, respectively. The RIs of all hormones except TT4 differed significantly between males and females. The RIs of TSH increased with increasing age. The prevalence of overt hypothyroidism, overt hyperthyroidism, subclinical hypothyroidism, and subclinical hyperthyroidism was 0.5% and 0.8%, 0.2% and 0.6%, 3.8% and 6.1%, and 3.3% and 4.7% in males and females, respectively, which differed from those provided by Siemens.
Conclusions
Sex-specific RIs were established for thyroid-associated hormones, and the prevalence of thyroid diseases was determined in the Chinese population.
10.Survey for variation of prevalence of hyperuricemia and its correlations with blood glucose and lipid in healthy adults receiv-ing physical examination at Peking Union Medical College Hospital from 2012 to 2017
Danchen WANG ; Yicong YIN ; Songlin YU ; Xiuzhi GUO ; Lian HOU ; Honglei LI ; Tingting YOU ; Qian CHENG ; Shaowei XIE ; Xinqi CHENG ; Liangyu XIA ; Ling QIU
Chinese Journal of Clinical Laboratory Science 2018;36(6):462-466
Objective To investigate the changes of prevalence of hyperuricemia ( HUA) and its correlations with blood glucose and lipid in healthy adults receiving physical examination at Peking Union Medical College Hospital (PUMCH) from 2012 to 2017. Meth-ods An observational approach was adopted for the data analysis.The test results of uric acid (UA),fasting blood glucose (FBG),to-tal cholesterol (TC),triacylglycerol (TG),low density lipoprotein cholesterol (LDL-C),high density lipoprotein cholesterol (HDL-C), creatinine (Cr) and Urea of 399 089 cases (206 881 males and 192 208 females) at PUMCH from January 2012 to December 2017 were collected and statistically analyzed.Results The total prevalence of HUA was 17.4% in which the prevalence of males was signif-icantly higher than that of females (25.6% vs 8.5%,χ2=20 234.850,P<0.01).During the years of 2012 to 2017,the prevalence of HUA was 26.5%,24.7%,28.6%,23.9%,24.8% and 24.5% in males,and 13.8%,6.3%,7.9%,6.1%,6.2% and 6.8% in females for each year respectively.The prevalence of HUA in males aged 18 to 64 years old was significantly higher than that in the age-matched fe-males (all P<0.05).However, the prevalence of HUA in males aged≥65 years old was similar to the age-matched females.There was no statistically significant difference of HUA prevalence between males and females aged ≥65 in 2013,2015,2016 and 2017 ( χ2=1.792,0.017,1.440 and 0.205 respectively;all P>0.05).The percentages of hyperlipidemia in both males and females of HUA group were higher than those of non-HUA group respectively (all P<0.01).The percentage of hyperglycemia in males of non-HUA group was higher than that of HUA group,but the percentage of hyperglycemia in females of non-HUA group was lower than that of HUA group ( all P<0.01).High levels of TC,TG and FBG were risk factors of HUA with increased OR values in increased concentrations of TC,TG and FBG,respectively.Conclusion During the recent 6 years, in healthy adults receiving physiced examination at PVMCH, the preva-lence of male HUA diagnosed was at overall high level,but the prevalence of female HUA was in decreasing and relatively stable trend. Hyperlipidemia and hyperglycemia should be the risk factors of HUA.


Result Analysis
Print
Save
E-mail