1.Percutaneous vertebroplasty with measured saturated bone cement injection for elderly patients with stage Ⅱ Kümmell's disease: a feasibility and clinical efficacy analysis
Liangbing GUO ; Baotian LI ; Long WANG ; Wentao JIANG ; Peilin LIU ; Kai SU ; Zhe SHAO ; Qingde WANG ; Wei MEI
Chinese Journal of Orthopaedic Trauma 2025;27(4):305-313
Objective:To investigate the feasibility and clinical efficacy of percutaneous vertebroplasty (PVP) with measured saturated bone cement injection in the treatment of elderly patients with stage Ⅱ Kümmell's disease.Methods:A retrospective analysis was conducted to analyze the clinical data of the 41 elderly patients with stage Ⅱ Kümmell's disease who had been treated at Department of Spinal Orthopedics, Zhengzhou Orthopedic Hospital from June 2017 to June 2023 by PVP with bone cement injection into the intravertebral vacuum cleft. According to the amount of bone cement injected, the patients were divided into a saturated volume group (bone cement injection metered ≥ 150% of the cleft volume preoperatively measured) in which there were 21 cases, 4 males and 17 females, aged (78.4±5.2) years and a conventional volume group (bone cement injection metered was 100% to 120% of the cleft volume preoperatively measured) in which there were 20 cases, 6 males and 14 females, aged (79.5±7.4) years. The operative time, vacuum cleft volume measured, actual volume of bone cement injected, and percentage of bone cement injected were compared between the 2 groups. Visual analogue scale (VAS) for pain and Oswestry disability index (ODI) were compared between preoperation, postoperative 3 days, and the final follow-up in the 2 groups, as well as between the 2 groups. Cement leakage and other complications were documented.Results:The differences in the preoperative general data were not statistically significant between the 2 groups, indicating comparability ( P>0.05). All the 41 elderly patients successfully completed their surgery. Follow-up time was (18.1±3.3) months. The operative time [(39.7±7.5) min], actual volume of bone cement injected [(5.6±0.9) mL], and percentage of bone cement injected (1.8%±0.3%) in the saturated volume group were all significantly greater than those in the conventional volume group [(35.5±4.9) min, (4.4±1.0) mL, and 1.2%±0.1%] ( P<0.05). Postoperatively, the incisions healed completely in all patients, with no such complications as cement-related adverse reactions. Cement leakage occurred in 2 patients in the conventional volume group, leading to lumbar pain or discomfort after activity, which was relieved by cement reinforcement and nail-rod internal fixation. VAS pain scores and ODIs at 3 d postoperatively and at the final follow-up were significantly improved in all patients compared with preoperation ( P<0.05). At the final follow-up, both VAS pain score and ODI in the saturated volume group improved significantly greater than those in the conventional volume group ( P<0.05). None of the patients had complications like cement displacement at the final follow-up. Conclusion:PVP with measured saturated bone cement injection into the intravertebral vacuum clefts is a safe and effective treatment for stage Ⅱ Kümmell's disease in elderly patients, offering a new minimally invasive option.
2.Comparative efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures
Wentao JIANG ; Zhe SHAO ; Kai SU ; Long WANG ; Peilin LIU ; Liangbing GUO ; Qiangqiang PAN ; Qingde WANG
Chinese Journal of Trauma 2025;41(6):557-564
Objective:To compare the efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures.Methods:A retrospective cohort study was conducted to analyze the clinical data of 58 patients with Anderson-D′Alonzo type II odontoid fractures admitted to Zhengzhou Orthopedic Hospital between January 2017 and September 2024, including 35 males and 23 females, aged 18-57 years [(39.3±9.0)years]. Anderson-D′Alonzo type II fractures were further classified as type IIA in 25 patients and type IIB in 33. Twenty-seven patients underwent O-arm assisted anterior internal fixation (O-arm navigation group), while 31 received C-arm guided anterior internal fixation (C-arm guidance group). The two groups were compared in terms of the operative duration, intraoperative blood loss, success rate for one-time guidewire placement, and intraoperative radiation exposure (anteroposterior and lateral views). At 3 days postoperatively, screw placement accuracy was evaluated via CT in both groups. Additionally, neck disability index (NDI) and visual analogue scale (VAS) scores were assessed preoperatively, at 1 week, 3 months postoperatively, and at the last follow-up. Bone union time and complication rate were also analyzed.Results:All the patients were followed up for 6-20 months [(13.1±3.4)months]. The O-arm navigation group exhibited significantly shorter operative duration [(91.1± 8.9)minutes] and less intraoperative blood loss [(38.9±8.2)ml], compared with (103.3±14.5)minutes and (47.3±9.1)ml in the C-arm guidance group ( P<0.01). The success rate for one-time guidewire placement was 100% (27/27) in the O-arm navigation group, significantly higher than 52% (16/31) in the C-arm guidance group ( P<0.01). Intraoperative radiation exposure for patients in the O-arm navigation group was lower in both anteroposterior view [(11 612.6±1 603.6)μSv] and lateral views [(29 738.2±6 602.5)μSv], compared with (40 638.0±9 431.9)μSv and (47 152.0±11 759.3)μSv in the C-arm guidance group ( P<0.01). CT scans at 3 days postoperatively revealed a 100% (27/27) screw placement accuracy in the O-arm navigation group, compared with 65% (20/31) in the C-arm guidance group ( P<0.01). Before operation, at 1 weeks and 3 months postoperatively, and at the last follow-up, NDI scores were (48.4±7.8)%, (21.0±3.1)%, (14.4±2.4)%, and (13.9±2.3)% in the O-arm navigation group, while they were (47.4±7.6)%, (20.9±3.2)%, (14.1±2.0)%, and (13.8±1.4)% in the C-arm guidance group ( P>0.05); VAS scores were 6.0(6.0, 7.0)points, 4.0(3.0, 4.0)points, 2.0(1.0, 2.0)points, and 2.0(1.0, 2.0)points in the O-arm navigation group, while they were 7.0(6.0, 7.0)points, 4.0(3.0, 5.0)points, 2.0(1.0, 3.0)points, and 2.0(2.0, 2.0)points in the C-arm guidance group ( P>0.05). The NDI and VAS scores in both groups were significantly improved at 1 weeks and 3 months postoperatively, and at the last follow-up compared to those preoperatively ( P<0.05), and were furtherly improved at 3 months postoperatively and at the last follow-up compared to those at 1 weeks postoperatively ( P<0.05), with no significant differences between those at 3 months postoperatively and at the last follow-up ( P>0.05). No significant difference was found in bone union time between the two groups ( P>0.05). The complication rate in the O-arm navigation group was 4% (1/27), lower than 29% (9/31) in the C-arm guidance group ( P<0.05). Conclusions:Compared with C-arm guidance, O-arm assisted anterior internal fixation for Anderson-D′Alonzo type II odontoid fractures can reduce operative duration and intraoperative blood loss, improve the success rate for one-time guidewire placement and screw accuracy, and decrease radiation exposure and complication rate.
3.Comparative efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures
Wentao JIANG ; Zhe SHAO ; Kai SU ; Long WANG ; Peilin LIU ; Liangbing GUO ; Qiangqiang PAN ; Qingde WANG
Chinese Journal of Trauma 2025;41(6):557-564
Objective:To compare the efficacy of O-arm navigation versus C-arm guidance for anterior internal fixation in the management of Anderson-D′Alonzo type II odontoid fractures.Methods:A retrospective cohort study was conducted to analyze the clinical data of 58 patients with Anderson-D′Alonzo type II odontoid fractures admitted to Zhengzhou Orthopedic Hospital between January 2017 and September 2024, including 35 males and 23 females, aged 18-57 years [(39.3±9.0)years]. Anderson-D′Alonzo type II fractures were further classified as type IIA in 25 patients and type IIB in 33. Twenty-seven patients underwent O-arm assisted anterior internal fixation (O-arm navigation group), while 31 received C-arm guided anterior internal fixation (C-arm guidance group). The two groups were compared in terms of the operative duration, intraoperative blood loss, success rate for one-time guidewire placement, and intraoperative radiation exposure (anteroposterior and lateral views). At 3 days postoperatively, screw placement accuracy was evaluated via CT in both groups. Additionally, neck disability index (NDI) and visual analogue scale (VAS) scores were assessed preoperatively, at 1 week, 3 months postoperatively, and at the last follow-up. Bone union time and complication rate were also analyzed.Results:All the patients were followed up for 6-20 months [(13.1±3.4)months]. The O-arm navigation group exhibited significantly shorter operative duration [(91.1± 8.9)minutes] and less intraoperative blood loss [(38.9±8.2)ml], compared with (103.3±14.5)minutes and (47.3±9.1)ml in the C-arm guidance group ( P<0.01). The success rate for one-time guidewire placement was 100% (27/27) in the O-arm navigation group, significantly higher than 52% (16/31) in the C-arm guidance group ( P<0.01). Intraoperative radiation exposure for patients in the O-arm navigation group was lower in both anteroposterior view [(11 612.6±1 603.6)μSv] and lateral views [(29 738.2±6 602.5)μSv], compared with (40 638.0±9 431.9)μSv and (47 152.0±11 759.3)μSv in the C-arm guidance group ( P<0.01). CT scans at 3 days postoperatively revealed a 100% (27/27) screw placement accuracy in the O-arm navigation group, compared with 65% (20/31) in the C-arm guidance group ( P<0.01). Before operation, at 1 weeks and 3 months postoperatively, and at the last follow-up, NDI scores were (48.4±7.8)%, (21.0±3.1)%, (14.4±2.4)%, and (13.9±2.3)% in the O-arm navigation group, while they were (47.4±7.6)%, (20.9±3.2)%, (14.1±2.0)%, and (13.8±1.4)% in the C-arm guidance group ( P>0.05); VAS scores were 6.0(6.0, 7.0)points, 4.0(3.0, 4.0)points, 2.0(1.0, 2.0)points, and 2.0(1.0, 2.0)points in the O-arm navigation group, while they were 7.0(6.0, 7.0)points, 4.0(3.0, 5.0)points, 2.0(1.0, 3.0)points, and 2.0(2.0, 2.0)points in the C-arm guidance group ( P>0.05). The NDI and VAS scores in both groups were significantly improved at 1 weeks and 3 months postoperatively, and at the last follow-up compared to those preoperatively ( P<0.05), and were furtherly improved at 3 months postoperatively and at the last follow-up compared to those at 1 weeks postoperatively ( P<0.05), with no significant differences between those at 3 months postoperatively and at the last follow-up ( P>0.05). No significant difference was found in bone union time between the two groups ( P>0.05). The complication rate in the O-arm navigation group was 4% (1/27), lower than 29% (9/31) in the C-arm guidance group ( P<0.05). Conclusions:Compared with C-arm guidance, O-arm assisted anterior internal fixation for Anderson-D′Alonzo type II odontoid fractures can reduce operative duration and intraoperative blood loss, improve the success rate for one-time guidewire placement and screw accuracy, and decrease radiation exposure and complication rate.
4.Percutaneous vertebroplasty with measured saturated bone cement injection for elderly patients with stage Ⅱ Kümmell's disease: a feasibility and clinical efficacy analysis
Liangbing GUO ; Baotian LI ; Long WANG ; Wentao JIANG ; Peilin LIU ; Kai SU ; Zhe SHAO ; Qingde WANG ; Wei MEI
Chinese Journal of Orthopaedic Trauma 2025;27(4):305-313
Objective:To investigate the feasibility and clinical efficacy of percutaneous vertebroplasty (PVP) with measured saturated bone cement injection in the treatment of elderly patients with stage Ⅱ Kümmell's disease.Methods:A retrospective analysis was conducted to analyze the clinical data of the 41 elderly patients with stage Ⅱ Kümmell's disease who had been treated at Department of Spinal Orthopedics, Zhengzhou Orthopedic Hospital from June 2017 to June 2023 by PVP with bone cement injection into the intravertebral vacuum cleft. According to the amount of bone cement injected, the patients were divided into a saturated volume group (bone cement injection metered ≥ 150% of the cleft volume preoperatively measured) in which there were 21 cases, 4 males and 17 females, aged (78.4±5.2) years and a conventional volume group (bone cement injection metered was 100% to 120% of the cleft volume preoperatively measured) in which there were 20 cases, 6 males and 14 females, aged (79.5±7.4) years. The operative time, vacuum cleft volume measured, actual volume of bone cement injected, and percentage of bone cement injected were compared between the 2 groups. Visual analogue scale (VAS) for pain and Oswestry disability index (ODI) were compared between preoperation, postoperative 3 days, and the final follow-up in the 2 groups, as well as between the 2 groups. Cement leakage and other complications were documented.Results:The differences in the preoperative general data were not statistically significant between the 2 groups, indicating comparability ( P>0.05). All the 41 elderly patients successfully completed their surgery. Follow-up time was (18.1±3.3) months. The operative time [(39.7±7.5) min], actual volume of bone cement injected [(5.6±0.9) mL], and percentage of bone cement injected (1.8%±0.3%) in the saturated volume group were all significantly greater than those in the conventional volume group [(35.5±4.9) min, (4.4±1.0) mL, and 1.2%±0.1%] ( P<0.05). Postoperatively, the incisions healed completely in all patients, with no such complications as cement-related adverse reactions. Cement leakage occurred in 2 patients in the conventional volume group, leading to lumbar pain or discomfort after activity, which was relieved by cement reinforcement and nail-rod internal fixation. VAS pain scores and ODIs at 3 d postoperatively and at the final follow-up were significantly improved in all patients compared with preoperation ( P<0.05). At the final follow-up, both VAS pain score and ODI in the saturated volume group improved significantly greater than those in the conventional volume group ( P<0.05). None of the patients had complications like cement displacement at the final follow-up. Conclusion:PVP with measured saturated bone cement injection into the intravertebral vacuum clefts is a safe and effective treatment for stage Ⅱ Kümmell's disease in elderly patients, offering a new minimally invasive option.
5.A clinical study of a novel manual screw placement based on anatomical study of the 7th cervical vertebra
Qinwei FAN ; Wensheng LIAO ; Yanzheng GAO ; Zhongpei ZHU ; Hongwei CHEN ; Yipeng ZHU ; Liangbing GUO
Chinese Journal of Orthopaedic Trauma 2023;25(4):335-340
Objective:To evaluate the feasibility, accuracy, effectiveness and safety of a novel manual placement of cervical 7 pedicle screws via the posterior approach of cervicothoracic junction.Methods:A retrospective case series study was conducted to analyze the 35 patients with injury to the lower cervical spine or cervicothoracic junction who had been treated by a novel manual placement of cervical 7 pedicle screws at Department of Orthopedics, The First Affiliated Hospital of Zhengzhou University from March 2015 to July 2021. There were 16 males and 19 females, with an age of (52.7±13.2) years. The core of this placement was to determine the entry point of cervical 7 pedicle screws. After the intersection of the upper edge of the cervical 7 lamina and the medial edge of the superior articular process was recorded as point A while the intersection of the lateral edge of the inferior articular process and the lower edge of the transverse process as point B, the intersection of the outer and middle 1/3 of the AB line was taken as the screw entry point, with the screw placement angle perpendicular to the lamina line or slightly inclined from 30° to 40° to the head side and outward. The length, diameter and placement angle of the cervical 7 pedicle screws were recorded and compared postoperatively between the left and right sides to explore the feasibility of this novel manual placement. According to the Rampersaud method, the screw positions were graded 1 week and 6 months after operation to evaluate the accuracy of this manual placement. The visual analogue scale (VAS) and the Japanese Orthopaedic Association (JOA) score were compared between preoperation, 1 week and 6 months after operation to evaluate the effectiveness of this placement. The postoperative complications were counted to evaluate the safety of this method. Loosening, displacement and breakage of the screws were observed by CT scanning at 6 months after operation.Results:This case series was followed up for (9.8±1.7) months. There was no significant difference in the length, diameter or placement angle of the screws between the left and right sides ( P>0.05). A total of 66 cervical 7 pedicle screws were placed. There was no change in the screw position grading at 1 week or 6 months after surgery. Grade A was achieved in 64 screws, Grade B in 2 screws, and Grade C or D in none. The VAS scores before operation, 1 week and 6 months after operation were respectively 4.4±1.7, 3.8±1.0 and 1.1±1.1, and the JOA scores respectively 6.7±2.2, 13.2±1.5 and 15.3±1.2. The VAS and JOA scores at 1 week and 6 months after operation were significantly improved compared with the preoperative values ( P<0.05). The improvement rates in JOA at 1 week and 6 months after operation were 62.7%±13.3 % and 83.9%±11.6%, respectively. There were no complications related to the placement of cervical 7 pedicle screws; there was no wound hematoma or infection. No loosening, displacement or breakage of the screws was observed by the 6-month follow-up. Conclusion:The novel manual placement of cervical 7 pedicle screws via the posterior approach of cervicothoracic junction is feasible, accurate, effective and safe.
6. Research progress on the quality control of traditional Chinese medicine by the method of " quantitative analysis of multi-components by single marker" combined with fingerprint
Liangbing WEI ; Li SHAN ; Jiarong GAO ; Mingfei GUO ; Nannan JIANG
Chinese Journal of Primary Medicine and Pharmacy 2018;25(9):1220-1224
The method of " quantitative analysis of multi-components by single marker(QAMS)" combined with fingerprint often used in the quality control of traditional Chinese medicine (TCM) and its preparation.This study reviewed and analyzed the data.It showed that " QAMS" can be used in the determination of multiple indicators in some traditional Chinese medicine and Chinese herbal compound preparations.This is a supplementary method for the determination of content, combined with the fingerprint to mutual benefit, quality evaluation of TCM is more comprehensive and scientific.
7.Improving effects of Huangdi Anxiao Capsules on insulin resistance in type 2 diabetic GK rats
Mingfei GUO ; Jiarong GAO ; Zhaohui FANG ; Hui JIANG ; Jindong ZHAO ; Liangbing WEI ; Li SHAN ; Liping HAN ; Nannan JIANG
Chinese Traditional Patent Medicine 2017;39(8):1549-1554
AIM To observe the effects of Huangdi Anxiao Capsules (Puerariae lobatae Radix,Eriobotryae Folium,Notoginseng Radix et Rhizoma,etc.) on blood glucose and insulin resistance in GK rats with type 2 diabetes mellitus (T2DM) and its possible mechanism of action.METHODS GK rats with T2DM included in the experiment were randomly divided into model group,rosiglitazone (1.44 mg/kg) group,Shenqi Jiangtang Granules (1.08 g/kg) group,Huangdi Anxiao Capsules high,medium and low (12,6,3 g/kg) group and normal control group of Wistar rats.After six weeks of consecutive administration,fasting blood glucose (FBG),serum insulin (FINS),fasting plasma glucose (FPG),and insulin resistance index (HOMA-IR) were measured in all groups.Serum biochemical indexes of (TG,TC,HDL-C,LDL-C),glycosylated hemoglobin (HbA1c),glucagon-like peptide (GLP-1) and insulin-like growth factor (IGF-1) were measured.The pancreatic tissue was obtained by routine paraffin embedding and HE staining to observe the pathological changes.RESULTS Compared with the normal group,FBG,FPG,FINS,HOMA-IR,TG,TC,HDL-C,LDL-C and HbA1c of the model group were significantly higher (P <0.01),and GLP-1 and IGF-1 expressions were markedly decreased (P < 0.01).Compared with the model group,the levels of FBG,FPG,FINS,HOMA-IR,TG,TC,HDL-C,LDL-C and HbA1 c in Huangdi Anxiao Capsules high-,medium-and low-dose group were significantly decreased (P < 0.05,P <0.01);GLP-1 and IGF-1 expressions were markedly increased (P <0.05,P <0.01),compared with the model group,the structure changes of pancreatic tissue in Huangdi Anxiao Capsules high-,medium-and low-dose groups largely reduced.CONCLUSION Huangdi Anxiao Capsules can reduce GK rats fasting blood glucose,insulin resistance,and its mechanism may be related to promoting the emergence and proliferation of pancreatic islet cells,improving the function of islet beta cells,and increasing insulin secretion.

Result Analysis
Print
Save
E-mail