1.Therapeutic effects and mechanisms of M2 macrophage exosome spray on pressure injuries
Xiang YU ; Peipei JIA ; Xinying LI ; Junjun YANG ; Gaofeng GUO ; Lianfang LU
Journal of Pharmaceutical Practice and Service 2025;43(9):436-442
Objective To investigate the effects and underlying mechanisms of a spray prepared from exosomes derived from M2 macrophages induced by interleukin-4 (IL-4) and tantalum particles (Ta) on the healing of pressure ulcers. Methods Bone marrow-derived macrophages were polarized into M2 macrophages using IL-4 or Ta, and exosomes (Exo-IL-4/Exo-Ta) were extracted. The regulatory effects of Exo-IL-4/Exo-Ta on M1 macrophage phenotypes and fibroblast matrix secretion were evaluated in vitro. Proteomic analysis was conducted to explore the biological processes and regulatory networks associated with Exo-Ta. A rat pressure ulcer model was used to assess the effects of Exo-IL-4/Exo-Ta spray on wound healing rate, inflammatory cell infiltration, and collagen deposition. Results In vitro, Exo-IL-4/Exo-Ta induced the polarization of M1 macrophages to M2 macrophages, reduced the secretion of pro-inflammatory factors, and promoted the expression of anti-inflammatory substances. Additionally, Exo-IL-4/Exo-Ta enhanced the production of collagen and fibronectin in fibroblasts. Proteomic analysis revealed that Exo-Ta primarily participated in biological processes such as energy metabolism and macromolecule biosynthesis. In vivo, Exo-IL-4/Exo-Ta spray accelerated wound healing, reduced inflammatory infiltration, and improved tissue remodeling in the rat pressure ulcer model. Conclusion Exosome sprays derived from M2 macrophages could accelerate pressure ulcer healing by modulating inflammation and promoting tissue regeneration, which demonstrated excellent clinical application potential.
2.Targeted axillary dissection after neoadjuvant chemotherapy for highly selective patients with initial cN1 breast cancer: A single-center prospective trial
Xiuchun CHEN ; Zhenduo LU ; Chengzheng WANG ; Minhao LYU ; Jianghua QIAO ; Xianfu SUN ; Lianfang LI ; Chongjian ZHANG ; Zhenzhen LIU
Chinese Medical Journal 2024;137(12):1421-1430
Background::Sentinel lymph node (SLN) biopsy is gradually accepted as the standard of care in breast cancer patients with down-staged axillary disease after neoadjuvant chemotherapy (NAC). However, it is still difficult to precisely define pre-NAC clinical node-positive (cN1) and post-NAC clinical node-negative (ycN0). This prospective single-center trial was designed to evaluate the feasibility and accuracy of standard targeted axillary dissection (TAD) after NAC in highly selective pre-NAC cN1 patients (not considering ultrasound-based axillary ycN staging).Methods::This prospective trial included patients with initial pre-NAC cT1–3N1M0 invasive breast cancer but with a rigorous definition of cN1 from the Affiliated Cancer Hospital of Zhengzhou University. When NAC was effective (including complete and partial responses) and preoperative axillary palpation was negative, preoperative ultrasound-based axillary staging was not considered, and all patients underwent TAD followed by axillary lymph node (LN) dissection. The detection rate (DR) and false-negative rate (FNR) of TAD were calculated.Results::A total of 82 patients were included, and 77 of them were eligible for data analysis. The DR for TAD was 94.8% (73/77). There were 26 patients with one abnormal LN at the time of diagnosis based on ultrasound, 45 patients with two, and 2 patients with three. One patient had one TAD LN, four patients had two TAD LNs, and 68 patients had three or more TAD LNs. Preoperative axillary palpation yielded negative results for all 73 patients who successfully underwent TAD. Preoperative ultrasound-based ycN0 and ycN+ conditions were detected for 52 and 21 cases, respectively. The FNR was 7.4% (2/27) for standard TAD (≥3 SLNs), which was lower than that of all successful TAD (≥1 SLN; 10.0%, 3/30).Conclusions::In rigorously defined pre-NAC cN1 breast cancer patients, standard TAD is feasible for those with negative axillary palpation after NAC, and FNR is also less than 10%.Registration::chictr.org.cn, ChiCTR2100049093
3.Measurement of IL-1β,IL-6,IFN-γ levels in peripheral blood of lung cancer patients using multiple microsphere flow immunofluorescence technique and correlation analysis with hs-CRP
Fang WANG ; Lianfang LIU ; Lei WANG ; Guoxin XU ; Li HE ; Qinfeng ZHOU
International Journal of Laboratory Medicine 2024;45(21):2561-2565
Objective To investigate the expression of interleukin(IL)-1β,IL-6 and interferon γ(IFN-γ)cytokines in peripheral blood of patients with lung cancer detected by multiple microsphere flow immunofluo-rescence technique and to analyze the correlation with hypersevsitive C-reactive protein(hs-CRP).Methods A retrospective study was conducted to select 30 patients with lung cancer patients admitted to De-partment of Oncology and Department of Pulmonary Diseases in Zhangjiagang Hospital of Traditional Chinese Medicine(the hospital)as the lung cancer group,select 30 patients with pneumonia admitted in the hospital during the same period as the pneumonia group,and select 30 healthy people who underwent the physical ex-amination in the hospital in the same period as the control group.The serum levels of IL-1β,IL-6 and IFN-γwere detected by multiple microsphere flow immunofluorescence technique.Meanwhile,the level of hs-CRP in peripheral blood was determined by latex enhanced immunoscattering nephelometry.Results Compared with the control group,the levels of IL-1β,IL-6 and hs-CRP in lung cancer group were significantly increased,and the differences were statistically significant(P<0.001),while the difference in the level of IFN-γ was not sta-tistically significant(P>0.05).Compared with the control group,the levels of IL-1β,IL-6,IFN-γ and hs-CRP in the pneumonia group were significantly increased,and the differences were statistically significant(P<0.001).Compared with pneumonia group,the levels of IL-6,IFN-γ and hs-CRP in lung cancer group were sig-nificantly decreased and IL-1β level was increased,and the differences were statistically significant(P<0.05).Pearson correlation analysis was conducted on the levels of IL-6 and hs-CRP in the lung cancer group and pneumonia group,but no significant correlation was observed.Conclusion IL-1β,IL-6 and IFN-γ could be used as auxiliary indexes to effectively evaluate the immune function of patients with lung cancer.The applica-tion of multiple microsphere flow immunofluorescence technique has potential clinical application value for the diagnosis and monitoring of lung cancer.
4.Effects of three rehydration methods on prevention of on-site and delayed blood donation-related vasovagal responses: a cluster-randomized trial
Guiyun XIE ; Shijie LI ; Jian OUYANG ; Fanfan FENG ; Xiaoxiao ZHENG ; Zhiyu ZHOU ; Lianfang MAI ; Jinyan CHEN
Chinese Journal of Blood Transfusion 2024;37(1):43-50
【Objective】 To compare the effects of 3 rehydration methods before blood donation on the prevention of on-site and delayed blood donation-related vasovagal response (VVR) . 【Methods】 From January to June 2021, 6 250 whole blood donors in 6 fixed blood donation sites signed informed consent and were divided into 198 clusters according to donor sites and dates, then they were randomly assigned to receive either oral rehydration salts (ORS), sugar water, or water group, and each drank 500 mL of ORS, sugar water or water within 20 minutes before blood donation. The researchers recorded the actual intervention accepted on site, and recorded the immediate VVR and related information. At rest after blood donation, donors submitted an electronic questionnaire containing socio-demographic information. At 48 hours after blood donation, the researchers called back every donor to record delayed VVR and related information. Logistic regression based on intention to treat (ITT) was used to analyze the difference of the incidence of VVR among the three groups, and the average treatment effect on treated (ATT) was calculated. PASS 2021was used to estimate the sample size and R (4.2.0) for statistical analysis. 【Results】 The cumulative incidence of blood donation-related VVR was 2.67% (2.29%-3.11%) among street whole blood donors under the 3 rehydration methods, in which, the incidence of immediate and delayed VVR was 1.02% (0.79%-1.31%) and 1.65% (1.36%-2.01%) respectively. ITT analysis found that ORS were more effective than water in reducing the incidence of delayed VVR【OR=0.59,95% CI[0.37,0.94]】.There was no significant difference in the incidence of immediate VVR between any two groups (P > 0.05), and there was no significant difference in the incidence of delayed VVR in the sugar water group compared with the water group (P > 0.05). There was a difference of -0.013 (【95% CI[-0.022, -0.004]】or -0.008【95% CI[-0.017, -0.000]】in the incidence of delayed VVR in the ORS group compared with water group or sugar water group, the difference was significant (P<0.05). The cumulative VVR of the three groups showed similar results to the delayed VVR. 【Conclusion】 Drinking ORS before blood donation is the most effective rehydration method to prevent delayed VVR. The next step is to establish the predictive model of delayed VVR to screen the susceptible population and provide them with ORS before blood donation, while other population can choose any liquid they like, thus achieving personalized blood donation-related VVR prevention and control.
5.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
6.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
7.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
8.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
9.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.
10.Development of a Usability Scale for Smart Hospital Platforms Based on QoE Theory
Peipei JIA ; Xiaowei WANG ; Meihua LI ; Lianfang LU ; Juan FENG ; Hanxu LANG ; Lili WEI
Chinese Hospital Management 2024;44(11):70-73
Objective To construct a usability scale for smart hospital platforms based on Quality of Experience(QoE)theory,and provide scientific measurement tool for the construction,operation,and improvement of smart hospitals.Method Literature review,focus meeting method,and pre survey were used to screen and revise the scale items,forming a formal scale.Using convenience sampling method,1 000 users from 8 smart hospital platforms in Shandong Province were selected as the research subjects to evaluate the reliability and validity of the scale.Result The availability scale of the smart hospital platform includes 6 dimensions and 24 items.Exploratory factor extraction identified 6 common factors,with a cumulative variance contribution rate of 64.045%.The overall Cronbach's with a coefficient of 0.941 for 6 dimensions.The coefficient is between 0.782 and 0.963,and the retest reliability is 0.967.The Average Standardized Content Validity Index is 0.972,and the Item-level Content Validity Index is between 0.86 and 1.00.The correlation coefficient between the six dimensions of the scale and the System Usability Scale is 0.606-0.653,and the overall correlation coefficient is 0.647.Conclusion The usability scale of the smart hospital platform developed based on QoE theory has good reliability and validity,and can be used to measure the user experience of the smart hospital platform.

Result Analysis
Print
Save
E-mail