1.Review of chemical constituents, pharmacological effects, and quality control status of Eucommiae Cortex and prediction of its Q-markers.
Meng-Fan PENG ; Bao-Song LIU ; Pei-Pei YAN ; Cai-Xia LI ; Xiao-Fang ZHANG ; Yi ZHENG ; Ya-Gang SONG ; Tong LIU ; Lei YANG ; Ming-San MIAO
China Journal of Chinese Materia Medica 2025;50(4):946-958
Eucommiae Cortex, the dried bark of Eucommia ulmoides( Eucommiaceae), has both medicinal and edible values.Modern research has shown that Eucommiae Cortex contains various components such as flavonoids, lignans, iridoids, phenolic acids,terpenoids, and steroids, which have anti-osteoporosis, antioxidant, anti-inflammatory, blood glucose-lowering, and gastrointestinal tract-protecting effects. Eucommiae Cortex has applications in multiple fields such as healthcare, industry, and animal husbandry,demonstrating broad development prospects. This article reviews the chemical constituents, pharmacological effects, and quality control status of Eucommiae Cortex. Furthermore, according to the concept of quality marker(Q-marker), this article predicts the Q-markers of Eucommiae Cortex from traditional medicinal properties, traditional medicinal effects, new medicinal effects, measurability of chemical components, compatibility, harvesting periods, and geographical origins. The components such as pinoresinol diglucoside,chlorogenic acid, caffeic acid, quercetin, baicalein, baicalin, olivil, coniferyl ferulate, and kaempferol can be used as Q-markers for Eucommiae Cortex, which provide reference for establishing a systematic quality control system for Eucommiae Cortex.
Eucommiaceae/chemistry*
;
Drugs, Chinese Herbal/pharmacology*
;
Quality Control
;
Humans
;
Animals
2.Synaptic Vesicle Glycoprotein 2A Slows down Amyloidogenic Processing of Amyloid Precursor Protein via Regulating Its Intracellular Trafficking.
Qian ZHANG ; Xiao Ling WANG ; Yu Li HOU ; Jing Jing ZHANG ; Cong Cong LIU ; Xiao Min ZHANG ; Ya Qi WANG ; Yu Jian FAN ; Jun Ting LIU ; Jing LIU ; Qiao SONG ; Pei Chang WANG
Biomedical and Environmental Sciences 2025;38(5):607-624
OBJECTIVE:
To reveal the effects and potential mechanisms by which synaptic vesicle glycoprotein 2A (SV2A) influences the distribution of amyloid precursor protein (APP) in the trans-Golgi network (TGN), endolysosomal system, and cell membranes and to reveal the effects of SV2A on APP amyloid degradation.
METHODS:
Colocalization analysis of APP with specific tagged proteins in the TGN, ensolysosomal system, and cell membrane was performed to explore the effects of SV2A on the intracellular transport of APP. APP, β-site amyloid precursor protein cleaving enzyme 1 (BACE1) expressions, and APP cleavage products levels were investigated to observe the effects of SV2A on APP amyloidogenic processing.
RESULTS:
APP localization was reduced in the TGN, early endosomes, late endosomes, and lysosomes, whereas it was increased in the recycling endosomes and cell membrane of SV2A-overexpressed neurons. Moreover, Arl5b (ADP-ribosylation factor 5b), a protein responsible for transporting APP from the TGN to early endosomes, was upregulated by SV2A. SV2A overexpression also decreased APP transport from the cell membrane to early endosomes by downregulating APP endocytosis. In addition, products of APP amyloid degradation, including sAPPβ, Aβ 1-42, and Aβ 1-40, were decreased in SV2A-overexpressed cells.
CONCLUSION
These results demonstrated that SV2A promotes APP transport from the TGN to early endosomes by upregulating Arl5b and promoting APP transport from early endosomes to recycling endosomes-cell membrane pathway, which slows APP amyloid degradation.
Amyloid beta-Protein Precursor/genetics*
;
Membrane Glycoproteins/genetics*
;
Animals
;
Protein Transport
;
Nerve Tissue Proteins/genetics*
;
Humans
;
Mice
;
Endosomes/metabolism*
;
trans-Golgi Network/metabolism*
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Experimental study of the ultraviolet A-riboflavin cross-linking corneal stro-mal lenticule punctal plug for the treatment of dry eyes in rabbits
Fan YANG ; Fang TIAN ; Cheng PEI ; Juan LI ; Yong LI ; Yi SHAO
Recent Advances in Ophthalmology 2025;45(4):286-290
Objective To investigate the efficacy of the ultraviolet A-riboflavin cross-linking corneal stromal lenticule punctal plug for the treatment of dry eyes in rabbits.Methods Thirty-two New Zealand white rabbits(64 eyes)were se-lected and randomly divided into a normal group,a model group,a conventional plug group and a cross-linking plug group,with 8 rabbits(16 eyes)in each group.Rabbits in the normal group were not treated.In the model group,moderate-to-se-vere dry eye rabbit models were constructed but no treatment was given.Rabbits in the conventional and cross-linking plug groups were implanted with conventional and cross-linking plugs after model construction,respectively.The tear film func-tions of the experimental rabbits,including tear secretion volume(SIT),corneal fluorescein sodium staining,tear film break-up time(BUT),and tear meniscus height(TMH),were detected before the intervention,1 day,1 week,2 weeks,and 4 weeks after the intervention.In addition,the corneas of each group were collected for hematoxylin and eosin(HE)staining to observe the changes of the corneal epithelium 4 weeks after the intervention.Finally,the non-cross-linking and cross-linking corneal stromal lenticules were placed separately in 1 g·L-1 of type Ⅰ collagenase to observe the change of the lenticule diameter over time.Results In the cross-linking plug group,the SIT,BUT and TMH values 2 and 4 weeks after the intervention were significantly higher than those before the intervention(all P<0.01).In the conventional plug group,the SIT,BUT and TMH values 4 weeks after intervention were significantly higher than those before the intervention(all P<0.01).After 4 weeks of intervention,the corneal staining of rabbits in the cross-linking plug group was better than that in the conventional plug group and model group.The HE staining results showed that in the cross-linking plug group,the corneal epithelial thickness of rabbits was basically normal,epithelial cells were basically arranged in order,and a single layer of columnar epithelial cells was observed on the basal layer.The dissolution time of the corneal stromal lenticule after cross-linking was significantly increased,compared with that of the non-cross-linking one.Conclusion The ultraviolet A-riboflavin cross-linking corneal stromal lenticule punctal plug has a more stable therapeutic effect on the rabbit dry-eye model than the conventional one,so it is expected to provide a novel approach for the clinical treatment of dry eyes.
8.Feature of Cardiovascular-kidney-metabolic Syndrome Among Ethnic Minorities in Yunnan,China
Nuerguli TUERDI ; Xue CAO ; Yujie ZHANG ; Zixuan DONG ; Weiping LI ; Fan LI ; Xin WANG ; Congyi ZHENG ; Yixin TIAN ; Chenye CHANG ; Xuyan PEI ; Qinglan JIA ; Jialu YANG ; Zengwu WANG
Chinese Circulation Journal 2025;40(10):1022-1029
Objectives:To investigate the epidemiological characteristics and ethnic differences of cardiovascular-kidney-metabolic syndrome(CKM)among the Hani,Dai,Bai,and Lisu populations in Yunnan Province,and to provide evidence for developing effective prevention and control strategies for CKM.Methods:A cross-sectional survey was conducted among four ethnic minority groups.A total of 3 906 permanent residents aged 18 years and older were enrolled using a multistage cluster random sampling method.CKM stages(0-4)were defined based on the 2023 American Heart Association criteria,stages 3-4 were classified as advanced CKM.Descriptive statistics and chi-square tests were used to compare the prevalence of CKM stages across ethnic groups.Modified Poisson regression was applied to estimate relative risk(RR)and 95%confidence intervals(CI)for factors associated with advanced CKM.Results:The prevalence rates of CKM stage 1 and above among the Hani,Dai,Bai and Lisu ethnic groups were 80.1%,87.3%,84.8%and 67.8%,respectively.The prevalence of CKM was generally higher in males than in females,and the prevalence of CKM increased significantly with age.The Dai ethnic group had the highest prevalence of advanced CKM(24.7%,95%CI:22.1%-27.4%),while the Lisu ethnic group had the lowest prevalence of advanced CKM(13.7%,95%CI:11.5%-15.9%).Modified Poisson regression analysis showed that older age and higher body mass index were common risk factors for advanced CKM across all four ethnic groups.Additionally,except for the Lisu ethnic group,the other three ethnic groups had specific individual risk factors:among the Hani ethnic group,low educational attainment(RR=2.18,95%CI:1.12-4.25)and low income(RR=1.47,95%CI:1.00-2.18)were the primary risk factors of CKM.Among the Dai ethnic group,smoking(RR=1.60,95%CI:1.07-2.37)and a family history of cardiovascular disease(RR=1.61,95%CI:1.14-2.27)are the primary risk factors of CKM.Among the Bai ethnic group,male gender(RR=0.48,95%CI:0.29-0.79)was the primary risk factor of CKM.Conclusions:The prevalence of CKM stage 1 or higher is relatively high among the four minority ethnic groups in Yunnan province.There are significant differences in staging characteristics and primary risk factors across ethnic groups,necessitating the development of stratified,differentiated intervention strategies to achieve precise prevention and control and ethnic health equity in terms of CKM.
9.Impact of ischemia time and storage periods on RNA quality of fresh-frozen breast cancer and esophageal cancer tissue samples in biobank
Yang-si ZHENG ; Xuan-hao LIN ; Fan LI ; Kun-sheng XIAO ; Xi-feng CHEN ; Chun-peng LIU ; Pei-xiu YAO ; Shao-hong WANG
Fudan University Journal of Medical Sciences 2025;52(3):437-445
Objective To investigate the effects of ischemia time and storage periods on RNA quality in fresh-frozen breast cancer(BC)and esophageal cancer(EC)tissue samples in order to establish evidence-based protocols for biobank sample management.Methods The tumor(T)and paired normal(N)tissue samples from 6 cases of BC and 6 cases of EC were collected and cryopreserved in Biobank,Shantou Central Hospital.Mirror paraffin-embedded tissues were simultaneously prepared into sections for morphological analysis.The samples were divided into two groups of<15 min and 15-30 min according to ischemia time,and RNA quality was analyzed at 4 storage periods of 8-10 months(T1),14-16 months(T2),26-28 months(T3)and 38-40 months(T4).Results In 96 analyzed samples,93.8%(90/96)exhibited high quality(RIN≥6),with 89.6%(43/48)in BC and 97.9%(47/48)in EC.Significant differences in RIN were observed between BC group and EC group(8.050 vs.8.600,P=0.009).In EC group,RIN value was significantly negatively correlated with RNA yield(P<0.001).Moreover,RIN values of tumor-normal pairs exhibited markedly significant differences(7.550 vs.9.000,P<0.001).In contrast,no significant difference was detected in BC group(8.200 vs.7.700,P=0.348).Statistical analysis showed that RIN value was positively correlated with 28S/18S(P<0.001),but had no correlation with tumor content(P=0.676)and necrotic content(P=0.055).Neither ischemia time(<15 min vs.15-30 min:8.200 vs.8.300,P=0.932)nor storage periods(T1-T4:8.400,7.700,8.450,8.600,P=0.163)compromised RNA quality.Conclusion Organ origin and tissue type could influence RNA quality of fresh-frozen tissue samples.However,limited ischemia time(≤30 min)and long-term storage period(38-40 months)do not adversely affect RNA quality in fresh-frozen breast cancer and esophageal cancer tissue samples.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail