1.Telpegfilgrastim for chemotherapy-induced neutropenia in breast cancer: A multicenter, randomized, phase 3 study.
Yuankai SHI ; Qingyuan ZHANG ; Junsheng WANG ; Zhong OUYANG ; Tienan YI ; Jiazhuan MEI ; Xinshuai WANG ; Zhidong PEI ; Tao SUN ; Junheng BAI ; Shundong CANG ; Yarong LI ; Guohong FU ; Tianjiang MA ; Huaqiu SHI ; Jinping LIU ; Xiaojia WANG ; Hongrui NIU ; Yanzhen GUO ; Shengyu ZHOU ; Li SUN
Chinese Medical Journal 2025;138(4):496-498
2.Clinical outcomes and prognostic factors of pemphigus vulgaris and pemphigus foliaceus: A 20-year retrospective study.
Hongda LI ; Wenchao LI ; Zhenzhen WANG ; Shan CAO ; Pengcheng HUAI ; Tongsheng CHU ; Baoqi YANG ; Yonghu SUN ; Peiye XING ; Guizhi ZHOU ; Yongxia LIU ; Shengli CHEN ; Qing YANG ; Mei WU ; Zhongxiang SHI ; Hong LIU ; Furen ZHANG
Chinese Medical Journal 2025;138(10):1239-1241
3.Usefulness of intraoperative choledochoscopy in laparoscopic subtotal cholecystectomy for severe cholecystitis
Rui-Hui ZHANG ; Xiang-Nan WANG ; Yue-Feng MA ; Xue-Qian TANG ; Mei-Ju LIN ; Li-Jun SHI ; Jing-Yi LI ; Hong-Wei ZHANG
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(2):192-198
Laparoscopic subtotal cholecystectomy (LSC) has been a safe and viable alternative to conversion to laparotomy in cases of severe cholecystitis. The objective of this study is to determine the utility of intraoperative choledochoscopy in LSC for the exploration of the gallbladder, cyst duct, and subsequent stone clearance of the cystic duct in cases of severe cholecystitis. A total of 72 patients diagnosed with severe cholecystitis received choledochoscopy-assisted laparoscopic subtotal cholecystectomy (CALSC). A choledochoscopy was performed to explore the gallbladder cavity and/or cystic duct, and to extract stones using a range of techniques. The clinical records, including the operative records and outcomes, were subjected to analysis. No LSC was converted to open surgery, and no bile duct or vascular injuries were sustained. All stones within the cystic duct were removed by a combination of techniques, including high-frequency needle knife electrotomy, basket, and electrohydraulic lithotripsy. A follow-up examination revealed the absence of residual bile duct stones, with the exception of one common bile duct stone, which was extracted via endoscopic retrograde cholangiopancreatography. In certain special cases, CALSC may prove to be an efficacious treatment for the management of severe cholecystitis. This technique allows for optimal comprehension of the situation within the gallbladder cavity and cystic duct, facilitating the removal of stones from the cystic duct and reducing the residue of the non-functional gallbladder remnant.
4.Phase changes and quantity-quality transfer of raw material, calcined decoction pieces, and standard decoction of Ostreae Concha (Ostrea rivularis).
Hong-Yi ZHANG ; Jing-Wei ZHOU ; Jia-Wen LIU ; Wen-Bo FEI ; Shi-Ru HUANG ; Yu-Mei CHEN ; Chong-Yang LI ; Fei-Fei LI ; Qiao-Ling MA ; Fu WANG ; Yuan HU ; You-Ping LIU ; Shi-Lin CHEN ; Lin CHEN ; Hong-Ping CHEN
China Journal of Chinese Materia Medica 2025;50(5):1209-1223
The phase changes and quantity-quality transfer of 17 batches of Ostreae Concha(Ostrea rivularis) during the raw material-calcined decoction pieces-standard decoction process were analyzed. The content of calcium carbonate(CaCO_3), the main component, was determined by chemical titration, and the extract yield and transfer rate were calculated. The CaCO_3 content in the raw material, calcined decoction pieces, and standard decoction was 94.39%-98.80%, 95.03%-99.22%, and 84.58%-90.47%, respectively. The process of raw material to calcined decoction pieces showed the yield range of 96.85% to 98.55% and the CaCO_3 transfer rate range of 96.92% to 99.27%. The process of calcined decoction pieces to standard decoction showed the extract yield range of 2.86% to 5.48% and the CaCO_3 transfer rate range of 2.59% to 5.13%. The results of X-ray fluorescence(XRF) assay showed that the raw material, calcined decoction pieces, and standard decoction mainly contained Ca, Na, Mg, Si, Br, Cl, Al, Fe, Cr, Mn, and K. The chemometric results showed an increase in the relative content of Cr, Fe, and Si from raw material to calcined decoction pieces and an increase in the relative content of Mg, Al, Br, K, Cl, and Na from calcined decoction pieces to standard decoction. X-ray diffraction(XRD) was employed to establish XRD characteristic patterns of the raw material, calcined decoction pieces, and standard decoction. The XRD results showed that the main phase of all three was calcite, and no transformation of crystalline form or generation of new phase was observed. Fourier transform infrared spectroscopy(FTIR) was employed to establish the FTIR characteristic spectra of the raw material, calcined decoction pieces, and standard decoction. The FTIR results showed that the raw material had internal vibrations of O-H, C-H, C=O, C-O, and CO■ groups. Due to the loss of organic matter components after calcination, no information about the vibrations of C-H, C=O, and C-O groups was observed in the spectra of calcined decoction pieces and standard decoction. In summary, this study elucidated the quantity-quality transfer and phase changes in the raw material-calcined decoction pieces-standard decoction process by determining the CaCO_3 content, calculating the extract yield and transfer rate, and comparing the element changes, FTIR characteristic spectra, and XRD characteristic pattern. The results were reasonable and reliable, laying a foundation for the subsequent process research and quality control of the formula granules of calcined Ostreae Concha(O. rivularis Gould), and providing ideas and methods for the quality control of the whole process of raw material-decoction pieces-standard decoction-formula granules of Ostreae Concha and other testacean traditional Chinese medicine.
Drugs, Chinese Herbal/isolation & purification*
;
Calcium Carbonate/analysis*
;
Quality Control
5.Mechanism related to bile acids metabolism of liver injury induced by long-term administration of emodin.
Jing-Zhuo TIAN ; Lian-Mei WANG ; Yan YI ; Zhong XIAN ; Nuo DENG ; Yong ZHAO ; Chun-Ying LI ; Yu-Shi ZHANG ; Su-Yan LIU ; Jia-Yin HAN ; Chen PAN ; Chen-Yue LIU ; Jing MENG ; Ai-Hua LIANG
China Journal of Chinese Materia Medica 2025;50(11):3079-3087
Emodin is a hydroxyanthraquinone compound that is widely distributed and has multiple pharmacological activities, including anti-diarrheal, anti-inflammatory, and liver-protective effects. Research indicates that emodin may be one of the main components responsible for inducing hepatotoxicity. However, studies on the mechanisms of liver injury are relatively limited, particularly those related to bile acids(BAs) metabolism. This study aims to systematically investigate the effects of different dosages of emodin on BAs metabolism, providing a basis for the safe clinical use of traditional Chinese medicine(TCM)containing emodin. First, this study evaluated the safety of repeated administration of different dosages of emodin over a 5-week period, with a particular focus on its impact on the liver. Next, the composition and content of BAs in serum and liver were analyzed. Subsequently, qRT-PCR was used to detect the mRNA expression of nuclear receptors and transporters related to BAs metabolism. The results showed that 1 g·kg~(-1) emodin induced hepatic damage, with bile duct hyperplasia as the primary pathological manifestation. It significantly increased the levels of various BAs in the serum and primary BAs(including taurine-conjugated and free BAs) in the liver. Additionally, it downregulated the mRNA expression of farnesoid X receptor(FXR), retinoid X receptor(RXR), and sodium taurocholate cotransporting polypeptide(NTCP), and upregulated the mRNA expression of cholesterol 7α-hydroxylase(CYP7A1) in the liver. Although 0.01 g·kg~(-1) and 0.03 g·kg~(-1) emodin did not induce obvious liver injury, they significantly increased the level of taurine-conjugated BAs in the liver, suggesting a potential interference with BAs homeostasis. In conclusion, 1 g·kg~(-1) emodin may promote the production of primary BAs in the liver by affecting the FXR-RXR-CYP7A1 pathway, inhibit NTCP expression, and reduce BA reabsorption in the liver, resulting in BA accumulation in the peripheral blood. This disruption of BA homeostasis leads to liver injury. Even doses of emodin close to the clinical dose can also have a certain effect on the homeostasis of BAs. Therefore, when using traditional Chinese medicine or formulas containing emodin in clinical practice, it is necessary to regularly monitor liver function indicators and closely monitor the risk of drug-induced liver injury.
Emodin/administration & dosage*
;
Bile Acids and Salts/metabolism*
;
Animals
;
Male
;
Liver/injuries*
;
Chemical and Drug Induced Liver Injury/genetics*
;
Drugs, Chinese Herbal/adverse effects*
;
Humans
;
Rats, Sprague-Dawley
;
Mice
;
Rats
6.Effect of the sequence of intermediate instrumentation and distraction-reduction of the injured vertebra on the treatment of thoracolumbar burst fractures with high rate of spinal canal encroachment.
Yue WANG ; Liang-Sheng LI ; Heng-Mei CHEN ; Hai-Lun ZHENG ; Shi-Jie CHEN ; Jian-Quan CHEN ; Chun WANG
China Journal of Orthopaedics and Traumatology 2025;38(5):508-516
OBJECTIVE:
To investigate the effect of the sequence of intermediate instrumentation and distraction-reduction of the injured vertebra on the surgical efficacy of short-segment percutaneous pedicle screw fixation for thoracolumbar burst fractures with high rate of spinal canal encroachment.
METHODS:
From January 2016 to January 2022, 38 patients with thoracolumbar burst fractures with high rate of spinal canal encroachment (spinal canal encroachment rate >40%, complete posterior longitudinal ligament, no flipping bone block in the posterior marginal of the vertebra) without spinal cord injury who were were treated with short-segment percutaneous pedicle screw fixation were retrospectively analyzed. During the operation, 18 cases were used distraction-reduction first and then intermediate instrumentation on injured vertebral and sequential distraction-reduction again(the distraction-reduction first group) including 8 females and 10 males with a mean age of 46.5 (38.5, 50.0) years old, and the other 20 cases were used intermediate instrumentation on injured vertebral first and then direct distraction-reduction(the intermediate instrumentation first group) including 10 males and 10 females with a mean age of 46.0 (35.8, 50.8) years. The anterior height ratio of the injured vertebra, local Cobb's angle of the injured vertebrae, the spinal canal encroachment rate, and the improvement rate of spinal canal encroachment were compared and evaluated.
RESULTS:
All patients were followed up for more than 1 year, and no complications such as spinal cord and root injury, screw loosening and screw rod fracture were found. The anterior height ratio of the injured vertebra, local Cobb' angle of the injured vertebra in the two groups were significantly improved compared with preoperative data(P<0.05), and those at 3 months and 1 year after operation was lost compared with that at the previous time point(P<0.05). Although the spinal canal encroachment rate of the two groups 1 day and 1 year after operation was improved compared with that before operation(P<0.05), the improvement of spinal canal volume in the distraction-reduction first group was significantly better than that in the intermediate instrumentation first group (P<0.01).
CONCLUSION
In the treatment of patients with thoracolumbar fractures with high rate of spinal canal encroachment, short-segment percutaneous pedicle screw internal fixation with distraction-reduction first and then intermediate instrumentation and sequential distraction-reduction again can more effectively reduce the bony encroachment in the spinal canal and achieve indirect decompression effect better.
Humans
;
Female
;
Male
;
Adult
;
Middle Aged
;
Spinal Fractures/surgery*
;
Thoracic Vertebrae/surgery*
;
Lumbar Vertebrae/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Pedicle Screws
;
Retrospective Studies
;
Spinal Canal/surgery*
7.Application of genome tagging technology in elucidating the function of sperm-specific protein 411 (Ssp411).
Xue-Hai ZHOU ; Min-Min HUA ; Jia-Nan TANG ; Bang-Guo WU ; Xue-Mei WANG ; Chang-Gen SHI ; Yang YANG ; Jun WU ; Bin WU ; Bao-Li ZHANG ; Yi-Si SUN ; Tian-Cheng ZHANG ; Hui-Juan SHI
Asian Journal of Andrology 2025;27(1):120-128
The genome tagging project (GTP) plays a pivotal role in addressing a critical gap in the understanding of protein functions. Within this framework, we successfully generated a human influenza hemagglutinin-tagged sperm-specific protein 411 (HA-tagged Ssp411) mouse model. This model is instrumental in probing the expression and function of Ssp411. Our research revealed that Ssp411 is expressed in the round spermatids, elongating spermatids, elongated spermatids, and epididymal spermatozoa. The comprehensive examination of the distribution of Ssp411 in these germ cells offers new perspectives on its involvement in spermiogenesis. Nevertheless, rigorous further inquiry is imperative to elucidate the precise mechanistic underpinnings of these functions. Ssp411 is not detectable in metaphase II (MII) oocytes, zygotes, or 2-cell stage embryos, highlighting its intricate role in early embryonic development. These findings not only advance our understanding of the role of Ssp411 in reproductive physiology but also significantly contribute to the overarching goals of the GTP, fostering groundbreaking advancements in the fields of spermiogenesis and reproductive biology.
Animals
;
Female
;
Humans
;
Male
;
Mice
;
Spermatids/metabolism*
;
Spermatogenesis/physiology*
;
Spermatozoa/metabolism*
;
Thioredoxins/genetics*
8.Clinical Characteristics and Prognostic Analysis of Newly Diagnosed Acute Myeloid Leukemia Patients with NRAS and KRAS Gene Mutations.
Zhang-Yu YU ; Bo CAI ; Yi WANG ; Yang-Yang LEI ; Bing-Xia LI ; Yu-Fang LI ; Yan-Ping SHI ; Jia-Xin CHEN ; Shu-Hong LIU ; Chang-Lin YU ; Mei GUO
Journal of Experimental Hematology 2025;33(3):682-690
OBJECTIVE:
To retrospectively analyze the clinical characteristics, co-mutated genes in newly diagnosed acute myeloid leukemia (AML) patients with NRAS and KRAS gene mutations, and the impact of NRAS and KRAS mutations on prognosis.
METHODS:
The clinical data and next-generation sequencing results of 80 newly diagnosed AML patients treated at our hospital from December 2018 to December 2023 were collected. The clinical characteristics, co-mutated genes of NRAS and KRAS , and the impact of NRAS and KRAS mutations on prognosis in newly diagnosed AML patients were analyzed.
RESULTS:
Among 80 newly diagnosed AML patients, NRAS mutations were detected in 20 cases(25.0%), and KRAS mutations were detected in 9 cases(11.3%). NRAS mutations predominantly occurred at codons 12 and 13 of exon 2, as well as codon 61 of exon 3, while KRAS mutations were most commonly occurred at codons 12 and 13 of exon 2, all of which were missense mutations. There were no statistically significant differences observed in terms of age, sex, white blood cell count(WBC), hemoglobin(Hb), platelet count(PLT), bone marrow blasts, first induction chemotherapy regimen, CR1/CRi1 rates, chromosome karyotype, 2022 ELN risk classification and allogeneic hematopoietic stem cell transplantation(allo-HSCT) among the NRAS mutation group, KRAS mutation group and NRAS/KRAS wild-type group (P >0.05). KRAS mutations were significantly correlated with PTPN11 mutations (r =0.344), whereas no genes significantly associated with NRAS mutations were found. Survival analysis showed that compared to the NRAS/KRAS wild-type group, patients with NRAS mutation had a relatively higher 5-year overall survival (OS) rate and relapse-free survival (RFS) rate, though the differences were not statistically significant (P =0.097, P =0.249). Compared to the NRAS/KRAS wild-type group, patients with KRAS mutation had a lower 5-year OS rate and RFS rate, with no significant differences observed (P =0.275, P =0.442). There was no significant difference in the 5-year RFS rate between the KRAS mutation group and NRAS mutation group (P =0.157), but the 5-year OS rate of patients with KRAS mutation was significantly lower than that of patients with NRAS mutation (P =0.037).
CONCLUSION
In newly diagnosed AML patients, KRAS mutation was significantly correlated with PTPN11 mutation. Compared to patients with NRAS/KRAS wild-type, those with NRAS mutation showed a more favorable prognosis, while patients with KRAS mutation showed a poorer prognosis; however, these differences did not reach statistical significance. Notably, the prognosis of AML patients with KRAS mutation was significantly inferior compared to those with NRAS mutation.
Humans
;
Leukemia, Myeloid, Acute/diagnosis*
;
Mutation
;
Prognosis
;
Proto-Oncogene Proteins p21(ras)/genetics*
;
GTP Phosphohydrolases/genetics*
;
Retrospective Studies
;
Membrane Proteins/genetics*
;
Female
;
Male
;
Middle Aged
;
Adult
;
Aged
9.Application Practice of AI Empowering Post-discharge Specialized Disease Management in Postoperative Rehabilitation of the Lung Cancer Patients Undergoing Surgery.
Mei LI ; Hongbing ZHANG ; Chunqiu XIA ; Yuqi ZHANG ; Huihui JI ; Yi SHI ; Liran DUAN ; Lingyu GUO ; Jinghao LIU ; Xin LI ; Ming DONG ; Jun CHEN
Chinese Journal of Lung Cancer 2025;28(3):176-182
BACKGROUND:
Lung cancer is the leading malignancy in China in terms of both incidence and mortality. With increased health awareness and the widespread use of low-dose computed tomography (CT), early diagnosis rates have been steadily improving. Surgical intervention remains the primary treatment option for early-stage lung cancer, and video-assisted thoracoscopic surgery (VATS) has become a common approach due to its minimal invasiveness and rapid recovery. However, post-discharge recovery remains incomplete, underscoring the importance of postoperative care. Traditional follow-up methods, lack standardization, consume significant medical resources, and increase the burden of the patients. Artificial intelligence (AI)-driven disease management platforms offer a novel solution to optimize postoperative follow-up. This study followed 463 lung cancer surgery patients using an AI-based platform, aiming to identify common postoperative issues, propose solutions, improve quality of life, reduce recurrence-related costs, and promote AI integration in healthcare.
METHODS:
Using the AI disease management platform, this study integrated educational videos, collaboration between healthcare teams and AI assistants, daily health logs, health assessment forms, and personalized interventions to monitor postoperative recovery. The postoperative rehabilitation status of the patients was assessed by the Leicester Cough Questionnaire (LCQ-MC). Two independent t-test and one-way ANOVA were used to analyze the causes of postoperative cough in lung cancer.
RESULTS:
Most issues occurred within 7 d post-discharge, significantly declined on 14 d post-discharge. Factors such as gender, smoking history, and surgical approaches were found to influence cough recovery. The incidence of cough on 7 d post-discharge in females was higher than that in males (P<0.01), while the incidence of cough on 14 d post-discharge in elderly patients was lower than that in young patients (P=0.03). The AI-based platform effectively addressed cough, pain, and sleep disturbances through phased interventions.
CONCLUSIONS
The AI-based platform significantly enhanced postoperative management efficiency and the self-care capabilities of the patients, particularly in phased cough management. Future integration with wearable devices could enable more precise and personalized postoperative care, further advancing the application of AI technology across multidisciplinary healthcare domains.
Humans
;
Lung Neoplasms/rehabilitation*
;
Male
;
Female
;
Middle Aged
;
Aged
;
Patient Discharge
;
Artificial Intelligence
;
Adult
;
Postoperative Care
;
Postoperative Period
;
Disease Management
;
Quality of Life
10.Robot-assisted percutaneous coronary intervention: a prospective, multicenter, randomized controlled, non-inferiority clinical trial.
Yi YU ; Zheng CHEN ; Zhi-Jian WANG ; Yue-Ping LI ; Li-Xia YANG ; Jing QI ; Jing XIE ; Tao HUANG ; Dong-Mei SHI ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(8):725-735
OBJECTIVE:
To evaluate the safety and effectiveness of robot-assisted percutaneous coronary intervention (R-PCI) compared to traditional manual percutaneous coronary intervention (M-PCI).
METHODS:
This prospective, multicenter, randomized controlled, non-inferior clinical trial enrolled patients with coronary heart disease who met the inclusion criteria and had indications for elective percutaneous coronary intervention. Participants were randomly assigned to either the R-PCI group or the M-PCI group. Primary endpoints were clinical and technical success rates. Clinical success was defined as visually estimated residual post-percutaneous coronary intervention stenosis < 30% with no 30-day major adverse cardiac events. Technical success in the R-PCI group was defined as successful completion of percutaneous coronary intervention using the ETcath200 robot-assisted system, without conversion to M-PCI in the event of a guidewire or balloon/stent catheter that was unable to cross the vessel or was poorly supported by the catheter. Secondary endpoints included total procedure time, percutaneous coronary intervention procedure time, fluoroscopy time, contrast volume, operator radiation exposure, air kerma, and dose-area product.
RESULTS:
The trial enrolled 152 patients (R-PCI: 73 patients, M-PCI: 79 patients). Lesions were predominantly B2/C type (73.6%). Both groups achieved 100% clinical success rate. No major adverse cardiac events occurred during the 30-day follow-up. The R-PCI group had a technical success rate of 100%. The R-PCI group had longer total procedure and fluoroscopy times, but lower operator radiation exposure. The percutaneous coronary intervention procedure time, contrast volume, air kerma, and dose-area product were similar between the two groups.
CONCLUSIONS
For certain complex lesions, performing percutaneous coronary intervention using the ETcath200 robot-assisted system is safe and effective and does not result in conversion to M-PCI.

Result Analysis
Print
Save
E-mail