1.Acellular dermal matrix hydrogel promotes skin wound healing in rats
Xiaohong LIU ; Tian ZHAO ; Yunping MU ; Wenjin FENG ; Cunsheng LYU ; Zhiyong ZHANG ; Zijian ZHAO ; Fanghong LI
Chinese Journal of Tissue Engineering Research 2026;30(2):395-403
BACKGROUND:Promoting skin wound healing is a huge challenge facing global public health.To promote faster and higher-quality wound healing,it is necessary to explore more advantageous dressings to address this problem.OBJECTIVE:To investigate the hemostatic properties of acellular dermal matrix hydrogel and its effect on skin wound healing.METHODS:(1)Acellular dermal matrix hydrogel was prepared,and the differences in microscopic morphology and main components between it and acellular dermal matrix were analyzed.(2)Acellular dermal matrix hydrogel and chitosan hydrogel were used to cover the femoral artery puncture site of rats,and the bleeding quality and coagulation time were recorded.Acellular dermal matrix hydrogel and chitosan hydrogel were mixed with rat anticoagulated blood,and the coagulation index within 30 minutes was detected.(3)A full-thickness skin defect model with a diameter of 12 mm was made on the back of 18 SD rats,and they were randomly divided into 3 groups,with 6 rats in each group:the model group used PBS to clean the wound,and the control group and the experimental group used chitosan hydrogel and acellular dermal matrix hydrogel to cover the wound,respectively.The hydrogel dressing was changed every day,and the treatment was continued for 14 days,and the wound healing was observed.On day 3 after modeling,immunofluorescence staining of inducible nitric oxide synthase(M1 macrophages)and CD206(M2 macrophages)was performed on the wound surface.On day 14 after modeling,hematoxylin-eosin staining,Masson staining,and CD31 immunohistochemical staining were performed on the wound surface.RESULTS AND CONCLUSION:(1)Scanning electron microscopy revealed that the acellular dermal matrix hydrogel had a porous structure,and the Fourier transform infrared spectrum showed that it had the same main components as the acellular dermal matrix.(2)Both acellular dermal matrix hydrogel and chitosan hydrogel had obvious hemostatic ability in vivo.In the in vitro coagulation experiments,the coagulation index of acellular dermal matrix hydrogel was significantly higher than that of chitosan hydrogel.(3)In the rat skin full-thickness defect model,both acellular dermal matrix hydrogel and chitosan hydrogel could improve the wound healing rate.Hematoxylin-eosin and Masson staining results showed that acellular dermal matrix hydrogel could reduce the infiltration of inflammatory cells in the center of the wound.Both acellular dermal matrix hydrogel and chitosan hydrogel could decrease scar width and increase collagen deposition rate.CD31 immunohistochemical staining results showed that both hydrogels could promote angiogenesis in the wound site.Immunofluorescence staining results showed that both hydrogels could reduce the proportion of M1 macrophages and increase the proportion of M2 macrophages,and the effect of acellular dermal matrix hydrogel was stronger than that of chitosan hydrogel.(4)The results show that the acellular dermal matrix hydrogel has good hemostatic properties and the ability to promote wound healing.
2.High tibial osteotomy on a single plane:femorofibular angle as a reference marker for mechanical axis correction
Xiaomin LI ; Xiangdong TIAN ; Chaolu WANG
Chinese Journal of Tissue Engineering Research 2026;30(3):570-576
BACKGROUND:The femorofibular angle is a commonly used reference angle for mechanical axis correction in high tibial osteotomy on a single plane,but there has been no in-depth study on the application of this angle in high tibial osteotomy on a single plane.OBJECTIVE:To explore the application effect of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane.METHODS:A retrospective analysis was conducted on 64 cases of knee osteoarthritis patients who underwent high tibial osteotomy on a single plane at Third Affiliated Hospital of Beijing University of Chinese Medicine from January 2023 to January 2024.The patients were grouped according to the intraoperative mechanical axis correction reference method.The observation group consisted of 32 cases,which used the femorofibular angle as a reference for mechanical axis correction during surgery.The control group consisted of 32 cases,which used electrocautery line measurement as a reference for mechanical axis correction during surgery.Both groups received the same perioperative treatment and management.The lower limb mechanical axis ratio,hip-knee-ankle angle,proximal medial tibial angle,and femorofibular angle were recorded before and after surgery to assess changes in the lower limb mechanical state.The operation time and number of fluoroscopies were recorded.The visual analog scale score and Lysholm score for pain and knee function were recorded before surgery and at 1 and 3 months after surgery to evaluate changes in knee pain and function.RESULTS AND CONCLUSION:(1)All patients completed the treatment and follow-up,and no serious adverse events occurred.(2)Before surgery,there was no statistically significant difference in the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle between the two groups(P>0.05).At 3 months after surgery,the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle were significantly improved in both groups compared to before surgery,with statistically significant differences(P<0.05).There was no significant difference between the two groups(P>0.05).(3)During surgery,the operation time and number of fluoroscopies in the observation group were less than those in the control group,with statistically significant differences(P<0.05).(4)At each follow-up point before and after surgery,there was no statistically significant difference in the visual analog scale score and Lysholm score between the two groups(P>0.05).With the passage of time after surgery,the visual analog scale score and Lysholm score in both groups were significantly improved compared to before surgery(P<0.05).(5)It is suggested that the application of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane can accurately locate the range of lower limb mechanical axis correction,is simple and reliable,and reduces the number of fluoroscopies and operation time compared to traditional electrocautery line measurement.
3.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
4.Effects of ammonia poisoning on cognitive behavior and hippocampal synaptic damage in mice
Jiuxuan ZHANG ; Jinnan ZHANG ; Xiaofan SUI ; Xiaxia PEI ; Jianhong WEI ; Qiang SU ; Tian LI
Chinese Journal of Tissue Engineering Research 2026;30(5):1122-1128
BACKGROUND:Ammonia poisoning is considered to be the main hypothesis for the pathogenesis of hepatic encephalopathy.Ammonia can lead to psychiatric and cognitive behavioral disorders,although the specific pathological molecular mechanisms remain unclear.OBJECTIVE:To investigate the effects of ammonia poisoning on cognitive behavior and hippocampal neuronal synapses in mice.METHODS:Thirty-two C57BL/6J mice were randomly divided into a normal control group and an ammonium chloride group,with 16 mice in each group.Normal saline was injected intraperitoneally in the control group,and ammonium chloride(10 mmol/kg)was injected intraperitoneally in the ammonium chloride group to construct a model of ammonia poisoning,once a day.After 7 days of ammonium chloride intervention,blood samples were collected from the hearts of six mice in each group for blood ammonia concentration detection.Behavioral experiments,including the open field test,novel object recognition test,and Y-maze test,were performed to assess mental and cognitive-behavioral changes in mice.Finally,hippocampal tissues were extracted for western blot analysis to detect the expression levels of synaptophysin and postsynaptic density protein-95 in hippocampal neurons.RESULTS AND CONCLUSION:The blood ammonia concentration was significantly elevated in the ammonium chloride group compared with the control group(P<0.05).Mice in the ammonium chloride group showed anxiety-like behavior and disinhibition phenomenon,and a significant decrease in recognition memory and working memory ability.Western blot results revealed that the expression of synaptophysin and postsynaptic density protein-95 protein in hippocampal neurons in the ammonium chloride group was lower than that in the control group(P<0.05).To conclude,ammonia poisoning can induce hippocampal neuronal synaptic damage,leading to psychiatric and cognitive behavioral abnormalities in mice.
5.Acellular dermal matrix hydrogel promotes skin wound healing in rats
Xiaohong LIU ; Tian ZHAO ; Yunping MU ; Wenjin FENG ; Cunsheng LYU ; Zhiyong ZHANG ; Zijian ZHAO ; Fanghong LI
Chinese Journal of Tissue Engineering Research 2026;30(2):395-403
BACKGROUND:Promoting skin wound healing is a huge challenge facing global public health.To promote faster and higher-quality wound healing,it is necessary to explore more advantageous dressings to address this problem.OBJECTIVE:To investigate the hemostatic properties of acellular dermal matrix hydrogel and its effect on skin wound healing.METHODS:(1)Acellular dermal matrix hydrogel was prepared,and the differences in microscopic morphology and main components between it and acellular dermal matrix were analyzed.(2)Acellular dermal matrix hydrogel and chitosan hydrogel were used to cover the femoral artery puncture site of rats,and the bleeding quality and coagulation time were recorded.Acellular dermal matrix hydrogel and chitosan hydrogel were mixed with rat anticoagulated blood,and the coagulation index within 30 minutes was detected.(3)A full-thickness skin defect model with a diameter of 12 mm was made on the back of 18 SD rats,and they were randomly divided into 3 groups,with 6 rats in each group:the model group used PBS to clean the wound,and the control group and the experimental group used chitosan hydrogel and acellular dermal matrix hydrogel to cover the wound,respectively.The hydrogel dressing was changed every day,and the treatment was continued for 14 days,and the wound healing was observed.On day 3 after modeling,immunofluorescence staining of inducible nitric oxide synthase(M1 macrophages)and CD206(M2 macrophages)was performed on the wound surface.On day 14 after modeling,hematoxylin-eosin staining,Masson staining,and CD31 immunohistochemical staining were performed on the wound surface.RESULTS AND CONCLUSION:(1)Scanning electron microscopy revealed that the acellular dermal matrix hydrogel had a porous structure,and the Fourier transform infrared spectrum showed that it had the same main components as the acellular dermal matrix.(2)Both acellular dermal matrix hydrogel and chitosan hydrogel had obvious hemostatic ability in vivo.In the in vitro coagulation experiments,the coagulation index of acellular dermal matrix hydrogel was significantly higher than that of chitosan hydrogel.(3)In the rat skin full-thickness defect model,both acellular dermal matrix hydrogel and chitosan hydrogel could improve the wound healing rate.Hematoxylin-eosin and Masson staining results showed that acellular dermal matrix hydrogel could reduce the infiltration of inflammatory cells in the center of the wound.Both acellular dermal matrix hydrogel and chitosan hydrogel could decrease scar width and increase collagen deposition rate.CD31 immunohistochemical staining results showed that both hydrogels could promote angiogenesis in the wound site.Immunofluorescence staining results showed that both hydrogels could reduce the proportion of M1 macrophages and increase the proportion of M2 macrophages,and the effect of acellular dermal matrix hydrogel was stronger than that of chitosan hydrogel.(4)The results show that the acellular dermal matrix hydrogel has good hemostatic properties and the ability to promote wound healing.
6.High tibial osteotomy on a single plane:femorofibular angle as a reference marker for mechanical axis correction
Xiaomin LI ; Xiangdong TIAN ; Chaolu WANG
Chinese Journal of Tissue Engineering Research 2026;30(3):570-576
BACKGROUND:The femorofibular angle is a commonly used reference angle for mechanical axis correction in high tibial osteotomy on a single plane,but there has been no in-depth study on the application of this angle in high tibial osteotomy on a single plane.OBJECTIVE:To explore the application effect of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane.METHODS:A retrospective analysis was conducted on 64 cases of knee osteoarthritis patients who underwent high tibial osteotomy on a single plane at Third Affiliated Hospital of Beijing University of Chinese Medicine from January 2023 to January 2024.The patients were grouped according to the intraoperative mechanical axis correction reference method.The observation group consisted of 32 cases,which used the femorofibular angle as a reference for mechanical axis correction during surgery.The control group consisted of 32 cases,which used electrocautery line measurement as a reference for mechanical axis correction during surgery.Both groups received the same perioperative treatment and management.The lower limb mechanical axis ratio,hip-knee-ankle angle,proximal medial tibial angle,and femorofibular angle were recorded before and after surgery to assess changes in the lower limb mechanical state.The operation time and number of fluoroscopies were recorded.The visual analog scale score and Lysholm score for pain and knee function were recorded before surgery and at 1 and 3 months after surgery to evaluate changes in knee pain and function.RESULTS AND CONCLUSION:(1)All patients completed the treatment and follow-up,and no serious adverse events occurred.(2)Before surgery,there was no statistically significant difference in the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle between the two groups(P>0.05).At 3 months after surgery,the lower limb mechanical axis ratio,proximal medial tibial angle,hip-knee-ankle angle,and femorofibular angle were significantly improved in both groups compared to before surgery,with statistically significant differences(P<0.05).There was no significant difference between the two groups(P>0.05).(3)During surgery,the operation time and number of fluoroscopies in the observation group were less than those in the control group,with statistically significant differences(P<0.05).(4)At each follow-up point before and after surgery,there was no statistically significant difference in the visual analog scale score and Lysholm score between the two groups(P>0.05).With the passage of time after surgery,the visual analog scale score and Lysholm score in both groups were significantly improved compared to before surgery(P<0.05).(5)It is suggested that the application of the femorofibular angle as a reference for mechanical axis correction in high tibial osteotomy on a single plane can accurately locate the range of lower limb mechanical axis correction,is simple and reliable,and reduces the number of fluoroscopies and operation time compared to traditional electrocautery line measurement.
7.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
8.Survey of post-discharge exercise behavior and analysis of factors influencing exercise intensity in patients undergoing lung surgery
Hongyu ZENG ; Xiang WANG ; Tian ZHANG ; Yaqin WANG ; Xing WEI ; Zhen DAI ; Liping ZHANG ; Xiaoqin LIU ; Qiang LI ; Qiuling SHI ; Wei DAI ; Jia LIAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):734-742
Objective To investigate the post-discharge exercise behavior and factors influencing moderate to vigorous intensity physical activity (MVPA) in patients undergoing lung surgery. Methods A total of 2874 patients from the large prospective, observational perioperative lung symptom study cohort (CN-PRO-Lung 3) in the Department of Thoracic Surgery at Sichuan Cancer Hospital between April 7, 2021, and January 31, 2024, were selected as the survey subjects. A survey was conducted using the Investigation of Exercise Behavior after Lung Surgery questionnaire and the International Physical Activity Questionnaire-Short Form (IPAQ-SF) among patients who underwent lung surgery. Binary logistic regression was used to analyze the factors influencing patients’ engagement in MVPA. Results A total of 702 patients were surveyed, including 252 males and 450 females, with an average age of (52.4±10.2) years. Patients with lung cancer accounted for 85.9%. Only 36.0% of the patients had regular exercise habits, while 42.3% did not engage in any physical activity. The three main barriers for postoperative exercise were physical discomfort (pain, coughing, shortness of breath, etc, 54.7%), lack of professional guidance (41.7%), and concerns about the surgical wound (28.9%). The proportions of patients engaging in vigorous, moderate, and low-intensity physical activity were 5.7%, 28.2%, and 66.1%, respectively. Multivariate analysis showed that patients with a personal annual income ≥50000 yuan (OR=1.52, 95%CI 1.01-2.29, P=0.044), high school education or above (OR=1.92, 95%CI 1.33-2.76, P<0.001), and lobectomy (OR=1.44, 95%CI 1.02-2.03, P=0.037) engaged in more MVPA. Conclusion Patients undergoing lung surgery have inadequate physical activity after discharge, particularly lacking in MVPA. Patients with higher income, higher educational levels, and lobectomy are more frequently engaged in MVPA. Measures such as symptom control, providing exercise guidance, and enhancing education on wound care may potentially improve the inadequate physical activity in lung surgery patients after discharge.
9.Visiting behavior and health management strategy of patients with cardiovascular disease under the family doctor contract service model
Juan LI ; Bingqi XING ; Wei WANG ; Yunfeng TIAN
Journal of Public Health and Preventive Medicine 2026;37(3):176-179
Objective To explore the visiting behavior and health management strategy of patients with cardiovascular disease (CVD) and the industry management strategies under the family doctor contract service model. Methods A total of 351 patients with CVD from January 2022 to January 2025 were included in the case investigation by random sampling. Taking the number of visits in community health service institutions/total number of visits ≥90% as high compliance, the influencing factors of the visiting behavior of CVD patients were analyzed. Results Finally, 344 valid questionnaires were collected, with an effective recovery rate of 98.01%. The study subjects were categorized into high compliance group (271 cases) and low compliance group (73 cases). The scores of policy cognition understanding, institutional trust and medical service understanding in the high compliance group were higher compared with those in the low compliance group (P<0.05). There was no significant difference in the understanding of medical expenses between the two groups (P>0.05). Multivariate logistic regression model analysis revealed that CVD duration [OR (95% CI): 1.72 (1.21-2.44)], policy cognition understanding [OR (95% CI): 2.16 (1.20-3.89)] and institutional trust [OR (95% CI): 1.88 (1.08-3.25)] were independently associated with medical treatment behavior in CVD patients (P<0.05). Conclusion Enhancing the policy cognition understanding and institutional trust of CVD patients on family doctor contract service can promote patients to seek medical treatment and promote the high-quality development of family doctor contract service.
10.Influencing Factors of Depression in Patients with Postoperative Ovarian Cancer
Jialiang YAO ; Long ZHANG ; Jianhui TIAN ; Ze LIU ; Yun YANG ; Yiyang ZHOU ; Minghua LI ; Wang YAO ; Wenfei SHI ; Xinyi LU ; Pan YU ; Enchao CONG
Cancer Research on Prevention and Treatment 2026;53(5):349-359
Objective To explore the prevalence of depressive symptoms in postoperative patients with ovarian cancer and to analyze its influencing factors from multiple dimensions, including clinical characteristics, psychological factors, and laboratory indicators. Methods A cross-sectional study was conducted, which enrolled 235 postoperative patients with ovarian cancer. Depressive status was assessed using the patient health questionnaire, and the demographic, pathological, and medical record data of the patients were collected using the generalized anxiety disorder scale, Pittsburgh sleep quality index, European organization for research and treatment of cancer quality of life questionnaire core 30, and ECOG performance status score. Peripheral blood tumor marker (CA125), routine blood test, lymphocyte subsets, and serum cytokine levels were measured. Univariate and multivariate binary logistic regression analysis were used for statistical analysis. Results The prevalence of depression in postoperative patients with ovarian cancer was 39.15% (92/235). Univariate analysis showed that ECOG score ≥ 2 points, pain, anxiety, poor sleep quality, low quality of life, low life satisfaction, tumor recurrence, six or more cycles of chemotherapy, as well as higher levels of CA125, NLR, and NAR, and lower hemoglobin levels were significantly associated with depression (all P<0.05). Multivariate binary Logistic regression analysis showed that anxiety (OR=1.975, 95%CI: 1.231-3.170), sleep efficiency (OR=4.181, 95%CI: 1.211-14.43), sleep latency (OR=34.806, 95%CI: 4.258-284.542), ECOG performance status score, cognitive function (OR=0.918, 95%CI: 0.868-0.97), and life satisfaction were independent risk factors for depression (all P<0.05). Laboratory indicators were not independent influencing factors in the multivariate Logistic regression model. Conclusion Depression in postoperative patients with ovarian cancer is influenced by physiological, psychological, and social factors. Clinical management should focus on patients with anxiety, sleep disorders, poor physical condition, and low life satisfaction, and a comprehensive prevention and treatment strategy centered on psychological intervention and taking into account symptom management and social support should be implemented.


Result Analysis
Print
Save
E-mail