1.Time series study on influence of sulfur dioxide exposure on hospitalization of chronic obstructive pulmonary disease in Lanzhou from 2016 to 2020
Sheng LIN ; Boxi FENG ; Yongyue LI ; Yiwei HUANG ; Kai ZHENG ; Mingxuan LIU ; Yingying YANG ; Xingmin WEI ; Jianjun WU
Journal of Environmental and Occupational Medicine 2026;43(4):451-457
Background In 2021, chronic obstructive pulmonary disease (COPD) emerged as the forth leading cause of death in the world. However, the impact of air pollutants on COPD is still inconsistent across current studies. Objective To analyze the relationship between ambient sulfur dioxide (SO2) exposure and hospital admissions for COPD in Lanzhou, and to examine the modified effects of SO2 across different genders, age groups, and seasons. Methods A total of
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
4.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
5.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
6.Three-dimensional Electrical Impedance Tomography for Monitoring Gastric Hemorrhage
Zi-Han ZHAO ; Bo SUN ; Jing-Shi HUANG ; Zhi-Wei LI ; Yang WU ; Nan LI ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2026;53(4):1062-1075
ObjectiveGastric hemorrhage is one of the most common and life-threatening emergencies of the upper digestive tract. Early identification and continuous monitoring are essential for reducing rebleeding rates and mortality, particularly within the critical early hours after onset. Although endoscopy and radiological imaging can accurately localize bleeding sites, these approaches are invasive, resource-intensive, and unsuitable for continuous bedside monitoring. Electrical impedance tomography (EIT), as a noninvasive and radiation-free functional imaging technique, offers real-time visualization of conductivity distribution and has the potential for detecting intragastric bleeding based on the electrical contrast between blood and surrounding gastric tissues. In this study, a three-dimensional gastric EIT (3D-gEIT) framework is proposed to achieve noninvasive, real-time, and dynamic monitoring of gastric hemorrhage, with emphasis on spatial localization and quantitative volume assessment. MethodsA three-dimensional upper-abdominal simulation model incorporating the stomach, gastric wall, gastric contents, and surrounding tissues was established. Three electrode configurations, namely the dual layer ring, the four layer staggered ring, and the opposed dual plane array, were designed and systematically compared to evaluate their influence on depth sensitivity and spatial resolution. Based on the Tikhonov-Noser hybrid regularization scheme, a region-clustering constraint was introduced to develop the TK-Noser-RCC algorithm. This approach aggregates spatially adjacent elements with similar conductivity variations, thereby enhancing structural continuity and suppressing isolated noise artifacts. To validate the proposed framework, an upper-abdominal physical phantom was constructed using agar to simulate background tissue conductivity. Hemispherical high-conductivity inclusions with volumes ranging from 10 ml to 50 ml were attached to the inner gastric wall to mimic localized bleeding under different gastric filling states. Boundary voltages were acquired under a 120 kHz excitation current and reconstructed using the TK-Noser-RCC algorithm. Furthermore, an in vivo animal experiment was performed using a porcine model with adult-scale abdominal dimensions. A total of 100 ml of autologous blood was injected incrementally into the stomach to simulate progressive gastric hemorrhage, and time-difference EIT reconstruction was conducted at each injection stage to assess the dynamic system response under physiological conditions. ResultsSimulation results demonstrated that the opposed dual-plane electrode array achieved superior depth sensitivity distribution and spatial resolution. For a 40 ml hemorrhage model, the average ICC and SSIM improved by 55.9% and 38.8% compared with the dual-layer ring configuration, and by 64.0% and 39.5% compared with the four-layer staggered configuration. The proposed region-clustering constraint significantly enhanced reconstruction stability. Under added Gaussian noise of 40 dB and 30 dB, ICC values remained approximately 0.85, indicating effective artifact suppression and preservation of boundary integrity. In physical phantom experiments, reconstructed hemorrhage volumes increased approximately linearly with the preset hemispherical volumes, and the reconstructed high-conductivity regions closely matched the actual bleeding locations. Both empty-stomach and full-stomach conditions were evaluated, demonstrating that the opposed dual-plane configuration maintained stable imaging performance across varying gastric contents. In the animal experiment, reconstructed low-impedance regions expanded progressively with increasing injected blood volume. The spatial localization of the hemorrhage remained stable throughout the procedure, and no significant artifacts were observed. Quantitative analysis showed that reconstructed volume and average conductivity variation exhibited an approximately linear growth trend with injected blood volume, confirming the sensitivity of the system to dynamic intragastric conductivity changes. ConclusionThe proposed 3D-gEIT framework enables quantitative reconstruction of gastric hemorrhage volume and spatial distribution with improved depth sensitivity, structural continuity, and noise robustness compared with conventional EIT approaches. By integrating optimized electrode configuration and a region-clustering-constrained reconstruction algorithm, the system provides stable dynamic monitoring under both controlled phantom conditions and in vivo physiological environments. This method offers a noninvasive, real-time, and low-cost imaging strategy for early diagnosis, postoperative monitoring, and bedside surveillance of gastric bleeding.
7.TGF-β1-engineered Biomimetic Platelet Nanoparticles for Targeted Therapy of Ischemic Stroke
Li-Qi CHEN ; Tian-Fang KANG ; Guo-Jun HUANG ; Ting YIN ; Ai-Qing MA ; Lin-Tao CAI ; Hong PAN
Progress in Biochemistry and Biophysics 2026;53(3):697-710
ObjectivePost-ischemic acute inflammation and the subsequent persistent dysregulation of the immune microenvironment represent major pathological drivers that aggravate neuronal injury and severely restrict functional recovery following ischemic stroke. Although current reperfusion therapies partially restore blood flow, they fail to effectively modulate the secondary inflammatory cascade and oxidative stress, which remain critical barriers to neurological restoration. To address this challenge, this study aimed to engineer and systematically evaluate a biomimetic nanosystem composed of transforming growth factor-β1 (TGF-β1)-loaded platelet membrane-camouflaged lipid nanoparticles (PLP). This nanosystem was designed to achieve dual lesion-targeted delivery and immune microenvironment remodeling. By verifying its spatiotemporal accumulation, anti-inflammatory activity, and neuroprotective efficacy, we sought to establish an integrated therapeutic strategy that simultaneously enables lesion targeting, immune regulation, and functional recovery after ischemic injury. MethodsThe physicochemical properties of PLP, including hydrodynamic particle size, zeta potential, structural stability, and morphology, were characterized using dynamic light scattering, zeta potential analysis, and transmission electron microscopy. The preservation of platelet membrane-derived adhesion and immunoregulatory proteins was confirmed by SDS-PAGE through comparative analysis of protein band profiles between PLP and native platelet membranes. The in vitro biological activities of PLP were evaluated using two complementary cellular models. LPS-induced M1-polarized RAW264.7 macrophages were employed to assess inflammatory modulation, while oxygen glucose deprivation/reperfusion (OGD/R)-induced BV2 microglial cells and SH-SY5Y neuronal cells were utilized to investigate neuroinflammatory regulation and neuronal protection. For in vivo validation, a transient middle cerebral artery occlusion (tMCAO) mouse model was established to mimic ischemia-reperfusion injury. The spatiotemporal biodistribution and lesion-targeting capability of the PLP were monitored through live fluorescence imaging. Therapeutic efficacy was comprehensively evaluated by triphenyltetrazolium chloride (TTC) staining, glial fibrillary acidic protein (GFAP) immunofluorescence analysis, body weight monitoring, and neurological severity score (NSS) assessment. ResultsPLP nanoparticles displayed a uniform spherical morphology, nanoscale particle size distribution, and stable negative surface charge, indicating favorable colloidal stability and circulation potential. SDS-PAGE results confirmed the effective retention of key platelet membrane proteins associated with endothelial adhesion, immune evasion, and inflammatory regulation, demonstrating the successful biomimetic construction. Optimal therapeutic concentrations were determined in OGD/R-induced BV2 cells, where PLP exhibited excellent cytocompatibility and anti-inflammatory activity.In vitro experiments demonstrated that PLP significantly inhibited the polarization of RAW264.7 macrophages toward the pro-inflammatory M1 phenotype and markedly reduced neuronal apoptosis under ischemia-reperfusion conditions. In vivo fluorescence imaging revealed that PLP rapidly accumulated in the ischemic brain hemisphere and maintained prolonged retention for up to 7 d, suggesting enhanced lesion-specific targeting and sustained drug release. Compared with control group, PLP treatment significantly reduced cerebral infarct volume, attenuated reactive astrogliosis, improved weight recovery, and accelerated neurological functional restoration, as reflected by significantly improved NSS scores. ConclusionThis study establishes a multifunctional biomimetic nanoplatform that integrates platelet membrane-mediated active targeting with the anti-inflammatory, antioxidative, and neuroprotective properties of TGF-β1. The PLP system enables rapid lesion homing and long-term retention while synergistically regulating the post-stroke inflammatory microenvironment by suppressing pro-inflammatory immune activation, reducing neuronal apoptosis, and limiting excessive astrocyte reactivity. Importantly, this study proposes a conceptually therapeutic paradigm that combines targeted delivery with immune microenvironment remodeling to achieve comprehensive neurovascular protection. These findings provide strong experimental evidence supporting the translational potential of biomimetic nanotherapeutics as next-generation precision interventions for ischemic stroke.
8.Study on the discrimination of roasting degree of Ziziphus jujuba based on the correlation of colorimetric values with component content
Yuan LI ; Yanmei LIU ; Cheng HUANG ; Tangyi PENG ; Yanquan HAN
China Pharmacy 2026;37(9):1148-1154
OBJECTIVE To investigate the correlation of component content with colorimetric values during the roasting process of Ziziphus jujuba , and to provide criteria for discriminating the roasting degree of Z. jujuba . METHODS Samples were prepared by dry stir-frying for different roasting times. The eight main components in raw Z. jujuba and the samples stir-fried for different roasting times-namely adenosine, magnoflorine, jujuboside A, spinosin, 6-feruloylspinosin, betulinic acid, oleic acid, and linoleic acid-were quantitativel y analyzed using ultra-performance liquid chromatography. The chromaticity values were determined using a UV spectrophotometer. The correlation and differences between the chromaticity values of Z. jujuba at different roasting times and their components content were analyzed by Pearson correlation analysis, linear regression analysis, principal component analysis (PCA) , cluster heatmap analysis (CHA), and partial least squares discriminant analysis (PLS-DA) to clarify the processing endpoint. RESULTS As the roasting time increased, the contents of linoleic acid and oleic acid decreased, while the contents of other components exhibited an increasing trend. Concurrently, the colorimetric value L* and E*ab were observed to decline, whereas the a* value demonstrated a gradual increase. Pearson correlation analysis revealed that L* and E*ab exhibited a significant negative correlation with the contents of adenosine, spinosin, 6-feruloylspinosin, jujuboside A, betulinic acid and magnoflorine ( P <0.05). The results of linear regression analysis indicate that the content of six components, including adenosine, in the medicinal material can be preliminarily predicted by analyzing the colorimetric values of Z. jujuba powder. PCA and CHA successfully classified raw and stir-fried samples. The PLS-DA results indicated that L*, E*ab, a*, linoleic acid content, and oleic acid content were the main parameters that differentiated the color and quality of Z. jujuba at different roasting times. After frying for 9 to 10 minutes, the colorimetric values L* and E*ab decreased to their minimum values and stabilized, while a* remained consistently high with little variation;simultaneously, the concentrations of the six major components, excluding linoleic acid and oleic acid, reached their peak levels. CONCLUSIONS A significant correlation between the colorimetric values of Z. jujuba and the contents of six components, including adenosine, is confirmed. The optimal roasting time range is determined to be 9-10 minutes. Furthermore, the colorimetric value-component content correlation analysis method established in this study proved to be practical and applicable for discriminating the roasting degree of Z. jujuba .
9.Cardiac-targeted liposomes alleviate myocardial ischemia-reperfusion injury by promoting inflammation resolution
Guangrui ZHU ; Xueyi WENG ; Weiyan LI ; Yanan SONG ; Zheyong HUANG
Chinese Journal of Clinical Medicine 2026;33(2):240-249
Objective To explore the pro-inflammation resolution and protective effects of reactive oxygen species (ROS)-responsive liposomes modified with a cardiac-targeted peptide and loaded with resolvin D1 (RvD1, C-LP-RvD1) on myocardial ischemia-reperfusion (MI/R) injury. Methods The C-LP-RvD1 nanoliposomes were constructed, characterized physically and chemically, and evaluated for in vitro release. Non-targeting peptide-modified drug-loaded liposomes (LP-RvD1) were served as controls. Apoptotic adult mouse cardiomyocytes (AMCMs) were used to verify in vitro targeted binding capacity of C-LP-RvD1. In MI/R mice models, the in vivo distribution and cardiac enrichment of C-LP-RvD1 were assessed. Levels of specialized pro-resolving mediator (SPM) and inflammatory factors in cardiac tissue homogenates and cell culture supernatants were measured using enzyme-linked immunosorbent assay (ELISA). Cardiac function and fibrosis remodeling were evaluated via echocardiography and Masson staining four weeks after treatment. Biosafety was evaluated in healthy mice injected by C-LP-RvD1. Results The C-LP-RvD1 exhibited good nanoscale uniformity and stability, with ROS-triggered accelerated release characteristics. In vitro experiments showed that C-LP-RvD1 had higher binding capacity to apoptotic AMCMs than LP-RvD1, with significantly higher SPM levels (P<0.01) and lower inflammatory factor levels (P<0.05). In vivo experiments indicated enhanced cardiac enrichment of C-LP-RvD1 in MI/R injured hearts, with higher local myocardial SPM levels and lower inflammatory factor levels compared to LP-RvD1 (P<0.05). Four weeks after treatment, compared with LP-RvD1, the C-LP-RvD1 mice group showed improved cardiac function indicators and reduced ventricular fibrosis remodeling ratio (P<0.05). Safety evaluation revealed no significant systemic inflammation, immunogenicity, or coagulation abnormalities in healthy mice, with liver and kidney function and major organ histology showing no notable damage. Conclusions C-LP-RvD1 improves effective delivery of RvD1 to MI/R injured hearts through injury-targeted enrichment and ROS-responsive release, promoting inflammation resolution and suppressing excessive inflammation, thereby improving cardiac function and reducing adverse remodeling, with favorable biosafety.
10.Comparison of clinical efficiency between neuroendoscope-assisted evacuation and navigation-assisted puncture in treating thalamic hemorrhage breaking into the ventricle
Yonghui HUANG ; Yang GAO ; Chen LI ; Puyuan ZHAO ; Tian HUAI ; Rujiang BAI ; Xuefu WANG
Chinese Journal of Clinical Medicine 2026;33(1):108-112
Objective To compare the clinical efficacy of neuroendoscope-assisted evacuation and navigation-assisted puncture drainage in treating thalamic hemorrhage breaking into the ventricle. Methods A retrospective analysis was conducted on the clinical data of 93 patients with thalamic hemorrhage breaking into the ventricle at Taihe Hospital of Wannan Medical College between January 2022 and February 2024. The patients received neuroendoscope-assisted removal of thalamic hematoma combined with contralateral extraventricular drainage (n=44, neuroendoscope group) and navigation-assisted thalamic hematoma puncture drainage combined with contralateral extraventricular drainage (n=49, navigation group), respectively. The treatment efficacy, surgical situation, and prognosis between the two groups were compared. Results The neuroendoscope group had longer operation duration, more intraoperative blood loss, higher hospitalization costs than the navigation group (P<0.05). The neuroendoscope group had higher hematoma clearance rate 3rd after surgery and shorter length of stay than the navigation group (P<0.05). There was no significant difference in the incidence of intracranial infection after surgery between the two groups. The neuroendoscope group had higher Glasgow coma scale (GCS) score at 1 week after surgery and Glasgow outcome scale (GOS) score at 3 months after surgery (P<0.01). Conclusions Compared with navigation-assisted puncture, neuroendoscope-assisted evacuation can improve the thalamic hemorrhage clearance rate, shorten the length of stay, and improve the prognosis of patients.

Result Analysis
Print
Save
E-mail