1.Standards for the Application of Hemodynamic Monitoring Technology in Critical Care
Hua ZHAO ; Hongmin ZHANG ; Xin DING ; Huan CHEN ; Jun DUAN ; Wei DU ; Bo TANG ; Yuankai ZHOU ; Dongkai LI ; Xinchen WANG ; Cui WANG ; Gaosheng ZHOU ; Xiaoting WANG
Medical Journal of Peking Union Medical College Hospital 2026;17(1):73-85
With the rapid advancement of hemodynamic indices and monitoring technologies, their classification methods and application processes have become increasingly complex. Currently, no unified standard hasbeen established, making it difficult to fully meet the clinical requirements for hemodynamic management. To assist in hemodynamic monitoring assessment and therapeutic decision-making in critically ill patients, the Critical Hemodynamic Therapy Collaborative Group, in conjunction with the Critical Ultrasound Study Group, has jointly developed the Standard for the Application of Hemodynamic Monitoring Techniques in Critical Care. The first part of this standard systematically categorizes hemodynamic indicators into flow indicators, pressure and its derivative indicators, and tissue perfusion indicators, while elaborating on the clinical application of each. The second part establishes a standardized clinical implementation pathway for hemodynamic monitoring. It proposes a tiered monitoring strategy-comprising basic, advanced, indication-specific, and special scenario monitoring-tailored to different clinical settings. It emphasizes the central role of critical care ultrasound across all levels of monitoring and establishes hemodynamic assessment standards for organs such as the brain, kidneys, and gastrointestinal tract. This standard aims to provide a unified framework for clinical practice, teaching, training, and research in critical care medicine, thereby promoting standardized development within the discipline.
2.Compilation Instruction and Key Point Interpretation for Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration
Wenzhe LI ; Rui MA ; Xiaoxiao ZHAO ; Hong HUA ; Xin CUI ; Yanming XIE ; Lianxin WANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):260-266
To develop the Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration in response to common problems, including insufficient safety information in package inserts, amplified medication risks in special populations, and non-standard clinical practices, thus establishing a risk management system tailored to the characteristics of Chinese patent medicines for mucosal administration. An approach combining qualitative and quantitative methods was adopted. In accordance with the Drug Administration Law of the People's Republic of China (2019 revision) and the GB/T 1.1—2020 standard, a systematic search was performed in the Chinese Pharmacopoeia (2020 edition), the Catalog of Medicines Covered by Medical Insurance (2022 edition), Chinese databases [China Network of Knowledge Infrastructure (CNKI), Wanfang Data (Wanfang), and VIP journal resource integration service platform (VIP)], and international databases (Cochrane Library, PubMed, and EMbase). Guideline outlines were developed through questionnaire surveys, expert interviews, and the nominal group technique. The content of each item was formulated with full consideration of traditional Chinese medicine (TCM) incompatibility, as well as the conceptual connotations and extensions of pharmacovigilance. The results included 54 Chinese patent medicines for mucosal administration from the Chinese Pharmacopoeia (2020 edition) and 58 from the Catalog of Medicines Covered by Medical Insurance (2022 edition). Safety-related items in the corresponding package inserts were collected, and 27 relevant publications were retrieved. Thirty experts from 24 institutions were mobilized for the drafting, and opinions from 61 external experts were solicited. A pharmacovigilance framework was established, covering the full chain of "monitoring, identification, assessment, and control". Based on seven anatomical sites, including nasal, ocular, and oral mucosa, a stratified monitoring system was constructed. The guideline proposed key recommendations on improving package insert sections such as "Adverse Reactions", "Contraindications", and "Precautions", clinical procedure standardization in healthcare institutions, risk control, and dynamic pharmacovigilance. The Guideline provides evidence-based support tailored to the risk profile of Chinese patent medicines for mucosal administration, filling the current gap in international pharmacovigilance standards in this field, while offering technical support for safety management across the full life cycle of medicines for mucosal administration.
3.Compilation Instruction and Key Point Interpretation for Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration
Wenzhe LI ; Rui MA ; Xiaoxiao ZHAO ; Hong HUA ; Xin CUI ; Yanming XIE ; Lianxin WANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):260-266
To develop the Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration in response to common problems, including insufficient safety information in package inserts, amplified medication risks in special populations, and non-standard clinical practices, thus establishing a risk management system tailored to the characteristics of Chinese patent medicines for mucosal administration. An approach combining qualitative and quantitative methods was adopted. In accordance with the Drug Administration Law of the People's Republic of China (2019 revision) and the GB/T 1.1—2020 standard, a systematic search was performed in the Chinese Pharmacopoeia (2020 edition), the Catalog of Medicines Covered by Medical Insurance (2022 edition), Chinese databases [China Network of Knowledge Infrastructure (CNKI), Wanfang Data (Wanfang), and VIP journal resource integration service platform (VIP)], and international databases (Cochrane Library, PubMed, and EMbase). Guideline outlines were developed through questionnaire surveys, expert interviews, and the nominal group technique. The content of each item was formulated with full consideration of traditional Chinese medicine (TCM) incompatibility, as well as the conceptual connotations and extensions of pharmacovigilance. The results included 54 Chinese patent medicines for mucosal administration from the Chinese Pharmacopoeia (2020 edition) and 58 from the Catalog of Medicines Covered by Medical Insurance (2022 edition). Safety-related items in the corresponding package inserts were collected, and 27 relevant publications were retrieved. Thirty experts from 24 institutions were mobilized for the drafting, and opinions from 61 external experts were solicited. A pharmacovigilance framework was established, covering the full chain of "monitoring, identification, assessment, and control". Based on seven anatomical sites, including nasal, ocular, and oral mucosa, a stratified monitoring system was constructed. The guideline proposed key recommendations on improving package insert sections such as "Adverse Reactions", "Contraindications", and "Precautions", clinical procedure standardization in healthcare institutions, risk control, and dynamic pharmacovigilance. The Guideline provides evidence-based support tailored to the risk profile of Chinese patent medicines for mucosal administration, filling the current gap in international pharmacovigilance standards in this field, while offering technical support for safety management across the full life cycle of medicines for mucosal administration.
4.Stress distribution on the maxilla when wearing the Twin-block appliance for Class Ⅱ malocclusion
Shuai LI ; Hua LIU ; Yonghui SHANG ; Yicong LIU ; Qihang ZHAO ; Wen LIU
Chinese Journal of Tissue Engineering Research 2025;29(5):881-887
BACKGROUND:The Twin-block orthodontic appliance is commonly used for the correction of Class Ⅱ malocclusion.Its mechanism of action in stimulating mandibular growth has been confirmed in many studies,but its impact on maxillary growth is not very clear. OBJECTIVE:By establishing a finite element model to analyze the stress distribution of the maxillary complex,surrounding bone sutures,and maxillary dentition in patients with Class Ⅱ malocclusion wearing Twin-block orthodontic appliances. METHODS:One patient with Class Ⅱ malocclusion who underwent orthodontic treatment at Qingdao Hospital/Qingdao Municipal Hospital of Shandong Rehabilitation University was selected.The bite force data of the patient when wearing the Twin-block orthodontic appliance was measured,and CBCT data were collected.A finite element model was established,including the maxillary complex,peripheral sutures,Twin-block orthodontic appliance,and maxillary dentition.ABAQUS software was used to simulate the stress distribution in the maxilla and maxillary dentition when the patient was wearing the Twin-block appliance. RESULTS AND CONCLUSION:The equivalent stress on the maxillary anterior teeth was significantly smaller than that on the posterior teeth,and the maximum equivalent stress on both sides of the teeth were 4.797 5 Mpa and 8.716 1 Mpa,respectively,which were located at the first premolar.The maximum displacements were presented at the maxillary incisors on both sides of the teeth,which were 0.080 5 mm and 0.081 0 mm,respectively.The maximum equivalent stress on the bone suture was 1.284 Mpa,which was mainly concentrated in the pterygopalatine suture and the frontal-maxillary suture on both sides,and there was almost no difference in the force of the rest of bone sutures;the maximum displacement of the bone suture was 0.07 mm,with the pterygopalatine suture having the largest displacement,followed by the frontal-maxillary suture.The maximal equivalent stress on the maxillary complex was 27.18 Mpa,which was mainly concentrated on both sides of the anterior pyriform foramen of the maxilla,around the nasofrontal suture and around the pterygopalatine suture at the posterior part of the jaws.The maximal displacement of the maxilla was 0.07 mm,which was mainly concentrated on the maxillary alveolar bone.All these findings show that the occlusal force acts on the maxillary complex through the Twin-block appliance,resulting in clockwise rotation of the maxilla and steepening of the dentition plane.Measures should be taken to compensate for this tendency,for example,by considering maxillary molar elongation and intrusion in the process of occlusion,which are not only able to flatten the occlusal plane,but facilitate the mandibular protraction,thereby further improving Class Ⅱ malocclusion orthodontic treatment.
5.Retrospective analysis of application value of percutaneous plate internal fixation after external fixation stenting in patients with open fracture of tibial shaft.
Peng-Fei CAI ; Wei ZHAO ; Jin-Hua WANG ; Ren-Sheng CHEN ; Xiao-Fei LI
China Journal of Orthopaedics and Traumatology 2025;38(3):273-279
OBJECTIVE:
To compare clinical effects of external fixation and minimally invasive percutaneous plate osteosynthesis (MIPPO) after external fixation in treating open fractures of tibial shaft.
METHODS:
From January 2020 to June 2022, 151 patients with open fracture of tibial shaft treated with external fixation stenting were divided into external fixation group and combined group according to different surgical methods. There were 81 patients in external fixation group, including 48 males and 33 females, aged from 21 to 68 years old with an average of (42.58±7.44) years old;according to Gustilo classification, 49 patients with typeⅡ, 32 patients with type ⅢA;the time from injury to treatment ranged from 2.5 to 10 h with an average of (4.25±0.74) h;external fixed stenting was performed. There were 70 patients in combined group, including 42 males and 28 females, aged from 20 to 69 years old with an average of (41.39±7.02) years old;35 patients with type Ⅱ and 35 patients with type ⅢA according to Gustilo classification;the time from injury to treatment ranged from 3 to 9 h with an average of (4.31±0.85) h;MIPPO treatment was performed after external fixed stenting. The time of callus formation, fracture healing and complications were compared between two groups. Rasmussen score and Hospital for Special Surgery (HSS) score were used to evaluate functional recovery of knee joint at 6 months after operation.
RESULTS:
Both groups were followed up for 6 to 13 months with an average of (10.17±2.33) months. The time of callus formation and fracture healing were (13.98±4.02) d and (70.26±12.15) d in combined group, and (18.56±4.37) d and (79.87±15.41) d in external fixation group, respectively. Combined group was better than external fixation group in the time of callus formation and fracture healing (P<0.05). At six months after operation, Rasmussen and HSS scores in combined group were (26.79±3.11) and (83.36±9.44), which were higher than those in external fixation group (24.51±4.63) and (79.63±8.46) (P<0.05). In external fixation group, there were 2 patients with incision infection, 2 patients with nail tract infection, 1 patient with stent loosening, fracture displacement, delayed union and malunion, and 1 patient with biocompatibility reaction in combined group, with statistical significance between two groups (P<0.05).
CONCLUSION
MIPPO could accelerate callus formation and fracture healing, improve knee function, improve clinical effects and reduce complications in patients with open tibial shaft fractures after external and external fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
Aged
;
Tibial Fractures/physiopathology*
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
;
Bone Plates
;
External Fixators
;
Fractures, Open/physiopathology*
;
Stents
;
Young Adult
6.Comparison of outcomes between enhanced workflows and express workflows in robotic-arm assisted total hip arthroplasty.
Xiang ZHAO ; Xiang-Hua WANG ; Rong-Xin HE ; Xun-Zi CAI ; Li-Dong WU ; Hao-Bo WU ; Shi-Gui YAN
China Journal of Orthopaedics and Traumatology 2025;38(10):987-993
OBJECTIVE:
To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA).
METHODS:
A retrospective analysis was conducted on 46 patients who underwent robotic-assisted THA between November 2020 and May 2021. They were divided into the enhanced workflows group and the express workflows group based on the surgical methods. There were 20 patients in the enhanced workflows group, including 11 males and 9 females;aged from 51 to 78 years old with an average of (67.30±7.52) years old. The BMI ranged from 18.24 to 24.03 kg·m-2 with an average of(23.80±3.01) kg·m-2. There were 26 patients in the express workflows group, including 12 males and 14 females;aged from 57 to 84 years old with a mean age of (67.58±7.29) years old, and their BMI ranged from 19.72 to 30.08 kg·m-2 with an average of (24.41 ±2.92) kg·m-2. The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded.
RESULTS:
All patients completed the surgery as planned and were followed up, with the follow-up period ranging from 47 to 54 months with a mean of (49.78±1.85) months and the length of hospital stay ranging from 2 to 11 days with an average of (6.57±1.82 ) days. The operation time of enhanced workflows group was (93.41±16.41) minutes, which was longer than that of the express workflow groups (75.19±18.36) minutes, and the difference was statistically significant (P<0.05). In enhanced workflows group, the postoperative acetabular anteversion angle was (19.20±4.46)°, the limb length discrepancy was (-1.55±9.13) mm, and changes of the offset was (-5.15±6.77) mm. The corresponding values in express workflows group were (20.46±3.29)°, (2.19±4.39) mm, and (-2.39±4.34) mm, respectively. There was no statistically significant difference in these indicators between the two groups(P>0.05). One patient in the enhanced workflows group developed deep venous thrombosis after surgery. No cases of dislocation or periprosthetic infection. At the latest follow-up, all patients had well-positioned prostheses without loosening. Harris hip score was (90.50±1.67) points in enhanced workflows group and (90.73±2.36) points in the express workflows group, with no statistically significant difference between the two groups (P>0.05).
CONCLUSION
The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Aged, 80 and over
;
Workflow
;
Treatment Outcome
7.Clinical effects of single Kirschner wire assisted reduction in children with Gartland type Ⅲ supracondylar humerus fractures.
Yong HE ; Wei-Ping LI ; Zhi-Long CHEN ; Guo-Peng JIANG ; Shi-Hai CHEN ; Jun ZHAO ; Hua-Ming WANG ; Chen ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1071-1075
OBJECTIVE:
To investigate the clinical efficacy and safety of single Kirschner wire assisted poking and closed reduction in the treatment of Gartland type Ⅲ supracondylar humeral fractures in children.
METHODS:
A retrospective analysis was performed on patients diagnosed with Gravland type Ⅲ supracondylar humeral fractures between January 2022 and June 2023. A total of 46 patients were treated with closed reduction assisted by Kirschner wires and percutaneous Kirschner wire internal fixation.There were 25 males and 21 females. The age ranged from 5 to 10 years old, with an average of (5.8±1.8) years old. The left side was involved in 28 patients and the right side in 18 patients. Record the operative duration for patients, the number of fluoroscopic exposures, fracture healing time, postoperative carrying angle, Baumann angle, elbow joint function score at three months post-operation, and any associated complications.
RESULTS:
All 46 patients were followed up for a period of 12 to 16 weeks, with an average of (13.74±1.44 )weeks. The operation duration was (30.7±5.1) minutes, the fluoroscopy count was (10.2±2.7) times, the postoperative carrying angle of the elbow joint was (8.7±2.2) degrees, and the Baumann angle was (71.5±2.9) degrees. All fractures achieved successful union in all patients, with a mean healing time of (25.5±1.7) days.At the final follow-up, elbow joint function was assessed using the Flynn criteria, with 43 patients rated as excellent and 3 patients rated as good. No complications were observed, including cubitus varus, nerve injury, or local infection.
CONCLUSION
The use of a single Kirschner wire assisted prying reduction for treating Gartland type Ⅲ supracondylar humeral fractures in children demonstrates excellent clinical efficacy and safety.
Humans
;
Male
;
Female
;
Child
;
Bone Wires
;
Child, Preschool
;
Humeral Fractures/physiopathology*
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Treatment Outcome
;
Fracture Healing
8.YOLOX-SwinT algorithm improves the accuracy of AO/OTA classification of intertrochanteric fractures by orthopedic trauma surgeons.
Xue-Si LIU ; Rui NIE ; Ao-Wen DUAN ; Li YANG ; Xiang LI ; Le-Tian ZHANG ; Guang-Kuo GUO ; Qing-Shan GUO ; Dong-Chu ZHAO ; Yang LI ; He-Hua ZHANG
Chinese Journal of Traumatology 2025;28(1):69-75
PURPOSE:
Intertrochanteric fracture (ITF) classification is crucial for surgical decision-making. However, orthopedic trauma surgeons have shown lower accuracy in ITF classification than expected. The objective of this study was to utilize an artificial intelligence (AI) method to improve the accuracy of ITF classification.
METHODS:
We trained a network called YOLOX-SwinT, which is based on the You Only Look Once X (YOLOX) object detection network with Swin Transformer (SwinT) as the backbone architecture, using 762 radiographic ITF examinations as the training set. Subsequently, we recruited 5 senior orthopedic trauma surgeons (SOTS) and 5 junior orthopedic trauma surgeons (JOTS) to classify the 85 original images in the test set, as well as the images with the prediction results of the network model in sequence. Statistical analysis was performed using the SPSS 20.0 (IBM Corp., Armonk, NY, USA) to compare the differences among the SOTS, JOTS, SOTS + AI, JOTS + AI, SOTS + JOTS, and SOTS + JOTS + AI groups. All images were classified according to the AO/OTA 2018 classification system by 2 experienced trauma surgeons and verified by another expert in this field. Based on the actual clinical needs, after discussion, we integrated 8 subgroups into 5 new subgroups, and the dataset was divided into training, validation, and test sets by the ratio of 8:1:1.
RESULTS:
The mean average precision at the intersection over union (IoU) of 0.5 (mAP50) for subgroup detection reached 90.29%. The classification accuracy values of SOTS, JOTS, SOTS + AI, and JOTS + AI groups were 56.24% ± 4.02%, 35.29% ± 18.07%, 79.53% ± 7.14%, and 71.53% ± 5.22%, respectively. The paired t-test results showed that the difference between the SOTS and SOTS + AI groups was statistically significant, as well as the difference between the JOTS and JOTS + AI groups, and the SOTS + JOTS and SOTS + JOTS + AI groups. Moreover, the difference between the SOTS + JOTS and SOTS + JOTS + AI groups in each subgroup was statistically significant, with all p < 0.05. The independent samples t-test results showed that the difference between the SOTS and JOTS groups was statistically significant, while the difference between the SOTS + AI and JOTS + AI groups was not statistically significant. With the assistance of AI, the subgroup classification accuracy of both SOTS and JOTS was significantly improved, and JOTS achieved the same level as SOTS.
CONCLUSION
In conclusion, the YOLOX-SwinT network algorithm enhances the accuracy of AO/OTA subgroups classification of ITF by orthopedic trauma surgeons.
Humans
;
Hip Fractures/diagnostic imaging*
;
Orthopedic Surgeons
;
Algorithms
;
Artificial Intelligence
9.Single-incision laparoscopic totally extraperitoneal retrieval of retroperitoneal vas deferens in vasovasostomy for obstructive azoospermia patients postchildhood bilateral herniorrhaphy.
Chen-Wang ZHANG ; Wei-Dong WU ; Jun-Wei XU ; Jing-Peng ZHAO ; Er-Lei ZHI ; Yu-Hua HUANG ; Chen-Cheng YAO ; Fu-Jun ZHAO ; Zheng LI ; Peng LI
Asian Journal of Andrology 2025;27(1):137-138
10.Association of redundant foreskin with sexual dysfunction: a cross-sectional study from 5700 participants.
Yuan-Qi ZHAO ; Nian LI ; Xiao-Hua JIANG ; Yang-Yang WAN ; Bo XU ; Xue-Chun HU ; Yi-Fu HOU ; Ji-Yan LI ; Shun BAI
Asian Journal of Andrology 2025;27(1):90-95
A previous study showed that the length of the foreskin plays a role in the risk of sexually transmitted infections and chronic prostatitis, which can lead to poor quality of sexual life. Here, the association between foreskin length and sexual dysfunction was evaluated. A total of 5700 participants were recruited from the andrology clinic at The First Affiliated Hospital of University of Science and Technology of China (Hefei, China). Clinical characteristics, including foreskin length, were collected, and sexual function was assessed by the International Index of Erectile Function-5 (IIEF-5) and Premature Ejaculation Diagnostic Tool (PEDT) questionnaires. Men with sexual dysfunction were more likely to have redundant foreskin than men without sexual dysfunction. Among the 2721 erectile dysfunction (ED) patients and 1064 premature ejaculation (PE) patients, 301 (11.1%) ED patients and 135 (12.7%) PE patients had redundant foreskin, respectively. Men in the PE group were more likely to have redundant foreskin than men in the non-PE group ( P = 0.004). Logistic regression analyses revealed that the presence of redundant foreskin was associated with increased odds of moderate/severe ED (adjusted odds ratio [aOR] = 1.31, adjusted P = 0.04), moderate PE (aOR = 1.38, adjusted P = 0.02), and probable PE (aOR = 1.37, adjusted P = 0.03) after adjusting for confounding variables. Our study revealed a positive correlation between the presence of redundant foreskin and the risk of sexual dysfunction, especially in PE patients. Assessment of the length of the foreskin during routine clinical diagnosis may provide information for patients with sexual dysfunction.
Humans
;
Male
;
Foreskin
;
Cross-Sectional Studies
;
Adult
;
Erectile Dysfunction/epidemiology*
;
Premature Ejaculation/epidemiology*
;
Middle Aged
;
China/epidemiology*
;
Surveys and Questionnaires
;
Sexual Dysfunction, Physiological/epidemiology*
;
Young Adult

Result Analysis
Print
Save