1.Determination of Dilauryl Thiodipropionate in Fried Foods by Reverse Phase Liquid Chromatography-Tandem Mass Spectrometry
Jin-Can SHEN ; Yao LUO ; Feng-Qi WU ; Bei-Bei XIONG ; Zhang-Jie WU ; Ya-Mei LI ; Jun-Fa ZENG ; Chang-Xiong HUANG
Chinese Journal of Analytical Chemistry 2025;53(11):1860-1869
A method was developed for determination of dilauryl thiodipropionate(DLTDP)in fried foods by coupling solid-phase extraction(SPE)pretreatment with reverse-phase liquid chromatography-tandem mass spectrometry(RPLC-MS/MS)detection.Samples were extracted with n-hexane as the solvent,purified using a neutral alumina SPE cartridge,and finally analyzed by RPLC-MS/MS.Quantitative analysis was performed using matrix-matched calibration curves combined with an external standard method under optimal experimental conditions.The results showed that DLTDP exhibited good linearity in the range of 2.0-50.0 μg/L,with a correlation coefficient(R2)≥0.999.The limit of detection(LOD)and the limit of quantification(LOQ)of the method were 0.15 mg/kg and 0.5 mg/kg,respectively.The mean recoveries at three fortification levels(0.5,1.0,and 200 mg/kg)in different samples ranged from 84.8%to 96.8%,with the relative standard deviations(RSDs)all less than 8.0%.The developed method was highly sensitive,accurate and reliable,and easy to operate,making it well suited for the routine quantitative analysis of DLTDP in fried foods.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Exploring the feasibility of endoscopic surgery by gastrointestinal surgeons: surgeon′s perspective
Jun LUO ; Bei LI ; Ying YU ; Tingting HUANG ; Lan CHEN ; Meiwen HE ; Shaowei XIONG ; Mingxuan ZHU ; Zhanlong SHEN ; Guoqing LYU
Chinese Journal of Digestive Surgery 2024;23(8):1123-1126
Due to traditional professional divisions, the practice of endoscopy by gastro-intestinal surgeons in China remains controversial. However, with the evolution of treatment philo-sophies, medical technology, and equipment advancements, a trend of integration between tradi-tional surgery and endoscopy is emerging. Gastrointestinal surgeons performing endoscopy can maxi-mize patient benefits, and they naturally possess advantages in conducting endoscopic procedures. It is recommended to further establish entry thresholds for surgeons to perform endoscopy, provide standardized endoscopic training for surgeons, and coordinate efforts at the administrative depart-ment. With the support of artificial intelligence, more patients can receive minimally invasive, indivi-dualized, and precise treatments.
8.Artificial intelligence models based on non-contrast chest CT for measuring bone mineral density
Wei DUAN ; Guoqing YANG ; Yang LI ; Feng SHI ; Lian YANG ; Xin XIONG ; Bei CHEN ; Yong LI ; Quanshui FU
Chinese Journal of Medical Imaging Technology 2024;40(8):1231-1235
Objective To observe the value of artificial intelligence(AI)models based on non-contrast chest CT for measuring bone mineral density(BMD).Methods Totally 380 subjects who underwent both non-contrast chest CT and quantitative CT(QCT)BMD examination were retrospectively enrolled and divided into training set(n=304)and test set(n=76)at a ratio of 8∶2.The mean BMD of L1-L3 vertebrae were measured based on QCT.Spongy bones of T5-T10 vertebrae were segmented as RO1,radiomics(Rad)features were extracted,and machine learning(ML),Rad and deep learning(DL)models were constructed for classification of osteoporosis(OP)and evaluating BMD,respectively.Receiver operating characteristic curves were drawn,and area under the curves(AUC)were calculated to evaluate the efficacy of each model for classification of OP.Bland-Altman analysis and Pearson correlation analysis were performed to explore the consistency and correlation of each model with QCT for measuring BMD.Results Among ML and Rad models,MLBagging OP and RadBagging-OP had the best performances for classification of OP.In test set,AUC of MLBagging-OP,RadBagging-op and DLOP for classification of OP was 0.943,0.944 and 0.947,respectively,with no significant difference(all P>0.05).BMD obtained with all the above models had good consistency with those measured with QCT(most of the differences were within the range of(x)±1.96s),which were highly positively correlated(r=0.910-0.974,all P<0.001).Conclusion AI models based on non-contrast chest CT had high efficacy for classification of OP,and good consistency of BMD measurements were found between AI models and QCT.
9.Research on the impact of supply side policy coordination of medical insurance on cost control under DIP payment method
Kun-He LIN ; Ye-Sheng SHANGGUAN ; Ya-Qi RAO ; Jing PENG ; Yi CHEN ; Yi-Fan YAO ; Ying-Bei XIONG ; Li XIANG
Chinese Journal of Health Policy 2024;17(5):17-24
Objective:This study aims to explore the synergistic effects of DIP and other medical insurance supply-side policies.Method:City A that has piloted DIP reform was set as the treatment group,and City B without reform was set as the control group.A total of 1 120 public medical institution samples from 2019 to 2022 were collected.The total medical expenses during hospitalization and some structural expenses were analyzed using DID method.Result:DIP had a significant inhibitory effect on the medical expenses,and the expenses of checkups and examinations during hospitalization in city A,but had no impact on the drug and the material expenses during hospitalization.Conclusion:DIP played a significant cost control role and effectively controlled the total medical expenses during hospitalization.The synergistic effects of price adjustment of medical services policy and national centralized drug/material procurement policy on cost control were insufficient.DIP synergized with other supply-side policies to promote rational medical cost structure.It is suggested that medical insurance departments should focus on the synergistic effects of medical insurance supply-side policies to jointly improve the efficiency of medical insurance fund utilization.
10.Analysis of medical reimbursement rate and influencing factors under the DIP payment method
Meng-Yuan ZHAO ; Kun-He LIN ; Ying-Bei XIONG ; Yi-Fan YAO ; Zhi-He CHEN ; Yu-Meng ZHANG ; Li XIANG
Chinese Journal of Health Policy 2024;17(6):40-46
Objective:Analyze the medical reimbursement rate and influencing factors under the DIP payment method to refine the DIP payment policy,promote the optimization of internal operations in medical institutions,and ensure reasonable compensation.Methods:Based on the 2022 DIP fund settlement data from 196 medical institutions in City A,the study used multiple linear regression to analyze the factors affecting medical reimbursement rate and conducted a heterogeneity analysis for medical institutions of different levels.Results:The medical reimbursement rate for medical institutions in City A in 2022 was 103.32%.Medical institutions with lower CMI standardized inpatient costs,lower rates of deviation cases,tertiary care institutions,lower proportion of level-four surgeries,and lower ratios of resident to employee medical insurance cases have higher medical reimbursement rate(P<0.05).Heterogeneity analysis reveals that therates of deviation cases,the proportion of primary care diseases,the ratio of resident to employee medical insurance cases,and the low-standard admission rate have different impacts on medical institutions of different levels.Conclusion:Medical insurance departments should improve policies for primary care diseases,dynamically adjust disease catalogs and payment standards,optimize funding levels and institutional coefficients,and increase penalties for violations to ensure effective use of funds.Medical institutions need to strengthen their understanding of policies,focus on refined internal management,promote standardized and rational diagnosis and treatment through performance assessment transformation,and leverage their own advantages in medical services to reasonably increase the medical reimbursement rate.

Result Analysis
Print
Save
E-mail