1.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
2.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
3.Dual-Center Clinical Study on Detection of Intraoperative Air Leak During Pulmonary Resection Using Nebulized Indocyanine Green
Zhenfan WANG ; Songjing ZHAO ; Ruiheng JIANG ; Zhuoer CUI ; Yingtai CHEN ; Jian ZHOU ; Kezhong CHEN ; Yun LI
Medical Journal of Peking Union Medical College Hospital 2026;17(3):646-651
To evaluate the clinical value of nebulized indocyanine green(ICG) combined with near-infrared fluorescence imaging for intraoperative detection of air leaks during pulmonary resection. This was a two-center randomized controlled trial enrolling patients undergoing thoracoscopic pulmonary resection. After enrollment, patients were randomly divided into an experimental group and a control group. The experimental group received nebulized ICG and fluorescence imaging in addition to the conventional water immersion test, while the control group underwent the water immersion test alone. Intraoperative air leak detection and postoperative air leak incidence were compared between the two groups. Multivariable logistic regression analysis was performed to assess the association between ICG nebulization intervention and postoperative air leaks after adjusting for confounding factors including age, sex, smoking history, history of respiratory disease, surgical procedure, and study center. A total of 181 patients were enrolled(90 in the experimental group, 91 in the control group). The experimental group showed significantly higher intraoperative air leak detection rate(37.8% Nebulized ICG combined with near-infrared fluorescence imaging significantly improves intraoperative detection of air leaks, reduces the incidence of postoperative air leaks, and shortens chest tube duration. This technique is convenient, safe, and holds important clinical value for application.
4.Application of Recombinant Collagen in Biomedicine
Huan HU ; Hong ZHANG ; Jian WANG ; Li-Wen WANG ; Qian LIU ; Ning-Wen CHENG ; Xin-Yue ZHANG ; Yun-Lan LI
Progress in Biochemistry and Biophysics 2025;52(2):395-416
Collagen is a major structural protein in the matrix of animal cells and the most widely distributed and abundant functional protein in mammals. Collagen’s good biocompatibility, biodegradability and biological activity make it a very valuable biomaterial. According to the source of collagen, it can be broadly categorized into two types: one is animal collagen; the other is recombinant collagen. Animal collagen is mainly extracted and purified from animal connective tissues by chemical methods, such as acid, alkali and enzyme methods, etc. Recombinant collagen refers to collagen produced by gene splicing technology, where the amino acid sequence is first designed and improved according to one’s own needs, and the gene sequence of improved recombinant collagen is highly consistent with that of human beings, and then the designed gene sequence is cloned into the appropriate vector, and then transferred to the appropriate expression vector. The designed gene sequence is cloned into a suitable vector, and then transferred to a suitable expression system for full expression, and finally the target protein is obtained by extraction and purification technology. Recombinant collagen has excellent histocompatibility and water solubility, can be directly absorbed by the human body and participate in the construction of collagen, remodeling of the extracellular matrix, cell growth, wound healing and site filling, etc., which has demonstrated significant effects, and has become the focus of the development of modern biomedical materials. This paper firstly elaborates the structure, type, and tissue distribution of human collagen, as well as the associated genetic diseases of different types of collagen, then introduces the specific process of producing animal source collagen and recombinant collagen, explains the advantages of recombinant collagen production method, and then introduces the various systems of expressing recombinant collagen, as well as their advantages and disadvantages, and finally briefly introduces the application of animal collagen, focusing on the use of animal collagen in the development of biopharmaceutical materials. In terms of application, it focuses on the use of animal disease models exploring the application effects of recombinant collagen in wound hemostasis, wound repair, corneal therapy, female pelvic floor dysfunction (FPFD), vaginal atrophy (VA) and vaginal dryness, thin endometritis (TE), chronic endometritis (CE), bone tissue regeneration in vivo, cardiovascular diseases, breast cancer (BC) and anti-aging. The mechanism of action of recombinant collagen in the treatment of FPFD and CE was introduced, and the clinical application and curative effect of recombinant collagen in skin burn, skin wound, dermatitis, acne and menopausal urogenital syndrome (GSM) were summarized. From the exploratory studies and clinical applications, it is evident that recombinant collagen has demonstrated surprising effects in the treatment of all types of diseases, such as reducing inflammation, promoting cell proliferation, migration and adhesion, increasing collagen deposition, and remodeling the extracellular matrix. At the end of the review, the challenges faced by recombinant collagen are summarized: to develop new recombinant collagen types and dosage forms, to explore the mechanism of action of recombinant collagen, and to provide an outlook for the future development and application of recombinant collagen.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
8.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
10.Lumbar Spondylolysis in Chinese Adults: Prevalence and Musculoskeletal Conditions.
Dong YAN ; Yan Dong LIU ; Ling WANG ; Kai LI ; Wen Shuang ZHANG ; Yi YUAN ; Jian GENG ; Kang Kang MA ; Feng Yun ZHOU ; Zi Tong CHENG ; Xiao Guang CHENG
Biomedical and Environmental Sciences 2025;38(5):598-606
OBJECTIVE:
To determine the prevalence of lumbar spondylolysis (LS) and the proportion of spondylolytic spondylolisthesis (SS) in China, and to evaluate the musculoskeletal status of patients with LS and SS.
METHODS:
Spine Computed Tomography (CT) images were collected from community populations aged 40 and above in a nationwide multi-center project. LS was diagnosed, and SS was graded by an experienced radiologist. Bone mineral density (BMD) and paraspinal muscle parameters were quantified based on CT images.
RESULTS:
One hundred and seventeen patients of a total of 3,317 individuals were diagnosed with LS, corresponding to a prevalence rate of 3.53%. 63 of the 1,214 males (5.18%) and 54 of the 2,103 females (2.57%) were diagnosed with LS. SS occurred in 64/121 vertebrae (52.89%). BMD was not associated with LS ( P = 0.341). The L5 extensor paraspinal muscle density was higher in the LS group than in the non-LS group. In the LS group, patients with SS had a smaller L5 paraspinal extensor muscle cross-sectional area than those without SS ( P = 0.003).
CONCLUSION
The prevalence of LS in Chinese adults was 3.53%, with prevalence rates of 5.18% in males and 2.57% in females. Patients with LS have higher muscle density, whereas those with SS have smaller muscle cross-sectional areas at the L5 level.
Humans
;
Male
;
Female
;
Middle Aged
;
China/epidemiology*
;
Prevalence
;
Adult
;
Lumbar Vertebrae/diagnostic imaging*
;
Spondylolysis/diagnostic imaging*
;
Aged
;
Bone Density
;
Tomography, X-Ray Computed
;
Aged, 80 and over
;
Spondylolisthesis/epidemiology*
;
East Asian People

Result Analysis
Print
Save
E-mail