1.Analysis of components migrating to blood and metabolites of Polygonum cuspidatum in rats with acute gouty arthritis
Caiyi KE ; Meng SHEN ; Li JI ; Xuechun WANG ; Yuqing ZHU ; Xi CHEN ; Chengweiqi WANG ; Qun MA
China Pharmacy 2025;36(13):1581-1586
OBJECTIVE To analyze the components migrating to blood and metabolites of Polygonum cuspidatum in rats with acute gouty arthritis (AGA). METHODS SD rats were randomly divided into blank group, model group and P. cuspidatum group (10 g/kg, by raw material), with 6 rats in each group. Except for blank group, AGA model was induced in the remaining groups by injecting potassium oxonate and sodium urate; meanwhile, they were administered corresponding drug solutions or water intragastrically, once a day, for 10 consecutive days. The histopathological morphology of the knee joint tissues in rats was observed;rat serum samples were collected, and the components migrating to blood and metabolites of P. cuspidatum were analyzed by using UPLC-Q-Exactive-Orbitrap-MS. RESULTS Following the intervention with P. cuspidatum, the histopathological morphology of the knee joint synovial tissue in AGA rats showed significant improvement, with reduced inflammatory cell infiltration and hyperplasia, and the preservation of the honeycomb-like structure integrity. In both positive and negative ion modes, a total of 67 chemical components were detected in the serum of rats from P. cuspidatum group, including 25 prototype components and 42 metabolites. The involved compound types encompassed stilbenes, anthraquinones, naphthols, and flavonoids, among others. The metabolic reactions identified included methylation, acetylation, sulfation, and glucuronidation. Notably, compounds such as polydatin, resveratrol and emodin were capable of entering the bloodstream in their prototype forms and undergoing in vivo metabolism. CONCLUSIONS Compounds such as polydatin, resveratrol and emodin are likely to be the active components responsible for the anti-AGA effects of P. cuspidatum.
2.CFAP300 loss-of-function variant causes primary ciliary dyskinesia and male infertility via disrupting sperm flagellar assembly and acrosome formation.
Hua-Yan YIN ; Yu-Qi ZHOU ; Qun-Shan SHEN ; Zi-Wen CHEN ; Jie-Ru LI ; Huan WU ; Yun-Xia CAO ; Rui GUO ; Bing SONG
Asian Journal of Andrology 2025;27(6):743-750
Primary ciliary dyskinesia (PCD) is a genetically heterogeneous disorder characterized by impaired motility of cilia and flagella. Mutations in cilia- and flagella-associated protein 300 ( CFAP300 ) are associated with human PCD and male infertility; however, the underlying pathogenic mechanisms remain poorly understood. In a consanguineous Chinese family, we identified a homozygous CFAP300 loss-of-function variant (c.304delC) in a proband presenting with classical PCD symptoms and severe sperm abnormalities, including dynein arm deficiency and acrosomal malformation, as confirmed by transmission electron microscopy (TEM). Histological analysis revealed multiple morphological abnormalities of the sperm flagella in CFAP300 -mutant individual, whereas immunofluorescence demonstrated markedly reduced CFAP300 expression in the spermatozoa of the proband. Furthermore, tandem mass tag (TMT)-based quantitative proteomics showed that the CFAP300 mutation reduced key spermatogenesis proteins (e.g., sperm flagellar 2 [SPEF2], solute carrier family 25 member 31 [SLC25A31], and A-kinase anchoring protein 3 [AKAP3]) and mitochondrial ATP synthesis factors (e.g., SLC25A31, cation channel sperm-associated 3 [CATSPER3]). It also triggered abnormal increases in autophagy-related proteins and signaling mediator phosphorylation. These molecular alterations are likely to contribute to progressive deterioration of sperm ultrastructure and function. Notably, successful pregnancy was achieved via intracytoplasmic sperm injection (ICSI) using the proband's sperm. Overall, this study expands the known CFAP300 mutational spectrum and offers novel mechanistic insights into its role in spermatogenesis.
Humans
;
Male
;
Infertility, Male/pathology*
;
Acrosome/pathology*
;
Sperm Tail/pathology*
;
Pedigree
;
Spermatozoa
;
Adult
;
Loss of Function Mutation
;
Ciliary Motility Disorders/genetics*
;
Spermatogenesis/genetics*
;
Female
3.The systemic inflammatory response index as a risk factor for all-cause and cardiovascular mortality among individuals with coronary artery disease: evidence from the cohort study of NHANES 1999-2018.
Dao-Shen LIU ; Dan LIU ; Hai-Xu SONG ; Jing LI ; Miao-Han QIU ; Chao-Qun MA ; Xue-Fei MU ; Shang-Xun ZHOU ; Yi-Xuan DUAN ; Yu-Ying LI ; Yi LI ; Ya-Ling HAN
Journal of Geriatric Cardiology 2025;22(7):668-677
BACKGROUND:
The association of systemic inflammatory response index (SIRI) with prognosis of coronary artery disease (CAD) patients has never been investigated in a large sample with long-term follow-up. This study aimed to explore the association of SIRI with all-cause and cause-specific mortality in a nationally representative sample of CAD patients from United States.
METHODS:
A total of 3386 participants with CAD from the National Health and Nutrition Examination Survey (NHANES) 1999-2018 were included in this study. Cox proportional hazards model, restricted cubic spline (RCS), and receiver operating characteristic curve (ROC) were performed to investigate the association of SIRI with all-cause and cause-specific mortality. Piece-wise linear regression and sensitivity analyses were also performed.
RESULTS:
During a median follow-up of 7.7 years, 1454 all-cause mortality occurred. After adjusting for confounding factors, higher lnSIRI was significantly associated with higher risk of all-cause (HR = 1.16, 95% CI: 1.09-1.23) and CVD mortality (HR = 1.17, 95% CI: 1.05-1.30) but not cancer mortality (HR = 1.17, 95% CI: 0.99-1.38). The associations of SIRI with all-cause and CVD mortality were detected as J-shaped with threshold values of 1.05935 and 1.122946 for SIRI, respectively. ROC curves showed that lnSIRI had robust predictive effect both in short and long terms.
CONCLUSIONS
SIRI was independently associated with all-cause and CVD mortality, and the dose-response relationship was J-shaped. SIRI might serve as a valid predictor for all-cause and CVD mortality both in the short and long terms.
4.Progress in Epidemiological Research on Relationship Between Duration of Type 2 Diabetes and Risk of Malignant Tumors of Female Reproductive System
Xiaohui ZHOU ; Zhuoying LI ; Wanwan LIU ; Peiwen LU ; Qiuming SHEN ; Qun XU ; Yongbing XIANG
Cancer Research on Prevention and Treatment 2024;51(12):977-988
The relationship between the duration of type 2 diabetes mellitus (T2DM) and the risk of female reproductive malignancies is complex and multifaceted. Large population cohort studies revealed a negative association between the duration of T2DM and the incidence of breast cancer and endometrial cancer. Furthermore, the risk of breast and endometrial cancer is the highest within a short time after T2DM diagnosis and remains remarkably higher in patients with longer diabetes duration than in the nondiabetic population. This phenomenon suggests causal reverse bias and potential detection bias. Nevertheless, T2DM remains an important risk factor for breast and
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Investigation of coordinated development between blood banks and apheresis plasma collection banks
Qun LIU ; Dunzhu GONGJUE ; Qian ZHANG ; Hui YE ; Hua SHEN ; Mingming QIAO ; Linwei LI ; Xingzhe ZHANG ; Xiangwen CHEN ; Liliang CHEN ; Yang LIU ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(8):927-932
Objective To explore the factors that affect the coordinated development of blood banks and apheresis plas-ma collection banks(hereinafter referred to as plasma banks),and explore feasible measures for the coordinated develop-ment of blood banks and plasma banks.Methods The blood information management system and blood source information management system were used to retrieve related data of blood and plasma donation from 9 cities in Shandong province from 2017 to 2021.The number of blood donors and plasma donors and the intersection of them were analyzed.The data analysis was performed using chi-square test,and a questionnaire survey was conducted to investigate the policies and information status,as well as expectations for coordinated development for blood and plasma donation.Results From 2017 to 2021,the total number of blood donors in 9 cities was higher than that of plasma donors,both have been increasing year by year,and the increase in plasma donors was significantly higher than that of blood donors(131.78%vs 23.90%,P<0.05).The inter-section proportion of blood and plasma donors had increased from 0.45%in 2017 to 1.04%in 2021,with an increase of 131.11%.Among the administrative regions where the participating blood and plasma banks located,94.2%have not re-leased relevant policy to promote the coordinated development of blood and plasma donation.The majority(63%)expected blood banks and plasma banks to be set at a distance more than 50 km apart.The top four functional requirements for the in-terconnection between blood banks and plasma banks management information system were blood test results(94.61%),ID number(87.54%),blood and plasma donation records(85.51%)and health consultation/examination results(82.15%).The top four elements of coordinated development between blood and plasma banks were policy support(96.25%),informa-tion networking(92.36%),top-level design(87.44%)and cultural construction(86.58%).Conclusion The number of donors who donate both blood(mainly whole blood)and plasma has been increasing year by year,which deserves our close attention.To achieve the coordinated development of blood donation and plasma donation,policy support is the most crucial and fundamental means.Establishment of a standard system and the share of blood and plasma donation information is neces-sary for blood informatization construction.It was critical to promote the coordinated development of blood and plasma dona-tion and ensure blood safety with improving legislation,formulating policies for coordinated development,strengthening top-level design,standardizing the publicity of blood and plasma donation and establishing the idea that blood and plasma dona-tion are equally honorable.
10.Long-Term Survival Trend of Gynecological Cancer:A Systematic Review of Population-Based Cancer Registration Data
Zhou XIAOHUI ; Yang DANNI ; Zou YIXIN ; Tang DANDAN ; Chen JUN ; Li ZHUOYING ; Shen QIUMING ; Xu QUN ; Xiang YONGBING
Biomedical and Environmental Sciences 2024;37(8):897-921
Gynecological cancer significantly affect the health of women.This review aimed to describe the global patterns and trends in the survival of patients with gynecological cancers.We searched PubMed,Embase,Web of Science,SinoMed,and SEER for survival analyses of cancer registration data of cervical,endometrial,and ovarian cancers published between 1980 and 2022.Globally,the highest 5-year observed survival rate for cervical cancer was 76.5%in Anshan,Liaoning,China(2008-2017).The 5-year observed survival rates of endometrial and ovarian cancers were higher in Finland(1995-1999,82.5%)and Singapore(1988-1992,62.0%).The 5-year relative survival rate of cervical cancer patients was higher in Haining,Zhejiang,China(2011-2014,85.8%).Korea ranked first at 89.0%and 64.5%for endometrial and ovarian cancers,respectively.Survival rates have improved for cervical,endometrial,and ovarian cancers.Patients aged≥75 years and those with advanced-stage disease had the worst 5-year survival rates.Survival rates were better for squamous cell carcinoma in cervical cancer,for endometrial carcinoma and mucinous adenocarcinoma in endometrial cancer,and for germ cell and sex-cord stromal tumors in ovarian cancer.Over the past four decades,the survival rates of gynecological cancers have increased globally,with notable increases in cervical and endometrial cancers.Survival rates are higher in developed countries,with a slow-growing trend.Future studies should focus on improving survival,especially in ovarian cancer patients.

Result Analysis
Print
Save
E-mail