1.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
2.Effects of resistance training on quadriceps mass and knee joint function in patients with osteoporosis and sarcopenia
Jian ZHOU ; Tao ZHANG ; Weili ZHOU ; Xingcheng ZHAO ; Jun WANG ; Jie SHEN ; Li QIAN ; Ming LU
Chinese Journal of Tissue Engineering Research 2026;30(5):1081-1088
BACKGROUND:The quadriceps strength of patients with osteoporosis and sarcopenia is significantly reduced,which can further reduce the function of the knee joint,affect the function of the lower limbs and even lead to a decrease in whole-body coordination.It is speculated that a reasonable quadriceps training program and personalized guidance are beneficial to the recovery of knee joint function in patients with osteoporosis and sarcopenia.OBJECTIVE:To observe the effect of short-term moderate-intensity resistance rehabilitation training on the mass and function of the quadriceps and knee joint function in patients with osteoporosis and sarcopenia.METHODS:Using the integrated physical examination and rehabilitation model,375 patients with osteoporosis and sarcopenia were screened at the Health Management Center of Shanghai Public Health Clinical Center.They underwent 12 weeks of combined/comprehensive exercise rehabilitation based on resistance exercise,including quadriceps resistance isotonic and isometric contraction training twice a week(3-5 sets each time,10-15 minutes per set)and aerobic exercise/balance exercise two or three times a week(30 minutes each time).Assessments and data collection were performed before rehabilitation training,12 weeks after rehabilitation training,and at follow-up 12 weeks after stopping rehabilitation training,mainly including knee joint range of motion and proprioception,quadriceps muscle strength,and cross-sectional area(magnetic resonance imaging results),pain,knee joint function(Hospital for Special Surgery score)and walking function("up-and-go"time and 6 m pace test results)as well as the patient's psychological status assessment.RESULTS AND CONCLUSION:All 375 patients completed 12 weeks of rehabilitation training and 12 weeks of follow-up without any adverse events.(1)Compared with before training,the patients' gait speed and knee range of motion increased significantly after 12 weeks of rehabilitation training(P<0.01),the time of"stand-to-walk"decreased(P<0.01),and the proprioception of the knee joint and the strength of the quadriceps femoris were significantly improved(P<0.01);and at the follow-up visit 12 weeks after stopping training,the above indicators and functions of the patients were well maintained(P>0.05).(2)Magnetic resonance imaging results showed that the effective cross-sectional area of the quadriceps femoris did not improve significantly after 12 weeks of rehabilitation training(P>0.05);but the Hospital for Special Surgery score of knee joint function increased significantly(P<0.01),and the visual analog pain scale score decreased significantly(P<0.01),suggesting that this may be related to the improvement of quadriceps femoris quality by resistance rehabilitation training.(3)The results of the Hospital Anxiety and Depression Scale score showed that the anxiety and depression scores of the patients continued to decrease,both at 12 weeks of rehabilitation training and at 12 weeks after stopping training(P<0.01).It is suggested that resistance rehabilitation training of the quadriceps can help patients with osteoporosis and sarcopenia to restore quadriceps muscle strength,increase range of motion,improve proprioception and joint stability,thereby enhancing knee joint function,reducing pain,improving depression and anxiety,and to a certain extent promoting the coordinated recovery of the musculoskeletal system.
3.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
4.Effects of resistance training on quadriceps mass and knee joint function in patients with osteoporosis and sarcopenia
Jian ZHOU ; Tao ZHANG ; Weili ZHOU ; Xingcheng ZHAO ; Jun WANG ; Jie SHEN ; Li QIAN ; Ming LU
Chinese Journal of Tissue Engineering Research 2026;30(5):1081-1088
BACKGROUND:The quadriceps strength of patients with osteoporosis and sarcopenia is significantly reduced,which can further reduce the function of the knee joint,affect the function of the lower limbs and even lead to a decrease in whole-body coordination.It is speculated that a reasonable quadriceps training program and personalized guidance are beneficial to the recovery of knee joint function in patients with osteoporosis and sarcopenia.OBJECTIVE:To observe the effect of short-term moderate-intensity resistance rehabilitation training on the mass and function of the quadriceps and knee joint function in patients with osteoporosis and sarcopenia.METHODS:Using the integrated physical examination and rehabilitation model,375 patients with osteoporosis and sarcopenia were screened at the Health Management Center of Shanghai Public Health Clinical Center.They underwent 12 weeks of combined/comprehensive exercise rehabilitation based on resistance exercise,including quadriceps resistance isotonic and isometric contraction training twice a week(3-5 sets each time,10-15 minutes per set)and aerobic exercise/balance exercise two or three times a week(30 minutes each time).Assessments and data collection were performed before rehabilitation training,12 weeks after rehabilitation training,and at follow-up 12 weeks after stopping rehabilitation training,mainly including knee joint range of motion and proprioception,quadriceps muscle strength,and cross-sectional area(magnetic resonance imaging results),pain,knee joint function(Hospital for Special Surgery score)and walking function("up-and-go"time and 6 m pace test results)as well as the patient's psychological status assessment.RESULTS AND CONCLUSION:All 375 patients completed 12 weeks of rehabilitation training and 12 weeks of follow-up without any adverse events.(1)Compared with before training,the patients' gait speed and knee range of motion increased significantly after 12 weeks of rehabilitation training(P<0.01),the time of"stand-to-walk"decreased(P<0.01),and the proprioception of the knee joint and the strength of the quadriceps femoris were significantly improved(P<0.01);and at the follow-up visit 12 weeks after stopping training,the above indicators and functions of the patients were well maintained(P>0.05).(2)Magnetic resonance imaging results showed that the effective cross-sectional area of the quadriceps femoris did not improve significantly after 12 weeks of rehabilitation training(P>0.05);but the Hospital for Special Surgery score of knee joint function increased significantly(P<0.01),and the visual analog pain scale score decreased significantly(P<0.01),suggesting that this may be related to the improvement of quadriceps femoris quality by resistance rehabilitation training.(3)The results of the Hospital Anxiety and Depression Scale score showed that the anxiety and depression scores of the patients continued to decrease,both at 12 weeks of rehabilitation training and at 12 weeks after stopping training(P<0.01).It is suggested that resistance rehabilitation training of the quadriceps can help patients with osteoporosis and sarcopenia to restore quadriceps muscle strength,increase range of motion,improve proprioception and joint stability,thereby enhancing knee joint function,reducing pain,improving depression and anxiety,and to a certain extent promoting the coordinated recovery of the musculoskeletal system.
5.Clinicopathological Characteristics of HER2-Positive Breast Cancer Patients with BRCA1/2 Pathogenic Variants and Their Response to Neoadjuvant Targeted Therapy
Xingyu LIAO ; Huimin LIU ; Jie SUN ; Li HU ; Juan ZHANG ; Lu YAO ; Ye XU ; Yuntao XIE
Cancer Research on Prevention and Treatment 2025;52(6):491-495
Objective To analyze the proportion and clinicopathological characteristics of HER2-positive breast cancer patients with BRCA1/2 pathogenic variants, and their response to neoadjuvant anti-HER2 targeted therapy. Methods The clinicopathological data of 531 breast cancer patients with germline BRCA1/2 pathogenic variants (201 with BRCA1 variants and 330 with BRCA2 variants) were analyzed. Results Among the 201 BRCA1 and 330 BRCA2 variants, 17 (8.5%) and 42 (12.7%) HER2-positive breast cancer cases were identified, respectively, accounting for 11.1% of all BRCA1/2-mutated breast cancers. Compared with BRCA1/2-mutated HR-positive/HER2-negative patients, HER2-positive patients did not present any significant differences in clinicopathological features; however, compared with triple-negative breast cancer patients, HER2-positive patients had a later onset age and lower tumor grade. Among the 17 patients who received neoadjuvant anti-HER2 targeted therapy, 10 cases achieved pCR (58.8%), whereas 7 cases did not (41.2%). Conclusion HER2-positive breast cancer accounts for more than 10% of BRCA1/2-mutated patients. Approximately 40% of these patients fail to achieve pCR after neoadjuvant targeted therapy. This phenomenon highlights the possibility of combining anti-HER2 targeted agents with poly (adenosine diphosphate-ribose) polymerase inhibitors.
6.Application of a pre-intelligent precision dosing and verification system in automatic single-dose packaging
Runzan ZHANG ; Junyu LU ; Lei HONG ; Liucheng LI ; Jie YING
China Pharmacy 2025;36(17):2170-2175
OBJECTIVE To innovatively apply the pre-intelligent precision dosing and verification system (hereinafter referred to as “the system”), and to provide a reference for the high-level “intelligent” transformation of inpatient pharmacy. METHODS The limitations of the triple-serial dispensing mode, which comprised the automatic medicine packaging machine (ATC), intelligent tablet dispensing table (ITDT) and medication detection machine (MDM), were analyzed. The application of the system and the adoption of the barcode scanning verification method optimized the pre-dosing management, whole-tablet drug dispensing process and ATC temporary dosing management. The comparative analysis was conducted to assess dosing time, labor cost and packaging error of the eight-month period, before and after the system application. RESULTS The triple-serial dispensing mode had a weak ability to avoid error risks in the manual dosing stage, and also had errors in the verification stage. Through the innovative application system, the pre-dosing management had been upgraded, the whole-tablet drug dispensing process had been optimized, and the ATC temporary dosing management had been improved. The average time required for each drug for pre-dosing, whole-tablet drug dispensing and ATC temporary dosing was significantly shortened after the application of the system, compared with before the application of the system (P<0.001). The number of pharmacists was reduced from two to one. The error rate of ATC decreased significantly from 0.220‰ to 0.029‰ (P<0.001). Specifically, the rate of pharmacist-related errors (pre-dosing error, ITDT dosing error, and ATC temporary dosing error) decreased from 0.116‰ to 0.001‰ (P<0.001), and machine-related errors decreased from 0.096‰ to 0.023‰ (P<0.001). CONCLUSIONS This innovative integration mode greatly improves the working efficiency and quality of inpatient pharmacy. It enhances refined management of drug expiration and inventory, saves time and labor costs, improves the accuracy of drug dispensing, and ensures patient medication safety.
7.Investigation of an outbreak of group A human G9P [8] rotavirus infectious diarrhea among adults in Chongqing
Yang WANG ; Yuan KONG ; Ning CHEN ; Lundi YANG ; Jiang LONG ; Qin LI ; Xiaoyang XU ; Wei ZHENG ; Hong WEI ; Jie LU ; Quanjie XIAO ; Yingying BA ; Wenxi WU ; Qian XU ; Ju YAN
Shanghai Journal of Preventive Medicine 2025;37(8):663-668
ObjectiveTo investigate and analyze an outbreak of rotavirus infectious diarrhea in a prison in Chongqing Municipality, to provide a basis for adult rotavirus surveillance and prevention, and to explore the public health problems in special settings. MethodsA retrospective survey was conducted to collect and analyze data on individual cases with diarrheal disease on-site. The clinical characteristics, as well as the temporal, spatial and geographical distribution patterns of the epidemic were described. Multi-pathogen detection tests were conducted both on diarrhea cases and environmental samples, with viral genotyping performed on positive samples. A case-control analysis was performed to identify the causes of the outbreak, and an SEIR model was adopted to predict the outbreak trend and evaluate the effectiveness of interventions. ResultsA total of 65 cases were found among the inmates, with an attack rate of 2.03%. The predominant clinical manifestations included diarrhea (89.23%), watery stool (73.85%), and dehydration (18.46%). The epidemic curve indicated a “human-to-human” transmission pattern, with an average incubation period of 5‒6 days. The attack rates among chefs in the main canteen (80.00%, 8/10) and caterers (28.33%, 17/60) were significantly higher than those of other inmates (P<0.05). Multi-pathogen polymerase chain reaction (PCR) testing detected positive for group A rotavirus, with the viral genotyping identified as G9P [8] strain. Factors such as unprotected "bare-handed" food distribution among cases with diarrhea (OR=9.512, 95%CI: 4.261‒21.234) and close contact with diarrhea cases (OR=3.656, 95%CI: 1.719‒7.778) were the possible cause of the outbreak. The SEIR model (r0=5, α=0.3, β1=0.08, β2=0.04) was constructed using prison inmates as susceptible population, aiming at fitting the initial transmission trend of the outbreak, and the epidemic rate declined rapidly after intervention measures were implemented (rt≈0). ConclusionThis rare rotavirus infection diarrhea outbreak among adults in confined settings suggests that the construction of public health prevention and control systems in prison may be overlooked. Cross infection during meal processing and distribution in the canteens of such settings is likely to be the cause of the outbreak. Given the potential neglect of public heath system construction in special settings, it is imperative to enhance the surveillance and monitoring of rotavirus and other intestinal multi-pathogens among adults, as well as the construction of public health prevention and control systems in these special settings.
8.The effectiveness and safety of a percutaneous controllable curved plasma radiofrequency ablation device of nucleus pulposus
Hao ZHOU ; Qianyi ZHANG ; Jiajie LU ; Tao WU ; Yituo CHEN ; Qichen ZHANG ; Xilei LI ; Haikang CAI ; Jie TANG
Chinese Journal of Clinical Medicine 2025;32(4):659-664
Objective To verify the safety and effectiveness of a new percutaneous controllable curved plasma radiofrequency instrument for nucleus pulposus ablation. Methods A new percutaneous controllable curved plasma radiofrequency instrument were designed (controllable curved group), and its ablation effect was compared with the currently used straight head non-bendable plasma ablation instrument (non-bendable group) on gross specimens. The ablation instrument was placed through the right intervertebral foramen, and continuous ablation on the same intervertebral disc was conducted for three times. The ablation range and trajectory were recorded, and the temperature changes in the front, back, left, and right of the ablation center during and 15 seconds after ablation were monitored by the inserted temperature probe. Results There were no difference in temperature changes in the front, back, right regions of the ablation center during and 15 seconds after ablation between the two groups. The temperature changes in the left region of the ablation center both during and 15 seconds after 3rd ablation were larger than those in the non-bendable group (P<0.01). Compared with the non-bendable group, the controllable curved group achieved angle control and larger single ablation area (2.282 5 mm² vs 1.135 8 mm², P<0.000 1). Conclusions This new percutaneous controllable curved plasma ablation instrument can achieve angle control and ablation on the side opposite to the puncture site, increase ablation volume, and is safe.
9.Research and development of sterile electrode acupuncture needle for single use based on medicine-engineering integration and its clinical application.
Wanying XIA ; Tianxin LI ; Lingli QIN ; Yue GAO ; Hanxi DAI ; Jie ZHANG ; Jinsheng YANG ; Lu ZHANG
Chinese Acupuncture & Moxibustion 2025;45(10):1527-1532
The sterile electrode acupuncture needle for single use is an innovative product that combines traditional acupuncture with modern electronic technology, and it has obtained Class Ⅱ medical device registration certificate. This acupuncture device consists of a needle body and a handle. The diameter of the needle body ranges from 0.16 mm to 0.55 mm, and the length from 7 mm to 150 mm. The spiral spray technology is adopted to modify the micron-level insulating coat on stainless steel needle body. The needle holder is connected to the electroacupuncture device (conductive), the micro-film insulated needle body (non-conductive) and the membrane-free needle tip (conductive) can provide a precise electrical stimulation for different tissue layers of acupoints (such as deep nerves and fascia). The intradermal stimulation test, cytotoxicity test and hypersensitivity reaction test have showed a favorable biocompatibility, laying a solid and reliable safety for clinical application. This acupuncture device is suitable for the in-depth invasive stimulation at the sites of human body surface in combination with electroacupuncture equipment in medical institutions.
Humans
;
Needles
;
Acupuncture Therapy/instrumentation*
;
Electrodes
;
Equipment Design
;
Electroacupuncture/instrumentation*
;
Acupuncture Points
;
Animals
10.Current status of generalized pustular psoriasis: Findings from a multicenter hospital-based survey of 127 Chinese patients.
Haimeng WANG ; Jiaming XU ; Xiaoling YU ; Siyu HAO ; Xueqin CHEN ; Bin PENG ; Xiaona LI ; Ping WANG ; Chaoyang MIAO ; Jinzhu GUO ; Qingjie HU ; Zhonglan SU ; Sheng WANG ; Chen YU ; Qingmiao SUN ; Minkuo ZHANG ; Bin YANG ; Yuzhen LI ; Zhiqiang SONG ; Songmei GENG ; Aijun CHEN ; Zigang XU ; Chunlei ZHANG ; Qianjin LU ; Yan LU ; Xian JIANG ; Gang WANG ; Hong FANG ; Qing SUN ; Jie LIU ; Hongzhong JIN
Chinese Medical Journal 2025;138(8):953-961
BACKGROUND:
Generalized pustular psoriasis (GPP), a rare and recurrent autoinflammatory disease, imposes a substantial burden on patients and society. Awareness of GPP in China remains limited.
METHODS:
This cross-sectional survey, conducted between September 2021 and May 2023 across 14 hospitals in China, included GPP patients of all ages and disease phases. Data collected encompassed demographics, clinical characteristics, economic impact, disease severity, quality of life, and treatment-related complications. Risk factors for GPP recurrence were analyzed.
RESULTS:
Among 127 patients (female/male ratio = 1.35:1), the mean age of disease onset was 25 years (1st quartile [Q1]-3rd quartile [Q3]: 11-44 years); 29.2% had experienced GPP for more than 10 years. Recurrence occurred in 75.6% of patients, and nearly half reported no identifiable triggers. Younger age at disease onset ( P = 0.021) and transitioning to plaque psoriasis ( P = 0.022) were associated with higher recurrence rates. The median diagnostic delay was 8 months (Q1-Q3: 2-41 months), and 32.3% of patients reported misdiagnoses. Comorbidities were present in 53.5% of patients, whereas 51.1% experienced systemic complications during treatment. Depression and anxiety affected 84.5% and 95.6% of patients, respectively. During GPP flares, the median Dermatology Life Quality Index score was 19.0 (Q1-Q3: 13.0-23.5). This score showed significant differences between patients with and without systemic symptoms; it demonstrated correlations with both depression and anxiety scores. Treatment costs caused financial hardship in 55.9% of patients, underscoring the burden associated with GPP.
CONCLUSIONS
The substantial disease and economic burdens among Chinese GPP patients warrant increased attention. Patients with early onset disease and those transitioning to plaque psoriasis require targeted interventions to mitigate the high recurrence risk.
Humans
;
Male
;
Female
;
Psoriasis/pathology*
;
Adult
;
Cross-Sectional Studies
;
Adolescent
;
Child
;
Young Adult
;
Quality of Life
;
Middle Aged
;
China/epidemiology*
;
Recurrence
;
Risk Factors
;
Surveys and Questionnaires
;
East Asian People

Result Analysis
Print
Save
E-mail