1.Effects and mechanism of paeoniflorin on oxidative stress of ulcerative colitis mice
Xin DAI ; Ying WANG ; Xinyue REN ; Dingxing FAN ; Xianzhe LI ; Jiaxuan FENG ; Shilei LOU ; Hui YAN ; Cong SUN
China Pharmacy 2025;36(4):427-433
OBJECTIVE To investigate the effects and potential mechanism of paeoniflorin on oxidative stress of ulcerative colitis (UC) mice based on adenosine monophosphate-activated protein kinase (AMPK)/nuclear factor-erythroid 2-related factor 2 (Nrf2) pathway. METHODS Male BALB/c mice were randomly divided into control group, model group, inhibitor group (AMPK inhibitor Compound C 20 mg/kg), paeoniflorin low-, medium- and high-dose groups (paeoniflorin 12.5, 25, 50 mg/kg), high- dose of paeoniflorin+inhibitor group (paeoniflorin 50 mg/kg+Compound C 20 mg/kg), with 8 mice in each group. Except for the control group, mice in all other groups were given 4% dextran sulfate sodium solution for 5 days to establish the UC model. Subsequently, mice in each drug group were given the corresponding drug solution intragastrically or intraperitoneally, once a day, for 7 consecutive days. The changes in body weight of mice were recorded during the experiment. Twenty-four hours after the last administration, colon length, malondialdehyde (MDA) content, and activities of superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px) in colon tissues were measured; histopathological morphology of colon tissues, tight junctions between intestinal epithelial cells, and histopathological scoring were all observed and evaluated; the mRNA expressions of AMPK and Nrf2, as well as the protein expressions of heme oxygenase-1(HO-1), occludin and claudin-1, were all determined in colon tissue. RESULTS Compared with model group, paeoniflorin groups exhibited recovery from pathological changes such as inflammatory cell infiltration and crypt damage in the colon tissue, as well as improved tight junction damage between intestinal epithelial cells. Additionally, significant increases or upregulations were observed in body weight, colon length, activities of SOD and GSH-Px, phosphorylation level of AMPK, and protein expression of Nrf2, HO-1, occludin, claudin-1, and mRNA expressions of AMPK and Nrf2; concurrently, MDA content and histopathological scores were significantly reduced (P< 0.05 or P<0.01). In contrast, the inhibitor group showed comparable (P>0.05) or worse (P<0.05 or P<0.01) indicators compared to the model group. Conversely, the addition of AMPK inhibitor could significantly reverse the improvement of high- dose paconiflorin (P<0.01). CONCLUSIONS Paeoniflorin can repair intestinal epithelial cell damage in mice, improve tight junctions between epithelial cells, upregulate the expression of related proteins, and promote the expression and secretion of antioxidant-promoting molecules, thereby ameliorating UC; its mechanism may be associated with activating AMPK/Nrf2 antioxidant pathway.
2.Construction of Tax-PC/SDC/PVP-K30 micelles and their protective effect on alcoholic liver injury
Shi-yu ZHANG ; Jing-meng SUN ; Dong-dong LI ; Xin ZHANG ; Jia-hui ZHANG ; Wei-yu ZHANG
Acta Pharmaceutica Sinica 2025;60(2):488-497
Taxifolin (Tax) has been proved to be a medicinal edible substance with protective effects against alcoholic liver injury, however, its poor hydrophilicity and permeability have hindered the clinical application of Tax. In this study, we prepared taxifolin-phosphatidylcholine/sodium deoxycholate/PVP-K30 micells (Tax-MLs). Box-Behnken test was used to obtain the optimal preparation process, and Tax-MLs were characterised by transmission electron microscopy and fourier transform infrared spectroscopy. Physicochemical parameters such as proximate micelle concentration, equilibrium solubility and oil-water partition coefficient were determined, and the release pattern of Tax-MLs was investigated by
3.Body Composition Profiles and Associated Factors in Adolescents UndergoingLong-term Regular Exercise
Yutong WANG ; Xiaoyuan GUO ; Hanze DU ; Hui PAN ; Wei WANG ; Mei ZHANG ; Bo BAN ; Ping LI ; Xinran ZHANG ; Qiuping ZHANG ; Hongshuang SUN ; Rong LI ; Shi CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(3):591-597
To investigate body composition and associated factors in adolescents undergoing long-term regular sports training. This prospective longitudinal cohort study employed convenience sampling to recruit adolescents receiving structured athletic training at Jining Sports Training Center in June 2023. Baseline measurements included height, weight, body mass index (BMI), blood pressure, heart rate, waist circumference, and hip circumference. Questionnaires assessed sleep duration, screen time, and household income. Follow-up measurements in June 2024 repeated these assessments while adding bioelectrical impedance analysis for body composition (lean mass, skeletal muscle mass, fat mass, and body fat percentage). Linear regression models examined associations between training type (direct-contact vs. non-contact sports) and follow-up body fat percentage, BMI, and waist circumference as dependent variables, adjusting for covariates. The study included 110 adolescents (39 female, 71 male) with median age 13.21 years (IQR: 12.46-14.33). Participants comprised 65 direct-contact and 45 non-contact athletes. Baseline prevalence rates were 27.27% for overweight/obesity, 24.55% for elevated waist circumference, and 16.36% for elevated blood pressure. At follow-up, corresponding rates were 24.55%, 26.36%, and 13.64% respectively. The elevated blood pressure subgroup showed significantly higher waist circumference ( Despite regular athletic training, substantial proportions of adolescents exhibited overweight/obesity, abdominal obesity, and elevated blood pressure, warranting clinical attention. Training modality appears to influence body composition changes, with direct-contact sports associated with more favorable adiposity-related outcomes.
4.Proportions of memory T cells and expression of their associated cytokines in lymph nodes of mice infected with Echinococcus multilocularis
Yinshi LI ; Duolikun ADILAI ; Bingqing DENG ; Ainiwaer ABIDAN ; Sheng SUN ; Wenying XIAO ; Conghui GE ; Na TANG ; Jing LI ; Hui WANG ; Tao JIANG ; Chuanshan ZHANG
Chinese Journal of Schistosomiasis Control 2025;37(2):136-143
Objective To investigate the effects of Echinococcus multilocularis infection on levels of memory T (Tm) cells and their subsets in lymph nodes of mice at different stages of infection, so as to provide new insights into immunotherapy for alveolarechinococcosis. MethodsTwenty-four C57BL/6J mice aged 6 to 9 weeks were randomly divided into the infection group and the control group, of 12 mice in each group. Mice in the infection group were administered with 3 000 E. multilocularis protoscoleces via portal venous injection, while animals in the control group were administered with an equal volume of physiological saline. Three mice from each group were sacrificed 4, 12 weeks and 24 weeks post-infection, and lymph nodes were sampled and stained with hematoxylin and eosin (HE) to investigate the histopathological changes of mouse lymph nodes in the infection group. The expression and localization of T lymphocyte surface markers CD3, CD4, and CD8 were observed in mouse lymph nodes using immunohistochemical staining. In addition, lymphocyte suspensions were prepared from mouse lymph nodes in both groups at different time points post-infection, and the levels of Tm cell subsets and their secreted cytokines were detected using flow cytometry. Results HE staining showed diffuse structural alterations in the subcapsular cortical and paracortical regions of mouse lymph nodes in the infection group 4 weeks post-infection with E. multilocularis. Immunohistochemical staining detected CD3, CD4 and CD8 expression in mouse lymph nodes in both groups. Flow cytometry revealed higher proportions of CD4+ Tm cells [(55.3 ± 4.8)% vs. (38.8 ± 6.1)%; t = -4.259, P < 0.05] and CD4+ tissue-resident Tm (Trm) cells [(57.7 ± 3.7)% vs. (34.1 ± 11.2)%; t = -3.990, P < 0.05] in mouse lymph nodes in the infection group than in the control group 4 weeks post-infection, and higher proportions of CD4+ Tm cells [(34.6 ± 3.2)% vs. (23.3 ± 7.5)%; t = -2.764, P < 0.05] and CD4+ Trm cells [(44.0 ± 1.9)% vs. (31.2 ± 1.5)%; t = -4.039, P < 0.05] in mouse lymph nodes in the infection group than in the control group 24 weeks post-infection. The proportions of CD8+ Tm cells were higher in the infection group than in the control group 4 weeks [(56.8 ± 2.7)% vs. (43.9 ± 5.2)%; t = -4.416, P < 0.01] and 12 weeks post-infection [(25.4 ± 2.7)% vs. (12.0 ± 2.6)%; t = -2.552, P < 0.05], while the proportions of tumor necrosis factor (TNF)-α+ CD4+ T cells [(15.7 ± 5.0)% vs. (49.4 ± 6.4)%; t = 7.150, P < 0.01], TNF-α+CD8+ T cells [(20.7 ± 5.5)% vs. (57.5 ± 8.4)%; t = -6.694, P < 0.01], and TNF-α+ CD8+ Tm cells [7.0% (1.0%) vs. 31.0% (11.0%); Z = -2.236, P < 0.05] were lower in the infection group than in the control group 24 weeks post-infection. Conclusions Tm cells levels are consistently increased in lymph nodes of mice at different stages of E. multilocularis infection, with Trm cells as the predominantly elevated subset. The impaired capacity of CD8+ Tm cells to secrete the effector molecule TNF-α in mouse lymph nodes at the late-stage infection may facilitate chronic parasitism of E. multilocularis.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Bioactive metabolites: A clue to the link between MASLD and CKD?
Wen-Ying CHEN ; Jia-Hui ZHANG ; Li-Li CHEN ; Christopher D. BYRNE ; Giovanni TARGHER ; Liang LUO ; Yan NI ; Ming-Hua ZHENG ; Dan-Qin SUN
Clinical and Molecular Hepatology 2025;31(1):56-73
Metabolites produced as intermediaries or end-products of microbial metabolism provide crucial signals for health and diseases, such as metabolic dysfunction-associated steatotic liver disease (MASLD). These metabolites include products of the bacterial metabolism of dietary substrates, modification of host molecules (such as bile acids [BAs], trimethylamine-N-oxide, and short-chain fatty acids), or products directly derived from bacteria. Recent studies have provided new insights into the association between MASLD and the risk of developing chronic kidney disease (CKD). Furthermore, alterations in microbiota composition and metabolite profiles, notably altered BAs, have been described in studies investigating the association between MASLD and the risk of CKD. This narrative review discusses alterations of specific classes of metabolites, BAs, fructose, vitamin D, and microbiota composition that may be implicated in the link between MASLD and CKD.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Bioactive metabolites: A clue to the link between MASLD and CKD?
Wen-Ying CHEN ; Jia-Hui ZHANG ; Li-Li CHEN ; Christopher D. BYRNE ; Giovanni TARGHER ; Liang LUO ; Yan NI ; Ming-Hua ZHENG ; Dan-Qin SUN
Clinical and Molecular Hepatology 2025;31(1):56-73
Metabolites produced as intermediaries or end-products of microbial metabolism provide crucial signals for health and diseases, such as metabolic dysfunction-associated steatotic liver disease (MASLD). These metabolites include products of the bacterial metabolism of dietary substrates, modification of host molecules (such as bile acids [BAs], trimethylamine-N-oxide, and short-chain fatty acids), or products directly derived from bacteria. Recent studies have provided new insights into the association between MASLD and the risk of developing chronic kidney disease (CKD). Furthermore, alterations in microbiota composition and metabolite profiles, notably altered BAs, have been described in studies investigating the association between MASLD and the risk of CKD. This narrative review discusses alterations of specific classes of metabolites, BAs, fructose, vitamin D, and microbiota composition that may be implicated in the link between MASLD and CKD.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save