1.A preliminary study on developing statistical distribution table of hearing threshold deviation for otologically normal Chinese adults
Linjie WU ; Yang LI ; Haiying LIU ; Anke ZENG ; Jinzhe LI ; Wei QIU ; Hua ZOU ; Meng YE ; Meibian ZHANG
Journal of Environmental and Occupational Medicine 2025;42(7):800-807
background Current assessment of noise-induced hearing loss relies on the hearing threshold statistical distribution table of ISO 7029-2017 standard (ISO 7029), which is based on foreign population data and lacks a hearing threshold distribution table derived from pure-tone audiometry data of the Chinese population, hindering accurate evaluation of hearing loss in this group. Objective To establish a statistical distribution table of hearing threshold level (HTL) for otologically normal Chinese adults and to provide a scientific basis for revising the diagnostic criteria of occupational noise-induced deafness in China. Methods A total of
2.Identification and pedigree study of a case with McLeod phenotype caused by XK gene c. 107G>A mutation
Yan ZHANG ; Yunxiang WU ; Fei WANG ; Aijing LI ; Hua WANG ; Minghao LI ; Demei ZHANG ; Luyi YE
Chinese Journal of Blood Transfusion 2025;38(9):1253-1258
Objective: To identify the phenotypes, antibodies and explore the molecular mechanisms of a patient who carries antibodies to RBC high-frequency antigens and his family members. Methods: The antibody identification test was performed for the proband by serological methods, and targeted NGS was subsequently used to detect mutations that occurred in blood group genes. Blood samples were collected from the proband and his family members. Sanger sequencing was used to verify the mutation of the XK gene. The expression of Kell blood group antigens was detected by serological methods and flow cytometry. K
cells were used to detect the antibody specificity of the proband. The morphology of red blood cells was detected by the scanning electron microscopy. The serum creatine kinase levels of the proband and his family members were analyzed by colorimetric methods. Results: The results of the antibody identification test suggested that the proband might have antibodies to high-frequency antigens. NGS results suggested a homozygous mutation (c. 107G>A) in exon 1 of the XK gene in the proband, resulting in a truncated XK protein. The Sanger sequencing results of the proband were consistent with the NGS results, and the mutation was not found in other family members. The expression of Kell blood group antigens of the proband was not found by serological methods and flow cytometry. The results of the antibody specificity test showed that the proband had anti-Km antibodies. Spike-like changes were identified on red blood cells, and serum creatine kinase level was elevated in the proband. Conclusion: In this study, the McLeod phenotype caused by homozygous mutation (c. 107G>A) of XK gene was identified in Chinese individuals for the first time by the phenotype and molecular mechanism studies. The results of genotyping and phenotyping suggested that the McLeod phenotype caused by the mutation was compatible with the phenotypes of McLeod and K
.
3.Effects of Panax notoginseng saponins on the expression of sortilin and cholesterol metabolism in macrophages
Lei GAO ; Xiu-Hua SUN ; Qin-Yang JIN ; Qi XUE ; Li-Fang YE ; Jian-Lei ZHENG
The Chinese Journal of Clinical Pharmacology 2024;40(13):1893-1897
Objective To explore the role of Panax notoginseng saponins(PNS)in regulating the expression of sortilin and ATP-binding cassette transporter A1(ABCA1)in macrophages,and the effect of PNS on inhibiting formation of foam cells and the potential mechanism of PNS adjusting sortilin expression and cholesterol metabolism.Methods The macrophages were divided into five groups as follows:group A(only added with cell culture),group B(transfected with negative control lentivirus),group C(transfected with lentivirus-mediated sortilin overexpression),group D(transfected with lentivirus-mediated sortilin overexpression+60 μg·mL-1PNS),group E(transfected with lentivirus-mediated sortilin overexpression+10 μmol·L-1 mitogen-activated protein kinase kinase(MEK)inhibitor PD98059+60 μg·mL-1 PNS).The protein contents of sortilin,ABCA1,extracellular signal-regulated kinase(ERK)and phosphorylated-ERK(p-ERK)were evaluated with Western blot.All the cells in five groups were cultured with 50 μg·mL-1ox-LDL to form foam cells.The lipid in macrophages was investigated with red O assay.Results The relative expression levels of sortilin protein were 1.00±0.08,0.91±0.15,2.28±0.13,1.62±0.09 and 2.01±0.08;the relative expression levels of ABCA1 protein were 1.00±0.01,0.92±0.07,0.29±0.04,0.66±0.09 and 0.44±0.07;the ratios of p-ERK/ERK protein were 1.00±0.09,0.92±0.05,1.03±0.12,2.00±0.12 and 1.64±0.14;the contents of lipid in macrophages were(4.82±2.19)%,(6.70±0.88)%,(44.56±4.15)%,(27.66±3.25)%and(41.67±5.45)%.Except the ratios of p-ERK/ERK,the other parameters between group C and group A were statistically significant difference(all P<0.01).Meanwhile,there were also statistically significant difference between group D and group C as well as group D and group E(P<0.05,P<0.01).Conclusion PNS inhibits the lipid accumulation in macrophages through upregulating ABCA1 and downregulating sortilin,and ERK signaling pathway may be as one of important mechanisms influencing the expression of sortilin and ABCA1 mediated by PNS.
4.Research status on the role of NLRP3 inflammasome in tumor micro-environment on breast cancer metastasis
Lin-Ye HUA ; Hong-Shan LUO ; Xiu-Lian LIN ; Li-Mei LIN ; Bo-Hou XIA ; Ya-Mei LI
The Chinese Journal of Clinical Pharmacology 2024;40(14):2148-2152
The expression level of NOD-like receptors(NLRP3)inflammasome is significantly elevated in breast cancer tissues,and a high level of NLRP3 inflammasomes is closely associated with breast cancer metastasis.Activation of NLRP3 inflammasome can induce the release of inflammatory factors into the tumor microenvironment(TME).These inflammatory factors,by signaling to cancer cells,reshape the TME to promote tumor growth and invasion,ultimately facilitating the process of epithelial-mesenchymal transition.This equips cancer cells with the ability to establish distant metastases and increase the formation of metastatic lesions.This review addresses the current research status and prospects of NLRP3 inflammasomes in the breast cancer TME and their role in breast cancer metastasis.The goal is to provide new insights for the study of breast cancer metastasis mechanisms and treatment strategies.
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Sex education practice by preschool teachers in Luzhou City
JIANG Qinling ; YAN Run ; XIA Hua ; LI Mao ; YE Yunli
Journal of Preventive Medicine 2024;36(8):723-726
Objective:
To investigate the implementation of sex education and its influencing factors among preschool teachers in Luzhou City, Sichuan Province, so as to provide insights into promoting the development of sex education, physical and mental health for preschool children.
Methods:
In January 2022, preschool teachers were sampled in 24 kindergartens in Longmatan District, Naxi District and Hejiang County of Luzhou City using the stratified random cluster sampling method. Demographic information, knowledge, attitudes, implementation of sex education, as well as difficulties, support, and needs in implementing sex education among preschool teachers were collected through questionnaire surveys. Factors affecting practice of sex education by preschool teachers were analyzed using a multivariable logistic regression model.
Results:
A total of 461 preschool teachers were included, including 456 females (98.92%), and had a median age of 28.00 (interquartile range, 9.50) years. The proportions of preschool teachers with good and pass of knowledge about sex education for preschool children were 10.20% and 57.48%, respectively. The proportions of preschool teachers with positive and general attitudes towards sex education were 28.20% and 36.44%, respectively. A total of 343 preschool teachers had implemented sex education (74.40%). A lack of a relaxed social environment was the main difficulty in carrying out sex education for preschool children (76.14%), while support from parents of preschool children was the primary need for conducting sex education activities (75.27%). Multivariable logistic regression analysis showed that age (>30 years, OR=2.218, 95%CI: 1.256-3.917), kindergarten type (public, OR=2.101, 95%CI: 1.253-3.524), attitude towards sex education (positive, OR=2.083, 95%CI: 1.036-4.187), participation in activities related to sex education (OR=6.355, 95%CI: 3.362-12.015), and communication with parents about sex education (OR=5.399, 95%CI: 3.152-9.248) were influencing factors for practice of sex education by preschool teachers.
Conclusions
The main difficulty in the practice of sex education for preschool children by preschool teachers in Luzhou City is a lack of a relaxed social environment, and there is a high demand for support from parents. Age, kindergarten type, attitude towards sex education, participation in activities related to sex education, and communication with parents about sex education are associated factors.
10.Mechanism of Morinda officinalis iridoid glycosides alleviates bone deterioration in type II collagen-induced arthritic rats through down-regulating GSK-3β to inhibit JAK2/STAT3 and NF-κ B signaling pathway
Yi SHEN ; Yi-qi SUN ; He-ming LI ; Xin-yuan YE ; Jin-man DU ; Rong-hua BAO ; Quan-long ZHANG ; Lu-ping QIN ; Qiao-yan ZHANG
Acta Pharmaceutica Sinica 2024;59(10):2763-2772
This study aimed to investigate the therapeutic effects of


Result Analysis
Print
Save
E-mail