1.Current quality status and management countermeasures of occupational health technical services in Zhejiang Province
Qiuliang XU ; Feng HAN ; Peng WANG ; Zhen ZHOU ; Fei LI ; Hongwei XIE ; Yong HU ; Weiming YUAN ; Lifang ZHOU ; Hua ZOU
Journal of Environmental and Occupational Medicine 2026;43(3):341-346
Background The quality of occupational health technical services is directly linked to the protection of workers' health rights and the efficacy of occupational disease prevention and control. However, the industry still faces critical challenges: sporadic instances of institutional non-compliance and persistent irregularities in professional practice continue to undermine overall service performance. Objective To assess the current quality status of occupational health technical services in Zhejiang Province and propose countermeasures for quality improvement, providing a scientific basis for policy optimization and service delivery quality enhancement. Methods A total of 69 occupational health technical service institutions in Zhejiang Province that obtained formal accreditation as of April 30, 2024, were sampled, including 3 public institutions and 66 private institutions (comprising 3 formerly Class-A, 28 formerly Class-B, 11 formerly Class-C, and 24 newly certified institutions). Following the Technical Protocol for Quality Monitoring of Occupational Health Technical Service in Zhejiang Province and the Technical Protocol for Proficiency Testing of Occupational Health Detection in Zhejiang Province, a quality assessment task force comprising national and provincial experts was established. Evaluation was conducted across four dimensions: qualification maintenance and compliance, standardization of technical services, authenticity of technical services, and proficiency testing, utilizing a combination of document review, on-site inspections, and technical skill assessments. Results The occupational health technical service institutions in Zhejiang Province were predominantly private entities (82.5%), with significant disparities in overall service quality. The pass rates for qualification maintenance and compliance, technical service standardization, technical service authenticity, and the excellence rate for laboratory proficiency testing were 81.5%, 80.7%, 97.3%, and 90.4%, respectively. Regarding qualification maintenance, the pass rates for "environmental conditions" (49.8%, 56.7%) and "instrumentation and equipment" (58.2%、65.6%) were significantly lower for formerly Class-C and newly certified institutions compared to other categories. In terms of technical standardization, "standardized on-site inspections" recorded the lowest pass rate (67.4%), with newly certified institutions at only 48.0%. Regarding technical service authenticity, formerly Class-C institutions exhibited issues such as missing raw chromatograms for blank samples (85.7% pass rate). In laboratory proficiency testing, public and formerly Class-A institutions achieved 100% excellence rates, but the performance of formerly Class-C and newly certified institutions was comparatively weak; specifically, the failure rate for organic analysis in formerly Class-C institutions reached 20%; the failure rate for dust testing items in newly certified institutions was 10.3%. Conclusion The overall quality of occupational health technical services in Zhejiang Province still requires significant improvement, particularly in basic institutional conditions, the standardization of on-site inspections, and laboratory proficiency in organic and dust analysis. Formerly Class-C and newly certified institutions should be the primary focus of quality management efforts. Differentiated regulatory strategies are recommended, alongside strengthening interim and ex-post supervision to gradually enhance the quality of occupational health technical services across all institutions.
2.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
3.Study on quality control of Jinbei oral liquid based on fingerprint,chemical pattern recognition and multi-index content determination
Jing TIAN ; Weiliang CUI ; Yuanfang ZANG ; Bing WANG ; Huifen LI ; Aijun ZHANG ; Fei XUE ; Yingying XIE ; Yongqiang LIN
China Pharmacy 2026;37(13):1704-1709
OBJECTIVE To establish a quality control method for Jinbei oral liquid based on multi-wavelength switching high performance liquid chromatography (HPLC) fingerprint, chemical pattern recognition and multi-index content determination. METHODS A total of 15 batches of Jinbei oral liquid were used as test samples. The Similarity Evaluation System for Chromatographic Fingerprint of Traditional Chinese Medicine ( Version 2012 ) was adopted to establish multi-wavelength switching HPLC fingerprints, followed by chromatographic peak identification and similarity evaluation. Cluster analysis, principal component analysis and orthogonal partial least squares-discriminant analysis were applied to conduct chemical pattern recognition on the 15 batches of samples. The multi-wavelength switching HPLC method was used to simultaneously determine the contents of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, forsythoside A, baicalin, salvianoli c acid B and wogonoside in samples. RESULTS A total of 25 common peaks were calibrated in the fingerprints of 15 batches of Jinbei oral liquid, among which 7 common peaks were unambiguously identified. The similarity of all samples was higher than 0.960. Chemical pattern recognition results showed that samples S1-S8 were clustered into group 1, and samples S9-S15 were clustered into group 2. Baicalin, wogonoside, neochlorogenic acid, chlorogenic acid and salvianolic acid B were identified as the differential quality markers. The average contents of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, forsythoside A, baicalin, salvianolic acid B and wogonoside in 15 batches of Jinbei oral liquid were 0.213 7, 0.085 3, 0.104 9, 0.287 3, 0.420 1, 0.062 1, 0.176 0 mg/mL, respectively. CONCLUSIONS The established quality control method for Jinbei oral liquid combining multi-wavelength switching HPLC fingerprint, chemical pattern recognition and multi-index content determination is stable and reliable, which can provide a reference for the formulation of quality standards of this preparation.
4.Study on quality control of Jinbei oral liquid based on fingerprint,chemical pattern recognition and multi-index content determination
Jing TIAN ; Weiliang CUI ; Yuanfang ZANG ; Bing WANG ; Huifen LI ; Aijun ZHANG ; Fei XUE ; Yingying XIE ; Yongqiang LIN
China Pharmacy 2026;37(13):1704-1709
OBJECTIVE To establish a quality control method for Jinbei oral liquid based on multi-wavelength switching high performance liquid chromatography (HPLC) fingerprint, chemical pattern recognition and multi-index content determination. METHODS A total of 15 batches of Jinbei oral liquid were used as test samples. The Similarity Evaluation System for Chromatographic Fingerprint of Traditional Chinese Medicine ( Version 2012 ) was adopted to establish multi-wavelength switching HPLC fingerprints, followed by chromatographic peak identification and similarity evaluation. Cluster analysis, principal component analysis and orthogonal partial least squares-discriminant analysis were applied to conduct chemical pattern recognition on the 15 batches of samples. The multi-wavelength switching HPLC method was used to simultaneously determine the contents of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, forsythoside A, baicalin, salvianoli c acid B and wogonoside in samples. RESULTS A total of 25 common peaks were calibrated in the fingerprints of 15 batches of Jinbei oral liquid, among which 7 common peaks were unambiguously identified. The similarity of all samples was higher than 0.960. Chemical pattern recognition results showed that samples S1-S8 were clustered into group 1, and samples S9-S15 were clustered into group 2. Baicalin, wogonoside, neochlorogenic acid, chlorogenic acid and salvianolic acid B were identified as the differential quality markers. The average contents of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, forsythoside A, baicalin, salvianolic acid B and wogonoside in 15 batches of Jinbei oral liquid were 0.213 7, 0.085 3, 0.104 9, 0.287 3, 0.420 1, 0.062 1, 0.176 0 mg/mL, respectively. CONCLUSIONS The established quality control method for Jinbei oral liquid combining multi-wavelength switching HPLC fingerprint, chemical pattern recognition and multi-index content determination is stable and reliable, which can provide a reference for the formulation of quality standards of this preparation.
5.The Chinese version of Chronic Illness Rejection and Discrimination Scale: reliability and validity in maintenance hemodialysis patients
Yingjia XU ; Wei HE ; Songhong XIE ; Mingya LI ; Fei HUANG
Sichuan Mental Health 2025;38(1):78-83
BackgroundPerceived discrimination has been identified as a main risk factor for depression in maintenance hemodialysis patients. Chronic Illness Rejection and Discrimination Scale (CIRDS) is a measure for assessing perceived discrimination in individuals with chronic disease. However, the Chinese version of CIRDS for maintenance hemodialysis patients has not yet been established. ObjectiveTo translate CIRDS into Chinese version and evaluate its reliability and validity in maintenance hemodialysis patients, so as to provide an effective tool for assessing the perceived discrimination among maintenance hemodialysis patients. MethodsThe Brislin's model for translation, back-translation, cross-cultural adaptation and pre-experimentation was utilized to develop a Chinese version of CIRDS. A coherent of 250 maintenance hemodialysis patients attending Taihe Hospital Affiliated to Hubei Medical College, from July to October 2023 were selected as the research subjects. The formal scale was refined by employing item analysis, exploratory factor analysis and confirmatory factor analysis. The validity of the scale was evaluated using content validity and construct validity. The reliability of the scale was evaluated using Cronbach's α coefficient, test-retest reliability and split-half reliability. ResultsThe Chinese version of CIRDS consisted of 11 items, including 2 factors (perceived discrimination and perceived rejection). The scale-level content validity index (S-CVI) value was 0.898 and the item-level content validity index (I-CVI) values ranged from 0.875 to 1.000. Two common factors were extracted by exploratory factor analysis and explained 65.41% of the total variance. Confirmatory factor analysis also indicated that the model provided a good fit for the data. The Cronbach's α coefficient of the scale was 0.910, with Cronbach's α coefficients of 0.835 and 0.912 for the perceived discrimination and perceived rejection, respectively. The split-half reliability of the scale was 0.803, and the test-retest reliability was 0.920. ConclusionThe Chinese version of CIRDS has excellent reliability and validity, which can be used to evaluate the perceived discrimination in maintenance hemodialysis patients.
6.Application of empathy technique in patients with first benign paroxysmal positional vertigo
Cailian FEI ; Juan XIE ; Jingyi ZHANG ; Yu WANG ; Fei LI
Chinese Journal of Clinical Medicine 2025;32(2):188-194
Objective To explore the effects of empathy technology on emotion regulation, sleep improvement and quality of life improvement in patients with first benign paroxysmal positional vertigo (BPPV). Methods A total of 100 patients with the first BPPV in The Second Affiliated Hospital of Naval Medical University from December 2023 to November 2024 were selected, and were divided into control group and observation group by random number table method. The patients in both groups received routine reduction treatment and outpatient follow-up every 3 months after discharge, with a total of 4 follow-up visits. The patients in control group received routine health and psychological education; on this basis, the patients in observation group received empathy technique intervention before, during, after reposition and during follow-up. The emotion, sleep and quality of life scales were evaluated before intervention and at the 4th outpatient follow-up. The recurrence rates of BPPV within 1 year after discharge were compared between the two groups. Results One year after discharge, self-rating anxiety scale (SAS), self-rating depression scale (SDS), symptom checklist 90 (SCL-90) and Pittsburgh sleep quality index (PSQI) scores in the observation group were lower than those in the control group, and multi-dimensional quality of life scores in the observation group was higher than that in the control group. These differences were statistically significant (P<0.05). The recurrence rate of BPPV in the observation group was lower than that in the control group 1 year after discharge (P<0.05). Conclusions Empathy technology intervention can further improve emotion, sleep quality, and quality of life, but reduce disease recurrence rate in first BPPV patients receiving routine treatment and health education, so it can be widely used in clinical practice.
7.Prognostic value of quantitative flow ratio measured immediately after percutaneous coronary intervention for chronic total occlusion.
Zheng QIAO ; Zhang-Yu LIN ; Qian-Qian LIU ; Rui ZHANG ; Chang-Dong GUAN ; Sheng YUAN ; Tong-Qiang ZOU ; Xiao-Hui BIAN ; Li-Hua XIE ; Cheng-Gang ZHU ; Hao-Yu WANG ; Guo-Feng GAO ; Ke-Fei DOU
Journal of Geriatric Cardiology 2025;22(4):433-442
BACKGROUND:
The clinical impact of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) in patients treated with PCI for chronic total occlusion (CTO) was still undetermined.
METHODS:
All CTO vessels treated with successful anatomical PCI in patients from PANDA III trial were retrospectively measured for post-PCI QFR. The primary outcome was 2-year vessel-oriented composite endpoints (VOCEs, composite of target vessel-related cardiac death, target vessel-related myocardial infarction, and ischemia-driven target vessel revascularization). Receiver operator characteristic curve analysis was conducted to identify optimal cutoff value of post-PCI QFR for predicting the 2-year VOCEs, and all vessels were stratified by this optimal cutoff value. Cox proportional hazards models were employed to calculate the hazard ratio (HR) with 95% CI.
RESULTS:
Among 428 CTO vessels treated with PCI, 353 vessels (82.5%) were analyzable for post-PCI QFR. 31 VOCEs (8.7%) occurred at 2 years. Mean value of post-PCI QFR was 0.92 ± 0.13. Receiver operator characteristic curve analysis shown the optimal cutoff value of post-PCI QFR for predicting 2-year VOCEs was 0.91. The incidence of 2-year VOCEs in the vessel with post-PCI QFR < 0.91 (n = 91) was significantly higher compared with the vessels with post-PCI QFR ≥ 0.91 (n = 262) (22.0% vs. 4.2%, HR = 4.98, 95% CI: 2.32-10.70).
CONCLUSIONS
Higher post-PCI QFR values were associated with improved prognosis in the PCI practice for coronary CTO. Achieving functionally optimal PCI results (post-PCI QFR value ≥ 0.91) tends to get better prognosis for patients with CTO lesions.
8.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
9.Erratum: Author correction to "PRMT6 promotes tumorigenicity and cisplatin response of lung cancer through triggering 6PGD/ENO1 mediated cell metabolism" Acta Pharm Sin B 13 (2023) 157-173.
Mingming SUN ; Leilei LI ; Yujia NIU ; Yingzhi WANG ; Qi YAN ; Fei XIE ; Yaya QIAO ; Jiaqi SONG ; Huanran SUN ; Zhen LI ; Sizhen LAI ; Hongkai CHANG ; Han ZHANG ; Jiyan WANG ; Chenxin YANG ; Huifang ZHAO ; Junzhen TAN ; Yanping LI ; Shuangping LIU ; Bin LU ; Min LIU ; Guangyao KONG ; Yujun ZHAO ; Chunze ZHANG ; Shu-Hai LIN ; Cheng LUO ; Shuai ZHANG ; Changliang SHAN
Acta Pharmaceutica Sinica B 2025;15(4):2297-2299
[This corrects the article DOI: 10.1016/j.apsb.2022.05.019.].
10.Submicron-sized superantigen biomimetic liposomes with highly efficient pulmonary accumulation to remodel local immune microenvironment for cancer chemoimmunotherapy.
Bochuan YUAN ; Feng ZHANG ; Qiucheng YAN ; Wanmei WANG ; Zhangyu LI ; Lina DU ; Yiguang JIN ; Fei XIE
Acta Pharmaceutica Sinica B 2025;15(6):2900-2914
Metastatic lung cancer continues to cause a high number of deaths due to high malignancy and poor prognosis, and the efficacy of typical chemotherapy or immunotherapy is less than ideal due to the low pulmonary accumulation and targeting of therapeutics. Here, a submicron-sized biomimetic liposome was formulated for the lung-targeted co-delivery of bacterial superantigen and paclitaxel. Recombinant staphylococcal enterotoxin C2 (rSEC2), a bacterial superantigen, was expressed with the Escherichia coli system and showed potent immunostimulatory activities to mediate tumor cell death. The submicron-sized (∼800 nm) biomimetic liposomes, namely 4T1 cell membrane-hybrid rSEC2 paclitaxel liposomes (TSPLs), exhibited high lung-accumulation efficiency and tumor homologous effect due to the suitable particle size and membrane hybridization of cancer cell membranes with phospholipids. Intravenous TSPLs remarkably inhibited metastatic lung cancer with limited systemic immune responses. TSPLs reversed the immunosuppressive state and increased the proportion of local CD4+ and CD8+ T cells in the lung; moreover, paclitaxel increased tumor cell apoptosis and reduced tumor burden. In summary, the high lung cancer targeting was achieved by particle size control and cell membrane hybridization, and the highly efficient anticancer effect was achieved by the co-delivery of superantigens and chemotherapeutic drugs.

Result Analysis
Print
Save
E-mail