1.Research on Electrical Impedance and Microwave Dual-modality Tomography Algorithm Based on Conditional Diffusion Models
Jin-Zhen LIU ; Xiang-Qian MENG ; Hui XIONG ; Li-Min ZHOU ; Chun-Chan LI
Progress in Biochemistry and Biophysics 2026;53(6):1780-1792
ObjectiveStroke poses a heavy burden due to its high mortality and morbidity rates. Accurate and real-time detection of lesions is pivotal for prompt clinical intervention and favorable prognosis. Electrical impedance tomography (EIT) and microwave tomography (MWT) have emerged as compelling alternatives for stroke screening, owing to their non-ionizing, non-invasive and portable nature. EIT provides information on tissue conductivity, and MWT offers high sensitivity to changes in dielectric properties. However, single-modality imaging is inherently limited, EIT suffers from low sensitivity to deep-seated tissues and severe ill-posedness of inverse problems, whereas MWT is challenged by strong nonlinearity in inverse scattering and susceptibility to modeling errors. Consequently, the clinical utility of standalone EIT or MWT for stroke diagnosis remains constrained by poor spatial resolution and imaging artifacts. To improve the accuracy and robustness of stroke imaging, a dual-modality fusion conditional denoising diffusion probabilistic model (DM-DDPM) was proposed for high-precision dual-modality image reconstruction. MethodsA dual-encoder network with a symmetric architecture and independently trained parameters was constructed to extract heterogeneous features separately from EIT boundary voltage measurements and MWT scattered field signals. Attentional feature fusion (AFF) is employed to integrate complementary information from the two modalities adaptively, generating robust fused priors that suppress redundant noise while preserving key physical characteristics. Subsequently, the fused priors are embedded into a Transformer-based diffusion model via a cross attention mechanism to guide the reverse denoising process. This approach effectively reduces artifacts and enhances the stability of conductivity distribution reconstruction. Time step embedding is introduced to enable the network to perceive the diffusion stage and further improve the accuracy of noise prediction. ResultsSimulated experiments demonstrated that DM-DDPM significantly outperforms single-modality and multi-modality networks under various noise levels. A head model simulation dataset was constructed based on COMSOL Multiphysics, and tests were carried out under 50 dB, 40 dB and 30 dB signal-to-noise ratio levels. At 30 dB, the average relative error (RE) was below 0.20, while the structural similarity index measure (SSIM) and correlation coefficient (CC) remained above 0.90 and 0.89, respectively. Compared with single-modality and multi-modality networks, artifacts were significantly reduced, lesion edges were clearer, and localization was more accurate. The model maintains high reconstruction quality and strong robustness for single, double, and triple lesions simultaneously. Furthermore, physical experiments were conducted using a 16-electrode EIT system and a 16-antenna MWT system with asynchronous data acquisition. These experiments confirmed the feasibility of the method in real-world scenarios and demonstrated that it can robustly reconstruct simulated lesions despite environmental interference and measurement noise, validating its reliability for practical clinical applications. ConclusionThe proposed method effectively combines complementary dual-modality information with a conditional diffusion model. Low accuracy and poor noise resistance in single-modality imaging were effectively addressed, while the noise amplification issue caused by direct multimodal data fusion was avoided. The proposed algorithm exhibits strong anti-noise interference ability and high imaging stability in both simulation and physical experiments. Precise localization of stroke lesions with different quantities was achieved, providing a high-precision, and practical technical support for clinical stroke detection.
2.Herbal Textual Research on Spatholobi Caulis in Famous Classical Formulas
Yajie XIANG ; Yangyang LIU ; Jian FENG ; Chun YAO ; Erwei HAO ; Wenlan LI ; Zhilai ZHAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):238-248
Through consulting herbal medicine, medical books, and local chronicles from past dynasties to modern times, this paper systematically researched Spatholobi Caulis from name, origin, producing areas, harvesting, processing, usage, quality evaluation, functions and indications, providing a reference for the development and utilization of famous classical formulas containing Spatholobi Caulis. According to the research, Spatholobi Caulis was first recorded in the Annals of Shunning Prefecture from the Qing dynasty. It was originally a medicinal herb commonly used in Shunning, Yunnan, and was named from the red juice resembling chicken blood that flowed out after the vein was cut off. The mainstream original plants of each dynasty were Kadsura heteroclita and Spatholobus suberectus. Among them, K. heteroclita mainly focused on dispersing blood stasis and unblocking meridians, mainly treating rheumatic pain and injuries caused by falls or blows, and it is mostly used as the raw material of Jixueteng ointments. S. suberectus was commonly used as decoction pieces in decoction, which had the functions of promoting blood circulation and replenishing blood, activating meridians and collaterals, and mainly used for treating anemia, irregular menstruation, and rheumatic bone pain. The production area of Spatholobi Caulis recorded in the Qing dynasty was Yunnan. Currently, the main production area of S. suberectus is Guangxi, while the main production area of K. interior is Yunnan. In the Qing dynasty, the usage of Spatholobi Caulis was an individual prescription with other herbs before making ointments, which was usually composed of the juice of it, safflower, angelica, and glutinous rice. But in modern times, Spatholobi Caulis is mostly sliced and dried for use. The quality of Spatholobi Caulis is often determined by the number of reddish-brown concentric circles on the cut surface, with a higher number indicating better quality. Additionally, the presence of resinous secretions is also considered desirable. Based on the research findings, it is suggested that when developing famous classical formulas containing Spatholobi Caulis, the choice of the primary source should be S. suberectus or K. heteroclita, taking into consideration the therapeutic effects of the formula. It is also recommended that the latest plant classification be referenced in the next edition of Chinese Pharmacopoeia, adjusting the primary source of Kadsurae Caulis to K. heteroclita to avoid confusion caused by inconsistent original names, and the functions adjust to promote Qi circulation and relieve pain, disperse blood stasis and unblock collaterals, treating injuries caused by falls and bruises.
3.Relationship between peer victimization and depressive symptoms among secondary vocational health school students: the chain mediating role of positive mental health and social media addiction
Houyi LI ; Chun XU ; Shasha HU ; Bo XIANG ; Kezhi LIU
Sichuan Mental Health 2025;38(2):159-165
BackgroundStudents in secondary vocational health school are at the age of puberty and prone to depressive symptoms. Peer victimization and social media addiction are found to be crucial in influencing the development of depression, and positive mental health has been proven to alleviate depressive symptoms, whereas there remains a striking lack of research on the mediating role of positive mental health and social media addiction in the relationship between peer victimization and depressive symptoms among secondary vocational health school students. ObjectiveTo explore the relationship between peer victimization and depressive symptoms and investigate the mediating role of positive mental health and social media addiction, so as to provide references for the prevention of depression among secondary vocational health school students. MethodsFrom October to December 2020, a cluster sampling framework was utilized to recruit 7 307 students from a secondary vocational health school in Luzhou City, Sichuan Province. Assessments were performed using Multidimensional Peer Victimization Scale (MPVS), Warwick-Edinburgh Mental Well-being Scale (WEMWBS), Bergen Social Media Addiction Scale (BSMAS) and Patient Health Questionnaire Depression Scale-9 item (PHQ-9). Spearman correlation analysis was calculated to determine correlations between scores of scales, Process 4.0 was employed to test the mediation effect, and the bias-corrected Bootstrap procedure was used to test the significance of the mediation effect. ResultsA total of 7 044 (96.40%) valid questionnaires were collected. And 4 391(62.34%)students were found to have depressive symptoms. Correlation analysis revealed that PHQ-9 score was positively correlated with BSMAS score and MPVS score (r=0.404, 0.506, P<0.01). WEMWBS score was negatively correlated with PHQ-9 score, BSMAS score and MPVS score (r=-0.587, -0.259, -0.358, P<0.01). BSMAS score was positively correlated with MPVS score (r=0.328, P<0.01). Positive mental health played a mediating role in the relationship between peer victimization and depressive symptoms, with an indirect effect value of 0.130 (95% CI: 0.119~0.141), accounting for 30.81% of the total effect. Social media addiction also mediated the relationship between peer victimization and depressive symptoms, with an indirect effect value of 0.052 (95% CI: 0.045~0.059), accounting for 12.34% of the total effect. Positive mental health and social media addiction exhibited a chained mediation effect on the relationship between peer victimization and depressive symptoms, with an indirect effect value of 0.012 (95% CI: 0.010~0.014) and accounting for 2.84% of the total effect. ConclusionPeer victimization can affect the presence of depressive symptoms among secondary vocational health school students both directly and indirectly through either separate or chained mediation of positive mental health and social media addiction.
4.Structural and Spatial Analysis of The Recognition Relationship Between Influenza A Virus Neuraminidase Antigenic Epitopes and Antibodies
Zheng ZHU ; Zheng-Shan CHEN ; Guan-Ying ZHANG ; Ting FANG ; Pu FAN ; Lei BI ; Yue CUI ; Ze-Ya LI ; Chun-Yi SU ; Xiang-Yang CHI ; Chang-Ming YU
Progress in Biochemistry and Biophysics 2025;52(4):957-969
ObjectiveThis study leverages structural data from antigen-antibody complexes of the influenza A virus neuraminidase (NA) protein to investigate the spatial recognition relationship between the antigenic epitopes and antibody paratopes. MethodsStructural data on NA protein antigen-antibody complexes were comprehensively collected from the SAbDab database, and processed to obtain the amino acid sequences and spatial distribution information on antigenic epitopes and corresponding antibody paratopes. Statistical analysis was conducted on the antibody sequences, frequency of use of genes, amino acid preferences, and the lengths of complementarity determining regions (CDR). Epitope hotspots for antibody binding were analyzed, and the spatial structural similarity of antibody paratopes was calculated and subjected to clustering, which allowed for a comprehensively exploration of the spatial recognition relationship between antigenic epitopes and antibodies. The specificity of antibodies targeting different antigenic epitope clusters was further validated through bio-layer interferometry (BLI) experiments. ResultsThe collected data revealed that the antigen-antibody complex structure data of influenza A virus NA protein in SAbDab database were mainly from H3N2, H7N9 and H1N1 subtypes. The hotspot regions of antigen epitopes were primarily located around the catalytic active site. The antibodies used for structural analysis were primarily derived from human and murine sources. Among murine antibodies, the most frequently used V-J gene combination was IGHV1-12*01/IGHJ2*01, while for human antibodies, the most common combination was IGHV1-69*01/IGHJ6*01. There were significant differences in the lengths and usage preferences of heavy chain CDR amino acids between antibodies that bind within the catalytic active site and those that bind to regions outside the catalytic active site. The results revealed that structurally similar antibodies could recognize the same epitopes, indicating a specific spatial recognition between antibody and antigen epitopes. Structural overlap in the binding regions was observed for antibodies with similar paratope structures, and the competitive binding of these antibodies to the epitope was confirmed through BLI experiments. ConclusionThe antigen epitopes of NA protein mainly ditributed around the catalytic active site and its surrounding loops. Spatial complementarity and electrostatic interactions play crucial roles in the recognition and binding of antibodies to antigenic epitopes in the catalytic region. There existed a spatial recognition relationship between antigens and antibodies that was independent of the uniqueness of antibody sequences, which means that antibodies with different sequences could potentially form similar local spatial structures and recognize the same epitopes.
5.Correlation between iodine level in drinking water and conventional water quality indicators
Xiaoxue SHI ; Demei ZHOU ; Chun XIE ; Hongbing YE ; Yang LI ; Xuan LI ; Gang CHEN ; Mengjie YANG ; Hong XIANG
Chinese Journal of Endemiology 2025;44(7):558-562
Objective:To study the correlation between iodine level in drinking water and conventional water quality indicators.Methods:From June 2017 to July 2018, a simple random sampling method was used to select administrative villages (communities) from 88 counties (cities, districts) in Guizhou Province with a sampling size greater than 5%. One drinking water sample was collected from each administrative village (community), and conventional water quality indicators (including fluorine, aluminum, mercury, selenium, sulfate, total dissolved solids and total hardness) were tested in accordance with the methods outlined in the "Standards for Drinking Water Quality" (GB 5749-2006). The cerium sulfate catalytic spectrophotometric method was employed to test drinking water iodine level. Spearman method was utilized to analyze the correlation between iodine level in drinking water and conventional water quality indicators.Results:A total of 904 drinking water samples were tested, with a median iodine level of 1.90 μg/L and a range of 0.10 - 36.70 μg/L. There were 899 administrative villages (communities) with a water iodine level of less than 10 μg/L, accounting for 99.45%. There were only 5 administrative villages (communities) with a water iodine level of greater than 10 μg/L, accounting for 0.55%. Correlation analysis revealed that in Guizhou Province, the iodine level in drinking water was positively correlated with the levels of fluorine, aluminum, sulfate, total dissolved solids, and total hardness [correlation coefficients ( r) = 0.11, 0.07, 0.07, 0.08, 0.07, P < 0.05], and was a negatively correlated with mercury and selenium levels ( r = - 0.12, - 0.12, P < 0.001). Conclusions:External environment in Guizhou Province is generally deficient in iodine. The iodine level in drinking water is positively correlated with the levels of fluorine, aluminum, sulfate, total dissolved solids, and total hardness, and negatively correlated with the levels of mercury and selenium.
6.Influence of Trigeminal Rod Therapy on the Stone Expulsion Effect after Extracorporeal Shock Wave Lithotripsy in Patients with Ureteral Calculi
Xiao-ning HUANG ; Li-hua CAO ; Chun-xiang XIE
Progress in Modern Biomedicine 2025;25(18):2911-2916
Objective:To observe the influence of trigeminal rod therapy on the stone expulsion effect after extracorporeal shock wave lithotripsy(ESWL)in patients with ureteral calculi.Methods:The clinical data of patients with ureteral calculi admitted to Weifang Traditional Chinese Medicine Hospital from May 2022 to August 2024 were retrospectively analyzed.Among them,50 patients who received ESWL ESWL combined with trigeminal rod therapy were the observation group,and 50 patients who received ESWL single treatment were randomly selected as the case control group according to the ratio of 1:1.The clinical efficacy,stone expulsion time,usage rate of analgesic drugs,incidence of renal colic and pain degree of the two groups were compared.Results:Compared with control group,the total clinical effective rate in the observation group was higher,the incidence of renal colic and usage rate of analgesic drugs were lower,and the stone expulsion time was shorter(P<0.05).Compared with control group at 1 d,3 d and 7 d after treatment,the visual analogue scale(VAS)in the observation group was lower(P<0.05).Conclusion:Trigeminal rod therapy can increase the total clinical effective rate after ESWL in patients with ureteral calculi,shorten the stone excretion time,reduce usage rate of analgesic drug and the risk of renal colic,and alleviate pain.
7.Clinical distribution and diagnostic value of anti-total phospholipid antibodies in patients with antiphospholipid syndrome
Xiaohong XIANG ; Qingmeng CAI ; Xiangjun LIU ; Zelin YUN ; Ru LI ; Rulin JIA ; Chun LI
Chinese Journal of Rheumatology 2025;29(4):280-285
Objective:To investigate the clinical distribution and diagnostic value of anti-total phospholipid-antibodies(aTPL) patients with in antiphospholipid syndrome(APS).Methods:We collected the clinical data and laboratory test results of patients diagnosed with APS, systemic lupus erythematosus, Sj?gren′s syndrome, osteoarthritis, rheumatoid arthritis, ankylosing spondylitis, mixed connective tissue disease, and adult Still′s disease in Peking University People′s Hospital from February 2009 to October 2017. A total of 335 cases were studied, of which 163 were APS patients, 122 were disease control(DC) and 50 were health control(HC). Enzyme-linked immunosorbent assay(ELISA) was used to measure aTPL, anti-cardiolipin antibody (aCL), and anti-beta-2-glycoprotein Ⅰ antibody (aβ 2GPⅠ). The Chi-square test was used to compare the differences between groups. Results:The prevalence of aTPL in APS, DC and HC were 39.9%, 3.3%and 2.0% respectively. The sensitivity and specificity were 39.9%, 97.1%. The proportion of thrombosis[75.4%(49/65) vs. 51.0%(50/98), χ2=9.73, P=0.002] and arterial thrombosis[49.2%(32/65) vs. 25.5%(25/98), χ2=9.67, P=0.002] was significantly higher in the aTPL positive group than that of the negative group. In aTPL positive group, the positive rate of aCL[84.6%(55/65) vs.29.6%(29/98), χ2=47.37, P<0.001], aβ 2GPⅠ[83.1%(54/65) vs.37.8%(37/98), χ2=32.55, P<0.001] and LA[61.5%(40/65) vs. 42.9%(42/98), χ2=5.46, P=0.020] was significantly higher than that of negative group.The area under ROC curve (95% CI) of aTPL [0.694(0.636, 0.751)] was slightly higher than that of aCL [0.668(0.610, 0.726)], but lower than that of aβ 2GPⅠ [0.746(0.694, 0.799)]. Conclusion:aTPL exhibits a strong correlation with thrombosis in patients with APS, particularly arterial thrombosis, and demonstrates high specificity, which can assist in the diagnosis of seronegative APS.
8.The current status and its related factors of vascular access team building in hemodialysis centers in China
Yao LIU ; Jing LI ; Liyun CAO ; Qizhuang JIN ; Xizi ZHENG ; Xiufang DUAN ; Chun LI ; Jing XIANG ; Mo SU ; Zhiwen WANG
Chinese Journal of Nephrology 2025;41(2):90-98
Objective:To investigate the current status of vascular access team building and analysis its related factors in hemodialysis centers in China.Methods:The study was a cross-sectional survey. Using a convenience sampling method, a questionnaire was designed to investigate the clinical practice of vascular access teams in 527 hemodialysis centers in China from March to April 2022. The related factors of the formation of vascular access teams and the setting up of vascular access coordinators (VAC) were analyzed by multivariate logistic regression method.Results:A total of 506 valid questionnaires were recovered, with a recovery rate of 96.02%. There were 247 (48.81%) and 193 (38.14%) hemodialysis centers respectively across China that had built vascular access teams and set up VAC. Hemodialysis centers with more than 10 years of practice had higher rate of implementation than those in hemodialysis centers with practice years less or equal than 10 years in developing standardized procedures for vascular access management ( χ 2=8.288, P=0.004), holding continuous quality improvement meetings on vascular access ( χ 2=8.210, P=0.004), establishing vascular access teams ( χ 2=33.805, P<0.001) and setting up vascular access coordinators ( χ 2=16.038, P<0.001), and the difference was statistically significant. The results of multivariate logistic regression analysis showed that the number of dialysis machines ( OR=2.221, 95% CI 1.118-4.415, P=0.023), the number of patients on dialysis( OR=2.946, 95% CI 1.375-6.310, P=0.005), and the establishment of VAC positions ( OR=9.463, 95% CI 5.307-16.874, P<0.001), and the standardized vascular access management process ( OR=3.383, 95% CI 2.012-5.687, P<0.001) were the related factors of vascular access team building. The related factors of setting up a VAC position in hemodialysis center were opening vascular access clinic ( OR=2.704,95% CI 1.382-5.290, P=0.004), the formation of a vascular access team ( OR=9.464, 95% CI 5.312-16.860, P<0.001), and constructing standardized procedures for vascular access management ( OR=3.663, 95% CI 2.243-5.982, P<0.001). Conclusion:The implementation rates of vascular access team and VAC position in hemodialysis centers were 48.81% and 38.14%, respectively. The number of dialysis machines, the number of patients on dialysis, the standardized procedures for vascular access management, the vascular access clinic, the vascular access team, and the VAC position were the relevant factors of the team building for vascular access.
9.Design of new type of elastic gloves for burn scar rehabilitation
Ting SHEN ; Hai-yang ZHAO ; Xiao-chun JIAO ; Bao-li CHEN ; Zhi-juan WANG ; Li-na WANG ; Xiang-yang ZHAO ; Qin ZHOU
Chinese Medical Equipment Journal 2025;46(8):118-120
Objective To design a new type of elastic gloves for burn scar rehabilitation to solve the problems of conventional elastic gloves in pressure distribution,elasticity maintenance and absorption of sweat stains.Methods The new elastic gloves was made of non-woven fabric by spandex material,which was composed of external and internal parts.The main body of the external part was used as the primary structure of the gloves,which was provided with a sealing strip,a storage bag,a drawstring,etc.The internal part consisted of a bonding sheet,an elastic band,a fiber sheet,an absorbent sponge,some breathable holes,etc.Results The new elastic gloves designed could be used for the pressure therapy for the scars on the opisthenar,palm side,finger web and purlicue with scar proliferation inhibitted effectively,and the breathable hole and absorbent sponge contributed to the absorption of the sweat of the patient.Conclusion The new type of elastic gloves gains advantages in elasticity,wearing comfort and effectiveness of the pressure therapy for purlicue and finger web,and can be used for the pressure therapy to inhibit proliferative scarring after burns.[Chinese Medical Equipment Journal,2025,46(8):118-120]
10.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]

Result Analysis
Print
Save
E-mail