1.Determination of Dilauryl Thiodipropionate in Fried Foods by Reverse Phase Liquid Chromatography-Tandem Mass Spectrometry
Jin-Can SHEN ; Yao LUO ; Feng-Qi WU ; Bei-Bei XIONG ; Zhang-Jie WU ; Ya-Mei LI ; Jun-Fa ZENG ; Chang-Xiong HUANG
Chinese Journal of Analytical Chemistry 2025;53(11):1860-1869
A method was developed for determination of dilauryl thiodipropionate(DLTDP)in fried foods by coupling solid-phase extraction(SPE)pretreatment with reverse-phase liquid chromatography-tandem mass spectrometry(RPLC-MS/MS)detection.Samples were extracted with n-hexane as the solvent,purified using a neutral alumina SPE cartridge,and finally analyzed by RPLC-MS/MS.Quantitative analysis was performed using matrix-matched calibration curves combined with an external standard method under optimal experimental conditions.The results showed that DLTDP exhibited good linearity in the range of 2.0-50.0 μg/L,with a correlation coefficient(R2)≥0.999.The limit of detection(LOD)and the limit of quantification(LOQ)of the method were 0.15 mg/kg and 0.5 mg/kg,respectively.The mean recoveries at three fortification levels(0.5,1.0,and 200 mg/kg)in different samples ranged from 84.8%to 96.8%,with the relative standard deviations(RSDs)all less than 8.0%.The developed method was highly sensitive,accurate and reliable,and easy to operate,making it well suited for the routine quantitative analysis of DLTDP in fried foods.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Research and application of a new deep learning based strategy for platelet histogram review
Enming ZHANG ; Chao YANG ; Xianchun CHEN ; Yan LIN ; Taixue AN ; Haixia LI ; Yongjian HE ; Zhiwei LIU ; Limei FENG ; Wanying LIN ; Tie XIONG ; Kai QIU ; Ya GAO ; Lizhu HUANG ; Jing HE ; Chunyan WANG ; Dehua SUN ; Bo SITU ; Lei ZHENG
Chinese Journal of Laboratory Medicine 2025;48(9):1201-1206
Objective:To develop an artificial intelligence (AI)-based platelet review strategy to identify abnormal platelet histograms with no significant difference between initial impedance platelet count (PLT-I) and PLT-F results.Methods:This study included 5 119 routine blood analysis in Nanfang Hospital of Southern Medical University and its Ganzhou branch from July 2023 and March 2024. Specimens exhibiting abnormal platelet histograms and an initial platelet count >40×10?/L underwent review using the fluorescent platelet count (PLT-F) channel. Consistency of the results was defined as a difference between impedance platelet count (PLT-I) and PLT-F less than ±20% of the PLT-F results. A deep learning model was developed using platelet and red blood cell histogram data from a training set of 3 807 specimens. The model′s diagnostic performance was evaluated on an independent external validation set ( n=805) using receiver operating characteristic (ROC) curve analysis. Changes in the number of reviewed samples and sample turnaround time were analyzed to assess its clinical utility. Results:The deep learning model based on platelet and red blood cell histograms achieved an area under the ROC curve (AUC) of 0.854 in the training set. At a cutoff value of 0.1, the sensitivity was 0.954 and specificity was 0.358. The model could reduce review by 16.80% (190/1 131). In the validation set, the AUC was 0.805, with a sensitivity of 0.955 and specificity of 0.307, corresponding to a reduction of 17.41% (47/270) in reviewed specimens.Conclusion:The platelet review prediction model developed based on deep learning technology can efficiently identify samples with consistent results before and after review, reducing unnecessary reviews and shortening specimen testing time, thereby improving the efficiency of platelet test.
8.Clinical efficacy of Wenshen Chushi Decoction combined with LIPUS on erectile dysfunction with renal deficiency and phlegm-dampness syndrome
Wen-xiong ZHU ; Yi-feng YUAN ; Tao LIU ; Bo LI ; Liu-ya LONG ; Qi-hua CHEN ; Ju-qiao HE
National Journal of Andrology 2025;31(6):519-525
Objective:To explore the clinical efficacy of Wenshen Chushi Decoction combined with low intensity pulsed ultra-sound(LIPUS)on erectile dysfunction(ED)caused by renal deficiency and phlegm-dampness syndrome.Methods:One hundred and twenty ED patients were included from the Department of Andrology in the First Hospital of Hunan University of Traditional Chinese Medicine.The patients in control group were treated with Wenshen Chushi Decoction.While the patients in observation group were trea-ted with Wenshen Chushi Decoction combined with LIPUS for 8 consecutive weeks.After the treatment,the efficacy was evaluated using the International Index of Erectile Function-5(IIEF-5)score,Penile Flow Index(PFI),Traditional Chinese Medicine Syndrome Score,Self-Rating Depression Scale(SDS)score,and Self-Rating Anxiety Scale(SAS)score.Safety was also observed.And the ef-ficacy was followed up 4 weeks after the end of treatment.Results:Fifty-seven cases were enrolled into control group finally with 55 cases in the treatment group.After the treatment,all the patients in both of groups showed an improvement in IIEF-5 scores(P<0.01).Compared with the control group(19.09±2.22),the IIEF-5 score in observation group(20.42±2.39)increased signifi-cantly(P<0.01).After the treatment,the scores of PFI,TCM syndrome and SDS in both groups decreased(P<0.01,P<0.05,P<0.01).Compared with the control group([3.77±1.21],[9.91±1.71]and[39.88±2.63]points),the observation group([2.92±1.08],[4.78±1.45],and[34.51±2.09]points)showed a more significant decrease(P<0.01).There was no significant difference in total effective rate between the two groups(P>0.05).During follow-up,the IIEF-5 scores of both groups of patients were higher than those before(P<0.05,P<0.01),and the observation group score was higher than that in the control group([17.15±3.37]vs[13.63±1.96],P<0.01).No adverse reaction and abnormality of indicators occurred in both of two groups.Conclusion:Wenshen Chushi Decoction has a significant therapeutic effect on ED caused by renal deficiency and phlegm-dampness syndrome.It can not only improve the quality of erection,but also improve the physical and mental symptoms associated with ED,which makes therapeutic effect lasting longer.
9.Cross-sectional survey of healthcare-associated infection in 5 736 medical institutions across China in 2024
Cui ZENG ; Wuqiang GAO ; Fu QIAO ; Hui ZHAO ; Xu FANG ; Linping LI ; Xiuwen CHEN ; Jiansen CHEN ; Dan LI ; Yuan ZHOU ; Lingli YU ; Qinglan MENG ; Xia MOU ; Lijuan XIONG ; Weiguang LI ; Ding LIU ; Jiaqing XIAO ; Limei OU ; Baozhen LI ; Jun YIN ; Haojun ZHANG ; Qiang FU ; Qun LU ; Biao WU ; Ya-wei XING ; Shumei SUN ; Shuncai WANG ; Longmin DU ; Jingping ZHANG ; Wen-ying HE ; Gui CHENG ; Nan REN ; Xun HUANG ; Anhua WU
Chinese Journal of Infection Control 2025;24(11):1572-1583
Objective To understand the current situation of healthcare-associated infection(HAI)in China,pro-vide data support and decision-making basis for formulating scientific and effective strategies for HAI prevention and control.Methods A nationwide cross-sectional survey on HAI was conducted among various types and levels of medical institutions in China according to a unified protocol of bedside surveys and case investigations.Results In 2024,a total of 5 736 medical institutions and 2 751 765 patients were surveyed.Among them,34 889 HAI cases were identified,with a prevalence rate of 1.27%.The number of HAI episodes was 38 032,and case prevalence rate was 1.38%.The prevalence rate of HAI in medical institutions in different regions of China ranged from 0.66%to 2.35%.Among medical institutions of different scales,those with a bed capacity of ≥900 had the high-est incidence of HAI,reaching 1.65%.The most common infection site was the lower respiratory tract(44.66%),followed by the urinary tract(12.94%),surgical site(9.32%),upper respiratory tract(7.02%),and bloodstream infection(5.78%).The top 3 departments with the highest HAI rates were the general intensive care unit(10.02%),department of neurosurgery(5.51%),and department(group)of hematology(5.34%).A total of 23 238 strains of HAI pathogens were detected,with 10 714 strains(46.10%)from lower respiratory tract speci-mens.The top 5 detected strains were Klebsiella pneumoniae(14.76%),Pseudomonas aeruginosa(13.33%),Escherichia coli(12.79%),Acinetobacter baumannii(9.23%),and Staphylococcus aureus(7.88%).231 944 pa-tients underwent class Ⅰ incision surgery were monitored,with 1 647 cases experienced surgical site infection,and the prevalence rate of surgical site infection was 0.71%.The number of patients who should undergo pathogen de-tection(patients receiving therapeutic and therapeutic combined prophylactic antimicrobial agents)was 715 179,while the actual number was 480 492,with a pathogen detection rate of 67.18%.425 225 patients received patho-genic detection before treatment,with a detection rate of 59.46%.Conclusion The overall HAI prevalence in Chi-na is lower,showing disparities among medical institutions of different regions and scales.Therefore,precise imple-mentation of measures is necessary for HAI prevention and control,with a focus on high-risk institutions and high-risk departments,key areas,and critical procedures.All levels of medical institutions should continuously reduce the incidence of HAI by strengthening monitoring,standardizing the use of antimicrobial agents,and reinforcing basic HAI prevention and control measures.
10.Isolation,identification,and biological characterization of enterotoxigenic Escherichia coli from a South China tiger
Jing-ru XU ; Zhi-hao ZHU ; Yu-qi LI ; Si-si FAN ; Ya-li KANG ; Yu-bin ZHUO ; Ling-shan HUANG ; Shu-qi QIU ; XUE-YUXI ; Xiao-ping WU ; Yu-ting LIAO ; Wei-ye LIN ; Xiao-ziyi XIAO ; Xue-jin LI ; Teng-teng CHEN ; Xi-pan LIN ; Kai-xiong LIN ; Ke-wei FAN
Chinese Journal of Zoonoses 2025;41(6):567-573
This study was aimed at identifying the pathogenic bacteria responsible for the death of a young tiger at the Fujian Meihua Mountain South China Tiger Breeding Research Institute.Tissue samples from the lungs,liver,and intestines of the deceased tiger were collected,and the bacteria were cultured inasterile environment.The bacterial strains were characterized according to their morphological and molecular biological properties,including assessment of virulence genes and antibiotic resistance genes,mouse lethality tests,and antibiotic susceptibility evaluations.A predominant bacterial strain isolated from the liver of the deceased tiger was identified as enterotoxigenic Escherichia coli(ETEC)strain Tiger22513F.Phylogenetic analysis of the 16S rRNA gene revealed that the Tiger22513F strain exhibited close genetic similarity to the reference strain ETEC(MF919609.1),with 99.9%nucleotide similarity,and resided on the same evolutionary branch.The Tiger22513F strain contained 11 antibiotic resistance genes(tetA,sul1,sul3,cmlA,floR,blaTEM,blaSHV,blaCMY-2,qnrA,qnrS,and qnrD)along with five virulence genes(VT1,fyuA,tsh,iucD,and ST).Mouse lethality tests indicated significant pathogenicity toward mice,affecting primarily the lungs,liver,and intestines.Antibiotic susceptibility testing demonstrated that this strain exhibited resistance to various classes of beta-lactam antibiotics,as well as quinolones and aminoglycosides.This investigation successfully isolated a multi-drug resistant enterotoxigenic Escherichia coli strain with pronounced pathogenicity from the liver of a deceased tiger;thus providing valuable scientific insights for clinical diagnosis,as well as prevention and control measures,against ETEC infections in South China tigers.

Result Analysis