1.Improvement effect of metformin on liver injury in non-alcoholic steatohepatitis rats
Shuang WU ; Hailin CHENG ; Dan LIU ; Ting XIAO ; Xingbang WU ; Huadong LI ; Xudong HU
China Pharmacy 2025;36(7):837-842
OBJECTIVE To investigate the effects of metformin (Met) on liver injury in non-alcoholic steatohepatitis (NASH) rats by regulating the PI3K/AKT/PDGF signaling pathway. METHODS NASH model was constructed by feeding rats with a high- glucose and high-fat diet, and assigned into Model group, Met low-dose group (Met-L group, 100 mg/kg), Met medium-dose group (Met-M group, 200 mg/kg), Met high-dose group (Met-H group, 400 mg/kg), and high dose of Met+PI3K activator group (Met-H+740 Y-P group, 400 mg/kg Met+50 mg/kg 740 Y-P), with 12 rats in each group. Another 12 rats were regarded as the Control group. Each group of rats was orally administered/injected with the corresponding medication once a day for 6 consecutive weeks. The changes in body weight and liver index of rats were recorded and analyzed. The pathological damage [evaluation of non-alcoholic fatty liver disease activity score (NAS)], lipid deposition (calculation of the proportion of oil red O-positive staining area), and fibrosis (calculation of collagen deposition score) were observed in liver tissue of rats. The levels of inflammatory factors [interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α)] in serum and liver tissue, the levels of serum lipid metabolism indicators [total cholesterol (TC), triglyceride (TG), and low-density lipoprotein cholesterol (LDL-C)] and liver function indicators [aspartate aminotransferase (AST) and alanine Δ 基金项目 武汉市知识创新专项项目(No.2022020801010588); aminotransferase (ALT)] were measured. The expression levels of PI3K/AKT/PDGF signaling pathway-related proteins and Caspase-3 in liver tissue of rats were determined. RESULTS Compared with the Control group, body weight, liver index, the levels of serum lipid metabolism indicators and liver function indicators, the levels of IL-6 and TNF-α in serum and liver tissue, the NAS, the proportion of oil red O-positive staining area, the collagen deposition fraction, and the levels of phosphorylated PI3K and AKT proteins, as well as the expression levels of PDGF and Caspase-3 proteins in liver tissue, were all significantly increased (P<0.05). The liver tissue showed severe pathological damage, characterized by an abundance of lipid droplets and pronounced collagen deposition. After the intervention with Met, the aforementioned quantitative indicators and pathological changes in rats were significantly improved in a dose- dependent manner (P<0.05). 740 Y-P could reverse the improvement effects of high dose of Met on the above indexes of rats (P< 0.05). CONCLUSIONS Met can improve liver damage, and alleviate inflammatory reactions and liver fibrosis of NASH rats, the mechanism of which may be associated with inhibiting PI3K/AKT/PDGF signaling pathway.
2.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
3.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
4.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
5.Advances in the diagnosis and treatment of hepatocellular carcinoma with bile duct tumor thrombus
Yuxiang GUO ; Maosen WANG ; Zhongyuan LIU ; Xudong ZHANG ; Pengfei MA ; Xiangkun WANG ; Renfeng LI
Journal of Clinical Hepatology 2025;41(2):359-364
Hepatocellular carcinoma (HCC) with biliary duct tumor thrombus (BDTT) is currently not common in clinical practice and is easily misdiagnosed, and previously, it was often considered an advanced stage of the disease with a poor prognosis, making its treatment challenging. However, in-depth studies in recent years have gradually deepened our understanding of this disease, leading to significant changes in diagnostic and treatment concepts. Currently, comprehensive treatment, mainly surgery, is used for treatment, but there is still controversy over the selection of clinical treatment strategies. This article provides a detailed discussion on surgical methods and prognosis, in order to provide a reference for clinical treatment options.
6.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
7.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
8.Influence of Gene Mutation on the Effectiveness of Arsenic-Containing Herbal Compound Formula in Treatment of Myelodysplastic Syndromes of Different TCM Patterns
Zichun WANG ; Zhuo CHEN ; Dexiu WANG ; Haiyan XIAO ; Weiyi LIU ; Ruibai LI ; Chi LIU ; Fengmei WANG ; Shanshan ZHANG ; Mingjing WANG ; Liu LI ; Xiaoqing GUO ; Hongzhi WANG ; Xudong TANG
Journal of Traditional Chinese Medicine 2025;66(14):1463-1472
ObjectiveTo observe the effect of gene mutation on the effectiveness of arsenic-containing Chinese herbal compound formulas in the treatment of myelodysplastic syndromes (MDS) of different traditional Chinese medicine (TCM) patterns, so as to provide the basis for the clinical application. MethodsClinical data of 442 MDS patients who were treated with arsenic-containing herbal compound formulas were retrospectively collected, including the baseline demographic and clinical characteristics of the patients. Based on the TCM four examinations, the patients were divided into the spleen-kidney deficiency group as well as the qi-yin deficiency group, and according to the results of the next-generation sequencing (NGS) test, they were divided into the group with and without gene mutation respectively. The influence of gene mutation on the clinical effectiveness of patients with different TCM patterns was analyzed, the baseline demographic and clinical characteristics of the patients with different outcomes of the two TCM patterns were compared, and multivariate Logistic regression analysis was conducted on the influencing factors of the effective rate of MDS patients with gene mutation. ResultsA total of 190 cases were included in the spleen-kidney deficiency group (119 cases with gene mutation) and 43 cases in the qi-yin deficiency group (23 cases with gene mutation). No statistically significant differences were noted in effectiveness assessment, total effective rate, and total response rate between the spleen-kidney deficiency group and the qi-yin deficiency group (P>0.05). In the spleen-kidney deficiency group, the total effective rate of MDS with gene mutation was 65.55% (78/119), which was lower than 80.28% (57/71) of MDS without gene mutation, with statistical significance (P = 0.033), while no statistical differences in effectiveness assessment and total response rate were noted (P>0.05). In the qi-yin deficiency group, no statistical differences were observed in effectiveness assessment, total effective rate, and total response rate of the patients in with or without gene mutation (P>0.05). In the spleen-kidney deficiency group with gene mutation, the rate of complex karyotype (P = 0.031) and the mutation rate of CBL gene (P = 0.032) in the ineffective population were higher than those in the effective population, while the mutation rate of DDX41 gene in the effective population was higher than that in the ineffective population (P = 0.033). No statistically significant differences were found in other gene mutations, age, gender distribution, number of gene mutations, bone marrow hyperplasia degree, blast cell range, reticular fiber tissue proliferation or not, and prognosis of chromosomal abnormalities between the effective and ineffective populations (P>0.05). In the qi-yin deficiency group with gene mutation, no statistically significant differences were found in various items between populations with different outcomes (P>0.05). Multivariate Logistic regression analysis showed that complex karyotype, CBL mutation, and DDX41 mutation were independently associated with the effective rate of MDS with spleen-kidney deficiency and gene mutation (P<0.05). DDX41 mutation was an independent protective factor in the spleen-kidney deficiency group (OR>1), while complex karyotype and CBL mutation were independent risk factors (OR<1). ConclusionThe arsenic-containing TCM compound formulas exhibited better effectiveness in MDS with spleen-kidney deficiency pattern without mutation; and in MDS with spleen-kidney deficiency pattern without complex karyotypes, CBL mutation, and with DDX41 mutations. Furthermore, DDX41 mutation was an independent protective factor in the spleen-kidney deficiency group, while complex karyotype and CBL mutation were independent risk factors. In MDS with qi-yin deficiency pattern, gene mutation-related factors showed no significant impact on the effectiveness of arsenic-containing TCM compound formulas.
9.Correlation between asthma and nocturia in women: an analysis based on NHANES database from 2005 to 2018
Chunxiao YANG ; Linbo YANG ; Ming LIU ; Yongan WEN ; Xudong LI
Journal of Modern Urology 2025;30(2):118-121
Objective: To analyze the relationship between asthma and nocturia in women based on the National Health and Nutrition Examination Survey (NHANES) database from 2005 to 2018,so as to provide reference for the prevention and treatment of female nocturia. Methods: Female respondents aged ≥20 years with nocturia or asthma were selected from the 2005-2018 NHANES database.Those with both diabetes stroke and obstructive sleep apnea syndrome were excluded.A weighted analysis was conducted using a complex sampling design.The association between asthma and nocturia in women was evaluated with univariate analysis,propensity score matching (PSM),and multivariate logistic regression models. Results: A total of 14 718 respondents were selected,of whom 1426 (9.7%) were diagnosed with asthma,and 4664 (31.7%) with nocturia.There is a significant correlation between asthma and nocturia (χ
=39.846,P<0.01). Age,body mass index (BMI),smoking and race were also associated with nocturia (P<0.01).Multivariate logistic regression analysis showed that,the age,BMI,smoking,race and asthma were correlated with the risk of nocturia,before PSM matching (P<0.05).To eliminate confounding bias,PSM was applied,and generalized linear mixed model analysis after matching showed that the risk of nocturia remained high in asthma patients (OR=1.540,95% CI:1.320-1.800,P<0.01). Conclusion: Asthma is associated with nocturia in women,indicating that it may be an important risk factor for female nocturia.
10.Assessing traditional Chinese medicine from a molecular perspective
Minhui Su ; Wenxi Wang ; Xudong Sun ; Lihong Li ; Weihong Tan
Journal of Traditional Chinese Medical Sciences 2025;2025(1):3-9
Molecular medicine, which delves into the intricacies of biomolecular structure, function, and role, is pivotal for advancing precise diagnostics and personalized treatment. Nucleic acids, a class of star functional molecules, are notable for their versatile applications in molecular diagnostics, gene therapy, and drug development. Therefore, in this study, we review the extensive use of nucleic acid aptamers in medicinal practice. Furthermore, the expanding field of molecular medicine has catalyzed advancements in traditional Chinese medicine (TCM), as evidenced by scientific endeavors to integrate modern technologies. Therefore, TCM has experienced rapid modernization by leveraging artificial intelligence, nucleic acid molecular medicine, and bioelectronic medicine.


Result Analysis
Print
Save
E-mail