1.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
2.Objective Changes in the Contralateral Eye after Unilateral Cataract Surgery
Seung Hyeun LEE ; Kyoung Woo KIM ; In Ki PARK ; Yeoun Sook CHUN
Korean Journal of Ophthalmology 2025;39(1):48-56
Purpose:
This study evaluated the objective changes in the contralateral eye after unilateral cataract surgery.
Methods:
The study was designed as retrospective observational study. It included 44 patients who underwent unilateral cataract surgery. Collected data were uncorrected and corrected visual acuity, spherical equivalent, intraocular pressure, contrast sensitivity (CS), stereoacuity, and anterior segment optical coherence tomography parameters. Data were collected preoperatively, and 1 week and 1 month postoperatively for each eye.
Results:
Following unilateral cataract surgery, the pupil size of the fellow eye decreased from 3.46 mm to 3.17 mm (postoperative week 1, p = 0.003) and 3.08 mm (postoperative month 1, p < 0.001). Anterior chamber depth of the fellow eye increased significantly from 3.16 mm to 3.27 mm (postoperative week 1, p = 0.005) and 3.26 mm (postoperative month 1, p = 0.001). Uncorrected distance visual acuity (UDVA) of the fellow eye improved significantly at postoperative week 1 (p = 0.042) and postoperative month 1 (p = 0.044). Change of UDVA of the fellow eye at postoperative month 1 was significantly correlated with that of the treated eye (p = 0.039).
Conclusions
Anterior chamber structures changed and UDVA improved in the contralateral eye after unilateral cataract surgery in our cohort. Because fellow eyes were positively affected by monocular cataract surgery, it would be good information if planning for unilateral cataract surgery due to inevitable reasons.
3.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
4.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
5.The impact of the laboratory quality management program on colorectal cancer screening using immunochemical fecal occult blood tests in Korea
Hye Ryun LEE ; Sollip KIM ; Hyeongsu KIM ; Yeo-Min YUN ; Ho Jin JEONG ; Minje HAN ; Myeong Hee KIM ; Tae-Hyun UM ; You Kyoung LEE ; Byung Ryul JEON ; Kunsei LEE ; Sail CHUN
Journal of the Korean Medical Association 2025;68(5):338-347
Purpose:
Immunochemical fecal occult blood tests (iFOBT) have been utilized as the primary method for colorectal cancer screening within Korea's National Cancer Screening Program. This study aimed to evaluate the impact of the accreditation program for clinical laboratories and external quality assessment (EQA) programs on colorectal cancer screening.
Methods:
We analyzed the false-positive rates of iFOBT in colorectal cancer screening from 2016 to 2020 according to participation and performance in the Outstanding Laboratory Accreditation Program (OLAP) conducted by the Laboratory Medicine Foundation, and the External Quality Assessment programs run by the Korean Association of External Quality Assessment Service.
Results:
False-positive rates of iFOBT were lower among institutions accredited by OLAP (2.35%) compared with non-accredited (3.04%) and non-participating institutions (5.60%). Similarly, institutions participating in the EQA program exhibited lower false-positive rates (3.79%) compared to non-participants (7.04%). Within the iFOBT-specific EQA program, institutions that passed demonstrated the lowest false-positive rate (3.37%), while failing institutions showed the highest rate (9.07%), surpassing even non-participating institutions (6.44%).
Conclusion
Participation in quality management programs such as OLAP and EQA was associated with lower false-positive rates in iFOBT for colorectal cancer screening. These findings suggest that quality management initiatives can increase the accuracy of iFOBT, potentially improving the effectiveness of colorectal cancer screening programs, and reducing unnecessary follow-up procedures and associated healthcare costs.
6.Treatment of Chronic Inflammatory Demyelinating Polyneuropathy
Eun Kyoung LEE ; Sooyoung KIM ; Eunhee SOHN
Journal of the Korean Neurological Association 2025;43(2):83-89
Chronic inflammatory demyelinating polyneuropathy (CIDP) is a chronic autoimmune disease of the peripheral nervous system, primarily treated with corticosteroids and intravenous immunoglobulin as first-line therapies. Early treatment yields better outcome before nerve damage caused by the immune response. Once axonal damage has progressed, immunotherapy becomes ineffective, making early intervention crucial. Additionally, as treatment responses vary among patients, it is essential to assess treatment efficacy objectively and tailor therapy accordingly. Since there are currently no biomarkers that accurately reflect disease status, regular physical examinations are necessary to evaluate treatment effectiveness and adjust maintenance therapy. This review outlines the current clinical guidelines for the treatment of CIDP and explores emerging therapeutic options, including neonatal Fc receptor inhibitors and complement pathway inhibitors.
7.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
8.Simultaneous Four-site Restoration of Bilateral Scleromalacia Using Autologous Tragal Perichondrium and Preserved Sclera
Yoonsoo NAM ; Seung Hyeun LEE ; Kyoung Woo KIM
Journal of the Korean Ophthalmological Society 2025;66(1):63-69
Purpose:
We report a case of bilateral nasal and temporal four-site scleromalacia following cosmetic conjunctivectomy, successfully managed with simultaneous restoration surgery at all four sites using autologous tragal perichondrium and preserved scleral graft.Case summary: A 56-year-old woman who underwent cosmetic conjunctivectomy on both eyes 15 years earlier, presented with intermittent eye pain. Examination revealed scleromalacia with calcium plaques in all four nasal and temporal scleral areas. The most extensive avascular area was in the nasal region of the right eye, and the most prominent uveal exposure was in the nasal area of the left eye. Considering the lesion and exposure sizes of the avascular zone and uvea exposure, preserved sclera was transplanted to the temporal and nasal areas of the right eye, while autologous tragal perichondrium was transplanted to the nasal area of the left eye. Tenon's capsule vessels were fixed with pedicle flaps in all four surgical areas for vascularization. Frozen amniotic membrane was transplanted in the nasal area of the left eye, where the conjunctival defect was substantial, and in the lateral area of the left eye, where no graft was used. The conjunctival epithelium was closed using autologous conjunctival flaps in all four areas. Post-surgery, successful engraftment and vascularization of the graft materials were observed in both eyes.
Conclusions
Even with multiple areas of scleromalacia in both eyes, successful results can be achieved during simultaneous surgery if an appropriate graft material is selected and the surgery is performed utilizing principles of tissue restoration.
9.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
10.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.

Result Analysis
Print
Save
E-mail