1.Analysis on Quality Standard of Sennae Folium(Cassia angustifolia) Dispensing Granules Based on Standard Decoctions
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):192-200
ObjectiveTo establish the quality standards for Sennae Folium(Cassia angustifolia) dispensing granules based on standard decoctions. MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established for 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 of Sennae Folium(C. angustifolia) dispensing granules from different manufacturers, and the similarity evaluation, hierarchical cluster analysis(HCA) and principal component analysis(PCA) were performed. Linear calibration with two reference substances(LCTRS) and quantitative analysis of multi-components by single-marker(QAMS) were established for the common peaks in the specific chromatograms to determine the contents of main components in the decoction pieces, standard decoctions and dispensing granules, and to calculate their transfer rates from decoction pieces to standard decoctions and dispensing granules. ResultsThe similarities of specific chromatograms of 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 batches of Sennae Folium(C. angustifolia) dispensing granules were all greater than 0.95, and a total of 8 characteristic peaks were calibrated, and five of them were identified, including kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A. HCA and PCA results showed that there were certain differences in the composition of different batches of standard decoctions, but no clustering was observed in the production area. As the standard decoctions, the extract rate of 15 batches of samples was 26.54%-45.38%, the contents of kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A were 12.16-19.26, 2.57-4.94, 3.27-5.11, 6.75-11.39, 4.69-7.79 mg·g-1, and their transfer rates from decoction pieces to standard decoctions were 45.41%-79.02%, 29.12%-55.07%, 40.52%-67.90%, 24.72%-49.12%, 27.54%-49.34%, respectively. The extract rates of Sennae Folium(C. angustifolia) dispensing granules(C8-C10) were 38.10%-39.50%, the transfer rates of the above five components from decoction pieces to dispensing granules were 72.85%-73.58%, 53.43%-53.94%, 40.19%-40.74%, 24.62%-25.00%, 28.65%-29.11%, respectively, which were generally consistent with the transfer rates from decoction pieces to standard decoctions. ConclusionCompared with the relative retention time method, LCTRS has higher prediction accuracy and is more suitable for chromatographic columns. The established quality control standard of Sennae Folium(C. angustifolia) dispensing granules based on standard decoction is reasonable and reliable, and all indicators of samples from different manufacturers are within the range specified based on the standard decoction, which can provide reference for the quality control and process research of this dispensing granules.
2.Increased CT Attenuation of Pericolic Adipose Tissue as a Noninvasive Marker of Disease Severity in Ulcerative Colitis
Jun LU ; Hui XU ; Jing ZHENG ; Tianxin CHENG ; Xinjun HAN ; Yuxin WANG ; Xuxu MENG ; Xiaoyang LI ; Jiahui JIANG ; Xue DONG ; Xijie ZHANG ; Zhenchang WANG ; Zhenghan YANG ; Lixue XU
Korean Journal of Radiology 2025;26(5):411-421
Objective:
Accurate evaluation of inflammation severity in ulcerative colitis (UC) can guide treatment strategy selection. The potential value of the pericolic fat attenuation index (FAI) on CT as an indicator of disease severity remains unknown.This study aimed to assess the diagnostic accuracy of pericolic FAI in predicting UC severity.
Materials and Methods:
This retrospective study enrolled 148 patients (mean age 48 years; 87 males). The fat attenuation on CT was measured in four different locations: the mesocolic vascular side (MS) and opposite side of MS (OMS) around the most severe bowel lesion, the retroperitoneal space (RS), and the subcutaneous area. The fat attenuation indices (FAI MS, FAI OMS, and FAI RS) were calculated as the fat attenuation measured in MS, OMS, and RS, respectively, minus that of the subcutaneous area, and were obtained in the non-enhanced, arterial, and delayed phases. Correlations between the FAI and UC Endoscopic Index of Severity (UCEIS) were assessed using Spearman’s correlation. Predictors of severe UC (UCEIS ≥7) were selected by univariable analysis. The performance of FAI in predicting severe UC was evaluated using the area under the receiver operating characteristic curve (AUC).
Results:
The FAIMS and FAI OMS scores were significantly higher than FAI RS in three phases (all P < 0.001). The FAIMS and FAI OMS scores moderately correlated with the UCEIS score (r = 0.474–0.649 among the three phases). Additionally, FAI MS and FAI OMS identified severe UC, with AUC varying from 0.77 to 0.85.
Conclusion
Increased CT attenuation of pericolic adipose tissue could serve as a noninvasive marker for evaluating UC severity. FAI MS and FAI OMS of three phases showed similar prediction accuracies for severe UC identification.
3.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
5.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
6.Clinical and Immunological Characteristics of Elderly Onset Rheumatoid Arthritis
Zhengfang LI ; Chanyuan WU ; Mengsi MA ; Tingting LI ; Xue WU ; Xinyan MENG ; Sha ZHANG ; Lijun WU
Medical Journal of Peking Union Medical College Hospital 2025;16(1):59-64
To investigate the clinical features and peripheral blood immune cell subsets ofelderly (≥60 years old) onset rheumatoid arthritis (EORA) patients. The patients with rheumatoid arthritis (RA) who were hospitalized in the Department of Rheumatology and Immunology of the People's Hospital of Xinjiang Uygur Autonomous Region from March 2023 to December 2023 were selected as the study objects. The demographic data, clinical characteristics, extra-articular manifestations and laboratory examination results of the patients were collected. The patients were divided into EORA group and young adult (< 60 years old)onset rheumatoid arthritis (YORA) group, and the clinical features and peripheral blood immunological indexes of the two groups were compared. A total of 187 RA patients with an average age of (62.1±12.0) years were enrolled, including 89 patients in the EORA group and 98 patients in the YORA group. Compared with YORA group, EORA group had a higher proportion of male patients(39.3% Compared with YORA, EORA has higher male proportion, joint disease degree and disease activity. EORA is prone to interstitial lung disease, anemia and high inflammation, and the level of peripheral blood NK cells is higher.
7.Increased CT Attenuation of Pericolic Adipose Tissue as a Noninvasive Marker of Disease Severity in Ulcerative Colitis
Jun LU ; Hui XU ; Jing ZHENG ; Tianxin CHENG ; Xinjun HAN ; Yuxin WANG ; Xuxu MENG ; Xiaoyang LI ; Jiahui JIANG ; Xue DONG ; Xijie ZHANG ; Zhenchang WANG ; Zhenghan YANG ; Lixue XU
Korean Journal of Radiology 2025;26(5):411-421
Objective:
Accurate evaluation of inflammation severity in ulcerative colitis (UC) can guide treatment strategy selection. The potential value of the pericolic fat attenuation index (FAI) on CT as an indicator of disease severity remains unknown.This study aimed to assess the diagnostic accuracy of pericolic FAI in predicting UC severity.
Materials and Methods:
This retrospective study enrolled 148 patients (mean age 48 years; 87 males). The fat attenuation on CT was measured in four different locations: the mesocolic vascular side (MS) and opposite side of MS (OMS) around the most severe bowel lesion, the retroperitoneal space (RS), and the subcutaneous area. The fat attenuation indices (FAI MS, FAI OMS, and FAI RS) were calculated as the fat attenuation measured in MS, OMS, and RS, respectively, minus that of the subcutaneous area, and were obtained in the non-enhanced, arterial, and delayed phases. Correlations between the FAI and UC Endoscopic Index of Severity (UCEIS) were assessed using Spearman’s correlation. Predictors of severe UC (UCEIS ≥7) were selected by univariable analysis. The performance of FAI in predicting severe UC was evaluated using the area under the receiver operating characteristic curve (AUC).
Results:
The FAIMS and FAI OMS scores were significantly higher than FAI RS in three phases (all P < 0.001). The FAIMS and FAI OMS scores moderately correlated with the UCEIS score (r = 0.474–0.649 among the three phases). Additionally, FAI MS and FAI OMS identified severe UC, with AUC varying from 0.77 to 0.85.
Conclusion
Increased CT attenuation of pericolic adipose tissue could serve as a noninvasive marker for evaluating UC severity. FAI MS and FAI OMS of three phases showed similar prediction accuracies for severe UC identification.
8.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
9.Methylamine Thiocyanate-doped FA 0.8Cs 0.2PbI 2Br Perovskite Sensor for Sensitive and Ultrafast Detection of NO 2 at Room Temperature
Yan-Shang GONG ; Meng-Han ZHAO ; Jian-Kun SUN ; Li-Xue ZHANG
Chinese Journal of Analytical Chemistry 2025;53(4):525-534,中插1-中插8
Nitrogen dioxide(NO 2)is a prevalent air pollutant that poses significant threats to the environment and human health,emphasizing the urgent need for high-performance NO 2 sensors for effective environmental monitoring at room temperature.Sensors based on metal halide perovskites have emerged as promising candidates for gas detection at room temperature,but their long-term stability remains a major challenge.In this study,a methylamine thiocyanate(MT)-doped FA 0.8Cs 0.2PbI 2Br(PVK)gas sensor(MT-PVK)was prepared using a simple one-step spin-coating method and ethyl acetate(EA)anti-solvent extraction technique.The crystalline structure,chemical composition,and particle morphology of the MT-PVK thin film were characterized.The MT-PVK thin film was then utilized as a gas sensor for NO 2 detection at room temperature.The results demonstrated that the sensor exhibited outstanding selectivity and reversibility at low concentrations of NO 2 gas,with a detection limit as low as 33 ppb(10-9,nL/L).For 10 ppm(10-6,μL/L)NO 2,the sensor showed rapid response and recovery time of only 1.6 s and 27 s,outperforming most traditional metal oxide NO 2 sensors.Furthermore,compared to the original PVK,the MT molecules significantly enhanced the structural and sensing stability of the MT-PVK sensor under high humidity conditions(55%±5%).These findings suggested that MT-doped FA 0.8Cs 0.2PbI 2Br perovskite gas sensors offered a promising pathway for the development of rapid-response gas sensing technologies suitable for room temperature operation.
10.Safety and efficacy of prophylactic jejunal feeding tube during pylorus-preserving gastrectomy
Dan XUE ; Ran HU ; Haiqiao ZHANG ; Hongjie LI ; Jie YIN ; Meng SUN ; Jun ZHANG
International Journal of Surgery 2025;52(9):617-621
Objective:To explore the perioperative safety and postoperative efficacy of prophylactic jejunal nutrition tube placement during early gastric body cancer pylorus-preserving gastrectomy (PPG).Methods:The clinical data of 29 gastric cancer patients treated by Beijing Friendship Hospital, Capital Medical University from January 2018 to December 2024 were retrospectively analyzed. There were 17 males (58.6%) and 12 females (41.4%), aged from 43 to 74 years, with an average age of (58.9 ± 8.3) years, and an average body mass index (BMI) of (24.3 ± 3.0) kg/m 2. According to the type of catheterization, all cases were divided into jejunal nutrition tube group ( n=12) and gastric tube group( n=17). The main outcome was the incidence of delayed gastric emptying within one month after surgery in both groups. Statistical analysis was conducted using SPSS26.0 software. Results:Patients in the jejunal feeding tube group resumed oral liquid intake, soft diet and regular diet significantly earlier postoperatively compared to those in the gastric tube group, with statistically significant differences ( P<0.05). Conversely, the time to removal of the tube was significantly earlier in the gastric tube group than in the jejunal feeding tube group ( P<0.05). However, the proportion of patients requiring reinsertion of a gastric or jejunal feeding tube postoperatively was significantly higher in the gastric tube group (7 cases) compared to the jejunal feeding tube group (0 case) ( P<0.05). In the jejunal feeding tube group, there were 4 cases occurred DGE, in the gastric tube group, there were 8 cases occurred DGE. There were no statistically significant differences between the two groups in either the overall incidence of DGE or the distribution of DGE severity grades. On postoperative 7th day , the Gastric Outlet Obstruction Scoring System (GOOSS) grade was significantly better in the jejunal feeding tube group than in the gastric tube group ( P<0.05), and all patients in the jejunal feeding tube group had resumed liquid intake, compared to only 58.8% in the gastric tube group. Conclusions:Compared with gastric tube placement, intraoperative prophylactic jejunal feeding tube placement for PPG has significant advantages in perioperative safety and postoperative recovery, but large-sample prospective studies are still needed for further verification.

Result Analysis
Print
Save
E-mail