1.Quantitative Analysis of Drusen in South Korean Patients: A 36-Month Follow-Up Study
Tae Rim KIM ; Tae Gi KIM ; Jaehwan CHOI ; Seung-Young YU ; Kiyoung KIM
Korean Journal of Ophthalmology 2026;40(1):87-98
Purpose:
This study aimed to quantitatively evaluate longitudinal changes in drusen area and volume over 36 months in South Korean patients and to identify the factors associated with these changes and the development of advanced age-related macular degeneration (AMD).
Methods:
In this retrospective study, 38 eyes from 38 patients diagnosed with drusen were analyzed. The drusen area and volume were measured using spectral-domain optical coherence tomography (SD-OCT; Cirrus 5000, Carl Zeiss Meditec) with an automated retinal pigment epithelium elevation map algorithm. To minimize bias from variable follow-up intervals, an annualized classification framework was adopted. Based on percentage change in drusen area within the 5-mm circle, eyes were categorized as progressed (increase >20%), stable (change within ±20%), or regressing (decrease >20%).
Results:
Both drusen area and volume increased significantly up to 24 months (area, p = 0.003; volume, p = 0.028) and then showed a modest decline at 36 months, remaining above baseline levels. No significant difference in the proportions of progressed, stable, or regressing eyes was observed across 12-month intervals or compared with baseline (all p > 0.05). A larger baseline 5-mm drusen area was significantly associated with the development of advanced AMD (adjusted odds ratio, 2.818; 95% confidence interval, 1.022–7.767; p = 0.045). Eyes that exhibited at least one episode of drusen regression showed a higher incidence of advanced AMD (36.8% vs. 5.3%, p = 0.042).
Conclusions
Drusen in South Korean patients demonstrated dynamic morphological remodeling over time. Drusen regression was not a benign phenomenon but rather a potential high-risk marker for progression to advanced AMD. These findings highlight the importance of population-specific, quantitative SD-OCT monitoring for early risk stratification in East Asian eyes.
2.Impact of medical crisis on the critical care system in South Korea
Ye Rim CHANG ; Jae Hwa CHO ; Joongbum CHO ; Tae Sun HA ; Bo Gun KHO ; Eunhye KIM ; Im-kyung KIM ; Dong Hyun LEE ; Suk-Kyung HONG
Acute and Critical Care 2025;40(3):393-401
Background:
The ongoing medical crisis in Korea has severely impacted the operational environment of intensive care units (ICU), posing significant challenges to quality care for critically ill patients. This study aimed to evaluate the effects of the ongoing crisis on ICUs.
Methods:
A survey was conducted in July 2024 among intensivists in charge of ICUs at institutions accredited by the Korean Society of Critical Care Medicine for critical care. The survey compared data from January 2024 (pre-crisis) and June 2024 (post-crisis) on the number ICU beds, staffing composition, work hours, and the number and roles of nurse practitioners.
Results:
Among the total of 71 participating ICUs, 22 experienced a reduction in the number of operational beds, with a median decrease of six beds per unit, totaling 127 beds across these ICUs. The numbers of residents and interns decreased from an average of 2.3 to 0.1 per ICU, and the average weekly working hours of intensivists increased from 62.3 to 78.8 hours. Nurse practitioners helped fill staffing gaps, with their numbers rising from 150 to 242 across ICUs, and their scope of practice expanded accordingly.
Conclusions
The medical crisis has led to major changes in the critical care system, including staffing shortages, increased workloads, and an expanded role for nurse practitioners. This is a critical moment to foster interest and engage in active discussions aimed at creating a sustainable and resilient ICU system.
3.Expert Consensus on Developing Information and Communication Technology-Based Patient Education Guidelines for Rheumatic Diseases in the Korea
Junghee YOON ; Soo-Kyung CHO ; Se Rim CHOI ; Soo-Bin LEE ; Juhee CHO ; Chan Hong JEON ; Geun-Tae KIM ; Jisoo LEE ; Yoon-Kyoung SUNG
Journal of Korean Medical Science 2025;40(1):e67-
Background:
This study aimed to identify key priorities for the development of guidelines for information and communication technology (ICT)-based patient education tailored to the needs of patients with rheumatic diseases (RDs) in the Republic of Korea, based on expert consensus.
Methods:
A two-round modified Delphi study was conducted with 20 rheumatology, patient education, and digital health literacy experts. A total of 35 items covering 7 domains and 18 subdomains were evaluated. Each item was evaluated for its level of importance, and the responses were rated on a 4-point Likert scale. Consensus levels were defined as “high” (interquartile range [IQR] ≤ 1, agreement ≥ 80%, content validity ratio [CVR] ≥ 0.7), "Moderate" (IQR ≥ 1, agreement 50–79%, CVR 0.5–0.7), and "Low" (IQR > 1, agreement < 50%, CVR < 0.5).
Results:
Strong consensus was reached for key priorities for developing guidelines in areas such as health literacy, digital health literacy, medical terminology, user interface, and user experience design for mobile apps. Chatbot use and video (e.g., YouTube) also achieved high consensus, whereas AI-powered platforms such as ChatGPT showed moderate-to-high agreement. Telemedicine was excluded because of insufficient consensus.
Conclusion
The key priorities identified in this study provide a foundation for the development of ICT-based patient education guidelines for RDs in the Republic of Korea.Future efforts should focus on integrating digital tools into clinical practice to enhance patient engagement and improve clinical outcomes.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
6.Expert Consensus on Developing Information and Communication Technology-Based Patient Education Guidelines for Rheumatic Diseases in the Korea
Junghee YOON ; Soo-Kyung CHO ; Se Rim CHOI ; Soo-Bin LEE ; Juhee CHO ; Chan Hong JEON ; Geun-Tae KIM ; Jisoo LEE ; Yoon-Kyoung SUNG
Journal of Korean Medical Science 2025;40(1):e67-
Background:
This study aimed to identify key priorities for the development of guidelines for information and communication technology (ICT)-based patient education tailored to the needs of patients with rheumatic diseases (RDs) in the Republic of Korea, based on expert consensus.
Methods:
A two-round modified Delphi study was conducted with 20 rheumatology, patient education, and digital health literacy experts. A total of 35 items covering 7 domains and 18 subdomains were evaluated. Each item was evaluated for its level of importance, and the responses were rated on a 4-point Likert scale. Consensus levels were defined as “high” (interquartile range [IQR] ≤ 1, agreement ≥ 80%, content validity ratio [CVR] ≥ 0.7), "Moderate" (IQR ≥ 1, agreement 50–79%, CVR 0.5–0.7), and "Low" (IQR > 1, agreement < 50%, CVR < 0.5).
Results:
Strong consensus was reached for key priorities for developing guidelines in areas such as health literacy, digital health literacy, medical terminology, user interface, and user experience design for mobile apps. Chatbot use and video (e.g., YouTube) also achieved high consensus, whereas AI-powered platforms such as ChatGPT showed moderate-to-high agreement. Telemedicine was excluded because of insufficient consensus.
Conclusion
The key priorities identified in this study provide a foundation for the development of ICT-based patient education guidelines for RDs in the Republic of Korea.Future efforts should focus on integrating digital tools into clinical practice to enhance patient engagement and improve clinical outcomes.
7.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
8.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
9.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
10.Expert Consensus on Developing Information and Communication Technology-Based Patient Education Guidelines for Rheumatic Diseases in the Korea
Junghee YOON ; Soo-Kyung CHO ; Se Rim CHOI ; Soo-Bin LEE ; Juhee CHO ; Chan Hong JEON ; Geun-Tae KIM ; Jisoo LEE ; Yoon-Kyoung SUNG
Journal of Korean Medical Science 2025;40(1):e67-
Background:
This study aimed to identify key priorities for the development of guidelines for information and communication technology (ICT)-based patient education tailored to the needs of patients with rheumatic diseases (RDs) in the Republic of Korea, based on expert consensus.
Methods:
A two-round modified Delphi study was conducted with 20 rheumatology, patient education, and digital health literacy experts. A total of 35 items covering 7 domains and 18 subdomains were evaluated. Each item was evaluated for its level of importance, and the responses were rated on a 4-point Likert scale. Consensus levels were defined as “high” (interquartile range [IQR] ≤ 1, agreement ≥ 80%, content validity ratio [CVR] ≥ 0.7), "Moderate" (IQR ≥ 1, agreement 50–79%, CVR 0.5–0.7), and "Low" (IQR > 1, agreement < 50%, CVR < 0.5).
Results:
Strong consensus was reached for key priorities for developing guidelines in areas such as health literacy, digital health literacy, medical terminology, user interface, and user experience design for mobile apps. Chatbot use and video (e.g., YouTube) also achieved high consensus, whereas AI-powered platforms such as ChatGPT showed moderate-to-high agreement. Telemedicine was excluded because of insufficient consensus.
Conclusion
The key priorities identified in this study provide a foundation for the development of ICT-based patient education guidelines for RDs in the Republic of Korea.Future efforts should focus on integrating digital tools into clinical practice to enhance patient engagement and improve clinical outcomes.

Result Analysis
Print
Save
E-mail