1.Sex-Specific Reference Intervals and AgeRelated Variations in Hematologic Parameters in Korean Adults Measured Using the Beckman Coulter DxH 900 Analyzer
Shinae YU ; Eunkyoung YOU ; Sae Am SONG ; Jeong Nyeo LEE ; Kyung Ran JUN ; Ja Young LEE
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):6-13
Background:
This study established sex-specific reference intervals (RIs) for hematological parameters, including the monocyte distribution width (MDW), in Korean adults and assessed the need for separate RIs according to sex in older adults.
Methods:
Hematological parameters were measured using a DxH 900 hematology analyzer (Beckman Coulter, USA) on 328 peripheral blood samples from 124 men and 204 women aged 19–93 years.
Results:
The RIs for white blood cells, red blood cells (RBCs), Hb, Hct, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, monocyte percentage, and neutrophil, eosinophil, lymphocyte, and monocyte counts differed significantly by sex (P<0.05). Mean corpuscular volume was significantly positively associated with age, whereas RBC and platelet counts were significantly negatively correlated with age in both men and women. Age-based analysis revealed significant shifts in the RBC parameters beginning at 60 years of age in men and 70 years of age in women. The MDW did not show significant differences according to sex or age.
Conclusions
This study supports the use of sex-specific RIs and highlights the importance of considering age when interpreting results regarding hematological parameters in clinical practice.
2.Sex-Specific Reference Intervals and AgeRelated Variations in Hematologic Parameters in Korean Adults Measured Using the Beckman Coulter DxH 900 Analyzer
Shinae YU ; Eunkyoung YOU ; Sae Am SONG ; Jeong Nyeo LEE ; Kyung Ran JUN ; Ja Young LEE
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):6-13
Background:
This study established sex-specific reference intervals (RIs) for hematological parameters, including the monocyte distribution width (MDW), in Korean adults and assessed the need for separate RIs according to sex in older adults.
Methods:
Hematological parameters were measured using a DxH 900 hematology analyzer (Beckman Coulter, USA) on 328 peripheral blood samples from 124 men and 204 women aged 19–93 years.
Results:
The RIs for white blood cells, red blood cells (RBCs), Hb, Hct, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, monocyte percentage, and neutrophil, eosinophil, lymphocyte, and monocyte counts differed significantly by sex (P<0.05). Mean corpuscular volume was significantly positively associated with age, whereas RBC and platelet counts were significantly negatively correlated with age in both men and women. Age-based analysis revealed significant shifts in the RBC parameters beginning at 60 years of age in men and 70 years of age in women. The MDW did not show significant differences according to sex or age.
Conclusions
This study supports the use of sex-specific RIs and highlights the importance of considering age when interpreting results regarding hematological parameters in clinical practice.
3.Sex-Specific Reference Intervals and AgeRelated Variations in Hematologic Parameters in Korean Adults Measured Using the Beckman Coulter DxH 900 Analyzer
Shinae YU ; Eunkyoung YOU ; Sae Am SONG ; Jeong Nyeo LEE ; Kyung Ran JUN ; Ja Young LEE
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):6-13
Background:
This study established sex-specific reference intervals (RIs) for hematological parameters, including the monocyte distribution width (MDW), in Korean adults and assessed the need for separate RIs according to sex in older adults.
Methods:
Hematological parameters were measured using a DxH 900 hematology analyzer (Beckman Coulter, USA) on 328 peripheral blood samples from 124 men and 204 women aged 19–93 years.
Results:
The RIs for white blood cells, red blood cells (RBCs), Hb, Hct, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, monocyte percentage, and neutrophil, eosinophil, lymphocyte, and monocyte counts differed significantly by sex (P<0.05). Mean corpuscular volume was significantly positively associated with age, whereas RBC and platelet counts were significantly negatively correlated with age in both men and women. Age-based analysis revealed significant shifts in the RBC parameters beginning at 60 years of age in men and 70 years of age in women. The MDW did not show significant differences according to sex or age.
Conclusions
This study supports the use of sex-specific RIs and highlights the importance of considering age when interpreting results regarding hematological parameters in clinical practice.
4.Sex-Specific Reference Intervals and AgeRelated Variations in Hematologic Parameters in Korean Adults Measured Using the Beckman Coulter DxH 900 Analyzer
Shinae YU ; Eunkyoung YOU ; Sae Am SONG ; Jeong Nyeo LEE ; Kyung Ran JUN ; Ja Young LEE
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):6-13
Background:
This study established sex-specific reference intervals (RIs) for hematological parameters, including the monocyte distribution width (MDW), in Korean adults and assessed the need for separate RIs according to sex in older adults.
Methods:
Hematological parameters were measured using a DxH 900 hematology analyzer (Beckman Coulter, USA) on 328 peripheral blood samples from 124 men and 204 women aged 19–93 years.
Results:
The RIs for white blood cells, red blood cells (RBCs), Hb, Hct, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, monocyte percentage, and neutrophil, eosinophil, lymphocyte, and monocyte counts differed significantly by sex (P<0.05). Mean corpuscular volume was significantly positively associated with age, whereas RBC and platelet counts were significantly negatively correlated with age in both men and women. Age-based analysis revealed significant shifts in the RBC parameters beginning at 60 years of age in men and 70 years of age in women. The MDW did not show significant differences according to sex or age.
Conclusions
This study supports the use of sex-specific RIs and highlights the importance of considering age when interpreting results regarding hematological parameters in clinical practice.
5.Sex-Specific Reference Intervals and AgeRelated Variations in Hematologic Parameters in Korean Adults Measured Using the Beckman Coulter DxH 900 Analyzer
Shinae YU ; Eunkyoung YOU ; Sae Am SONG ; Jeong Nyeo LEE ; Kyung Ran JUN ; Ja Young LEE
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):6-13
Background:
This study established sex-specific reference intervals (RIs) for hematological parameters, including the monocyte distribution width (MDW), in Korean adults and assessed the need for separate RIs according to sex in older adults.
Methods:
Hematological parameters were measured using a DxH 900 hematology analyzer (Beckman Coulter, USA) on 328 peripheral blood samples from 124 men and 204 women aged 19–93 years.
Results:
The RIs for white blood cells, red blood cells (RBCs), Hb, Hct, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, monocyte percentage, and neutrophil, eosinophil, lymphocyte, and monocyte counts differed significantly by sex (P<0.05). Mean corpuscular volume was significantly positively associated with age, whereas RBC and platelet counts were significantly negatively correlated with age in both men and women. Age-based analysis revealed significant shifts in the RBC parameters beginning at 60 years of age in men and 70 years of age in women. The MDW did not show significant differences according to sex or age.
Conclusions
This study supports the use of sex-specific RIs and highlights the importance of considering age when interpreting results regarding hematological parameters in clinical practice.
6.Antigenicity evaluation of lac color and exploratory study for identifying potential biomarkers of anaphylaxis
Hyun‑Jin LIM ; Kang Min HAN ; Seung‑Hyun KIM ; Soo‑Kyung RYU ; Ji‑Ran YOU ; Jung‑Hee YOON ; Euna KWON ; Ji‑Eun KIM ; Byeong‑Cheol KANG
Laboratory Animal Research 2024;40(4):461-475
Background:
Lac color, a natural red dye derived from the larvae of laccifer lacca kerr, is one of the most commonly used substances in food. To date, no studies have reported on the antigenicity of lac color and the other biomarkers that can determine anaphylactic reactions. To address this, we evaluated the antigenicity of lac color through active systemic anaphylaxis (ASA) in addition to identifying potential biomarkers performing exploratory studies. For ASA test, Guinea pigs (n = 5) were sensitized with 0(negative control), 4 mg/kg of lac color, 4 mg/kg of lac color + FCA, and 5 mg/kg of ovalbumin + FCA (positive control) 3 times a week for three weeks. Fourteen days after the last sensi‑ tization, animals were challenged intravenously weekly for two weeks. Hematological and histopathological analyses were performed and compared to control groups.
Results:
In the ASA test, all lac color groups showed mild symptoms such as nose rubbing, urination, and evacuation, which are insufficient indicators of anaphylaxis. Exploratory studies identified several biomarkers: decreased platelet count, and increased basophil count; distention in the lung, and redness on the inner wall of trachea; mononuclear inflammatory cell infiltration (MICI) in the ear, and heart hemorrhage. When these biomarkers were applied to the ASA test of lac color, in comparison to the negative control group, the positive control group (ovalbumin + FCA) showed a significant over 60-fold reduction in platelet count and nearly threefold higher basophil count compared to other groups. Furthermore, only positive control group exhibited full lung distention and severe redness on the inner wall of the trachea. Mononuclear inflammatory cell infiltration (MICI) in the ear was about three times higher, and heart hemorrhage was only present in the positive control group compared to others. None of the lac color groups were different from the negative control group (p > 0.05), whereas the positive control group was significantly different (p < 0.05).
Conclusions
Our study concludes that lac color, at the tested concentrations, does not induce antigenicity in the guinea pig model, providing valuable safety data. Furthermore, the biomarkers identified in this study offer a supportive approach to evaluating the immunogenicity of substances in future research.
7.Antigenicity evaluation of lac color and exploratory study for identifying potential biomarkers of anaphylaxis
Hyun‑Jin LIM ; Kang Min HAN ; Seung‑Hyun KIM ; Soo‑Kyung RYU ; Ji‑Ran YOU ; Jung‑Hee YOON ; Euna KWON ; Ji‑Eun KIM ; Byeong‑Cheol KANG
Laboratory Animal Research 2024;40(4):461-475
Background:
Lac color, a natural red dye derived from the larvae of laccifer lacca kerr, is one of the most commonly used substances in food. To date, no studies have reported on the antigenicity of lac color and the other biomarkers that can determine anaphylactic reactions. To address this, we evaluated the antigenicity of lac color through active systemic anaphylaxis (ASA) in addition to identifying potential biomarkers performing exploratory studies. For ASA test, Guinea pigs (n = 5) were sensitized with 0(negative control), 4 mg/kg of lac color, 4 mg/kg of lac color + FCA, and 5 mg/kg of ovalbumin + FCA (positive control) 3 times a week for three weeks. Fourteen days after the last sensi‑ tization, animals were challenged intravenously weekly for two weeks. Hematological and histopathological analyses were performed and compared to control groups.
Results:
In the ASA test, all lac color groups showed mild symptoms such as nose rubbing, urination, and evacuation, which are insufficient indicators of anaphylaxis. Exploratory studies identified several biomarkers: decreased platelet count, and increased basophil count; distention in the lung, and redness on the inner wall of trachea; mononuclear inflammatory cell infiltration (MICI) in the ear, and heart hemorrhage. When these biomarkers were applied to the ASA test of lac color, in comparison to the negative control group, the positive control group (ovalbumin + FCA) showed a significant over 60-fold reduction in platelet count and nearly threefold higher basophil count compared to other groups. Furthermore, only positive control group exhibited full lung distention and severe redness on the inner wall of the trachea. Mononuclear inflammatory cell infiltration (MICI) in the ear was about three times higher, and heart hemorrhage was only present in the positive control group compared to others. None of the lac color groups were different from the negative control group (p > 0.05), whereas the positive control group was significantly different (p < 0.05).
Conclusions
Our study concludes that lac color, at the tested concentrations, does not induce antigenicity in the guinea pig model, providing valuable safety data. Furthermore, the biomarkers identified in this study offer a supportive approach to evaluating the immunogenicity of substances in future research.
8.Antigenicity evaluation of lac color and exploratory study for identifying potential biomarkers of anaphylaxis
Hyun‑Jin LIM ; Kang Min HAN ; Seung‑Hyun KIM ; Soo‑Kyung RYU ; Ji‑Ran YOU ; Jung‑Hee YOON ; Euna KWON ; Ji‑Eun KIM ; Byeong‑Cheol KANG
Laboratory Animal Research 2024;40(4):461-475
Background:
Lac color, a natural red dye derived from the larvae of laccifer lacca kerr, is one of the most commonly used substances in food. To date, no studies have reported on the antigenicity of lac color and the other biomarkers that can determine anaphylactic reactions. To address this, we evaluated the antigenicity of lac color through active systemic anaphylaxis (ASA) in addition to identifying potential biomarkers performing exploratory studies. For ASA test, Guinea pigs (n = 5) were sensitized with 0(negative control), 4 mg/kg of lac color, 4 mg/kg of lac color + FCA, and 5 mg/kg of ovalbumin + FCA (positive control) 3 times a week for three weeks. Fourteen days after the last sensi‑ tization, animals were challenged intravenously weekly for two weeks. Hematological and histopathological analyses were performed and compared to control groups.
Results:
In the ASA test, all lac color groups showed mild symptoms such as nose rubbing, urination, and evacuation, which are insufficient indicators of anaphylaxis. Exploratory studies identified several biomarkers: decreased platelet count, and increased basophil count; distention in the lung, and redness on the inner wall of trachea; mononuclear inflammatory cell infiltration (MICI) in the ear, and heart hemorrhage. When these biomarkers were applied to the ASA test of lac color, in comparison to the negative control group, the positive control group (ovalbumin + FCA) showed a significant over 60-fold reduction in platelet count and nearly threefold higher basophil count compared to other groups. Furthermore, only positive control group exhibited full lung distention and severe redness on the inner wall of the trachea. Mononuclear inflammatory cell infiltration (MICI) in the ear was about three times higher, and heart hemorrhage was only present in the positive control group compared to others. None of the lac color groups were different from the negative control group (p > 0.05), whereas the positive control group was significantly different (p < 0.05).
Conclusions
Our study concludes that lac color, at the tested concentrations, does not induce antigenicity in the guinea pig model, providing valuable safety data. Furthermore, the biomarkers identified in this study offer a supportive approach to evaluating the immunogenicity of substances in future research.
9.Antigenicity evaluation of lac color and exploratory study for identifying potential biomarkers of anaphylaxis
Hyun‑Jin LIM ; Kang Min HAN ; Seung‑Hyun KIM ; Soo‑Kyung RYU ; Ji‑Ran YOU ; Jung‑Hee YOON ; Euna KWON ; Ji‑Eun KIM ; Byeong‑Cheol KANG
Laboratory Animal Research 2024;40(4):461-475
Background:
Lac color, a natural red dye derived from the larvae of laccifer lacca kerr, is one of the most commonly used substances in food. To date, no studies have reported on the antigenicity of lac color and the other biomarkers that can determine anaphylactic reactions. To address this, we evaluated the antigenicity of lac color through active systemic anaphylaxis (ASA) in addition to identifying potential biomarkers performing exploratory studies. For ASA test, Guinea pigs (n = 5) were sensitized with 0(negative control), 4 mg/kg of lac color, 4 mg/kg of lac color + FCA, and 5 mg/kg of ovalbumin + FCA (positive control) 3 times a week for three weeks. Fourteen days after the last sensi‑ tization, animals were challenged intravenously weekly for two weeks. Hematological and histopathological analyses were performed and compared to control groups.
Results:
In the ASA test, all lac color groups showed mild symptoms such as nose rubbing, urination, and evacuation, which are insufficient indicators of anaphylaxis. Exploratory studies identified several biomarkers: decreased platelet count, and increased basophil count; distention in the lung, and redness on the inner wall of trachea; mononuclear inflammatory cell infiltration (MICI) in the ear, and heart hemorrhage. When these biomarkers were applied to the ASA test of lac color, in comparison to the negative control group, the positive control group (ovalbumin + FCA) showed a significant over 60-fold reduction in platelet count and nearly threefold higher basophil count compared to other groups. Furthermore, only positive control group exhibited full lung distention and severe redness on the inner wall of the trachea. Mononuclear inflammatory cell infiltration (MICI) in the ear was about three times higher, and heart hemorrhage was only present in the positive control group compared to others. None of the lac color groups were different from the negative control group (p > 0.05), whereas the positive control group was significantly different (p < 0.05).
Conclusions
Our study concludes that lac color, at the tested concentrations, does not induce antigenicity in the guinea pig model, providing valuable safety data. Furthermore, the biomarkers identified in this study offer a supportive approach to evaluating the immunogenicity of substances in future research.
10.Antigenicity evaluation of lac color and exploratory study for identifying potential biomarkers of anaphylaxis
Hyun‑Jin LIM ; Kang Min HAN ; Seung‑Hyun KIM ; Soo‑Kyung RYU ; Ji‑Ran YOU ; Jung‑Hee YOON ; Euna KWON ; Ji‑Eun KIM ; Byeong‑Cheol KANG
Laboratory Animal Research 2024;40(4):461-475
Background:
Lac color, a natural red dye derived from the larvae of laccifer lacca kerr, is one of the most commonly used substances in food. To date, no studies have reported on the antigenicity of lac color and the other biomarkers that can determine anaphylactic reactions. To address this, we evaluated the antigenicity of lac color through active systemic anaphylaxis (ASA) in addition to identifying potential biomarkers performing exploratory studies. For ASA test, Guinea pigs (n = 5) were sensitized with 0(negative control), 4 mg/kg of lac color, 4 mg/kg of lac color + FCA, and 5 mg/kg of ovalbumin + FCA (positive control) 3 times a week for three weeks. Fourteen days after the last sensi‑ tization, animals were challenged intravenously weekly for two weeks. Hematological and histopathological analyses were performed and compared to control groups.
Results:
In the ASA test, all lac color groups showed mild symptoms such as nose rubbing, urination, and evacuation, which are insufficient indicators of anaphylaxis. Exploratory studies identified several biomarkers: decreased platelet count, and increased basophil count; distention in the lung, and redness on the inner wall of trachea; mononuclear inflammatory cell infiltration (MICI) in the ear, and heart hemorrhage. When these biomarkers were applied to the ASA test of lac color, in comparison to the negative control group, the positive control group (ovalbumin + FCA) showed a significant over 60-fold reduction in platelet count and nearly threefold higher basophil count compared to other groups. Furthermore, only positive control group exhibited full lung distention and severe redness on the inner wall of the trachea. Mononuclear inflammatory cell infiltration (MICI) in the ear was about three times higher, and heart hemorrhage was only present in the positive control group compared to others. None of the lac color groups were different from the negative control group (p > 0.05), whereas the positive control group was significantly different (p < 0.05).
Conclusions
Our study concludes that lac color, at the tested concentrations, does not induce antigenicity in the guinea pig model, providing valuable safety data. Furthermore, the biomarkers identified in this study offer a supportive approach to evaluating the immunogenicity of substances in future research.

Result Analysis
Print
Save
E-mail