1.En bloc capsulectomy of a pseudocyst-like pocket after a massive filler injection into the buttocks: two case reports
Kyung Min KIM ; Jeong Hun AHN ; Ki Hyun KIM ; Sang Seok WOO ; Jun Won LEE ; Seong Hwan KIM ; Jai Koo CHOI ; Insuck SUH
Archives of Aesthetic Plastic Surgery 2026;32(2):26-31
Buttock augmentation is an increasingly popular cosmetic procedure designed to enhance buttock contour, size, and shape. However, the safety profile of this procedure remains insufficiently established, and it carries risks of complications, including foreign body reactions and infections. These complications may be exacerbated by filler migration, resulting in large soft-tissue cavities that resemble pseudocysts. In this study, we describe two patients who developed severe complications following massive filler injections to the buttocks. A 56-year-old female patient presented with a 6×5 cm soft-tissue defect associated with an extensive underlying dead space, sinus tract formation, and a large pocket extending across the buttock. Additionally, a 50-year-old female patient developed diffuse cellulitis and multiple abscesses secondary to migration of an infected filler-related pseudocyst. Both patients underwent successful en bloc capsulectomy, resulting in marked clinical improvement without recurrence or postoperative complications. These cases underscore the serious complications associated with large-volume filler injections and highlight the importance of comprehensive surgical management in addressing late-stage adverse outcomes.
2.When Fire Meets Ice: a Case of Silent Clinical Course after Massive Levothyroxine and Sedative Co-Ingestion
Kyung-Hun SUNG ; Jaekyung LEE ; Seung-Hwan LEE ; Dong-Jun LIM
International Journal of Thyroidology 2026;19(1):110-113
Levothyroxine overdose is uncommon in adults and often presents with variable clinical severity, ranging from overt thyrotoxicosis to an entirely asymptomatic course. We report the case of a 47-year-old woman with a history of total thyroidectomy who intentionally ingested 10 mg of levothyroxine along with supratherapeutic doses of zolpidem and clonazepam at once in a suicide attempt. She presented three days later without adrenergic or gastrointestinal symptoms. Laboratory tests revealed markedly elevated free thyroxine and total triiodothyronine with suppressed thyroid stimulating hormone. She was treated with propranolol for heart rate control and empirical hydrocortisone in case of adrenal insufficiency. She remained asymptomatic with gradual biochemical improvement and normalization of thyroid function on follow-up. The protective effect of co-ingested supratherapeutic doses of gamma-aminobutyric acid (GABA)-ergic agents suggests a potential role for anti-anxiety medications in mitigating severe adrenergic symptoms in endogenous thyrotoxicosis, such as Graves’ disease.
3.Comparison of Higher-order Aberrations Outcomes between Sutured Scleral Fixation and Modified Yamane Sutureless Scleral Fixation
Dong Jin HAN ; Myung Jun SEONG ; Jong Min LEE ; Jong Hyun LEE ; Do Hyung LEE ; Min Kyung SONG ; Hun JIn CHOI
Journal of the Korean Ophthalmological Society 2025;66(2):86-93
Purpose:
We investigated the changes in ocular higher-order aberrations (HOAs) between sutured scleral fixation and modified Yamane sutureless scleral fixation.
Methods:
We retrospectively reviewed 20 patients (20 eyes) who underwent sutured scleral fixation and 22 patients (22 eyes) who underwent modified Yamane sutureless scleral fixation. The best corrected visual acuity (BCVA) and HOAs were measured preoperatively, and at 3 months postoperatively, and the two groups were compared.
Results:
BCVA was significantly improved in both sutured scleral fixation and modified Yamane sutureless scleral fixation (p = 0.038, 0.015, respectively). The internal optic HOAs decreased significantly after scleral fixation both in both groups (p = 0.012, 0.033, respectively). Postoperative internal optic HOAs were significantly higher in modified Yamane sutureless scleral fixation group than in sutured scleral fixation group. (p = 0.034) Postoperative third-order aberrations, coma-like aberrations were significantly higher in modified Yamane sutureless scleral fixation group than in sutured scleral fixation group. (p = 0.032, 0.038, respectively)
Conclusions
Sutured scleral fixation showed more effectively decreased internal optics HOAs. IOL tilt and decentrations correlated with internal HOAs and thus should be avoided particularly in modified Yamane sutureless scleral fixation.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain: a multicenter cross-sectional study in Korea
Jieun BAE ; Yun Hee LIM ; Sung Jun HONG ; Jae Hun JEONG ; Hey Ran CHOI ; Sun Kyung PARK ; Jung Eun KIM ; Jae Hun KIM
The Korean Journal of Pain 2025;38(1):69-78
Background:
Chronic pain significantly affects daily activities, mental health, and the interpersonal relationships of patients. Consequently, physicians use various treatments to manage pain. This study investigated the perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain.
Methods:
The authors enrolled patients with chronic pain from 19 university hospitals in South Korea. Data was collected on age, gender, diagnosis, disease duration, severity of pain, perception of pain treatment, and accompanying symptoms or problems using an anonymous survey comprising 19 questions.
Results:
In total, 833 patients with chronic pain completed the survey, and 257 (31.0%) and 537 (64.5%) patientsexpressed concerns about the potential adverse effects of medication and opioid addiction, respectively. Personalitychanges such as irritability or anger were the most frequent accompanying symptoms in 507 (63.8%) patients, followed by depression and sleep disturbance in 462 (58.1%) and 450 (54.5%) patients, respectively. Depression (P = 0.001) and anxiety (P = 0.029) were more common among women, whereas divorce (P = 0.016), family conflict (P < 0.001), unemployment (P < 0.001), suicide attempts (P < 0.001), and restrictions on economic activity (P < 0.001) were more common among men. The frequency of accompanying symptoms, except for suicidal ideation,was higher in the younger patients aged ≤ 40 years than in the older patients aged > 40 years.
Conclusions
Many patients with chronic pain had concerns about adverse effects or medication tolerance and experienced anxiety, depression, or sleep disturbances. The prevalence of accompanying problems varies according to age and gender.
6.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
7.Perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain: a multicenter cross-sectional study in Korea
Jieun BAE ; Yun Hee LIM ; Sung Jun HONG ; Jae Hun JEONG ; Hey Ran CHOI ; Sun Kyung PARK ; Jung Eun KIM ; Jae Hun KIM
The Korean Journal of Pain 2025;38(1):69-78
Background:
Chronic pain significantly affects daily activities, mental health, and the interpersonal relationships of patients. Consequently, physicians use various treatments to manage pain. This study investigated the perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain.
Methods:
The authors enrolled patients with chronic pain from 19 university hospitals in South Korea. Data was collected on age, gender, diagnosis, disease duration, severity of pain, perception of pain treatment, and accompanying symptoms or problems using an anonymous survey comprising 19 questions.
Results:
In total, 833 patients with chronic pain completed the survey, and 257 (31.0%) and 537 (64.5%) patientsexpressed concerns about the potential adverse effects of medication and opioid addiction, respectively. Personalitychanges such as irritability or anger were the most frequent accompanying symptoms in 507 (63.8%) patients, followed by depression and sleep disturbance in 462 (58.1%) and 450 (54.5%) patients, respectively. Depression (P = 0.001) and anxiety (P = 0.029) were more common among women, whereas divorce (P = 0.016), family conflict (P < 0.001), unemployment (P < 0.001), suicide attempts (P < 0.001), and restrictions on economic activity (P < 0.001) were more common among men. The frequency of accompanying symptoms, except for suicidal ideation,was higher in the younger patients aged ≤ 40 years than in the older patients aged > 40 years.
Conclusions
Many patients with chronic pain had concerns about adverse effects or medication tolerance and experienced anxiety, depression, or sleep disturbances. The prevalence of accompanying problems varies according to age and gender.
8.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
9.Perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain: a multicenter cross-sectional study in Korea
Jieun BAE ; Yun Hee LIM ; Sung Jun HONG ; Jae Hun JEONG ; Hey Ran CHOI ; Sun Kyung PARK ; Jung Eun KIM ; Jae Hun KIM
The Korean Journal of Pain 2025;38(1):69-78
Background:
Chronic pain significantly affects daily activities, mental health, and the interpersonal relationships of patients. Consequently, physicians use various treatments to manage pain. This study investigated the perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain.
Methods:
The authors enrolled patients with chronic pain from 19 university hospitals in South Korea. Data was collected on age, gender, diagnosis, disease duration, severity of pain, perception of pain treatment, and accompanying symptoms or problems using an anonymous survey comprising 19 questions.
Results:
In total, 833 patients with chronic pain completed the survey, and 257 (31.0%) and 537 (64.5%) patientsexpressed concerns about the potential adverse effects of medication and opioid addiction, respectively. Personalitychanges such as irritability or anger were the most frequent accompanying symptoms in 507 (63.8%) patients, followed by depression and sleep disturbance in 462 (58.1%) and 450 (54.5%) patients, respectively. Depression (P = 0.001) and anxiety (P = 0.029) were more common among women, whereas divorce (P = 0.016), family conflict (P < 0.001), unemployment (P < 0.001), suicide attempts (P < 0.001), and restrictions on economic activity (P < 0.001) were more common among men. The frequency of accompanying symptoms, except for suicidal ideation,was higher in the younger patients aged ≤ 40 years than in the older patients aged > 40 years.
Conclusions
Many patients with chronic pain had concerns about adverse effects or medication tolerance and experienced anxiety, depression, or sleep disturbances. The prevalence of accompanying problems varies according to age and gender.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail