1.Part 1. Current Status of Hearing Loss Patients in Korea Using National Data: National Health Insurance Service- Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(1):7-18
Background and Objectives:
Hearing loss significantly affects communication, psychosocial well-being, and quality of life. This study analyzes the National Health Insurance Service database to assess the trends and characteristics of hearing loss in South Korea from 2010 to 2020.Subjects and Method The database encompasses 97% of the Korean population, providing comprehensive data on medical history, prescriptions, and health examinations. The analysis used the World Health Organization’s ICD-10 definitions to categorize hearing loss types and examine their prevalence and incidence across various demographics over 11 years.
Results:
There was an overall annual increase of 4.62% in diagnosed cases of hearing loss, with the most significant rise among the elderly. The rate of increase accelerated from 3.32% between 2010 and 2014 to 6.49% between 2014 and 2020, corresponding with the improved hearing aid access facilitated by policy changes. Women showed a slightly higher increase than men. The data also indicated a consistent rise in abnormal hearing test results during health examinations, especially in older adults.
Conclusion
The study highlights an increasing trend in hearing loss diagnoses, driven by an aging population and enhanced detection facilitated by policy changes. These findings emphasize the need for continuous monitoring and targeted health policies to manage hearing loss effectively, offering valuable insights for global health management and policy development.
2.Part 2. Current Status of Hearing Disability and Hearing Rehabilitation Devices in Korea Using National Data: NHIS-Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(3):94-104
Background and Objectives:
This study aims to analyze trends in hearing disability and the use of hearing rehabilitation devices (hearing aids and cochlear implants) in South Korea over the past 11 years (2010-2020) using data from the National Health Insurance Service (NHIS).Subjects and Method Data were extracted from the NHIS database, covering approximately 97% of the South Korean population. Patients diagnosed with hearing loss were classified using ICD-10 codes. The data were analyzed to determine trends in hearing disability, hearing aid prescriptions, and cochlear implant usage by age, gender, and types and causes of hearing loss.
Results:
The number of hearing disability patients increased from 170900 in 2010 to 362738 in 2020, with an annual growth rate of 7.95%. The highest increase was observed in the ≥60 age group, with an annual growth rate of 11.04%. Hearing aid prescriptions rose from 4966 in 2010 to 11974 in 2020, showing a 10.45% annual increase. Females showed a higher growth rate in both hearing disability and hearing aid prescriptions compared to males. Cochlear implant prescriptions also increased, particularly among older adults.
Conclusion
The study highlights a significant rise in hearing disability and the use of hearing aids and cochlear implants in South Korea, especially among the elderly. The findings underscore the importance of early diagnosis and intervention for hearing loss and the need for policy improvements to enhance accessibility and affordability of hearing rehabilitation services. Additional strategies are needed to ensure appropriate hearing rehabilitation for those not yet receiving adequate care.
3.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
4.Factors associated with Hypertensive Retinopathy among People with Hypertension: A Systematic Review
Ihn Sook JEONG ; Chan Mi KANG ; Eun Joo LEE ; Seol Bin KIM ; Young Kyung SEO ; Young Shin SON ; Kun Hyung KIM
Journal of Korean Academy of Community Health Nursing 2025;36(1):130-149
Purpose:
The associated factors for hypertensive retinopathy (HTR) are rarely investigated. This study aimed to identify the associated factors for HTR using a systematic review.
Methods:
The review included cross-sectional, case-controlled, and cohort studies on HTR risk factors published in Korean and English with full texts available from PubMed, Embase, CINAHL, Web of Science, and Korean databases. Methodological quality was assessed using the Joanna Briggs Institute (JBI) checklist.
Results:
Eleven studies were finally selected, and three studies including patients with hypertension without diabetes mellitus, older age, male sex, alcohol consumption, the duration of hypertension, hyperglycemia, dyslipidemia, microalbuminuria, high creatinine levels, chronic kidney disease, and cardiovascular changes were identified as factors associated with HTR. Conversely, in the remaining eight studies, younger age, non-smoking status, and renal function indicators (albuminuria, high creatinine levels, chronic kidney disease, and uric acid) were identified as associated factors.
Conclusions
Regardless of the inclusion of patients with diabetes mellitus, impaired kidney functions were determined as significant factors associated with retinopathy in patients with HTR. However, considering a limited number of evidence and lack of evidence to confirm causality, we recommend further research on renal function and HTR.
5.Radiological characteristics of shoulder diseases in older adults, including adhesive capsulitis, rotator cuff tear, and osteoarthritis of the glenohumeral joint: a narrative review
The Ewha Medical Journal 2025;48(1):e10-
Shoulder diseases, including adhesive capsulitis, rotator cuff tear, and osteoarthritis of the glenohumeral joint, can significantly impair daily activities in older adult patients. This review aims to examine the radiologic findings associated with these shoulder conditions in older patients, providing insights for accurate diagnosis and effective treatment. Adhesive capsulitis, commonly known as frozen shoulder, leads to pain and restricted movement, thereby causing shoulder dysfunction. Recent advances in diagnostic technology have greatly enhanced the sensitivity and accuracy of diagnosing this condition through radiologic evaluations, including MRI, magnetic resonance arthrography (MRA), and high-resolution ultrasound. Rotator cuff disease is another frequent issue in older adults, with full-thickness tears occurring in 50%–80% of cases. Both MRI and MRA are highly sensitive and specific in identifying rotator cuff tears. Additionally, ultrasonography is recognized for its high sensitivity and specificity in detecting tears of the supraspinatus tendon. Although osteoarthritis of the glenohumeral joint is less commonly prevalent, its advanced stages can severely affect the function of the upper extremity. Plain radiography is typically the first imaging technique used to assess this type of osteoarthritis. As the condition worsens, CT is utilized to measure glenoid bone loss, glenoid version, and inclination, which are crucial for accurate surgical planning. Each imaging modality provides distinct benefits: plain radiographs for initial structural assessment, ultrasonography for real-time evaluation of soft tissues, MRI/MRA for detailed visualization of capsular and tendinous lesions, and CT for precise bony analysis.
6.Increased risk of dementia in patients with primary Sjogren’s syndrome: a nationwide population-based cohort study
Kyung-Ann LEE ; Hyeji JEON ; Hyun-Sook KIM ; Kyomin CHOI ; Gi Hyeon SEO
The Korean Journal of Internal Medicine 2025;40(2):330-338
Background/Aims:
This nationwide cohort study aimed to evaluate (1) whether primary Sjogren’s syndrome (pSS) can contribute to the development of dementia and (2) whether the use of hydroxychloroquine (HCQ) can decrease the incidence of dementia in patients with pSS using the Health Insurance Review and Assessment database.
Methods:
We established a cohort between 2008 and 2020 of 20,160 patients with pSS without a history of dementia. The control group comprised sex- and age-matched individuals with no history of autoimmune disease or dementia. Cox proportional hazard analyses were performed to identify the association between pSS and dementia development. We also assessed the hazard ratio (HR) of dementia in early users of HCQ (within 180 days of the diagnosis of pSS) compared to non-users, adjusted for age, sex, and comorbidities.
Results:
The incidence of dementia was 0.68 (95% CI 0.64–0.72) cases per 100 person-years in pSS, and it was 0.58 (0.56–0.60) in the controls. The adjusted HR (aHR) of developing dementia was 1.16 (1.09–1.25) times greater in the pSS group than in the controls. The risk of dementia did not increase in HCQ users (aHR 1.07 [0.94–1.21]), but HCQ non-users had a 1.22 (1.12–1.33) higher risk of developing dementia than the matched controls. The use of HCQ lowered the risk of dementia in comparison with non-users in patients with pSS (aHR 0.82 [0.71–0.94]).
Conclusions
Our results suggest that pSS is associated with an increased risk of dementia. HCQ may prevent dementia in patients with pSS.
7.Part 1. Current Status of Hearing Loss Patients in Korea Using National Data: National Health Insurance Service- Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(1):7-18
Background and Objectives:
Hearing loss significantly affects communication, psychosocial well-being, and quality of life. This study analyzes the National Health Insurance Service database to assess the trends and characteristics of hearing loss in South Korea from 2010 to 2020.Subjects and Method The database encompasses 97% of the Korean population, providing comprehensive data on medical history, prescriptions, and health examinations. The analysis used the World Health Organization’s ICD-10 definitions to categorize hearing loss types and examine their prevalence and incidence across various demographics over 11 years.
Results:
There was an overall annual increase of 4.62% in diagnosed cases of hearing loss, with the most significant rise among the elderly. The rate of increase accelerated from 3.32% between 2010 and 2014 to 6.49% between 2014 and 2020, corresponding with the improved hearing aid access facilitated by policy changes. Women showed a slightly higher increase than men. The data also indicated a consistent rise in abnormal hearing test results during health examinations, especially in older adults.
Conclusion
The study highlights an increasing trend in hearing loss diagnoses, driven by an aging population and enhanced detection facilitated by policy changes. These findings emphasize the need for continuous monitoring and targeted health policies to manage hearing loss effectively, offering valuable insights for global health management and policy development.
8.Part 2. Current Status of Hearing Disability and Hearing Rehabilitation Devices in Korea Using National Data: NHIS-Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(3):94-104
Background and Objectives:
This study aims to analyze trends in hearing disability and the use of hearing rehabilitation devices (hearing aids and cochlear implants) in South Korea over the past 11 years (2010-2020) using data from the National Health Insurance Service (NHIS).Subjects and Method Data were extracted from the NHIS database, covering approximately 97% of the South Korean population. Patients diagnosed with hearing loss were classified using ICD-10 codes. The data were analyzed to determine trends in hearing disability, hearing aid prescriptions, and cochlear implant usage by age, gender, and types and causes of hearing loss.
Results:
The number of hearing disability patients increased from 170900 in 2010 to 362738 in 2020, with an annual growth rate of 7.95%. The highest increase was observed in the ≥60 age group, with an annual growth rate of 11.04%. Hearing aid prescriptions rose from 4966 in 2010 to 11974 in 2020, showing a 10.45% annual increase. Females showed a higher growth rate in both hearing disability and hearing aid prescriptions compared to males. Cochlear implant prescriptions also increased, particularly among older adults.
Conclusion
The study highlights a significant rise in hearing disability and the use of hearing aids and cochlear implants in South Korea, especially among the elderly. The findings underscore the importance of early diagnosis and intervention for hearing loss and the need for policy improvements to enhance accessibility and affordability of hearing rehabilitation services. Additional strategies are needed to ensure appropriate hearing rehabilitation for those not yet receiving adequate care.
9.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
10.Factors associated with Hypertensive Retinopathy among People with Hypertension: A Systematic Review
Ihn Sook JEONG ; Chan Mi KANG ; Eun Joo LEE ; Seol Bin KIM ; Young Kyung SEO ; Young Shin SON ; Kun Hyung KIM
Journal of Korean Academy of Community Health Nursing 2025;36(1):130-149
Purpose:
The associated factors for hypertensive retinopathy (HTR) are rarely investigated. This study aimed to identify the associated factors for HTR using a systematic review.
Methods:
The review included cross-sectional, case-controlled, and cohort studies on HTR risk factors published in Korean and English with full texts available from PubMed, Embase, CINAHL, Web of Science, and Korean databases. Methodological quality was assessed using the Joanna Briggs Institute (JBI) checklist.
Results:
Eleven studies were finally selected, and three studies including patients with hypertension without diabetes mellitus, older age, male sex, alcohol consumption, the duration of hypertension, hyperglycemia, dyslipidemia, microalbuminuria, high creatinine levels, chronic kidney disease, and cardiovascular changes were identified as factors associated with HTR. Conversely, in the remaining eight studies, younger age, non-smoking status, and renal function indicators (albuminuria, high creatinine levels, chronic kidney disease, and uric acid) were identified as associated factors.
Conclusions
Regardless of the inclusion of patients with diabetes mellitus, impaired kidney functions were determined as significant factors associated with retinopathy in patients with HTR. However, considering a limited number of evidence and lack of evidence to confirm causality, we recommend further research on renal function and HTR.

Result Analysis
Print
Save