1.Clinical Outcome after Everolimus-Eluting Stent Implantation for Small Vessel Coronary Artery Disease: XIENCE Asia Small Vessel Study
Doo Sun SIM ; Dae Young HYUN ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Myung Ho JEONG ; Sang Rok LEE ; Jei Keon CHAE ; Keun Ho PARK ; Young Youp KOH ; Kyeong Ho YUN ; Seok Kyu OH ; Seung Jae JOO ; Sun Ho HWANG ; Jong Pil PARK ; Jay Young RHEW ; Su Hyun KIM ; Jang Hyun CHO ; Seung Uk LEE ; Dong Goo KANG
Chonnam Medical Journal 2024;60(1):78-86
There are limited data on outcomes after implantation of everolimus-eluting stents (EES) in East Asian patients with small vessel coronary lesions. A total of 1,600 patients treated with XIENCE EES (Abbott Vascular, CA, USA) were divided into the small vessel group treated with one ≤2.5 mm stent (n=119) and the non-small vessel group treated with one ≥2.75 mm stent (n=933). The primary end point was a patient-oriented composite outcome (POCO), a composite of all-cause death, myocardial infarction (MI), and any repeat revascularization at 12 months. The key secondary end point was a device-oriented composite outcome (DOCO), a composite of cardiovascular death, target-vessel MI, and target lesion revascularization at 12 months. The small vessel group was more often female, hypertensive, less likely to present with ST-elevation MI, and more often treated for the left circumflex artery, whereas the non-small vessel group more often had type B2/C lesions, underwent intravascular ultrasound, and received unfractionated heparin. In the propensity matched cohort, the mean stent diameter was 2.5±0.0 mm and 3.1±0.4 mm in the small and non-small vessel groups, respectively. Propensity-adjusted POCO at 12 months was 6.0% in the small vessel group and 4.3% in the non-small vessel group (p=0.558). There was no significant difference in DOCO at 12 months (small vessel group: 4.3% and non-small vessel group: 1.7%, p=0.270).Outcomes of XIENCE EES for small vessel disease were comparable to those for non-small vessel disease at 12-month clinical follow-up in real-world Korean patients.
2.First-in-Human Evaluation of a Polymer-Free Everolimus-Eluting Stent Using a Titanium Dioxide Film
Doo Sun SIM ; Kyung Hoon CHO ; Dae Young HYUN ; Dae Sung PARK ; Jun-Kyu PARK ; Dae-Heung BYEON ; Won-Il JO ; Sang-Wook KIM ; Joon Ho AHN ; Seung Hun LEE ; Min Chul KIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Myung Ho JEONG
Journal of Korean Medical Science 2024;39(33):e234-
Background:
In patients with coronary artery disease treated with permanent polymercoated drug-eluting stents (DES), the persistent presence of a less biocompatible polymer might delay arterial healing. Thin strut polymer-free DES have the potential to improve clinical outcomes and reduce the duration of dual antiplatelet therapy (DAPT). The purpose of this first-in-human study was to assess the safety and effectiveness of a novel polymer-free DES in patients with de novo coronary lesions. The TIGERevolutioN® stent (CG Bio Co., Ltd., Seoul, Korea) consists of a cobalt chromium platform with a strut thickness of 70 μm and a surface treated with titanium dioxide onto which everolimus-eluting stent (EES) is applied abluminally (6 µg/mm of stent length) without utilization of a polymer.
Methods:
A total of 20 patients were enrolled, with de novo coronary lesions (stable or unstable angina) and > 50% diameter stenosis in a vessel 2.25 to 4.00 mm in diameter and ≤ 40 mm in length for angiographic, optical coherence tomography (OCT), and clinical assessment at 8 months. All patients received DAPT after stent implantation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at 8 months.
Results:
Twenty patients with 20 lesions were treated with TIGERevolutioN® . At 8 months, in-stent LLL was 0.7 ± 0.4 mm. On OCT, percent area stenosis was 29.2 ± 9.4% and stent strut coverage was complete in all lesions. No adverse cardiovascular event occurred at 8 months.
Conclusion
The new polymer-free EES was safe and effective with low LLL and excellent strut coverage at 8 months of follow-up.
3.Asia-Pacific consensus on long-term and sequential therapy for osteoporosis
Ta-Wei TAI ; Hsuan-Yu CHEN ; Chien-An SHIH ; Chun-Feng HUANG ; Eugene MCCLOSKEY ; Joon-Kiong LEE ; Swan Sim YEAP ; Ching-Lung CHEUNG ; Natthinee CHARATCHAROENWITTHAYA ; Unnop JAISAMRARN ; Vilai KUPTNIRATSAIKUL ; Rong-Sen YANG ; Sung-Yen LIN ; Akira TAGUCHI ; Satoshi MORI ; Julie LI-YU ; Seng Bin ANG ; Ding-Cheng CHAN ; Wai Sin CHAN ; Hou NG ; Jung-Fu CHEN ; Shih-Te TU ; Hai-Hua CHUANG ; Yin-Fan CHANG ; Fang-Ping CHEN ; Keh-Sung TSAI ; Peter R. EBELING ; Fernando MARIN ; Francisco Javier Nistal RODRÍGUEZ ; Huipeng SHI ; Kyu Ri HWANG ; Kwang-Kyoun KIM ; Yoon-Sok CHUNG ; Ian R. REID ; Manju CHANDRAN ; Serge FERRARI ; E Michael LEWIECKI ; Fen Lee HEW ; Lan T. HO-PHAM ; Tuan Van NGUYEN ; Van Hy NGUYEN ; Sarath LEKAMWASAM ; Dipendra PANDEY ; Sanjay BHADADA ; Chung-Hwan CHEN ; Jawl-Shan HWANG ; Chih-Hsing WU
Osteoporosis and Sarcopenia 2024;10(1):3-10
Objectives:
This study aimed to present the Asia-Pacific consensus on long-term and sequential therapy for osteoporosis, offering evidence-based recommendations for the effective management of this chronic condition.The primary focus is on achieving optimal fracture prevention through a comprehensive, individualized approach.
Methods:
A panel of experts convened to develop consensus statements by synthesizing the current literature and leveraging clinical expertise. The review encompassed long-term anti-osteoporosis medication goals, first-line treatments for individuals at very high fracture risk, and the strategic integration of anabolic and anti resorptive agents in sequential therapy approaches.
Results:
The panelists reached a consensus on 12 statements. Key recommendations included advocating for anabolic agents as the first-line treatment for individuals at very high fracture risk and transitioning to anti resorptive agents following the completion of anabolic therapy. Anabolic therapy remains an option for in dividuals experiencing new fractures or persistent high fracture risk despite antiresorptive treatment. In cases of inadequate response, the consensus recommended considering a switch to more potent medications. The consensus also addressed the management of medication-related complications, proposing alternatives instead of discontinuation of treatment.
Conclusions
This consensus provides a comprehensive, cost-effective strategy for fracture prevention with an emphasis on shared decision-making and the incorporation of country-specific case management systems, such as fracture liaison services. It serves as a valuable guide for healthcare professionals in the Asia-Pacific region, contributing to the ongoing evolution of osteoporosis management.
4.Preliminary Investigation on Efficacy and Safety of Substance P-Coated Stent for Promoting Re-Endothelialization: A Porcine Coronary Artery Restenosis Model
Dae Sung PARK ; Seok OH ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Young HYUN ; Kyung Hoon CHO ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Manuel HERMIDA-PRIETO ; José Manuel VÁZQUEZ-RODRIGUEZ ; Juan Luis GUTIÉRREZ- CHICO ; Luis MARINÃS-PARDO ; Kyung Seob LIM ; Jun-Kyu PARK ; Dae-Heung BYEON ; Young-Nan CHO ; Seung-Jung KEE ; Doo Sun SIM ; Myung Ho JEONG
Tissue Engineering and Regenerative Medicine 2024;21(1):53-64
BACKGROUND:
Current polymer-based drug-eluting stents (DESs) have fundamental issues about inflammation and delayed re-endothelializaton of the vessel wall. Substance-P (SP), which plays an important role in inflammation and endothelial cells, has not yet been applied to coronary stents. Therefore, this study compares poly lactic-co-glycolic acid (PLGA)-based everolimus-eluting stents (PLGA-EESs) versus 2-methacryloyloxyethyl phosphorylcholine (MPC)-based SP-eluting stents (MPC-SPs) in in-vitro and in-vivo models.
METHODS:
The morphology of the stent surface and peptide/drug release kinetics from stents were evaluated. The invitro proliferative effect of SP released from MPC-SP is evaluated using human umbilical vein endothelial cell. Finally, the safety and efficacy of the stent are evaluated after inserting it into a pig’s coronary artery.
RESULTS:
Similar to PLGA-EES, MPC-SP had a uniform surface morphology with very thin coating layer thickness (2.074 lm). MPC-SP showed sustained drug release of SP for over 2 weeks. Endothelial cell proliferation was significantly increased in groups treated with SP (n = 3) compared with the control (n = 3) and those with everolimus (n = 3) (SP:118.9 ± 7.61% vs. everolimus: 64.3 ± 12.37% vs. the control: 100 ± 6.64%, p < 0.05). In the animal study, the percent stenosis was higher in MPC-SP group (n = 7) compared to PLGA-EES group (n = 7) (MPC-SP: 28.6 ± 10.7% vs. PLGAEES: 16.7 ± 6.3%, p < 0.05). MPC-SP group showed, however, lower inflammation (MPC-SP: 0.3 ± 0.26 vs. PLGAEES: 1.2 ± 0.48, p < 0.05) and fibrin deposition (MPC-SP: 1.0 ± 0.73 vs. PLGA-EES: 1.5 ± 0.59, p < 0.05) around the stent strut. MPC-SP showed more increased expression of cluster of differentiation 31, suggesting enhanced reendothelialization.
CONCLUSION
Compared to PLGA-EES, MPC-SP demonstrated more decreased inflammation of the vascular wall and enhanced re-endothelialization and stent coverage. Hence, MPC-SP has the potential therapeutic benefits for the treatment of coronary artery disease by solving limitations of currently available DESs.
5.Preclinical Evaluation of an Everolimus-Eluting Bioresorbable Vascular Scaffold Via a Long-Term Rabbit Iliac Artery Model
Dae Sung PARK ; Myung Ho JEONG ; Yu Jeong JIN ; Mi Hyang NA ; Doo Sun SIM ; Munki KIM ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Jeong Ha KIM ; Kyung Seob LIM ; Jun-Kyu PARK ; Han Ki KIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2023;20(2):239-249
BACKGROUND:
Biodegradable poly (l-lactic acid) (PLLA), a bio safe polymer with a large elastic modulus, is widely used in biodegradable medical devices. However, because of its poor mechanical properties, a PLLA strut must be made twice as thick as a metal strut for adequate blood vessel support. Therefore, the mechanical properties of a drug-eluting metal-based stents (MBS) and a bioresorbable vascular scaffolds (BVS) were evaluated and their safety and efficacy were examined via a long-term rabbit iliac artery model.
METHODS:
The surface morphologies of the MBSs and BVSs were investigated via optical and scanning electron microscopy. An everolimus-eluting (EE) BVS or an EE-MBS was implanted into rabbit iliac arteries at a 1.1:1 stent-toartery ratio. Twelve months afterward, stented iliac arteries from each group were analyzed via X-ray angiography, optical coherence tomography (OCT), and histopathologic evaluation.
RESULTS:
Surface morphology analysis of the EE coating on the MBS confirmed that it was uniform and very thin (4.7 lm). Comparison of the mechanical properties of the EE-MBS and EE-BVS showed that the latter outperformed the former in all aspects (radial force (2.75 vs. 0.162 N/mm), foreshortening (0.24% vs. 1.9%), flexibility (0.52 vs. 0.19 N), and recoil (3.2% vs. 6.3%). At all time points, the percent area restenosis was increased in the EE-BVS group compared to the EE-MBS group. The OCT and histopathological analyses indicate no significant changes in strut thickness.
CONCLUSION
BVSs with thinner struts and shorter resorption times should be developed. A comparable long-term safety/efficacy evaluation after complete absorption of BVSs should be conducted.
6.Comparison of the Effectiveness of Three Lumbosacral Orthoses on Early Spine Surgery Patients: A Prospective Cohort Study
Soo Woong JANG ; Hee Seung YANG ; Young Bae KIM ; Joo Chul YANG ; Kyu Bok KANG ; Tae Wan KIM ; Kwan Ho PARK ; Kyung Soo JEON ; Hee Dong SHIN ; Ye Eun KIM ; Han Na CHO ; Yun Kyung LEE ; Young LEE ; Seul Bin Na LEE ; Dong Young AHN ; Woo Sob SIM ; Min JO ; Gyu Jik JO ; Dong Bum PARK ; Gwan Su PARK
Annals of Rehabilitation Medicine 2021;45(1):24-32
Objective:
To compare the convenience and effectiveness of the existing lumbosacral orthoses (LSO) (classic LSO and Cybertech) and a newly developed LSO (V-LSO) by analyzing postoperative data.
Methods:
This prospective cohort study was performed from May 2019 to November 2019 and enrolled and analyzed 88 patients with degenerative lumbar spine disease scheduled for elective lumbar surgery. Three types of LSO that were provided according to the time of patient registration were applied for 6 weeks. Patients were randomized into the classic LSO group (n=31), Cybertech group (n=26), and V-LSO group (n=31). All patients were assessed using the Oswestry Disability Index (ODI) preoperatively and underwent plain lumbar radiography (anteroposterior and lateral views) 10 days postoperatively. Lumbar lordosis (LS angle) and frontal imbalance were measured with and without LSO. At the sixth postoperative week, a follow-up assessment with the ODI and orthosis questionnaire was conducted.
Results:
No significant differences were found among the three groups in terms of the LS angle, frontal imbalance, ODI, and orthosis questionnaire results. When the change in the LS angle and frontal imbalance toward the reference value was defined as a positive change with and without LSO, the rate of positive change was significantly different in the V-LSO group (LS angle: 41.94% vs. 61.54% vs. 83.87%; p=0.003).
Conclusion
The newly developed LSO showed no difference regarding its effectiveness and compliance when compared with the existing LSO, but it was more effective in correcting lumbar lordosis.
7.Preclinical Evaluation of a Novel Polymer-free Everolimus-eluting Stent in a Mid-term Porcine Coronary Restenosis Model
Kyung Hoon CHO ; Myung Ho JEONG ; Dae Sung PARK ; Moonki KIM ; JungHa KIM ; Jun-Kyu PARK ; Xiongyi HAN ; Dae Young HYUN ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN
Journal of Korean Medical Science 2021;36(40):e259-
Background:
Titanium dioxide films exhibit good biocompatibility and may be effective as drug-binding matrices for drug-eluting stents. We conducted a mid-term evaluation of a novel polymer-free everolimus-eluting stent using nitrogen-doped titanium dioxide film deposition (TIGEREVOLUTION® ) in comparison with a commercial durable polymer everolimus-eluting stent (XIENCE Alpine® ) in a porcine coronary restenosis model.
Methods:
Twenty-eight coronary arteries from 14 mini-pigs were randomly allocated to TIGEREVOLUTION® stent and XIENCE Alpine® stent groups. The stents were implanted in the coronary artery at a 1.1–1.2:1 stent-to-artery ratio. Eleven stented coronary arteries in each group were finally analyzed using coronary angiography, optical coherence tomography, and histopathologic evaluation 6 months after stenting.
Results:
Quantitative coronary analysis showed no significant differences in the preprocedural, post-procedural, and 6-month lumen diameters between the groups. In the volumetric analysis of optical coherence tomography at 6 months, no significant differences were observed in stent volume, lumen volume, and percent area stenosis between the groups. There were no significant differences in injury score, inflammation score, or fibrin score between the groups, although the fibrin score was zero in the TIGEREVOLUTION® stent group (0 vs. 0.07 ± 0.11, P = 0.180).
Conclusion
Preclinical evaluation, including optical coherence tomographic findings 6 months after stenting, demonstrated that the TIGEREVOLUTION® stent exhibited efficacy and safety comparable with the XIENCE Alpine® stent, supporting the need for further clinical studies on the TIGEREVOLUTION® stent.
8.Preclinical Evaluation of a Novel Polymer-free Everolimus-eluting Stent in a Mid-term Porcine Coronary Restenosis Model
Kyung Hoon CHO ; Myung Ho JEONG ; Dae Sung PARK ; Moonki KIM ; JungHa KIM ; Jun-Kyu PARK ; Xiongyi HAN ; Dae Young HYUN ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN
Journal of Korean Medical Science 2021;36(40):e259-
Background:
Titanium dioxide films exhibit good biocompatibility and may be effective as drug-binding matrices for drug-eluting stents. We conducted a mid-term evaluation of a novel polymer-free everolimus-eluting stent using nitrogen-doped titanium dioxide film deposition (TIGEREVOLUTION® ) in comparison with a commercial durable polymer everolimus-eluting stent (XIENCE Alpine® ) in a porcine coronary restenosis model.
Methods:
Twenty-eight coronary arteries from 14 mini-pigs were randomly allocated to TIGEREVOLUTION® stent and XIENCE Alpine® stent groups. The stents were implanted in the coronary artery at a 1.1–1.2:1 stent-to-artery ratio. Eleven stented coronary arteries in each group were finally analyzed using coronary angiography, optical coherence tomography, and histopathologic evaluation 6 months after stenting.
Results:
Quantitative coronary analysis showed no significant differences in the preprocedural, post-procedural, and 6-month lumen diameters between the groups. In the volumetric analysis of optical coherence tomography at 6 months, no significant differences were observed in stent volume, lumen volume, and percent area stenosis between the groups. There were no significant differences in injury score, inflammation score, or fibrin score between the groups, although the fibrin score was zero in the TIGEREVOLUTION® stent group (0 vs. 0.07 ± 0.11, P = 0.180).
Conclusion
Preclinical evaluation, including optical coherence tomographic findings 6 months after stenting, demonstrated that the TIGEREVOLUTION® stent exhibited efficacy and safety comparable with the XIENCE Alpine® stent, supporting the need for further clinical studies on the TIGEREVOLUTION® stent.
9.2021 Korean Thyroid Imaging Reporting and Data System and Imaging-Based Management of Thyroid Nodules: Korean Society of Thyroid Radiology Consensus Statement and Recommendations
Eun Ju HA ; Sae Rom CHUNG ; Dong Gyu NA ; Hye Shin AHN ; Jin CHUNG ; Ji Ye LEE ; Jeong Seon PARK ; Roh-Eul YOO ; Jung Hwan BAEK ; Sun Mi BAEK ; Seong Whi CHO ; Yoon Jung CHOI ; Soo Yeon HAHN ; So Lyung JUNG ; Ji-hoon KIM ; Seul Kee KIM ; Soo Jin KIM ; Chang Yoon LEE ; Ho Kyu LEE ; Jeong Hyun LEE ; Young Hen LEE ; Hyun Kyung LIM ; Jung Hee SHIN ; Jung Suk SIM ; Jin Young SUNG ; Jung Hyun YOON ; Miyoung CHOI
Korean Journal of Radiology 2021;22(12):2094-2123
Incidental thyroid nodules are commonly detected on ultrasonography (US). This has contributed to the rapidly rising incidence of low-risk papillary thyroid carcinoma over the last 20 years. The appropriate diagnosis and management of these patients is based on the risk factors related to the patients as well as the thyroid nodules. The Korean Society of Thyroid Radiology (KSThR) published consensus recommendations for US-based management of thyroid nodules in 2011 and revised them in 2016. These guidelines have been used as the standard guidelines in Korea. However, recent advances in the diagnosis and management of thyroid nodules have necessitated the revision of the original recommendations. The task force of the KSThR has revised the Korean Thyroid Imaging Reporting and Data System and recommendations for US lexicon, biopsy criteria, US criteria of extrathyroidal extension, optimal thyroid computed tomography protocol, and US follow-up of thyroid nodules before and after biopsy. The biopsy criteria were revised to reduce unnecessary biopsies for benign nodules while maintaining an appropriate sensitivity for the detection of malignant tumors in small (1–2 cm) thyroid nodules. The goal of these recommendations is to provide the optimal scientific evidence and expert opinion consensus regarding US-based diagnosis and management of thyroid nodules.
10.Clopidogrel versus Aspirin after Dual Antiplatelet Therapy in Acute Myocardial Infarction Patients Undergoing Drug-Eluting Stenting
Doo Sun SIM ; Myung Ho JEONG ; Hyo Soo KIM ; Hyeon Cheol GWON ; Ki Bae SEUNG ; Seung Woon RHA ; Shung Chull CHAE ; Chong Jin KIM ; Kwang Soo CHA ; Jong Seon PARK ; Jung Han YOON ; Jei Keon CHAE ; Seung Jae JOO ; Dong Ju CHOI ; Seung Ho HUR ; In Whan SEONG ; Myeong Chan CHO ; Doo Il KIM ; Seok Kyu OH ; Tae Hoon AHN ; Jin Yong HWANG ;
Korean Circulation Journal 2020;50(2):120-129
BACKGROUND AND OBJECTIVES: There is a paucity of data regarding the benefit of clopidogrel monotherapy after dual antiplatelet therapy (DAPT) in patients treated with drug-eluting stents (DES). This study compared outcome between clopidogrel versus aspirin as monotherapy after DES for acute myocardial infarction (MI).METHODS: From Korea Acute Myocardial Infarction Registry-National Institute of Health database, 1,819 patients treated with DES who were switched to monotherapy with clopidogrel (n=534) or aspirin (n=1,285) after uneventful 12-month DAPT were analyzed. The primary endpoint was net adverse clinical events (NACE), defined as a composite of death from any cause, MI, repeat percutaneous coronary intervention (PCI), stent thrombosis, ischemic stroke, or major bleeding during the period from 12 to 24 months.RESULTS: After adjustment using inverse probability of treatment weighting, patients who received clopidogrel, compared with those treated with aspirin, had a similar incidence of NACE (0.7% and 0.7%; hazard ratio, 1.06; 95% confidence interval, 0.31–3.60; p=0.923). The 2 groups had similar rates of death from any cause (0.1% in each group, p=0.789), MI (0.3% and 0.1%, respectively; p=0.226), repeat PCI (0.1% and 0.3%, respectively; p=0.548), stent thrombosis (0.1% and 0%, respectively; p=0.121), major bleeding (0.2% in each group, p=0.974), and major adverse cardiovascular and cerebrovascular events (0.5% in each group, p=0.924).CONCLUSIONS: Monotherapy with clopidogrel, compared to aspirin, after DAPT showed similar clinical outcomes in patients with acute MI treated with DES.
Aspirin
;
Drug-Eluting Stents
;
Hemorrhage
;
Humans
;
Incidence
;
Korea
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
;
Platelet Aggregation Inhibitors
;
Stents
;
Stroke
;
Thrombosis

Result Analysis
Print
Save
E-mail