1.Current Clinical Perspectives on Rosacea Management: Insights From a Korean Multicenter Expert Opinion Survey
Bo Ri KIM ; Sejin OH ; Ju Hee HAN ; Jimyung SEO ; Hyun-Min SEO ; Soon-Hyo KWON ; Hoon CHOI ; Jung U SHIN ; Jae We CHO ; Boncheol Leo GOO ; Jung-Im NA ; Dong Hun LEE ; Chun Pill CHOI ; HaeWoong LEE ; Joo Yeon KO ; Hwa Jung RYU ; Nark-Kyoung RHO ; Hyunjo KIM ; Ga-Young LEE ; Jong Hee LEE ; Nala SHIN ; Sang Ju LEE ; Suk Bae SEO ; Geun Soo LEE ; Hei Sung KIM ; Chang-Hun HUH
Annals of Dermatology 2026;38(1):42-50
Background:
Rosacea is a chronic inflammatory skin disorder characterized by erythema, papules, ocular symptoms, and heightened sensitivity. Patients with neurogenic symptoms such as burning or stinging remain particularly difficult to manage. Current guidelines often underrepresent energy-based devices (EBDs), pigmentary sequelae, psychosocial burden, and ocular comorbidities.
Objective:
To examine Korean dermatologists’ expert perspectives on rosacea management, focusing on skin sensitivity, neurogenic symptoms, pigmentary changes, psychosocial impact, ocular involvement, and EBD use.
Methods:
A web-based, 29-item survey was administered to 25 board-certified Korean dermatologists (May–June 2025). Quantitative and qualitative responses were analyzed.
Results:
Erythematotelangiectatic and papulopustular phenotypes with sensitivity skin predominated. EBDs (pulsed dye laser, intense pulsed light) were frequently used but limited by cost and sensitivity issues. Neurogenic symptoms were recognized but rarely treated with neuromodulators. Post-inflammatory hyperpigmentation was infrequent, yet monitoring was inconsistent.Psychosocial and ocular aspects were acknowledged but seldomly systematically addressed.Respondents expressed interest in emerging adjunctive treatments such as cold plasma, skin boosters, and holistic care approaches.
Conclusion
Korean dermatologists adopt individualized strategies for rosacea, yet practice gaps remain regarding neurogenic symptoms, pigmentary complications, and psychosocial and ocular comorbidities. Findings support the need for updated multidisciplinary, phenotype-driven guidelines aligned with real-world practice.
2.Detection Ability of Quality of Life Changes and Responsiveness of the KOQUSS-40 and the EORTC QLQ-C30/STO22 in Patients Who Underwent Gastrectomy: A Prospective Comparative Study
Bang Wool EOM ; Keun Won RYU ; Ji Yeong AN ; Yun-Suhk SUH ; In CHO ; Sung Geun KIM ; Ji-Ho PARK ; Hoon HUR ; Hyung-Ho KIM ; Sang-Hoon AHN ; Sun-Hwi HWANG ; Hong Man YOON ; Ki Bum PARK ; Hyoung-Il KIM ; In-Gyu KWON ; Han-Kwang YANG ; Byoung-Jo SUH ; Sang-Ho JEONG ; Tae-Han KIM ; Oh Kyoung KWON ; Hye-Seong AHN ; Ji Yeon PARK ; Ki Young YOON ; Myoung Won SON ; Seong-Ho KONG ; Young-Gil SON ; Geum Jong SONG ; Jong Hyuk YUN ; Jung-Min BAE ; Do Joong PARK ; Sol LEE ; Jun-Young YANG ; Kyung Won SEO ; You-Jin JANG ; So Hyun KANG ; Joongyub LEE ; Hyuk-Joon LEE ;
Cancer Research and Treatment 2026;58(1):221-231
Purpose:
The aim of this study is to compare the detection ability of quality of life (QoL) changes and responsiveness of the KOrean QUality of life in Stomach cancer patients Study group (KOQUSS)-40 and European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ).
Materials and Methods:
A multicenter prospective observational study was conducted to evaluate QoL changes after various gastrectomies between January 2021 and April 2022. Participants were instructed to complete the KOQUSS-40 and EORTC QLQ-C30/STO22 preoperatively and at 1, 3, 6, and 12 months postoperatively. QoL changes over time and QoL responsiveness were assessed for each questionnaire.
Results:
Data from 491 patients who underwent curative gastrectomy for gastric cancer at 22 institutions were analyzed. The summary scores of the KOQUSS-40 and EORTC QLQ-STO22 showed significant differences between the total and proximal gastrectomy groups (p=0.044 and p=0.038, respectively), but no difference was observed for the EORTC QLQ-C30. Dysphagia on the KOQUSS-40 was significantly different between the total and proximal gastrectomy groups (p=0.031); however, dysphagia on the EORTC QLQ-STO22 did not differ. The responsiveness of the KOQUSS-40 was similar to that of the EORTC QLQ in patients who experienced ≥ 10% body weight loss, but approximately 10% less in patients receiving adjuvant chemotherapy than the EORTC QLQ.
Conclusion
KOQUSS-40 has several advantages over EORTC QLQ-C30/STO22 when comparing QoL between the total and proximal gastrectomy groups. The findings provide information for researchers investigating the QoL of patients who have undergone curative gastrectomy for gastric cancer.
3.Health Effects of Sugar-Sweetened and Artificially Sweetened Beverages: Umbrella Review and Evidence-Based Consensus Statement of the Korean Diabetes Association and the Korean Nutrition Society
Jong Han CHOI ; SuJin SONG ; Soo Kyoung KIM ; Jae Won CHO ; Jae Hyun BAE ; Shinje MOON ; Jeong Hyun LIM ; YeonHee LEE ; Ji-Yun HWANG ; YoonJu SONG ; Sang Soo KIM
Diabetes & Metabolism Journal 2026;50(1):32-46
Background:
Excess intake of added sugars contributes to obesity, type 2 diabetes mellitus (T2DM), cardiovascular disease (CVD), and premature mortality. Sugar-sweetened beverages (SSBs), the main source of added sugars, are consistently linked to adverse outcomes. Artificially sweetened beverages (ASBs) have been suggested as short-term substitutes, but evidence regarding benefits and harms remains inconclusive, and guidance is lacking.
Methods:
This consensus statement draws on a structured evidence review combining two approaches: an updated meta-analysis of randomized controlled trials (RCTs) assessing short- to intermediate-term effects of replacing SSBs with ASBs on weight and metabolic outcomes; and an umbrella review of systematic reviews of cohort studies evaluating long-term associations of SSBs and ASBs with major outcomes, including mortality, CVD, and T2DM.
Results:
In 14 RCTs (3–76 weeks), replacing SSBs with ASBs produced modest reductions in body weight (–0.73 kg) and body fat (–0.72%), with inconsistent effects on glycemic and cardiometabolic markers. Evidence from 20 systematic reviews of cohorts (up to 34 years follow-up) showed that higher intake of both SSBs and ASBs was associated with increased risks of T2DM, CVD, and mortality, with relative risks for ASBs similar to those for SSBs.
Conclusion
ASBs may serve as a short-term substitution for individuals with high SSB intake, particularly those at elevated metabolic risk. However, regular or long-term use is not recommended due to uncertain safety and potential reinforcement of sweet preference. Public health strategies should emphasize reducing both SSBs and ASBs, prioritizing water and unsweetened beverages as the ultimate goal.
4.Digital Phenotyping of Rare Endocrine Diseases Across International Data Networks and the Effect of Granularity of Original Vocabulary
Seunghyun LEE ; Namki HONG ; Gyu Seop KIM ; Jing LI ; Xiaoyu LIN ; Sarah SEAGER ; Sungjae SHIN ; Kyoung Jin KIM ; Jae Hyun BAE ; Seng Chan YOU ; Yumie RHEE ; Sin Gon KIM
Yonsei Medical Journal 2025;66(3):187-194
Purpose:
Rare diseases occur in <50 per 100000 people and require lifelong management. However, essential epidemiological data on such diseases are lacking, and a consecutive monitoring system across time and regions remains to be established. Standardized digital phenotypes are required to leverage an international data network for research on rare endocrine diseases. We developed digital phenotypes for rare endocrine diseases using the observational medical outcome partnership common data model.
Materials and Methods:
Digital phenotypes of three rare endocrine diseases (medullary thyroid cancer, hypoparathyroidism, pheochromocytoma/paraganglioma) were validated across three databases that use different vocabularies: Severance Hospital’s electronic health record from South Korea; IQVIA’s United Kingdom (UK) database for general practitioners; and IQVIA’s United States (US) hospital database for general hospitals. We estimated the performance of different digital phenotyping methods based on International Classification of Diseases (ICD)-10 in the UK and the US or systematized nomenclature of medicine clinical terms (SNOMED CT) in Korea.
Results:
The positive predictive value of digital phenotyping was higher using SNOMED CT-based phenotyping than ICD-10-based phenotyping for all three diseases in Korea (e.g., pheochromocytoma/paraganglioma: ICD-10, 58%–62%; SNOMED CT, 89%). Estimated incidence rates by digital phenotyping were as follows: medullary thyroid cancer, 0.34–2.07 (Korea), 0.13–0.30 (US); hypoparathyroidism, 0.40–1.20 (Korea), 0.59–1.01 (US), 0.00–1.78 (UK); and pheochromocytoma/paraganglioma, 0.95–1.67 (Korea), 0.35–0.77 (US), 0.00–0.49 (UK).
Conclusion
Our findings demonstrate the feasibility of developing digital phenotyping of rare endocrine diseases and highlight the importance of implementing SNOMED CT in routine clinical practice to provide granularity for research.
6.Prospective Multicenter Observational Study on Postoperative Quality of Life According to Type of Gastrectomy for Gastric Cancer
Sung Eun OH ; Yun-Suhk SUH ; Ji Yeong AN ; Keun Won RYU ; In CHO ; Sung Geun KIM ; Ji-Ho PARK ; Hoon HUR ; Hyung-Ho KIM ; Sang-Hoon AHN ; Sun-Hwi HWANG ; Hong Man YOON ; Ki Bum PARK ; Hyoung-Il KIM ; In Gyu KWON ; Han-Kwang YANG ; Byoung-Jo SUH ; Sang-Ho JEONG ; Tae-Han KIM ; Oh Kyoung KWON ; Hye Seong AHN ; Ji Yeon PARK ; Ki Young YOON ; Myoung Won SON ; Seong-Ho KONG ; Young-Gil SON ; Geum Jong SONG ; Jong Hyuk YUN ; Jung-Min BAE ; Do Joong PARK ; Sol LEE ; Jun-Young YANG ; Kyung Won SEO ; You-Jin JANG ; So Hyun KANG ; Bang Wool EOM ; Joongyub LEE ; Hyuk-Joon LEE ;
Journal of Gastric Cancer 2025;25(2):382-399
Purpose:
This study evaluated the postoperative quality of life (QoL) after various types of gastrectomy for gastric cancer.
Materials and Methods:
A multicenter prospective observational study was conducted in Korea using the Korean Quality of Life in Stomach Cancer Patients Study (KOQUSS)-40, a new QoL assessment tool focusing on postgastrectomy syndrome. Overall, 496 patients with gastric cancer were enrolled, and QoL was assessed at 5 time points: preoperatively and at 1, 3, 6, and 12 months after surgery.
Results:
Distal gastrectomy (DG) and pylorus-preserving gastrectomy (PPG) showed significantly better outcomes than total gastrectomy (TG) and proximal gastrectomy (PG) with regard to total score, indigestion, and dysphagia. DG, PPG, and TG also showed significantly better outcomes than PG in terms of dumping syndrome and worry about cancer. Postoperative QoL did not differ significantly according to anastomosis type in DG, except for Billroth I anastomosis, which achieved better bowel habit change scores than the others. No domains differed significantly when comparing double tract reconstruction and esophagogastrostomy after PG. The total QoL score correlated significantly with postoperative body weight loss (more than 10%) and extent of resection (P<0.05 for both).Reflux as assessed by KOQUSS-40 did not correlate significantly with reflux observed on gastroscopy 1 year postoperatively (P=0.064).
Conclusions
Our prospective observation using KOQUSS-40 revealed that DG and PPG lead to better QoL than TG and PG. Further study is needed to compare postoperative QoL according to anastomosis type in DG and PG.
7.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
8.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
9.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
10.Environmental disease monitoring by regional Environmental Health Centers in Korea: a narrative review
Myung-Sook PARK ; Hwan-Cheol KIM ; Woo Jin KIM ; Yun-Chul HONG ; Won-Jun CHOI ; Seock-Yeon HWANG ; Jiho LEE ; Young-Seoub HONG ; Yong-Dae KIM ; Seong-Chul HONG ; Joo Hyun SUNG ; Inchul JEONG ; Kwan LEE ; Won-Ju PARK ; Hyun-Joo BAE ; Seong-Yong YOON ; Cheolmin LEE ; Kyoung Sook JEONG ; Sanghyuk BAE ; Jinhee CHOI ; Ho-Hyun KIM
The Ewha Medical Journal 2025;48(1):e3-
This study explores the development, roles, and key initiatives of the Regional Environmental Health Centers in Korea, detailing their evolution through four distinct phases and their impact on environmental health policy and local governance. It chronicles the establishment and transformation of these centers from their inception in May 2007, through four developmental stages. Originally named Environmental Disease Research Centers, they were subsequently renamed Environmental Health Centers following legislative changes. The analysis includes the expansion in the number of centers, the transfer of responsibilities to local governments, and the launch of significant projects such as the Korean Children’s Environmental Health Study (Ko-CHENS ). During the initial phase (May 2007–February 2009), the 10 centers concentrated on research-driven activities, shifting from a media-centered to a receptor-centered approach. In the second phase, prompted by the enactment of the Environmental Health Act, six additional centers were established, broadening their scope to address national environmental health issues. The third phase introduced Ko-CHENS, a 20-year national cohort project designed to influence environmental health policy by integrating research findings into policy frameworks. The fourth phase marked a decentralization of authority, empowering local governments and redefining the centers' roles to focus on regional environmental health challenges. The Regional Environmental Health Centers have significantly evolved and now play a crucial role in addressing local environmental health issues and supporting local government policies. Their capacity to adapt and respond to region-specific challenges is essential for the effective implementation of environmental health policies, reflecting geographical, socioeconomic, and demographic differences.

Result Analysis
Print
Save
E-mail