1.Clinical Practice Guideline for the Prehospital Stage of Acute Stroke : III. Initial Decision for Primary Treatment in Subarachnoid Hemorrhage
Jae Sang OH ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Yuna JO ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Dae-Won KIM ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):35-50
Subarachnoid hemorrhage (SAH) is a stroke subtype with high mortality and poor functional outcomes. Prompt occlusion of a ruptured aneurysm at an early stage is crucial to prevent rebleeding, which can result in even higher mortality and more severe disabilities. The most critical initial decision in SAH management is the choice of treatment method with surgical clipping or endovascular coiling. We aimed to develop an evidence-based clinical guideline to select the optimal initial treatment in patients with SAH. We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer two population, intervention, comparison, outcome questions comparing clipping and coiling. The risk of bias was assessed using ROB 2.0 and the Newcastle-Ottawa Scale. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcome and mortality. We included six randomized control trials (RCTs) and 58 observational studies. Meta-analysis of RCTs showed that coiling improved functional outcomes compared to clipping (odds ratio [OR], 0.91; 95% confidence interval [CI], 0.86–0.97). No significant mortality difference was observed in RCTs (OR, 1.38; 95% CI, 0.91–2.09), but non-RCTs favored clipping for reduced mortality (OR, 0.77; 95% CI, 0.69–0.86). However, it is difficult to generalize these findings to all clinical situations, as patients with SAH have a highly variable clinical course. Final treatment decision should be tailored to the individual patient’s status, including aneurysm location, morphology, and the expertise available at the treatment center. Such decisions are best made by specialists such as a board-certified physician and should be explained to the patient and their caregivers, along with the rationale for selecting the most appropriate treatment at the given hospital. Korea has many certified endovascular neurosurgeons, cerebrovascular surgeons, and certified cerebrovascular centers. Proper selection of the most suitable treatment method by certified physicians and centers would greatly benefit patient outcomes and healthcare professionals.
2.Clinical Practice Guidelines for the Prehospital Stage of Acute Stroke in Korea II : Transport Decisions for Patients with Acute Ischemic Stroke
Jae Sang OH ; Yuna JO ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):23-34
The mothership (MS) model, where patients are directly transferred to a thrombectomy-capable center, and the drip-and-ship (DS) model, where thrombolysis is initiated at the nearest primary stroke center before transfer for thrombectomy, are the primary transport modes for patients with stroke. We aimed to establish guidelines for selecting the appropriate transfer strategy based on emergent large vessel occlusion (LVO). We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer three Population, Intervention, Comparison, and Outcome questions comparing MS and DS models. The risk of bias was assessed using the Newcastle-Ottawa Scale. Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcomes, mortality, and successful recanalization. Twenty-six non-randomized controlled studies showed that the MS model improved good functional outcomes by approximately 14% compared with the DS model (odds ratio [OR], 1.14; 95% confidence interval [CI], 1.00–1.30). Fifteen studies reported that mortality in the MS and DS models showed no significant differences (OR, 0.97; 95% CI, 0.84–1.11). Twenty-four studies revealed no significant difference in successful recanalization between the MS and DS models (OR, 0.87; 95% CI, 0.68–1.10). The MS model should be considered first to improve the functional outcome of patients with LVO. However, if thrombectomy cannot be performed immediately after thrombolysis, or if a thrombectomy-enabled hospital is not nearby, the DS model should be considered by stroke specialists depending on transportation time and regional factors. We suggest a mixed approach with the DS model based on specific circumstances or regions to ensure the optimum treatment of patients with acute ischemic stroke (AIS). Appropriate transport for patients with LVO improves the prognosis of AIS.
3.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
8.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
9.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
10.Lower Atrial Fibrillation Risk With Sodium-Glucose Cotransporter 2Inhibitors Than With Dipeptidyl Peptidase-4 Inhibitors in Individuals With Type 2 Diabetes: A Nationwide Cohort Study
Min KIM ; Kyoung Hwa HA ; Junyoung LEE ; Sangshin PARK ; Kyeong Seok OH ; Dae-Hwan BAE ; Ju Hee LEE ; Sang Min KIM ; Woong Gil CHOI ; Kyung-Kuk HWANG ; Dong-Woon KIM ; Myeong-Chan CHO ; Dae Jung KIM ; Jang-Whan BAE
Korean Circulation Journal 2024;54(5):256-267
Background and Objectives:
Accumulating evidence shows that sodium-glucose cotransporter 2 inhibitors (SGLT2is) reduce adverse cardiovascular outcomes. However, whether SGLT2i, compared with other antidiabetic drugs, reduce the new development of atrial fibrillation (AF) is unclear. In this study, we compared SGLT2i with dipeptidyl peptidase-4 inhibitors (DPP-4is) in terms of reduction in the risk of AF in individuals with type 2 diabetes.
Methods:
We included 42,786 propensity score-matched pairs of SGLT2i and DPP-4i users without previous AF diagnosis using the Korean National Health Insurance Service database between May 1, 2016, and December 31, 2018.
Results:
During a median follow-up of 1.3 years, SGLT2i users had a lower incidence of AF than DPP-4i users (1.95 vs. 2.65 per 1,000 person-years; hazard ratio [HR], 0.73; 95% confidence interval [CI], 0.55–0.97; p=0.028]). In individuals without heart failure, SGLT2i users was associated with a decreased risk of AF incidence (HR, 0.70; 95% CI, 0.52–0.94; p=0.019) compared to DPP-4i users. However, individuals with heart failure, SGLT2i users was not significantly associated with a change in risk (HR, 1.04; 95% CI, 0.44–2.44; p=0.936).
Conclusions
In this nationwide cohort study of individuals with type 2 diabetes, treatment with SGLT2i was associated with a lower risk of AF compared with treatment with DPP-4i.

Result Analysis
Print
Save
E-mail