1.Increased risk of osteoporosis among thyroid cancer survivors: the influence of postoperative levothyroxine therapy in a nationwide cohort study
Young Bin CHO ; Kyoung Sik PARK
Annals of Surgical Treatment and Research 2026;110(2):84-91
Purpose:
Our study aimed to assess whether individuals diagnosed with thyroid cancer face an elevated risk of osteoporosis compared to control subjects in a large-scale study. Additionally, we intended to identify potential risk factors associated with osteoporosis in patients with thyroid cancer.
Methods:
We used the National Health Insurance Service-National Sample Cohort of South Korea. We included 1,313 patients diagnosed with thyroid cancer and 3,939 control subjects without cancer. Following propensity score matching at a 1:3 ratio, Cox proportional hazards regression and stratification analyses were used to estimate the risk of osteoporosis in patients with thyroid cancer, incorporating multivariate adjustments. A restricted cubic spline model was employed to evaluate dose-response relationships.
Results:
Thyroid cancer patients exhibited a higher likelihood of developing osteoporosis than the control group (hazard ratio [HR], 6.59; P < 0.001). In the stratification analyses, younger thyroid cancer patients, females, and those who did not have dyslipidemia were more susceptible to osteoporosis than their counterparts in the control group. Furthermore, the administration of levothyroxine has been linked to an elevated risk of osteoporosis (HR, 2.33; P = 0.044). A restricted cubic spline analysis demonstrated a significant overall association between exposure and outcome (P for total = 0.007, P for nonlinear = 0.573), indicating an essentially linear relationship.
Conclusion
Thyroid cancer patients showed a higher risk of osteoporosis compared to matched controls. Stratified analyses suggested that levothyroxine therapy may be a risk factor for osteoporosis. These findings highlight the importance of individualized treatment approaches.
2.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
3.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
4.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
5.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
6.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
7.Advancements and Clinical Strategies in Parathyroid Transplantation:A Comprehensive Review
Sun Ae HWANG ; Ik Jin YUN ; Kyoung Sik PARK
Journal of Endocrine Surgery 2025;25(1):1-12
Parathyroid transplantation is an important therapeutic option for individuals experiencing hypoparathyroidism, often resulting from surgical interventions like thyroidectomy. This review aims to provide a comprehensive overview of advancements and clinical strategies in parathyroid transplantation. A thorough examination of the latest research advancements and clinical practices in parathyroid transplantation was conducted. The review emphasizes innovations in tissue preservation methods, investigations into alternative transplant locations, progress in immunosuppressive strategies, the potential of stem cell-based therapies, and the use of genetic engineering techniques. Parathyroid transplantation demonstrates clinical utility in various contexts, including hypoparathyroidism following thyroidectomy, chronic kidney disease, repeat thyroid surgeries, and allotransplantation.Long-term management strategies and improvements in patients’ quality of life are also considered. Parathyroid transplantation holds significant promise as a treatment for hypoparathyroidism. Further research and clinical trials are warranted to optimize outcomes.
8.Evidence‑based Korean guidelines for the clinical management of multiple myeloma: addressing 12 key clinical questions
Sung‑Hoon JUNG ; Youngil KOH ; Min Kyoung KIM ; Jin Seok KIM ; Joon Ho MOON ; Chang‑Ki MIN ; Dok Hyun YOON ; Sung‑Soo YOON ; Je‑Jung LEE ; Chae Moon HONG ; Ka‑Won KANG ; Jihyun KWON ; Kyoung Ha KIM ; Dae Sik KIM ; Sung Yong KIM ; Sung‑Hyun KIM ; Yu Ri KIM ; Young Rok DO ; Yeung‑Chul MUN ; Sung‑Soo PARK ; Young Hoon PARK ; Ho Jin SHIN ; Hyeon‑Seok EOM ; Sang Eun YOON ; Sang Mee HWANG ; Won Sik LEE ; Myung‑won LEE ; Jun Ho YI ; Ji Yun LEE ; Ji Hyun LEE ; Ho Sup LEE ; Sung‑Nam LIM ; Jihyang LIM ; Ho‑Young YHIM ; Yoon Hwan CHANG ; Jae‑Cheol JO ; Jinhyun CHO ; Hyungwoo CHO ; Yoon Seok CHOI ; Hee jeong CHO ; Ari AHN ; Jong Han CHOI ; Hyun Jung KIM ; Kihyun KIM
Blood Research 2025;60():9-
Multiple myeloma (MM), a hematological malignancy, is characterized by malignant plasma cell proliferation in the bone marrow. Recent treatment advances have significantly improved patient outcomes associated with MM.In this study, we aimed to develop comprehensive, evidence-based guidelines for the diagnosis, prognosis, and treat‑ ment of MM. We identified 12 key clinical questions essential for MM management, guiding the extensive literature review and meta-analysis of the study. Our guidelines provide evidence-based recommendations by integrating patient preferences with survey data. These recommendations include current and emerging diagnostic tools, thera‑ peutic agents, and treatment strategies. By prioritizing a patient-centered approach and rigorous data analysis, these guidelines were developed to enhance MM management, both in Korea and globally.
9.Efficacy and Safety of Lurasidone vs. Quetiapine XR in Acutely Psychotic Patients With Schizophrenia in Korea: A Randomized, Double-Blind, Active-Controlled Trial
Se Hyun KIM ; Do-Un JUNG ; Do Hoon KIM ; Jung Sik LEE ; Kyoung-Uk LEE ; Seunghee WON ; Bong Ju LEE ; Sung-Gon KIM ; Sungwon ROH ; Jong-Ik PARK ; Minah KIM ; Sung Won JUNG ; Hong Seok OH ; Han-yong JUNG ; Sang Hoon KIM ; Hyun Seung CHEE ; Jong-Woo PAIK ; Kyu Young LEE ; Soo In KIM ; Seung-Hwan LEE ; Eun-Jin CHEON ; Hye-Geum KIM ; Heon-Jeong LEE ; In Won CHUNG ; Joonho CHOI ; Min-Hyuk KIM ; Seong-Jin CHO ; HyunChul YOUN ; Jhin-Goo CHANG ; Hoo Rim SONG ; Euitae KIM ; Won-Hyoung KIM ; Chul Eung KIM ; Doo-Heum PARK ; Byung-Ook LEE ; Jungsun LEE ; Seung-Yup LEE ; Nuree KANG ; Hee Yeon JUNG
Psychiatry Investigation 2024;21(7):762-771
Objective:
This study was performed to evaluate the efficacy and safety of lurasidone (160 mg/day) compared to quetiapine XR (QXR; 600 mg/day) in the treatment of acutely psychotic patients with schizophrenia.
Methods:
Patients were randomly assigned to 6 weeks of double-blind treatment with lurasidone 160 mg/day (n=105) or QXR 600 mg/day (n=105). Primary efficacy measure was the change from baseline to week 6 in Positive and Negative Syndrome Scale (PANSS) total score and Clinical Global Impressions severity (CGI-S) score. Adverse events, body measurements, and laboratory parameters were assessed.
Results:
Lurasidone demonstrated non-inferiority to QXR on the PANSS total score. Adjusted mean±standard error change at week 6 on the PANSS total score was -26.42±2.02 and -27.33±2.01 in the lurasidone and QXR group, respectively. The mean difference score was -0.91 (95% confidence interval -6.35–4.53). The lurasidone group showed a greater reduction in PANSS total and negative subscale on week 1 and a greater reduction in end-point CGI-S score compared to the QXR group. Body weight, body mass index, and waist circumference in the lurasidone group were reduced, with significantly lower mean change compared to QXR. Endpoint changes in glucose, cholesterol, triglycerides, and low-density lipoprotein levels were also significantly lower. The most common adverse drug reactions with lurasidone were akathisia and nausea.
Conclusion
Lurasidone 160 mg/day was found to be non-inferior to QXR 600 mg/day in the treatment of schizophrenia with comparable efficacy and tolerability. Adverse effects of lurasidone were generally tolerable, and beneficial effects on metabolic parameters can be expected.
10.Geriatric risk model for older patients with diffuse large B-cell lymphoma (GERIAD): a prospective multicenter cohort study
Ho-Young YHIM ; Yong PARK ; Jeong-A KIM ; Ho-Jin SHIN ; Young Rok DO ; Joon Ho MOON ; Min Kyoung KIM ; Won Sik LEE ; Dae Sik KIM ; Myung-Won LEE ; Yoon Seok CHOI ; Seong Hyun JEONG ; Kyoung Ha KIM ; Jinhang KIM ; Chang-Hoon LEE ; Ga-Young SONG ; Deok-Hwan YANG ; Jae-Yong KWAK
The Korean Journal of Internal Medicine 2024;39(3):501-512
Background/Aims:
Optimal risk stratification based on simplified geriatric assessment to predict treatment-related toxicity and survival needs to be clarified in older patients with diffuse large B-cell lymphoma (DLBCL).
Methods:
This multicenter prospective cohort study enrolled newly diagnosed patients with DLBCL (≥ 65 yr) between September 2015 and April 2018. A simplified geriatric assessment was performed at baseline using Activities of Daily Living (ADL), Instrumental ADL (IADL), and Charlson’s Comorbidity Index (CCI). The primary endpoint was event-free survival (EFS).
Results:
The study included 249 patients, the median age was 74 years (range, 65-88), and 125 (50.2%) were female. In multivariable Cox analysis, ADL, IADL, CCI, and age were independent factors for EFS; an integrated geriatric score was derived and the patients stratified into three geriatric categories: fit (n = 162, 65.1%), intermediate-fit (n = 25, 10.0%), and frail (n = 62, 24.9%). The established geriatric model was significantly associated with EFS (fit vs. intermediate-fit, HR 2.61, p < 0.001; fit vs. frail, HR 4.61, p < 0.001) and outperformed each covariate alone or in combination. In 87 intermediate-fit or frail patients, the relative doxorubicin dose intensity (RDDI) ≥ 62.4% was significantly associated with worse EFS (HR, 2.15, 95% CI 1.30–3.53, p = 0.002). It was related with a higher incidence of grade ≥ 3 symptomatic non-hematologic toxicities (63.2% vs. 27.8%, p < 0.001) and earlier treatment discontinuation (34.5% vs. 8.0%, p < 0.001) in patients with RDDI ≥ 62.4% than in those with RDDI < 62.4%.
Conclusions
This model integrating simplified geriatric assessment can risk-stratify older patients with DLBCL and identify those who are highly vulnerable to standard dose-intensity chemoimmunotherapy.

Result Analysis
Print
Save
E-mail