1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Lower Atrial Fibrillation Risk With Sodium-Glucose Cotransporter 2Inhibitors Than With Dipeptidyl Peptidase-4 Inhibitors in Individuals With Type 2 Diabetes: A Nationwide Cohort Study
Min KIM ; Kyoung Hwa HA ; Junyoung LEE ; Sangshin PARK ; Kyeong Seok OH ; Dae-Hwan BAE ; Ju Hee LEE ; Sang Min KIM ; Woong Gil CHOI ; Kyung-Kuk HWANG ; Dong-Woon KIM ; Myeong-Chan CHO ; Dae Jung KIM ; Jang-Whan BAE
Korean Circulation Journal 2024;54(5):256-267
Background and Objectives:
Accumulating evidence shows that sodium-glucose cotransporter 2 inhibitors (SGLT2is) reduce adverse cardiovascular outcomes. However, whether SGLT2i, compared with other antidiabetic drugs, reduce the new development of atrial fibrillation (AF) is unclear. In this study, we compared SGLT2i with dipeptidyl peptidase-4 inhibitors (DPP-4is) in terms of reduction in the risk of AF in individuals with type 2 diabetes.
Methods:
We included 42,786 propensity score-matched pairs of SGLT2i and DPP-4i users without previous AF diagnosis using the Korean National Health Insurance Service database between May 1, 2016, and December 31, 2018.
Results:
During a median follow-up of 1.3 years, SGLT2i users had a lower incidence of AF than DPP-4i users (1.95 vs. 2.65 per 1,000 person-years; hazard ratio [HR], 0.73; 95% confidence interval [CI], 0.55–0.97; p=0.028]). In individuals without heart failure, SGLT2i users was associated with a decreased risk of AF incidence (HR, 0.70; 95% CI, 0.52–0.94; p=0.019) compared to DPP-4i users. However, individuals with heart failure, SGLT2i users was not significantly associated with a change in risk (HR, 1.04; 95% CI, 0.44–2.44; p=0.936).
Conclusions
In this nationwide cohort study of individuals with type 2 diabetes, treatment with SGLT2i was associated with a lower risk of AF compared with treatment with DPP-4i.
9.Interpretation of Complete Tumor Response on MRI Following Chemoradiotherapy of Rectal Cancer:Inter-Reader Agreement and Associated Factors in Multi-Center Clinical Practice
Hae Young KIM ; Seung Hyun CHO ; Jong Keon JANG ; Bohyun KIM ; Chul-min LEE ; Joon Seok LIM ; Sung Kyoung MOON ; Soon Nam OH ; Nieun SEO ; Seong Ho PARK
Korean Journal of Radiology 2024;25(4):351-362
Objective:
To measure inter-reader agreement and identify associated factors in interpreting complete response (CR) on magnetic resonance imaging (MRI) following chemoradiotherapy (CRT) for rectal cancer.
Materials and Methods:
This retrospective study involved 10 readers from seven hospitals with experience of 80–10210 cases, and 149 patients who underwent surgery after CRT for rectal cancer. Using MRI-based tumor regression grading (mrTRG) and methods employed in daily practice, the readers independently assessed mrTRG, CR on T2-weighted images (T2WI) denoted as mrCR T2W, and CR on all images including diffusion-weighted images (DWI) denoted as mrCRoverall. The readers described their interpretation patterns and how they utilized DWI. Inter-reader agreement was measured using multi-rater kappa, and associated factors were analyzed using multivariable regression. Correlation between sensitivity and specificity of each reader was analyzed using Spearman coefficient.
Results:
The mrCR T2W and mrCRoverall rates varied widely among the readers, ranging 18.8%–40.3% and 18.1%–34.9%, respectively. Nine readers used DWI as a supplement sequence, which modified interpretations on T2WI in 2.7% of cases (36/1341 [149 patients x 9 readers]) and mostly (33/36) changed mrCR T2W to non-mrCRoverall. The kappa values for mrTRG, mrCR T2W, and mrCRoverall were 0.56 (95% confidence interval: 0.49, 0.62), 0.55 (0.52, 0.57), and 0.54 (0.51, 0.57), respectively.No use of rectal gel, larger initial tumor size, and higher initial cT stage exhibited significant association with a higher interreader agreement for assessing mrCRoverall (P ≤ 0.042). Strong negative correlations were observed between the sensitivity and specificity of individual readers (coefficient, -0.718 to -0.963; P ≤ 0.019).
Conclusion
Inter-reader agreement was moderate for assessing CR on post-CRT MRI. Readers’ varying standards on MRI interpretation (i.e., threshold effect), along with the use of rectal gel, initial tumor size, and initial cT stage, were significant factors associated with inter-reader agreement.
10.Efficacy and Safety of Lurasidone vs. Quetiapine XR in Acutely Psychotic Patients With Schizophrenia in Korea: A Randomized, Double-Blind, Active-Controlled Trial
Se Hyun KIM ; Do-Un JUNG ; Do Hoon KIM ; Jung Sik LEE ; Kyoung-Uk LEE ; Seunghee WON ; Bong Ju LEE ; Sung-Gon KIM ; Sungwon ROH ; Jong-Ik PARK ; Minah KIM ; Sung Won JUNG ; Hong Seok OH ; Han-yong JUNG ; Sang Hoon KIM ; Hyun Seung CHEE ; Jong-Woo PAIK ; Kyu Young LEE ; Soo In KIM ; Seung-Hwan LEE ; Eun-Jin CHEON ; Hye-Geum KIM ; Heon-Jeong LEE ; In Won CHUNG ; Joonho CHOI ; Min-Hyuk KIM ; Seong-Jin CHO ; HyunChul YOUN ; Jhin-Goo CHANG ; Hoo Rim SONG ; Euitae KIM ; Won-Hyoung KIM ; Chul Eung KIM ; Doo-Heum PARK ; Byung-Ook LEE ; Jungsun LEE ; Seung-Yup LEE ; Nuree KANG ; Hee Yeon JUNG
Psychiatry Investigation 2024;21(7):762-771
Objective:
This study was performed to evaluate the efficacy and safety of lurasidone (160 mg/day) compared to quetiapine XR (QXR; 600 mg/day) in the treatment of acutely psychotic patients with schizophrenia.
Methods:
Patients were randomly assigned to 6 weeks of double-blind treatment with lurasidone 160 mg/day (n=105) or QXR 600 mg/day (n=105). Primary efficacy measure was the change from baseline to week 6 in Positive and Negative Syndrome Scale (PANSS) total score and Clinical Global Impressions severity (CGI-S) score. Adverse events, body measurements, and laboratory parameters were assessed.
Results:
Lurasidone demonstrated non-inferiority to QXR on the PANSS total score. Adjusted mean±standard error change at week 6 on the PANSS total score was -26.42±2.02 and -27.33±2.01 in the lurasidone and QXR group, respectively. The mean difference score was -0.91 (95% confidence interval -6.35–4.53). The lurasidone group showed a greater reduction in PANSS total and negative subscale on week 1 and a greater reduction in end-point CGI-S score compared to the QXR group. Body weight, body mass index, and waist circumference in the lurasidone group were reduced, with significantly lower mean change compared to QXR. Endpoint changes in glucose, cholesterol, triglycerides, and low-density lipoprotein levels were also significantly lower. The most common adverse drug reactions with lurasidone were akathisia and nausea.
Conclusion
Lurasidone 160 mg/day was found to be non-inferior to QXR 600 mg/day in the treatment of schizophrenia with comparable efficacy and tolerability. Adverse effects of lurasidone were generally tolerable, and beneficial effects on metabolic parameters can be expected.

Result Analysis
Print
Save
E-mail