1.Medication-related osteonecrosis of the jaw: an evidence-based 2025position statement from a Korean multidisciplinary task force
Jin-Woo KIM ; Sung-Hye KONG ; Jae-Young KIM ; Mi Kyung KWAK ; Jun-Young KIM ; Ji-Hyeon OH ; Hyung-Youl PARK ; BeomTaek KIM ; Young-Kyun LEE ; Jeong Joon HAN ; Moon-Young KIM ; Yong Jun CHOI ; Yong-Dae KWON ; Kwang-Sup SONG ; Beom-Jun KIM ; Sun-Jong KIM ; Seung-Hoon BAEK ; Dong Ock LEE ; Han Seok CHOI ; Ha Young KIM ; Tae-Geon KWON ;
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(6):333-353
With a rapidly aging population and increasing use of antiresorptive agents, medication-related osteonecrosis of the jaw (MRONJ) represents a growing clinical challenge worldwide. To address the need for tailored clinical guidance, a multidisciplinary task force was convened. Five Korean academic societies—the Korean Society for Bone and Mineral Research, the Korean Association of Oral and Maxillofacial Surgeons, the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons, the Korean Society of Osteoporosis, and the Korean Endocrine Society—collaborated to develop this position statement. The consensus was formulated through comprehensive reviews of literature, combined with three rounds of formal surveys to consolidate expert opinion on controversial topics. This position paper provides evidence-based clinical guidelines for the prevention, diagnosis, and management of MRONJ tailored to the Korean healthcare environment. The diagnostic criteria affirm the standard definition but add a provision for diagnosis based on clinical or radiographic evidence of necrotic bone, even if the traditional 8-week timeframe has not been met. The committee advocates for retaining Stage 0 in the staging system to emphasize early detection and preventive intervention. Key recommendations include prescriptive, drug-specific guidelines for prophylactic drug holidays (e.g., a 2-month pause for oral bisphosphonates; timing surgery 3-4 months after the last denosumab injection) to minimize MRONJ risk from dental procedures. This statement also provides a clear framework for therapeutic drug holidays in established MRONJ, carefully balancing the need for jaw healing against systemic fracture risk. For treatment, this statement advocates for early and active surgical intervention across all MRONJ stages, supported by evidence of superior long-term outcomes compared to conservative management.This position statement offers a unique, evidence-based Korean clinical practice guideline for managing MRONJ. It is intended to standardize care, reduce clinical confusion, and ultimately improve patient outcomes by providing a clear framework for decision-making.
2.Medication-Related Osteonecrosis of the Jaw: An Evidence-Based 2025 Position Statement from a Korean Multidisciplinary Task Force
Jin-Woo KIM ; Sung-Hye KONG ; Jae-Young KIM ; Mi Kyung KWAK ; Jun-Young KIM ; Ji-Hyeon OH ; Hyung-Youl PARK ; BeomTaek KIM ; Young-Kyun LEE ; Jeong Joon HAN ; Moon-Young KIM ; Yong Jun CHOI ; Yong-Dae KWON ; Kwang-Sup SONG ; Beom-Jun KIM ; Sun-Jong KIM ; Seung-Hoon BAEK ; Dong Ock LEE ; Han Seok CHOI ; Ha Young KIM ; Tae-Geon KWON
Endocrinology and Metabolism 2025;40(6):787-810
With a rapidly aging population and increasing use of antiresorptive agents, medication-related osteonecrosis of the jaw (MRONJ) represents a growing clinical challenge worldwide. To address the need for tailored clinical guidance, a multidisciplinary task force was convened. Five Korean academic societies—the Korean Society for Bone and Mineral Research, the Korean Association of Oral and Maxillofacial Surgeons, the Korean Society of Maxillofacial Plastic and Reconstructive Surgeons, the Korean Osteoporosis Society, and the Korean Endocrine Society—collaborated to develop this position statement. The consensus was formulated through comprehensive reviews of literature, combined with three rounds of formal surveys to consolidate expert opinion on controversial topics. This position paper provides evidence-based clinical guidelines for the prevention, diagnosis, and management of MRONJ tailored to the Korean healthcare environment. The diagnostic criteria affirm the standard definition but add a provision for diagnosis based on clinical or radiographic evidence of necrotic bone, even if the traditional 8-week timeframe has not been met. The committee advocates for retaining stage 0 in the staging system to emphasize early detection and preventive intervention. Key recommendations include prescriptive, drug-specific guidelines for prophylactic drug holidays (e.g., a 2-month pause for oral bisphosphonates; timing surgery 3 to 4 months after the last denosumab injection) to minimize MRONJ risk from dental procedures. This statement also provides a clear framework for therapeutic drug holidays in established MRONJ, carefully balancing the need for jaw healing against systemic fracture risk. For treatment, this statement advocates for early and active surgical intervention across all MRONJ stages, supported by evidence of superior long-term outcomes compared to conservative management. This position statement offers a unique, evidence-based Korean clinical practice guideline for managing MRONJ. It is intended to standardize care, reduce clinical confusion, and ultimately improve patient outcomes by providing a clear framework for decision-making.
3.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
4.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
5.Effect of Furosemide on Prevertebral Soft Tissue Swelling after Anterior Cervical Fusion: A Comparative Study with Dexamethasone
Ju-Sung JANG ; Young-Seok LEE ; Myeong Jin KO ; Seong Hyun WUI ; Kwang-Sup SONG ; Seung Won PARK
Asian Spine Journal 2024;18(1):66-72
Methods:
The symptomatic PSTS group received intravenous (IV) administration of dexamethasone or furosemide. The asymptomatic PSTS group did not receive any medication. Patients were divided into the control (no medication, n=31), Dexa (IV dexamethasone, n=25), and Furo (IV furosemide, n=28) groups. PSTS was checked daily with simple radiographs and medication-induced reductions in PSTS from its peak or after medication.
Results:
The peak time (postoperative days) of PSTS in the control (2.27±0.47, p<0.05) and Dexa (1.91±0.54, p<0.01) groups were significantly later than that in the Furo group (1.38±0.74). PSTS was significantly lower in the Furo group than in the Dexa group from postoperative days 4 to 7 (p<0.05). PSTS reduction after the peak was significantly greater in the Furo group than in the control (p<0.01) and Dexa (p<0.01) groups. After starting the medication therapy, the Furo group showed a significantly greater reduction in PSTS than the Dexa group (p<0.01). No difference was found in symptom improvement among the three groups.
Conclusions
If furosemide is used to reduce PSTS after ACF, it can effectively reduce symptoms.
6.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
7.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
8.Safety Profile of Biportal Endoscopic Spine Surgery Compared to Conventional Microscopic Approach: A Pooled Analysis of 2 Randomized Controlled Trials
Sang-Min PARK ; Kwang-Sup SONG ; Dae-Woong HAM ; Ho-Joong KIM ; Min-Seok KANG ; Ki-Han YOU ; Choon Keun PARK ; Dong-Keun LEE ; Jin-Sung KIM ; Hong-Jae LEE ; Hyun-Jin PARK
Neurospine 2024;21(4):1190-1198
Objective:
To compare the safety profiles of biportal endoscopic spinal surgery (BESS) and microscopic spinal surgery (MSS) for lumbar disc herniation and spinal stenosis by analyzing the associated adverse events.
Methods:
We pooled data from 2 prospective randomized controlled trials involving 220 patients (110 in each group) who underwent single-level lumbar surgery. Participants aged 20–80 years with radiating pain due to lumbar disc herniation or spinal stenosis were included in this study. Adverse events were recorded and analyzed over a 12-month follow-up period.
Results:
The overall adverse event rates were 9.1% (10 of 110) in the BESS group and 17.3% (19 of 110) in the MSS group, which were not statistically significantly different (p=0.133). Notably, wound dehiscence occurred in 8.2% of MSS cases but in none of the BESS cases. Both groups showed similarly low rates of complications, such as dural tears, epidural hematoma, and nerve root injury. The most common adverse event in the BESS group was recurrent disc herniation (2.7%), whereas that in the MSS group was wound dehiscence (8.2%).
Conclusion
BESS demonstrated a safety profile comparable to that of MSS for the treatment of lumbar disc herniation and spinal stenosis, with a trend towards fewer overall complications. BESS offers particular advantages in terms of reducing wound-related complications. These findings suggest that BESS is a safe alternative to conventional MSS and potentially offers the benefits of a minimally invasive approach without compromising patient safety.
9.Postoperative Segmental Motion up to 1 Year Following Single-Level Anterior Cervical Discectomy and Fusion: Plate versus Non-plate
Kwang-Sup SONG ; Jeongik LEE ; Dae Woong HAM ; Chan-Woo JUNG ; Hyun KANG ; Seung Won PARK ; Dong-Gune CHANG ; Youngbae B. KIM
Asian Spine Journal 2023;17(3):492-499
Methods:
In retrospectively collected data, 149 patients who underwent single-level ACDF for degenerative disease were enrolled and divided into non-plating (n=66) and plating (n=83). Interspinous motion (ISM) at the arthrodesis segment, Numeric Rating Scale (NRS) for neck pain, and Neck Disability Index (NDI) were serially evaluated at 3, 6, and 12 months postoperatively. Predictable factors for fusion, including age, sex, plating, diabetes, smoking, and type of grafts, were investigated, and fusion was defined as ISM <1 mm.
Results:
In both groups, ISM was the highest at 3 months and gradually decreased thereafter, and the plating group showed significantly lower serial ISM than the non-plating group at 12 months. The plating group had lower NRS and NDI scores than the nonplating group at 12 months, and the difference in the NRS scores was statistically significant, particularly at 3 and 6 months, although that of the NDI scores was not. In a multivariate analysis, plating was the most powerful predictor for fusion.
Conclusions
Plating significantly decreases the serial ISM compared with non-plating in single-level ACDF, and such decreased motion is correlated with decreased neck pain until 12 months postoperatively, particularly at 3 and 6 months. Given that plating was the most predictive factor for fusion, we recommend plating even in single-level ACDF for better early clinical outcomes.
10.Feasibility of Non-window Three-Dimensional– Printed Porous Titanium Cage in Posterior Lumbar Interbody Fusion: A Pilot Trial
Dae-Woong HAM ; Chan-Woo JUNG ; Dong-Gune CHANG ; Jae Jun YANG ; Kwang-Sup SONG
Clinics in Orthopedic Surgery 2023;15(6):960-967
Background:
The commercially available design of a three-dimensional (3D)–printed titanium (3D-Ti) cage can be divided into two types according to the presence of a window: a cage with a window that allows filling of bone graft materials and a non-window cage for stand-alone use. This prospective observational case series study aimed to explore the clinical feasibility of using a nonwindow type 3D-Ti cage in cases of combined window and non-window cage implantation. Furthermore, we evaluated the bone in growth patterns of non-window cages and their correlation with published fusion grading systems.
Methods:
A total of 31 consecutive patients who underwent single-level posterior lumbar interbody fusion surgery were included. Two 3D-Ti cages with different designs were inserted: a non-window cage on the left side and a window cage on the right side.Radiographic fusion was defined by the segmental angle between flexion and extension radiographs (F-E angle) and cage bridging bone (CBB) scores on computed tomography. The association between the F-E angle and osteointegration scoring system including the surface osteointegration ratio (SOR) score was analyzed.
Results:
Radiographic fusion was achieved in 27 of 31 patients (87%) at 12 months postoperatively. Among the non-window cages, 23 of 31 (74.2%) had fair SOR scores, while 19 of 31 (61.3%) window cages had fair intra-cage CBB scores. The higher the SOR score was, the smaller the flexion-extension angle (SOR 0 vs. SOR 1: 6.30° ± 2.43° vs. 1.95° ± 0.99°, p < 0.001; SOR 0 vs. SOR 2: 6.03° ± 2.43° vs. 0.99°± 0.74°, p < 0.001).
Conclusions
The clinical feasibility of using a non-window 3D-Ti cage during lumbar interbody fusion might be acceptable. Furthermore, a newly suggested fusion criterion for the use of the non-window cage, the SOR score, showed a significant association with the published fusion grading systems, demonstrating its feasibility in determining interbody fusion in lumbar spinal surgery.

Result Analysis
Print
Save
E-mail