1.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
2.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
3.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
4.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
5.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
6.Colon cancer: the 2023 Korean clinical practice guidelines for diagnosis and treatment
Hyo Seon RYU ; Hyun Jung KIM ; Woong Bae JI ; Byung Chang KIM ; Ji Hun KIM ; Sung Kyung MOON ; Sung Il KANG ; Han Deok KWAK ; Eun Sun KIM ; Chang Hyun KIM ; Tae Hyung KIM ; Gyoung Tae NOH ; Byung-Soo PARK ; Hyeung-Min PARK ; Jeong Mo BAE ; Jung Hoon BAE ; Ni Eun SEO ; Chang Hoon SONG ; Mi Sun AHN ; Jae Seon EO ; Young Chul YOON ; Joon-Kee YOON ; Kyung Ha LEE ; Kyung Hee LEE ; Kil-Yong LEE ; Myung Su LEE ; Sung Hak LEE ; Jong Min LEE ; Ji Eun LEE ; Han Hee LEE ; Myong Hoon IHN ; Je-Ho JANG ; Sun Kyung JEON ; Kum Ju CHAE ; Jin-Ho CHOI ; Dae Hee PYO ; Gi Won HA ; Kyung Su HAN ; Young Ki HONG ; Chang Won HONG ; Jung-Myun KWAK ;
Annals of Coloproctology 2024;40(2):89-113
Colorectal cancer is the third most common cancer in Korea and the third leading cause of death from cancer. Treatment outcomes for colon cancer are steadily improving due to national health screening programs with advances in diagnostic methods, surgical techniques, and therapeutic agents.. The Korea Colon Cancer Multidisciplinary (KCCM) Committee intends to provide professionals who treat colon cancer with the most up-to-date, evidence-based practice guidelines to improve outcomes and help them make decisions that reflect their patients’ values and preferences. These guidelines have been established by consensus reached by the KCCM Guideline Committee based on a systematic literature review and evidence synthesis and by considering the national health insurance system in real clinical practice settings. Each recommendation is presented with a recommendation strength and level of evidence based on the consensus of the committee.
7.Modulation of Vascular Smooth Muscle Cell Phenotype by High Mobility Group AT-Hook 1
Yoojin JUNG ; Hae Sun LEE ; Jung Min HA ; Seo Yeon JIN ; Hye Jin KUM ; Farzaneh VAFAEINIK ; Hong Koo HA ; Sang Heon SONG ; Chi Dae KIM ; Sun Sik BAE
Journal of Lipid and Atherosclerosis 2021;10(1):99-110
Objective:
The purpose of this study is to examine the effect of high mobility group AT-hook 1 (HMGA1) on the phenotyptic change of vascular smooth muscle cells (VSMCs).
Methods:
Gene silencing and overexpression of HMGA1 were introduced to evaluate the effect of HMGA1 expression on the phenotypic change of VSMCs. Marker gene expression of VSMCs was measured by promoter assay, quantitative polymerase chain reaction, and western blot analysis. Common left carotid artery ligation model was used to establish in vivo neointima formation.
Results:
HMGA1 was expressed strongly in the synthetic type of VSMCs and significantly downregulated during the differentiation of VSMCs. Silencing of HMGA1 in the synthetic type of VSMCs enhanced the expression of contractile marker genes thereby enhanced angiotensin II (Ang II)-dependent contraction, however, significantly suppressed proliferation and migration. Stimulation of contractile VSMCs with platelet-derived growth factor (PDGF) enhanced HMGA1 expression concomitant with the downregulation of marker gene expression which was blocked significantly by the silencing of HMGA1. Silencing of HMGA1 retained the Ang II-dependent contractile function, which was curtailed by PDGF stimulation, however, overexpression of HMGA1 in the contractile type of VSMCs suppressed marker gene expression. Proliferation and migration were enhanced significantly by the overexpression of HMGA1. Furthermore, the Ang II-dependent contraction was reduced significantly by the overexpression of HMGA1. Finally, the expression of HMGA1 was enhanced significantly in the ligated artery, especially in the neointima area.
Conclusion
HMGA1 plays an essential role in the phenotypic modulation of VSMCs.Therefore, paracrine factors such as PDGF may affect vascular remodeling through the regulation of HMGA1.
8.Low Hepatic Toxicity in Primary and Metastatic Liver Cancers after Stereotactic Ablative Radiotherapy Using 3 Fractions.
Sun Hyun BAE ; Mi Sook KIM ; Won Il JANG ; Chul Koo CHO ; Hyung Jun YOO ; Kum Bae KIM ; Chul Ju HAN ; Su Cheol PARK ; Dong Han LEE
Journal of Korean Medical Science 2015;30(8):1055-1061
This study evaluated the incidence of hepatic toxicity after stereotactic ablative radiotherapy (SABR) using 3 fractions to the liver, and identified the predictors for hepatic toxicity. We retrospectively reviewed 78 patients with primary and metastatic liver cancers, who underwent SABR using 3 fractions between 2003 and 2011. To examine the incidence of hepatic toxicity, we defined newly developed hepatic toxicity> or =grade 2 according to the National Cancer Institute Common Terminology Criteria for Adverse Events v4.0 within 3 months after the end of SABR as a significant adverse event. To identify the predictors for hepatic toxicity, we analyzed several clinical and dosimetric parameters (rV(5Gy)-rV(35Gy): normal liver volume receiving
Aged
;
*Dose Fractionation
;
Female
;
Hepatitis/*etiology/pathology/prevention & control
;
Humans
;
Liver Neoplasms/complications/pathology/*surgery
;
Male
;
Middle Aged
;
Neoplasm Metastasis
;
Radiation Injuries/*etiology/pathology/prevention & control
;
Radiosurgery/*adverse effects/*methods
;
Radiotherapy Dosage
;
Treatment Outcome
9.Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma.
Eun Kyung PAIK ; Mi Sook KIM ; Chul Won CHOI ; Won Il JANG ; Sung Hyun LEE ; Sang Hyoun CHOI ; Kum Bae KIM ; Dong Han LEE
Radiation Oncology Journal 2015;33(3):233-241
PURPOSE: To compare volumetric modulated arc therapy of RapidArc with robotic stereotactic body radiation therapy (SBRT) of CyberKnife in the planning and delivery of SBRT for hepatocellular carcinoma (HCC) treatment by analyzing dosimetric parameters. MATERIALS AND METHODS: Two radiation treatment plans were generated for 29 HCC patients, one using Eclipse for the RapidArc plan and the other using Multiplan for the CyberKnife plan. The prescription dose was 60 Gy in 3 fractions. The dosimetric parameters of planning target volume (PTV) coverage and normal tissue sparing in the RapidArc and the CyberKnife plans were analyzed. RESULTS: The conformity index was 1.05 +/- 0.02 for the CyberKnife plan, and 1.13 +/- 0.10 for the RapidArc plan. The homogeneity index was 1.23 +/- 0.01 for the CyberKnife plan, and 1.10 +/- 0.03 for the RapidArc plan. For the normal liver, there were significant differences between the two plans in the low-dose regions of V1 and V3. The normalized volumes of V60 for the normal liver in the RapidArc plan were drastically increased when the mean dose of the PTVs in RapidArc plan is equivalent to the mean dose of the PTVs in the CyberKnife plan. CONCLUSION: CyberKnife plans show greater dose conformity, especially in small-sized tumors, while RapidArc plans show good dosimetric distribution of low dose sparing in the normal liver and body.
Carcinoma, Hepatocellular*
;
Humans
;
Liver
;
Prescriptions
;
Radiosurgery
;
Radiotherapy, Intensity-Modulated*
10.Outcomes of stereotactic body radiotherapy for unresectable primary or recurrent cholangiocarcinoma.
Da Hoon JUNG ; Mi Sook KIM ; Chul Koo CHO ; Hyung Jun YOO ; Won Il JANG ; Young Seok SEO ; Eun Kyung PAIK ; Kum Bae KIM ; Chul Ju HAN ; Sang Bum KIM
Radiation Oncology Journal 2014;32(3):163-169
PURPOSE: To report the results of stereotactic body radiotherapy (SBRT) for unresectable primary or recurrent cholangiocarcinoma. MATERIALS AND METHODS: From January 2005 through August 2013, 58 patients with unresectable primary (n = 28) or recurrent (n = 30) cholangiocarcinoma treated by SBRT were retrospectively analyzed. The median prescribed dose was 45 Gy in 3 fractions (range, 15 to 60 Gy in 1-5 fractions). Patients were treated by SBRT only (n = 53) or EBRT + SBRT boost (n = 5). The median tumor volume was 40 mL (range, 5 to 1,287 mL). RESULTS: The median follow-up duration was 10 months (range, 1 to 97 months). The 1-year, 2-year overall survival rates, and median survival were 45%, 20%, and 10 months, respectively. The median survival for primary group and recurrent group were 5 and 13 months, respectively. Local control rate at 1-year and 2-year were 85% and 72%, respectively. Disease progression-free survival rates at 1-year and 2-year were 26% and 23%, respectively. In univariate analysis, ECOG performance score (0-1 vs. 2-3), treatment volume (<50 vs. > or =50 mL), and pre-SBRT CEA level (<5 vs. > or =5 ng/mL) were significant in overall survival rate. In multivariate analysis, ECOG score (p = 0.037) and tumor volume (p = 0.030) were statistically significant. In the recurrent tumor group, patients with >12 months interval from surgery to recurrence showed statistically significant higher overall survival rate than those with < or =12 months (p = 0.026). Six patients (10%) experienced > or =grade 3 complications. CONCLUSION: SBRT can be considered as an effective local modality for unresectable primary or recurrent cholangiocarcinoma.
Cholangiocarcinoma*
;
Disease-Free Survival
;
Follow-Up Studies
;
Humans
;
Multivariate Analysis
;
Radiosurgery*
;
Recurrence
;
Retrospective Studies
;
Survival Rate
;
Tumor Burden

Result Analysis
Print
Save
E-mail