1.A Practical Immunohistochemistry-Based Model for Predicting Pathologic Complete Response in Estrogen Receptor-Strong Positive and HER2-Negative Breast Cancer
Su Min LEE ; Jeong Eon LEE ; Seok Jin NAM ; Seok Won KIM ; Jonghan YU ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Eun Yoon CHO ; Hyunwoo LEE ; Woong Ki PARK
Journal of Breast Cancer 2026;29(2):128-140
Purpose:
While the benefit of neoadjuvant chemotherapy (NAC) has been established in human epidermal growth factor receptor 2 (HER2)-positive and triple-negative breast cancers, its effectiveness in achieving pathological complete response (pCR) and optimal patient selection in estrogen receptor (ER)-positive, HER2-negative breast cancers remain less clearly defined. This study aimed to identify immunohistochemistry (IHC)-based predictors of pCR and to develop a scoring model for ER-strong positive/HER2-negative breast cancer.
Methods:
Data from a prospective cohort were retrospectively analyzed. We included 522 patients with ER-strong positive/HER2-negative tumors who received NAC and surgery between 2008 and 2021. IHC markers including progesterone receptor (PR), Ki-67, epidermal growth factor receptor (EGFR), cytokeratin 5/6 (CK5/6), and p53 were evaluated to identify predictors of pCR. Independent predictors of pCR from multivariate logistic regression were used to develop a weighted 4-point model. Model performance was assessed using receiver operating characteristic analysis. The prognostic impact of pCR was evaluated using KaplanMeier and Cox regression analyses.
Results:
Independent predictors of pCR included PR-negative status, positivity for basallike markers (EGFR or CK5/6), and Ki-67 ≥ 50%. The scoring model demonstrated good discrimination for pCR (area under the curve = 0.754). pCR rates increased stepwise, with scores of 4.9% (low), 10.7% (intermediate), and 36.2% (high). In the high-score group, pCR was significantly associated with improved disease-free survival (hazard ratio [HR], 0.09; p = 0.023) and distant metastasis-free survival (HR, 0.11; p = 0.035), whereas no significant survival differences according to pCR status were observed in the low and intermediate score groups.
Conclusion
This IHC-based model predicts pCR and helps identify subgroups in which pCR is associated with meaningful survival benefit following NAC in ER-positive/HER2-negative breast cancers. High-scoring patients may benefit from NAC, while patients with low- or intermediatescores may be better managed with surgery and endocrine therapy. This model may support personalized treatment decisions regarding NAC.
2.Clinical Outcomes of Lobular Carcinoma In Situ: Risk of Invasive Cancer Development
Doyoun WOEN ; Ki Jo KIM ; Su Min LEE ; Seungah LEE ; Kawon OH ; Cho Eun LEE ; Seok Jin NAM ; Seok Won KIM ; Jeong Eon LEE ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Woong Ki PARK ; Hyunwoo LEE ; Jonghan YU
Journal of Breast Cancer 2026;29(2):163-174
Purpose:
Lobular carcinoma In Situ (LCIS) is a noninvasive lesion associated with an increased risk of invasive cancer. Since its removal from the tumor, node, metastasis classification in the 8th edition of the American Joint Committee on Cancer (AJCC) guidelines, the clinical management of LCIS has shifted from surgery to surveillance. However, studies focusing on the risk and associated factors for invasive cancer development in pure LCIS without ductal carcinoma In Situ (DCIS) or invasive cancer remain limited.
Methods:
We retrospectively analyzed 106 patients diagnosed with pure LCIS between 2008 and 2018. This study evaluated the effect of tamoxifen use and histologic type on the development of invasive cancer.
Results:
All 106 patients underwent surgery, and nine (8.5%) developed invasive cancer over a median follow-up of 67.5 months. The incidence of invasive cancer was lower in the tamoxifen group (6.3%, n = 4) than in the non-tamoxifen group (11.9%, n = 5), although this difference was not statistically significant (p = 0.266). Pleomorphic LCIS had a significantly higher incidence of invasive cancer (30.0%, n = 3) than classic LCIS (6.3%, n = 6) (p = 0.045).Multivariable Cox regression analysis showed no significant difference in the risk of invasive cancer according to tamoxifen use (hazard ratio [HR], 2.031; 95% confidence interval [CI], 0.544–7.579; p = 0.292). However, pleomorphic LCIS showed a trend toward an increased risk of invasive cancer compared to classic LCIS (HR, 3.856; 95% CI, 0.922–16.126; p = 0.064).
Conclusion
Postoperative tamoxifen did not significantly lower invasive cancer development in patients with pure LCIS. Pleomorphic LCIS may carry a higher risk than classic LCIS. These findings require tailored follow-up and treatment strategies based on the histologic subtype of LCIS.
3.Mock communities to assess biases in nextgeneration sequencing of bacterial species representation
Younjee HWANG ; Ju Yeong KIM ; Se Il KIM ; Ji Yeon SUNG ; Hye Su MOON ; Tai-Soon YONG ; Ki Ho HONG ; Hyukmin LEE ; Dongeun YONG
Annals of Clinical Microbiology 2025;28(1):3-
Background:
The 16S rRNA-targeted next-generation sequencing (NGS) has been widely used as the primary tool for microbiome analysis. However, whether the sequenced microbial diversity absolutely represents the original sample composition remains unclear. This study aimed to evaluate whether 16S rRNA gene-targeted NGS accurately captures bacterial community composition.
Methods:
Mock communities were constructed using equal amounts of DNA from 18 bacterial strains in three formats: genomic DNA, recombinant plasmids, and polymerase chain reaction (PCR) templates. The V3V4 region of the 16S rRNA gene was amplified and sequenced using the Illumina MiSeq.
Results:
Data regression analysis revealed that the recombinant plasmid produced more accurate and precise correlation curve than that by the gDNA and PCR products, with a slope closest to 1 (1.0082) and the highest R² value (0.9975). Despite the same input amount of bacterial DNA, the NGS read distribution varied across all three mock communities. Using multiple regression analysis, we found that the guanine-cytosine (GC) content of the V3V4 region, 16S rRNA gene, size of gDNA, and copy number of 16S rRNA were significantly associated with the NGS output of each bacterial species.
Conclusion
This study demonstrated that recombinant plasmids are the preferred option for quality control and that NGS output is biased owing to certain bacterial characteristics, such as %GC content, gDNA size, and 16S rRNA gene copy number. Further research is required to develop a system that compensates for NGS process biases using mock communities.
4.Mock communities to assess biases in nextgeneration sequencing of bacterial species representation
Younjee HWANG ; Ju Yeong KIM ; Se Il KIM ; Ji Yeon SUNG ; Hye Su MOON ; Tai-Soon YONG ; Ki Ho HONG ; Hyukmin LEE ; Dongeun YONG
Annals of Clinical Microbiology 2025;28(1):3-
Background:
The 16S rRNA-targeted next-generation sequencing (NGS) has been widely used as the primary tool for microbiome analysis. However, whether the sequenced microbial diversity absolutely represents the original sample composition remains unclear. This study aimed to evaluate whether 16S rRNA gene-targeted NGS accurately captures bacterial community composition.
Methods:
Mock communities were constructed using equal amounts of DNA from 18 bacterial strains in three formats: genomic DNA, recombinant plasmids, and polymerase chain reaction (PCR) templates. The V3V4 region of the 16S rRNA gene was amplified and sequenced using the Illumina MiSeq.
Results:
Data regression analysis revealed that the recombinant plasmid produced more accurate and precise correlation curve than that by the gDNA and PCR products, with a slope closest to 1 (1.0082) and the highest R² value (0.9975). Despite the same input amount of bacterial DNA, the NGS read distribution varied across all three mock communities. Using multiple regression analysis, we found that the guanine-cytosine (GC) content of the V3V4 region, 16S rRNA gene, size of gDNA, and copy number of 16S rRNA were significantly associated with the NGS output of each bacterial species.
Conclusion
This study demonstrated that recombinant plasmids are the preferred option for quality control and that NGS output is biased owing to certain bacterial characteristics, such as %GC content, gDNA size, and 16S rRNA gene copy number. Further research is required to develop a system that compensates for NGS process biases using mock communities.
5.The Incidence of Occult Malignancy in Contralateral Risk Reducing Mastectomy Among Affected Breast Cancer Gene Mutation Carriers in South Korea
Cho Eun LEE ; Dong Seung SHIN ; Ki Jo KIM ; Seok Jin NAM ; Seok Won KIM ; Jonghan YU ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Goo-Hyun MUN ; Jai-Kyong PYON ; Byung-Joon JEON ; Kyongje WOO ; Jeong Eon LEE
Journal of Breast Cancer 2025;28(1):1-10
Purpose:
Breast cancer gene (BRCA) mutation is a well-known risk factor for breast cancer, and clinical interest in prophylactic mastectomy has increased in recent years.We investigated patients who were BRCA mutation carriers and underwent contralateral risk-reducing mastectomy (RRM), focusing on the incidence of occult malignancy after contralateral RRM.
Methods:
Prospectively collected data of patients with breast cancer treated at a single institution were retrospectively reviewed. Patients who underwent RRM with BRCA mutation who underwent RRM between January 2010 and November 2023 were included in this study.Among patients who underwent contralateral RRM, those with a primary cancer diagnosis were included, and those with occult malignancy on the contralateral RRM side were reviewed additionally. The demographics and pathologies of both primary breast cancer and occult malignancies were evaluated.
Results:
In our institution, 925 patients were identified as BRCA mutation carriers, and 320 patients underwent contralateral RRM along with primary breast cancer surgery. BRCA2 mutation occurred more frequently (54.8%) in the overall BRCA mutation cohort. Furthermore, we reviewed 320 patients diagnosed with breast cancer and detected as BRCA mutation carriers who underwent contralateral RRM; high proportion of them were BRCA1 mutation carriers.Interestingly, we found a low incidence of only seven patients (2.2%) with occult malignancy on contralateral RRM side, which is different from that reported in other nations.
Conclusion
The incidence of occult malignancy in the contralateral breast of breast cancer patients with breast cancer with BRCA mutation is significantly low, and may be influenced by several factors. Increased utilization of screening and advancements in diagnostic technologies in South Korea have reduced the chance of occult malignancy in RRM, and a variety of pathologic examination methods may affect the rate of incidence.
6.Mock communities to assess biases in nextgeneration sequencing of bacterial species representation
Younjee HWANG ; Ju Yeong KIM ; Se Il KIM ; Ji Yeon SUNG ; Hye Su MOON ; Tai-Soon YONG ; Ki Ho HONG ; Hyukmin LEE ; Dongeun YONG
Annals of Clinical Microbiology 2025;28(1):3-
Background:
The 16S rRNA-targeted next-generation sequencing (NGS) has been widely used as the primary tool for microbiome analysis. However, whether the sequenced microbial diversity absolutely represents the original sample composition remains unclear. This study aimed to evaluate whether 16S rRNA gene-targeted NGS accurately captures bacterial community composition.
Methods:
Mock communities were constructed using equal amounts of DNA from 18 bacterial strains in three formats: genomic DNA, recombinant plasmids, and polymerase chain reaction (PCR) templates. The V3V4 region of the 16S rRNA gene was amplified and sequenced using the Illumina MiSeq.
Results:
Data regression analysis revealed that the recombinant plasmid produced more accurate and precise correlation curve than that by the gDNA and PCR products, with a slope closest to 1 (1.0082) and the highest R² value (0.9975). Despite the same input amount of bacterial DNA, the NGS read distribution varied across all three mock communities. Using multiple regression analysis, we found that the guanine-cytosine (GC) content of the V3V4 region, 16S rRNA gene, size of gDNA, and copy number of 16S rRNA were significantly associated with the NGS output of each bacterial species.
Conclusion
This study demonstrated that recombinant plasmids are the preferred option for quality control and that NGS output is biased owing to certain bacterial characteristics, such as %GC content, gDNA size, and 16S rRNA gene copy number. Further research is required to develop a system that compensates for NGS process biases using mock communities.
7.Mock communities to assess biases in nextgeneration sequencing of bacterial species representation
Younjee HWANG ; Ju Yeong KIM ; Se Il KIM ; Ji Yeon SUNG ; Hye Su MOON ; Tai-Soon YONG ; Ki Ho HONG ; Hyukmin LEE ; Dongeun YONG
Annals of Clinical Microbiology 2025;28(1):3-
Background:
The 16S rRNA-targeted next-generation sequencing (NGS) has been widely used as the primary tool for microbiome analysis. However, whether the sequenced microbial diversity absolutely represents the original sample composition remains unclear. This study aimed to evaluate whether 16S rRNA gene-targeted NGS accurately captures bacterial community composition.
Methods:
Mock communities were constructed using equal amounts of DNA from 18 bacterial strains in three formats: genomic DNA, recombinant plasmids, and polymerase chain reaction (PCR) templates. The V3V4 region of the 16S rRNA gene was amplified and sequenced using the Illumina MiSeq.
Results:
Data regression analysis revealed that the recombinant plasmid produced more accurate and precise correlation curve than that by the gDNA and PCR products, with a slope closest to 1 (1.0082) and the highest R² value (0.9975). Despite the same input amount of bacterial DNA, the NGS read distribution varied across all three mock communities. Using multiple regression analysis, we found that the guanine-cytosine (GC) content of the V3V4 region, 16S rRNA gene, size of gDNA, and copy number of 16S rRNA were significantly associated with the NGS output of each bacterial species.
Conclusion
This study demonstrated that recombinant plasmids are the preferred option for quality control and that NGS output is biased owing to certain bacterial characteristics, such as %GC content, gDNA size, and 16S rRNA gene copy number. Further research is required to develop a system that compensates for NGS process biases using mock communities.
8.Mock communities to assess biases in nextgeneration sequencing of bacterial species representation
Younjee HWANG ; Ju Yeong KIM ; Se Il KIM ; Ji Yeon SUNG ; Hye Su MOON ; Tai-Soon YONG ; Ki Ho HONG ; Hyukmin LEE ; Dongeun YONG
Annals of Clinical Microbiology 2025;28(1):3-
Background:
The 16S rRNA-targeted next-generation sequencing (NGS) has been widely used as the primary tool for microbiome analysis. However, whether the sequenced microbial diversity absolutely represents the original sample composition remains unclear. This study aimed to evaluate whether 16S rRNA gene-targeted NGS accurately captures bacterial community composition.
Methods:
Mock communities were constructed using equal amounts of DNA from 18 bacterial strains in three formats: genomic DNA, recombinant plasmids, and polymerase chain reaction (PCR) templates. The V3V4 region of the 16S rRNA gene was amplified and sequenced using the Illumina MiSeq.
Results:
Data regression analysis revealed that the recombinant plasmid produced more accurate and precise correlation curve than that by the gDNA and PCR products, with a slope closest to 1 (1.0082) and the highest R² value (0.9975). Despite the same input amount of bacterial DNA, the NGS read distribution varied across all three mock communities. Using multiple regression analysis, we found that the guanine-cytosine (GC) content of the V3V4 region, 16S rRNA gene, size of gDNA, and copy number of 16S rRNA were significantly associated with the NGS output of each bacterial species.
Conclusion
This study demonstrated that recombinant plasmids are the preferred option for quality control and that NGS output is biased owing to certain bacterial characteristics, such as %GC content, gDNA size, and 16S rRNA gene copy number. Further research is required to develop a system that compensates for NGS process biases using mock communities.
9.The Incidence of Occult Malignancy in Contralateral Risk Reducing Mastectomy Among Affected Breast Cancer Gene Mutation Carriers in South Korea
Cho Eun LEE ; Dong Seung SHIN ; Ki Jo KIM ; Seok Jin NAM ; Seok Won KIM ; Jonghan YU ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Goo-Hyun MUN ; Jai-Kyong PYON ; Byung-Joon JEON ; Kyongje WOO ; Jeong Eon LEE
Journal of Breast Cancer 2025;28(1):1-10
Purpose:
Breast cancer gene (BRCA) mutation is a well-known risk factor for breast cancer, and clinical interest in prophylactic mastectomy has increased in recent years.We investigated patients who were BRCA mutation carriers and underwent contralateral risk-reducing mastectomy (RRM), focusing on the incidence of occult malignancy after contralateral RRM.
Methods:
Prospectively collected data of patients with breast cancer treated at a single institution were retrospectively reviewed. Patients who underwent RRM with BRCA mutation who underwent RRM between January 2010 and November 2023 were included in this study.Among patients who underwent contralateral RRM, those with a primary cancer diagnosis were included, and those with occult malignancy on the contralateral RRM side were reviewed additionally. The demographics and pathologies of both primary breast cancer and occult malignancies were evaluated.
Results:
In our institution, 925 patients were identified as BRCA mutation carriers, and 320 patients underwent contralateral RRM along with primary breast cancer surgery. BRCA2 mutation occurred more frequently (54.8%) in the overall BRCA mutation cohort. Furthermore, we reviewed 320 patients diagnosed with breast cancer and detected as BRCA mutation carriers who underwent contralateral RRM; high proportion of them were BRCA1 mutation carriers.Interestingly, we found a low incidence of only seven patients (2.2%) with occult malignancy on contralateral RRM side, which is different from that reported in other nations.
Conclusion
The incidence of occult malignancy in the contralateral breast of breast cancer patients with breast cancer with BRCA mutation is significantly low, and may be influenced by several factors. Increased utilization of screening and advancements in diagnostic technologies in South Korea have reduced the chance of occult malignancy in RRM, and a variety of pathologic examination methods may affect the rate of incidence.
10.The Incidence of Occult Malignancy in Contralateral Risk Reducing Mastectomy Among Affected Breast Cancer Gene Mutation Carriers in South Korea
Cho Eun LEE ; Dong Seung SHIN ; Ki Jo KIM ; Seok Jin NAM ; Seok Won KIM ; Jonghan YU ; Byung Joo CHAE ; Se Kyung LEE ; Jai Min RYU ; Goo-Hyun MUN ; Jai-Kyong PYON ; Byung-Joon JEON ; Kyongje WOO ; Jeong Eon LEE
Journal of Breast Cancer 2025;28(1):1-10
Purpose:
Breast cancer gene (BRCA) mutation is a well-known risk factor for breast cancer, and clinical interest in prophylactic mastectomy has increased in recent years.We investigated patients who were BRCA mutation carriers and underwent contralateral risk-reducing mastectomy (RRM), focusing on the incidence of occult malignancy after contralateral RRM.
Methods:
Prospectively collected data of patients with breast cancer treated at a single institution were retrospectively reviewed. Patients who underwent RRM with BRCA mutation who underwent RRM between January 2010 and November 2023 were included in this study.Among patients who underwent contralateral RRM, those with a primary cancer diagnosis were included, and those with occult malignancy on the contralateral RRM side were reviewed additionally. The demographics and pathologies of both primary breast cancer and occult malignancies were evaluated.
Results:
In our institution, 925 patients were identified as BRCA mutation carriers, and 320 patients underwent contralateral RRM along with primary breast cancer surgery. BRCA2 mutation occurred more frequently (54.8%) in the overall BRCA mutation cohort. Furthermore, we reviewed 320 patients diagnosed with breast cancer and detected as BRCA mutation carriers who underwent contralateral RRM; high proportion of them were BRCA1 mutation carriers.Interestingly, we found a low incidence of only seven patients (2.2%) with occult malignancy on contralateral RRM side, which is different from that reported in other nations.
Conclusion
The incidence of occult malignancy in the contralateral breast of breast cancer patients with breast cancer with BRCA mutation is significantly low, and may be influenced by several factors. Increased utilization of screening and advancements in diagnostic technologies in South Korea have reduced the chance of occult malignancy in RRM, and a variety of pathologic examination methods may affect the rate of incidence.

Result Analysis
Print
Save
E-mail