1.Prospective external validation of a deep-learning-based early-warning system for major adverse events in general wards in South Korea
Taeyong SIM ; Eun Young CHO ; Ji-hyun KIM ; Kyung Hyun LEE ; Kwang Joon KIM ; Sangchul HAHN ; Eun Yeong HA ; Eunkyeong YUN ; In-Cheol KIM ; Sun Hyo PARK ; Chi-Heum CHO ; Gyeong Im YU ; Byung Eun AHN ; Yeeun JEONG ; Joo-Yun WON ; Hochan CHO ; Ki-Byung LEE
Acute and Critical Care 2025;40(2):197-208
Background:
Acute deterioration of patients in general wards often leads to major adverse events (MAEs), including unplanned intensive care unit transfers, cardiac arrest, or death. Traditional early warning scores (EWSs) have shown limited predictive accuracy, with frequent false positives. We conducted a prospective observational external validation study of an artificial intelligence (AI)-based EWS, the VitalCare - Major Adverse Event Score (VC-MAES), at a tertiary medical center in the Republic of Korea.
Methods:
Adult patients from general wards, including internal medicine (IM) and obstetrics and gynecology (OBGYN)—the latter were rarely investigated in prior AI-based EWS studies—were included. The VC-MAES predictions were compared with National Early Warning Score (NEWS) and Modified Early Warning Score (MEWS) predictions using the area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), and logistic regression for baseline EWS values. False-positives per true positive (FPpTP) were assessed based on the power threshold.
Results:
Of 6,039 encounters, 217 (3.6%) had MAEs (IM: 9.5%, OBGYN: 0.26%). Six hours prior to MAEs, the VC-MAES achieved an AUROC of 0.918 and an AUPRC of 0.352, including the OBGYN subgroup (AUROC, 0.964; AUPRC, 0.388), outperforming the NEWS (0.797 and 0.124) and MEWS (0.722 and 0.079). The FPpTP was reduced by up to 71%. Baseline VC-MAES was strongly associated with MAEs (P<0.001).
Conclusions
The VC-MAES significantly outperformed traditional EWSs in predicting adverse events in general ward patients. The robust performance and lower FPpTP suggest that broader adoption of the VC-MAES may improve clinical efficiency and resource allocation in general wards.
2.Carrier Frequency and Incidence of MUTYH-Associated Polyposis Based on Database Analysis in East Asians and Koreans
Jong Eun PARK ; Taeheon LEE ; Eun Hye CHO ; Mi-Ae JANG ; Dongju WON ; Boyoung PARK ; Chang-Seok KI ; Sun-Young KONG
Annals of Laboratory Medicine 2025;45(1):77-84
Background:
MUTYH-associated polyposis is an autosomal recessive disorder associated with an increased lifetime risk of colorectal cancer and a moderately increased risk of ovarian, bladder, breast, and endometrial cancers. We analyzed the carrier frequency and estimated the incidence of MUTYH-associated polyposis in East Asian and Korean populations, for which limited data were previously available.
Methods:
We examined 125,748 exomes from the gnomAD database, including 9,197 East Asians, and additional data from 5,305 individuals in the Korean Variant Archive and 1,722 in the Korean Reference Genome Database. All MUTYH variants were interpreted according to the American College of Medical Genetics and Genomics and Association for Molecular Pathology guidelines and the Sequence Variant Interpretation guidelines from ClinGen.
Results:
The global carrier frequency of MUTYH-associated polyposis was 1.29%, with Europeans (non-Finnish) having the highest frequency of 1.86% and Ashkenazi Jews the lowest at 0.06%. East Asians and Koreans had a carrier frequency of 0.35% and 0.37% and an estimated incidence of 1 in 330,409 and 1 in 293,304 in Koreans, respectively, which were substantially lower than the global average of 1 in 24,160 and the European (nonFinnish) incidence of 1 in 11,520.
Conclusions
This was the first study to investigate the frequency of carriers of MUTYH-associated polyposis in East Asians, including specific subgroups, utilizing gnomAD and a Korean genome database. Our data provide valuable reference information for future investigations of MUTYH-associated polyposis to understand the genetic diversity and specific variants associated with this condition in East Asian populations.
3.Clinical Implications of Circulating Tumor DNA in Multiple Myeloma and Its Precursor Diseases
Sung-Soo PARK ; Na Yung KIM ; Ji-Young LIM ; Jung Yeon LEE ; Sujin YUN ; Yeun-Jun CHUNG ; Seung-Hyun JUNG ; Chang-Ki MIN
Annals of Laboratory Medicine 2025;45(3):279-290
Background:
Genetic alterations play a pivotal role in multiple myeloma (MM) development and therapeutic resistance. Traditionally, the genetic profiling of MM requires invasive bone marrow (BM) procedures; however, these procedures are associated with patient discomfort and cannot fully capture the spatial and temporal heterogeneity of the disease.Therefore, we investigated the clinical implications of liquid biopsy using targeted deep sequencing.
Methods:
We analyzed the genetic profiles of circulating tumor DNA (ctDNA) by targeted deep sequencing from 102 patients, including those with monoclonal gammopathy of undetermined significance (MGUS, N = 7), smoldering MM (N = 6), and symptomatic MM (N = 89).
Results:
The number of ctDNA mutations increased with disease progression from MGUS to MM, with averages of 1.0 mutations in MGUS, 1.8 mutations in smoldering MM, and 1.9 mutations in MM, respectively. Shared mutations between BM and ctDNA were more prevalent in MM (68.9%) than in MGUS (25.0%). RAS/RAF and TP53 mutations were significantly enriched in MM ctDNA. Specific mutations were associated with clinical features in patients with MM: hypercalcemia and TET2 (P = 0.006), renal insufficiency and NRAS (P = 0.012), paramedullary myeloma and TP53(P = 0.02), and extramedullary myeloma and NRAS (P = 0.007). TET2 mutations significantly affected 2-yr progression-free survival (hazard ratio = 7.11, P = 0.003). Serial ctDNA profiling accurately predicted treatment response in patients with MM.
Conclusions
Our findings highlight the potential of liquid biopsy for understanding MM progression and prognosis utilizing a minimally invasive approach, paving the way for its integration into personalized treatment strategies and real-time disease monitoring.
4.Prospective Comparative Evaluation of the Xpert MTB/RIF and Xpert MTB/RIF Ultra Assays for Detecting Mycobacterium tuberculosis and Rifampin Resistance in High-resource, Intermediate-burden Settings
Eunsang SUH ; Sangsoo JUNG ; Jun-Ki LEE ; Byung Woo JHUN ; Tae Yeul KIM ; Hee Jae HUH ; Nam Yong LEE
Annals of Laboratory Medicine 2025;45(6):583-590
Background:
The Xpert MTB/RIF Ultra (Xpert Ultra) was introduced to enhance the sensitivity of tuberculosis detection, particularly in smear-negative cases, compared with its predecessor, Xpert MTB/RIF (Xpert). However, its performance in high-resource, intermediateburden settings remains unassessed. We prospectively compared the diagnostic accuracy of Xpert Ultra and Xpert for detecting Mycobacterium tuberculosis (MTB) and rifampin resistance in Korea.
Methods:
In total, 309 respiratory specimens were analyzed using both assays. We used two reference standards: mycobacterial culture and a composite reference standard based on clinical diagnosis and treatment decisions. Diagnostic performance, including sensitivity, specificity, and agreement between the two assays, was assessed. Spiking experiments using 13 MTB isolates with known rpoB mutations were performed to evaluate rifampin resistance detection.
Results:
Xpert Ultra showed increased, albeit not significantly, sensitivity (73.7% vs. 65.8% with culture; 63.8% vs. 53.2% with the composite reference standard) over Xpert. Its specificity was comparable to that of Xpert; however, a few false-positive results were observed among trace- and very low-positives. Among six culture-negative but Xpert Ultra-positive cases, two were clinically diagnosed as tuberculosis. Of the 13 rpoB mutant strains, Xpert correctly detected all mutations in the rifampin resistance-determining region, whereas Xpert Ultra yielded indeterminate results for Q432P and Q429H/L430P/H445Q.
Conclusions
Xpert Ultra tends to have increased sensitivity; however, it shows potential diagnostic ambiguity associated with trace- or very low-positive results. These findings highlight the importance of clinical correlation, particularly in culture-negative cases. Indeterminate results in certain rpoB mutations require cautious interpretation.
5.In Vitro Diagnostics Certification for Creatinine Assays in Korea over 7 Years: Achievements and Future Outlook
Eun-Jung CHO ; Joonsang YU ; Jeayeon RYU ; Jiwoo SEO ; Hyunae LEE ; Chan-Ik CHO ; Tae-Dong JEONG ; Sollip KIM ; Woochang LEE ; Sail CHUN ; Won-Ki MIN
Annals of Laboratory Medicine 2025;45(5):493-502
Background:
An international reference measurement laboratory network for creatinine (Cr) is lacking; therefore, Korea developed an independent evaluation and certification system. The in vitro diagnostics (IVD) certification program, launched in 2017, formed part of a broader Cr standardization initiative intended to enhance accuracy at the manufacturing stage.
Methods:
The program was designed to evaluate analytical systems, including all reagent lots, calibrators, and instrument models, twice annually. Bias, imprecision, total error (TE), and linearity were evaluated based on established acceptance criteria. A post-certification process allows submission for a second challenge and validation of corrective actions.
Results:
Between 2017 and 2023, 489 analytical systems were evaluated. Average acceptance rates for bias, imprecision, TE, and linearity were 70.8%, 95.9%, 87.7%, and 87.8%, respectively. The lowest acceptance rate for bias evaluation was 8.7% for the kinetic Jaffe method without compensation in 2018. Over the 7-year period, the mean absolute percentage bias (absBias%), coefficient of variation (CV), and TE were 4.62%, 1.37%,and 7.29%, respectively. The highest absBias% (7.94%) was observed in the 0.0 ≤ Cr < 1.0target value range. Since 2019, a consistent reduction in absBias% has been observed.
Conclusions
This program is a pioneering response to the absence of a global certification program for Cr assays. It offers significant advantages, including comprehensive evaluations, fee-free participation, and a robust post-certification process. Continuous participation and improvement efforts by manufacturers have contributed to enhanced accuracy in Cr assays.
6.Increased bleeding tendency in liver transplantation for alcoholic liver disease
Mun Chae CHOI ; Eun-Ki MIN ; Deok-Gie KIM ; Jae Geun LEE ; Dae Hoon HAN ; Gi Hong CHOI ; Jin Sub CHOI ; Myoung Soo KIM ; Sinyoung KIM ; Dong Jin JOO
Annals of Liver Transplantation 2025;5(2):134-141
Background:
Alcoholic liver disease (ALD) includes a wide clinical spectrum from acute alcoholic hepatitis to severe cirrhosis and/or hepatocellular carcinoma. Until now, there has been no report revealing the bleeding tendency of ALD compared to other diseases in liver transplantation (LT). Thus, we analyzed blood loss and transfusion amounts during operation according to the etiologies of liver disease and model for end-stage liver disease (MELD) score.
Methods:
Out of 874 recipients who underwent LT, a total of 146 patients were excluded by our exclusion criteria. We compared 728 recipients’ baseline characteristics, operation time, blood loss, and transfusion amounts between ALD and nonALD according to MELD score.
Results:
The number of patients in the ALD group was 130 (17.9%), and 598 (82.1%) in the non-ALD group. The ALD group showed younger age, higher MELD score, and a higher proportion of deceased donor LT than the non-ALD group. Intraoperative blood loss and transfusions of red blood cells (RBCs), fresh frozen plasma, and platelets were significantly higher in the ALD group. When stratified by MELD score (cut-off: 20), ALD patients in both high and low MELD subgroups demonstrated greater blood loss and RBC transfusion requirements, even when international normalized ratio and platelet counts were similar. In multivariate logistic regression analysis, ALD was a significant risk factor for massive transfusion (odds ratio 1.813, 95% confidence interval 1.158–2.840, p=0.009).
Conclusion
The ALD group showed increased bleeding tendency than the non-ALD group during LT, irrespective of MELD score. This suggests that transplant surgeons should anticipate greater blood loss and ensure adequate transfusion resources during LT for ALD patients.
7.Adequate Tension and Clinical Results of Palmaris Longus Tendon Interpositional Graft in Closed Flexor Pollicis Longus Rupture
Joonha LEE ; Ki Hyeok KU ; Jae Hoon LEE ; Jong Hun BAEK
Clinics in Orthopedic Surgery 2025;17(3):506-513
Background:
Volar plate fixation for distal radial fractures is the most common cause of closed rupture of the flexor pollicis longus tendon (FPL). For treating a closed FPL rupture, transferring the fourth flexor digitorum superficialis or a tendon graft from the palmaris longus (PL) can be performed. This study reports the results of tendon grafting using the PL in closed FPL rupture and discusses the provision of optimal tendon tension.
Methods:
This retrospective study included 11 out of 20 patients who underwent PL tendon graft for closed FPL rupture between 2013 and 2022, with a follow-up period of more than 12 months. There were 4 men and 7 women, with an average age of 62 years. The average period from the date of rupture to surgery was 39 days. Ruptures occurred due to volar plate fixation in 7 cases, without a specific cause in 2 cases, and after a steroid injection for trigger thumb in 2 cases. The rupture site was in zone 2 in 4 cases and zone 5 in 7 cases. The mean follow-up period was 59 months. Optimal tension for the grafted tendon was determined by comparing the intraoperative angles of the interphalangeal (IP) and metacarpophalangeal (MCP) joints with the angles of the same joints at the final follow-up.
Results:
At the final follow-up, the mean IP joint motion was 61.0°, which was 81.5% of the contralateral side. The average range of motion of the MCP joint was 43.6°, which was 80.0% of the contralateral side. The pinch power was 90.8% of the contralateral side. Cases with > 70° IP joint motion were those in which the IP joint angle was > 45° during surgery. Moreover, the greater the flexion of the IP and MCP joints intraoperatively, the better the range of motion of the IP joints.
Conclusions
Tendon grafting using the PL is recommended as an effective surgical method to achieve 81.5% of contralateral IP joint motion in cases of closed FPL tendon rupture. Over-tensioning of the tendon graft with IP Joint flexion more than 45° during surgery is recommended.
8.Study Protocol of Expanded Multicenter Prospective Cohort Study of Active Surveillance on Papillary Thyroid Microcarcinoma (MAeSTro-EXP)
Jae Hoon MOON ; Eun Kyung LEE ; Wonjae CHA ; Young Jun CHAI ; Sun Wook CHO ; June Young CHOI ; Sung Yong CHOI ; A Jung CHU ; Eun-Jae CHUNG ; Yul HWANGBO ; Woo-Jin JEONG ; Yuh-Seog JUNG ; Kyungsik KIM ; Min Joo KIM ; Su-jin KIM ; Woochul KIM ; Yoo Hyung KIM ; Chang Yoon LEE ; Ji Ye LEE ; Kyu Eun LEE ; Young Ki LEE ; Hunjong LIM ; Do Joon PARK ; Sue K. PARK ; Chang Hwan RYU ; Junsun RYU ; Jungirl SEOK ; Young Shin SONG ; Ka Hee YI ; Hyeong Won YU ; Eleanor WHITE ; Katerina MASTROCOSTAS ; Roderick J. CLIFTON-BLIGH ; Anthony GLOVER ; Matti L. GILD ; Ji-hoon KIM ; Young Joo PARK
Endocrinology and Metabolism 2025;40(2):236-246
Background:
Active surveillance (AS) has emerged as a viable management strategy for low-risk papillary thyroid microcarcinoma (PTMC), following pioneering trials at Kuma Hospital and the Cancer Institute Hospital in Japan. Numerous prospective cohort studies have since validated AS as a management option for low-risk PTMC, leading to its inclusion in thyroid cancer guidelines across various countries. From 2016 to 2020, the Multicenter Prospective Cohort Study of Active Surveillance on Papillary Thyroid Microcarcinoma (MAeSTro) enrolled 1,177 patients, providing comprehensive data on PTMC progression, sonographic predictors of progression, quality of life, surgical outcomes, and cost-effectiveness when comparing AS to immediate surgery. The second phase of MAeSTro (MAeSTro-EXP) expands AS to low-risk papillary thyroid carcinoma (PTC) tumors larger than 1 cm, driven by the hypothesis that overall risk assessment outweighs absolute tumor size in surgical decision-making.
Methods:
This protocol aims to address whether limiting AS to tumors smaller than 1 cm may result in unnecessary surgeries for low-risk PTCs detected during their rapid initial growth phase. By expanding the AS criteria to include tumors up to 1.5 cm, while simultaneously refining and standardizing the criteria for risk assessment and disease progression, we aim to minimize overtreatment and maintain rigorous monitoring to improve patient outcomes.
Conclusion
This study will contribute to optimizing AS guidelines and enhance our understanding of the natural course and appropriate management of low-risk PTCs. Additionally, MAeSTro-EXP involves a multinational collaboration between South Korea and Australia. This cross-country study aims to identify cultural and racial differences in the management of low-risk PTC, thereby enriching the global understanding of AS practices and their applicability across diverse populations.
9.Deep Learning Technology for Classification of Thyroid Nodules Using Multi-View Ultrasound Images: Potential Benefits and Challenges in Clinical Application
Jinyoung KIM ; Min-Hee KIM ; Dong-Jun LIM ; Hankyeol LEE ; Jae Jun LEE ; Hyuk-Sang KWON ; Mee Kyoung KIM ; Ki-Ho SONG ; Tae-Jung KIM ; So Lyung JUNG ; Yong Oh LEE ; Ki-Hyun BAEK
Endocrinology and Metabolism 2025;40(2):216-224
Background:
This study aimed to evaluate the applicability of deep learning technology to thyroid ultrasound images for classification of thyroid nodules.
Methods:
This retrospective analysis included ultrasound images of patients with thyroid nodules investigated by fine-needle aspiration at the thyroid clinic of a single center from April 2010 to September 2012. Thyroid nodules with cytopathologic results of Bethesda category V (suspicious for malignancy) or VI (malignant) were defined as thyroid cancer. Multiple deep learning algorithms based on convolutional neural networks (CNNs) —ResNet, DenseNet, and EfficientNet—were utilized, and Siamese neural networks facilitated multi-view analysis of paired transverse and longitudinal ultrasound images.
Results:
Among 1,048 analyzed thyroid nodules from 943 patients, 306 (29%) were identified as thyroid cancer. In a subgroup analysis of transverse and longitudinal images, longitudinal images showed superior prediction ability. Multi-view modeling, based on paired transverse and longitudinal images, significantly improved the model performance; with an accuracy of 0.82 (95% confidence intervals [CI], 0.80 to 0.86) with ResNet50, 0.83 (95% CI, 0.83 to 0.88) with DenseNet201, and 0.81 (95% CI, 0.79 to 0.84) with EfficientNetv2_ s. Training with high-resolution images obtained using the latest equipment tended to improve model performance in association with increased sensitivity.
Conclusion
CNN algorithms applied to ultrasound images demonstrated substantial accuracy in thyroid nodule classification, indicating their potential as valuable tools for diagnosing thyroid cancer. However, in real-world clinical settings, it is important to aware that model performance may vary depending on the quality of images acquired by different physicians and imaging devices.
10.Long-Term Efficacy and Safety of Denosumab: Insights beyond 10 Years of Use
Jeonghoon HA ; Youn-Ju LEE ; Jinyoung KIM ; Chaiho JEONG ; Yejee LIM ; Jeongmin LEE ; Ki-Hyun BAEK ;
Endocrinology and Metabolism 2025;40(1):47-56
Osteoporosis management in post-menopausal women focuses on fracture prevention, with denosumab as a key therapeutic option. Despite its proven efficacy in reducing fracture risk and increasing bone mineral density (BMD) over 10 years, its long-term impact remains uncertain. We evaluated the literature on its efficacy and safety beyond the initial decade. Clinical trials and real-world studies confirm denosumab’s sustained efficacy, especially in lumbar spine BMD, with hip BMD stabilizing. Concerns about adverse events (AEs) like hypocalcemia and osteonecrosis of the jaw necessitate vigilant monitoring. Risks of atypical femoral fractures and malignancies also require attention, despite unclear links to treatment duration. Clinical guidelines for denosumab beyond 10 years are limited, emphasizing the need for careful monitoring. In certain scenarios, such as advanced chronic kidney disease, prolonged denosumab may be required to balance AE risks with fracture prevention benefits. Denosumab shows potential for long-term efficacy in augmenting BMD; however, monitoring for AEs is crucial to guide clinical decision-making effectively.

Result Analysis
Print
Save