1.Eligibility and causes of disqualification among living liver donor candidates: A single-center analysis of 991 candidates
Eun-Ju NAM ; Jong-Hyun KIM ; Hae-In SHIN ; Young-In YOON ; Deok-Bog MOON ; Ki-Hun KIM ; Tae-Yong HA ; Gi-Won SONG ; Dong-Hwan JUNG ; Gil-Chun PARK ; Shin HWANG ; Sung-Gyu LEE
Annals of Liver Transplantation 2026;6(1):17-24
Background:
A systematic evaluation of potential living liver donors is essential to ensure donor safety and optimize recipient outcomes in living donor liver transplantation (LDLT). This study aimed to assess donor acceptance rates and reasons for disqualification among individuals evaluated for LDLT at a high-volume transplant center over a one-year period.
Methods:
We retrospectively reviewed 1,087 potential living liver donors who presented for LDLT evaluation in 2023. Of these, 991 candidates advanced beyond the initial screening (Stage 1) and underwent comprehensive clinical, imaging, and pathological assessments (Stages 2 and 3). Candidates who discontinued after Stage 1 were excluded due to the absence of documented reasons for non-progression.
Results:
Among the 991 candidates who proceeded beyond initial screening, 473 (47.7%) completed the full donor evaluation, of whom 466 were judged to be suitable donors. Among suitable donors, 384 (82.4%) proceeded to donor hepatectomy, whereas 82 did not, primarily due to recipient-related factors such as clinical deterioration or withdrawal of consent. Donor ineligibility was determined in 422 candidates (42.6%), most commonly due to inadequate remnant liver volume (52.8%), hepatic steatosis (20.6%), and insufficient graft size (10.2%). Among candidates undergoing Stage 2 evaluation, 162 (16.3%) failed to meet steatosis criteria; 126 were excluded solely for steatosis and advised weight reduction, and 39 subsequently became eligible and successfully donated.
Conclusion
In this high-volume LDLT center, donor disqualification was primarily driven by remnant liver volume and hepatic steatosis. Targeted interventions such as weight reduction enabled successful donation in a subset of initially ineligible candidates, underscoring the importance of individualized donor evaluation and pre-donation optimization.
2.Clinical Outcomes and Use of Implantable Cardioverter-Defibrillator in Ischemic Heart Failure Patients with Reduced Ejection Fraction:A Retrospective Observational Study
Kyung Hoon CHO ; Ki Hong LEE ; Yong-Kyu LEE ; Seok OH ; Yongwhan LIM ; Joon Ho AHN ; Seung Hun LEE ; Dae Young HYUN ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jang Hoon LEE ; Joo-Yong HAHN ; Yu-Ri KIM ; Nam Sik YOON ; Hyung Wook PARK ; Weon KIM ; Myung Ho JEONG ;
Chonnam Medical Journal 2026;62(2):55-63
Limited data exist regarding the real-world practices and clinical outcomes in patients with ischemic heart failure with reduced left ventricular ejection fractions (LVEFs).Using nationwide registry data from South Korea, we aimed to investigate long-term outcomes and clinical practices, especially implantable cardioverter defibrillators (ICDs) implantation, in patients with reduced LVEFs at least 40 days after acute myocardial infarction (AMI). Of 13,056 patients with AMI between 2011 and 2015, we analyzed 350 (median age, 66 years [interquartile range, 56-75]) who had LVEFs <40% on follow-up transthoracic echocardiogram 40 days after the index event. The primary outcome was cardiac-cause mortality at 3 years. Secondary outcomes comprised major cardiovascular events as well as outcomes defined by the use of ICDs, cardiac resynchronization therapy defibrillators (CRT-Ds), and electrophysiology studies. Among 350 patients, 39 (11.1%) died from cardiac causes during 3 years of follow-up. Eleven (3.1%) were hospitalized for ventricular tachycardia. The rate of ICD or CRT-D implantation up to 3 years was 5.7% (20/350). Cox time-to-event analysis revealed older age, LVEF <30%, diabetes mellitus, and previous MI or revascularization as positively associated with cardiac death, whereas the use of statins and body weight <67 kg were negatively associated. This nationwide Korean registry demonstrated that only 5.7% of patients who had reduced LVEFs after 40 days of AMI underwent ICD implantations over 3 years. Considering the high mortality, concerted efforts are needed to improve clinical outcomes for patients who may have been candidates for ICD implantation.
3.Risk Factors of Complications in Patients With Persistent or Long-Standing Persistent Atrial Fibrillation/Atrial Flutter Who Underwent Electrical Cardioversion:A Multicenter Cardioversion Registry
Ki-Hun KIM ; Junbeom PARK ; Donghwan KU ; Jino PARK ; Seunghwan KIM ; Dong-Kie KIM ; Doo-Il KIM ; Sun Gyu CHOI ; Pil-Sung YANG ; Ju Youn KIM ; Jaemin SHIM ; Jinhee AHN ; Sung Ho LEE ; Sung Il IM ; Hong Euy LIM
Journal of Korean Medical Science 2026;41(1):e19-
Background:
Identifying the risks related to the complications of electrical cardioversion (ECV) can alert the determinaton of rhythm control in patients with atrial fibrillation (AF).
Methods:
We retrospectively reviewed 1,058 patients who underwent ECV for persistent or long-standing persistent AF/atrial flutter (AFL) from multiple centers. Patients were classified into the no-complication (1,023 patients) and complication (35 patients) groups based on the following major complications: stroke and/or systemic embolism (SSE), myocardial infarction, major bleeding, implantation of cardiac implantable electronic devices, ventricular tachycardia/fibrillation, and death at 1 year follow-up after ECV.
Results:
Compared with the no-complication group, the complication group exhibited a higher proportion of female patients (37% vs. 22%), as well as a higher proportion of patients with older age (67 ± 11 vs. 61 ± 10 years), diabetes mellitus (DM) (49% vs. 24%), heart failure (HF) (49% vs. 30%), SSE (23% vs. 9%), high CHA 2 DS 2 -VASc (CV) score (3.6 ± 1.8 vs.2.2 ± 1.4), low left ventricular ejection fraction (LVEF) (50 ± 16% vs. 58 ± 21%), and high left atrial volume index (LAVI) (51 ± 26 vs. 40 ± 20 mL/m 2 ). Class I and III antiarrhythmics were less prescribed in the complication group than in the no-complication group (57% vs.76%). Univariate analysis for complications revealed age (≥ 65 years), female sex, DM, HF, SSE, LVEF (< 50%), LAVI (≥ 40 mL/m 2 ), CV score (≥ 3), bradycardia on Holter (< 60/min), and no antiarrhythmics as risk factors. Among these, multivariate analysis revealed clinical significance of female sex and SSE.
Conclusion
Female sex and a history of SSE were the most important risk factors of complications in patients with persistent or long-standing persistent AF/AFL who underwent ECV.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Erratum: Korean Gastric Cancer Association-Led Nationwide Survey on Surgically Treated Gastric Cancers in 2023
Dong Jin KIM ; Jeong Ho SONG ; Ji-Hyeon PARK ; Sojung KIM ; Sin Hye PARK ; Cheol Min SHIN ; Yoonjin KWAK ; Kyunghye BANG ; Chung-sik GONG ; Sung Eun OH ; Yoo Min KIM ; Young Suk PARK ; Jeesun KIM ; Ji Eun JUNG ; Mi Ran JUNG ; Bang Wool EOM ; Ki Bum PARK ; Jae Hun CHUNG ; Sang-Il LEE ; Young-Gil SON ; Dae Hoon KIM ; Sang Hyuk SEO ; Sejin LEE ; Won Jun SEO ; Dong Jin PARK ; Yoonhong KIM ; Jin-Jo KIM ; Ki Bum PARK ; In CHO ; Hye Seong AHN ; Sung Jin OH ; Ju-Hee LEE ; Hayemin LEE ; Seong Chan GONG ; Changin CHOI ; Ji-Ho PARK ; Eun Young KIM ; Chang Min LEE ; Jong Hyuk YUN ; Seung Jong OH ; Eunju LEE ; Seong-A JEONG ; Jung-Min BAE ; Jae-Seok MIN ; Hyun-dong CHAE ; Sung Gon KIM ; Daegeun PARK ; Dong Baek KANG ; Hogoon KIM ; Seung Soo LEE ; Sung Il CHOI ; Seong Ho HWANG ; Su-Mi KIM ; Moon Soo LEE ; Sang Hyun KIM ; Sang-Ho JEONG ; Yusung YANG ; Yonghae BAIK ; Sang Soo EOM ; Inho JEONG ; Yoon Ju JUNG ; Jong-Min PARK ; Jin Won LEE ; Jungjai PARK ; Ki Han KIM ; Kyung-Goo LEE ; Jeongyeon LEE ; Seongil OH ; Ji Hun PARK ; Jong Won KIM ;
Journal of Gastric Cancer 2025;25(2):400-402
6.Korean Gastric Cancer AssociationLed Nationwide Survey on Surgically Treated Gastric Cancers in 2023
Dong Jin KIM ; Jeong Ho SONG ; Ji-Hyeon PARK ; Sojung KIM ; Sin Hye PARK ; Cheol Min SHIN ; Yoonjin KWAK ; Kyunghye BANG ; Chung-sik GONG ; Sung Eun OH ; Yoo Min KIM ; Young Suk PARK ; Jeesun KIM ; Ji Eun JUNG ; Mi Ran JUNG ; Bang Wool EOM ; Ki Bum PARK ; Jae Hun CHUNG ; Sang-Il LEE ; Young-Gil SON ; Dae Hoon KIM ; Sang Hyuk SEO ; Sejin LEE ; Won Jun SEO ; Dong Jin PARK ; Yoonhong KIM ; Jin-Jo KIM ; Ki Bum PARK ; In CHO ; Hye Seong AHN ; Sung Jin OH ; Ju-Hee LEE ; Hayemin LEE ; Seong Chan GONG ; Changin CHOI ; Ji-Ho PARK ; Eun Young KIM ; Chang Min LEE ; Jong Hyuk YUN ; Seung Jong OH ; Eunju LEE ; Seong-A JEONG ; Jung-Min BAE ; Jae-Seok MIN ; Hyun-dong CHAE ; Sung Gon KIM ; Daegeun PARK ; Dong Baek KANG ; Hogoon KIM ; Seung Soo LEE ; Sung Il CHOI ; Seong Ho HWANG ; Su-Mi KIM ; Moon Soo LEE ; Sang Hyun KIM ; Sang-Ho JEONG ; Yusung YANG ; Yonghae BAIK ; Sang Soo EOM ; Inho JEONG ; Yoon Ju JUNG ; Jong-Min PARK ; Jin Won LEE ; Jungjai PARK ; Ki Han KIM ; Kyung-Goo LEE ; Jeongyeon LEE ; Seongil OH ; Ji Hun PARK ; Jong Won KIM ; The Information Committee of the Korean Gastric Cancer Association
Journal of Gastric Cancer 2025;25(1):115-132
Purpose:
Since 1995, the Korean Gastric Cancer Association (KGCA) has been periodically conducting nationwide surveys on patients with surgically treated gastric cancer. This study details the results of the survey conducted in 2023.
Materials and Methods:
The survey was conducted from March to December 2024 using a standardized case report form. Data were collected on 86 items, including patient demographics, tumor characteristics, surgical procedures, and surgical outcomes. The results of the 2023 survey were compared with those of previous surveys.
Results:
Data from 12,751 cases were collected from 66 institutions. The mean patient age was 64.6 years, and the proportion of patients aged ≥71 years increased from 9.1% in 1995 to 31.7% in 2023. The proportion of upper-third tumors slightly decreased to 16.8% compared to 20.9% in 2019. Early gastric cancer accounted for 63.1% of cases in 2023.Regarding operative procedures, a totally laparoscopic approach was most frequently applied (63.2%) in 2023, while robotic gastrectomy steadily increased to 9.5% from 2.1% in 2014.The most common anastomotic method was the Billroth II procedure (48.8%) after distal gastrectomy and double-tract reconstruction (51.9%) after proximal gastrectomy in 2023.However, the proportion of esophago-gastrostomy with anti-reflux procedures increased to 30.9%. The rates of post-operative mortality and overall complications were 1.0% and 15.3%, respectively.
Conclusions
The results of the 2023 nationwide survey demonstrate the current status of gastric cancer treatment in Korea. This information will provide a basis for future gastric cancer research.
7.Atypical features of hepatic veno‑occlusive disease/sinusoidal obstruction syndrome after inotuzumab ozogamicin in adult patients with acute lymphoblastic leukemia
Kyung‑Hun SUNG ; Daehun KWAG ; Gi June MIN ; Sung‑Soo PARK ; Silvia PARK ; Sung‑Eun LEE ; Byung‑Sik CHO ; Ki‑Seong EOM ; Yoo‑Jin KIM ; Hee‑Je KIM ; Chang‑Ki MIN ; Seok‑Goo CHO ; Seok LEE ; Jae‑Ho YOON
Blood Research 2025;60():28-
Purpose:
Inotuzumab ozogamicin (INO) has demonstrated a safe bridging role to allogeneic hematopoietic stem cell transplantation (HSCT) in patients with relapsed or refractory B-cell acute lymphoblastic leukemia (R/R B-ALL). How‑ ever, hepatic veno-occlusive disease/sinusoidal obstruction syndrome (VOD/SOS) is frequently observed. This study aimed to identify significant features of INO-associated VOD/SOS.
Methods:
We reviewed seven cases of hepatic VOD/SOS that developed either during INO salvage or after alloge‑ neic HSCT following INO-induced complete remission (CR). Diagnosis and severity grading of VOD/SOS were based on the revised criteria from the European Society for Blood and Marrow Transplantation. Defibrotide was used to treat severe to very severe cases.
Results:
Four patients developed VOD/SOS during INO salvage therapy (at 21 and 36 days post-INO1, 77 days postINO3, and 21 days post-INO5), while three were diagnosed at 2, 5, and 10 days post-HSCT following INO-induced CR.Doppler ultrasonography revealed preserved portal vein flow (range 10.2–26.0 cm/sec) and normal hepatic artery resistive index (RI, range 0.56–0.74) in all but one patient (RI 0.83). Despite this, all patients presented with massive ascites and progressively elevated total bilirubin levels. All cases were classified as severe to very severe; six were treated with defibrotide and one underwent liver transplantation. Most patients ultimately died owing to VOD/SOS progression.
Conclusion
Post-INO VOD/SOS manifested as two different clinical settings and was characterized by preserved portal vein flow, which complicated diagnosis. Despite timely defibrotide administration, clinical outcomes were poor.These findings emphasize the need for vigilance and potential consideration of prophylactic strategies for prevention of INO-associated VOD/SOS.
8.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
9.Atypical features of hepatic veno‑occlusive disease/sinusoidal obstruction syndrome after inotuzumab ozogamicin in adult patients with acute lymphoblastic leukemia
Kyung‑Hun SUNG ; Daehun KWAG ; Gi June MIN ; Sung‑Soo PARK ; Silvia PARK ; Sung‑Eun LEE ; Byung‑Sik CHO ; Ki‑Seong EOM ; Yoo‑Jin KIM ; Hee‑Je KIM ; Chang‑Ki MIN ; Seok‑Goo CHO ; Seok LEE ; Jae‑Ho YOON
Blood Research 2025;60():28-
Purpose:
Inotuzumab ozogamicin (INO) has demonstrated a safe bridging role to allogeneic hematopoietic stem cell transplantation (HSCT) in patients with relapsed or refractory B-cell acute lymphoblastic leukemia (R/R B-ALL). How‑ ever, hepatic veno-occlusive disease/sinusoidal obstruction syndrome (VOD/SOS) is frequently observed. This study aimed to identify significant features of INO-associated VOD/SOS.
Methods:
We reviewed seven cases of hepatic VOD/SOS that developed either during INO salvage or after alloge‑ neic HSCT following INO-induced complete remission (CR). Diagnosis and severity grading of VOD/SOS were based on the revised criteria from the European Society for Blood and Marrow Transplantation. Defibrotide was used to treat severe to very severe cases.
Results:
Four patients developed VOD/SOS during INO salvage therapy (at 21 and 36 days post-INO1, 77 days postINO3, and 21 days post-INO5), while three were diagnosed at 2, 5, and 10 days post-HSCT following INO-induced CR.Doppler ultrasonography revealed preserved portal vein flow (range 10.2–26.0 cm/sec) and normal hepatic artery resistive index (RI, range 0.56–0.74) in all but one patient (RI 0.83). Despite this, all patients presented with massive ascites and progressively elevated total bilirubin levels. All cases were classified as severe to very severe; six were treated with defibrotide and one underwent liver transplantation. Most patients ultimately died owing to VOD/SOS progression.
Conclusion
Post-INO VOD/SOS manifested as two different clinical settings and was characterized by preserved portal vein flow, which complicated diagnosis. Despite timely defibrotide administration, clinical outcomes were poor.These findings emphasize the need for vigilance and potential consideration of prophylactic strategies for prevention of INO-associated VOD/SOS.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail